Loading...
20160134 Permit Pkg 04142016City of Yelm Community Development Department Building Division Phone: (360) 458 -8407 Fax: (360) 458 -3144 Applicant: Name: RICK CHRISTENSEN Address: 11915 CLEAR LAKE RD EATONVILLE WA 98328 Property Information: Site Address: lr%r%nr% inr.TW Av= CC Assessor Parcel No.: 64303400502 Contractor Information: Name: RICK CHRISTENSEN Address: 11915 CLEAR LAKE RD EATONVILLE WA 98328 Contractor License No.: Project Information: Project: COMMERCIAL REMODEL Description of Work: 3503 RESTAURANT TI Sq. Ft. per floor: First 3503 Second Third Garage Basement Fees: Subdivision: Permit No.: 20160134 Issue Date: 4/14/2016 (Work must be completed within 180 days) Phone: Owner: RICK CHRISTFNRFN Phone: Expires: 0 /00 /0000 Heat Type (Electric, Gas, Other): HEAT PUMP Lot: Item Contractor Fees BUILDING RICK CHRISTENSEN $57,550.84 FIRE RICK CHRISTENSEN $ 160.46 MECHANICAL SUNSET AIR INC $ 75.00 PLUMBING AFFORDABLE PLUMBING $ 132.00 FIRE ALARM ALARM CENTER 5/4/2016 $ 183.56 FIRE SPRINK KNIGHT FIRE $ 878.87 TOTAL FEES: $ 58,980.73 Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of r rd. If applying as a contractor, I further certify that I am currently registered in the to of Was ing n. Signature Date 6s Firm OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: 41 i� fQelm44 (36 ) REC #: 00230233 5/04/2016 11:02 AM OPER: CO TERM: 001 REF #.. 5114 PAID BY: TRAM: 33.0000 BUILDING 83 IRMIS 20160134 CHRISTENSEN, RICK 16605 106TH AVE E5(;CR FA TENDERED: 183.56 (HECK APPLIED: 183.56 - CHANGE: "J�+' 0.00 T={2E A �_Al2.M CITY OF YELM COMMERCIAL BUILDING PERMIT APPLICATION FORM Project Address: 10602, 1000 AVE S1 Parcel #: AL}7� ()()S0l Zoning; Current Use: Proposed Use: New Construction C Re -Model / Re -Roof / Tenant Improvement Plumbing Mechanical _ Fire Prevent /Suppress /Alarm ❑ Other Project Description /Scope of Work: 1 NSA tit NEW F if2 t s^�►l�f% (r, Sv �i"En'1 Project Value: f f Building Area (sq. ft) Parking Garage 1St Floor202nd Floor P Floor Building Height Are there any environmentally sensitive areas located on the parcel? _ completed environmental checklist must accompany permit application. BUILDING OWNER/TENANT NAME: RZ LK r'.u2cST1At�1S JJ ADDRESS; ql s r,c c 12C. LPI'Kt R2 p S EMAIL CITY STATEI,,)F ZIP qg.? 2 � TELEPHONE ARCHITECT /ENGINEER LICENSE # ADDRESS EMAIL CITY STATE ZIP TELEPHONE If yes, a - 13ENE-R t- CONTRACTORCAP�T >. Al_At�M TELEPHONE ADDRESS_- 210J3 N�fi rZiSn,>J f-�V. T\\ L0. ''67SCFzMAIL CITY0 Li -1MPtfa STATE(:)( ZIP q2 S02 FAX I p - cE,E,- SO CONTRACTOR'S LICENSE #C'RF'STR�i2 FXP DATE(OI�PITY LICENSE #13 -On 5-S 0 PLUMBING CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # MECHANICAL CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # Copy of City Mitigation documentation (TFC). I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City of Yelm. Ap lica is Signature Date Ownbr9 Contractor/ Owner's Agent/ Contractor's Agent/ Tenant (Please circle one.) All permits are non - transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period o 1 Cft ft LL .----- - - - - -- 105 Yelm Ave W (360) 458 -3144 FAX Yelm, WA 98597 www.ci.yelm.wa.us 04/11/2016 Product Data Submittal Creek Street 10602 106Th Ave SE Yelm, WA. 98328 Project Number 16 -44 Fire Alarm System Equipment Contractor: Capitol Alarm, Inc. 2103 Harrison Ave NW #2512 Olympia, WA. 98502 Office 360- 866 -0400 Fax 360- 866 -3950 By- _----------- - - - - -- 0, t3 0 SECURITY FIRE CCTV NURSE ACCESS ALARM CALL CONTROL Global Project Values: SILENT Project Name: Creek Street Standby Hours: 24 KNIGHT 0 Project ID: 16-44 Alarm Mins:� Prepared By: SER Derating Factor. 1.2 5700 Calculations Date: 4/11/2016 Voltage Drop blaming Threshold %: 10 Version 12.30. 10 Panel ID: 15700 1 Model: 5700 Add. Fire Alarm Control Panel Max NAC Current: 2.5 Amps Location: I Fire Sprinkler Room Volts: 24 VDC Max Panel Current: 2.5 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Ckt.# Circuit Name Qty Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 5700 5700 CTRL Panel 1 0.200 0.325 SK Photo, Photo -T 1 0.000 0.000 SK Ion 0.000 0.000 SK Heat, Heat -HT 0.000 0.000 SK Heat ROR 0.000 0.000 SK Beam, Beam -T 0.000 0.000 SK Duct 0.000 0.000 SK Acclimate 0.000 0.000 SK Control 0.000 0.000 SK Control -6 0.000 0.000 SK Relaymon 0.000 0.000 SK lMonitor, Minimon 1 0.000 0.000 SK Monitor -2 2 1 0.002 0.002 SK Monitor -10 0.000 0.000 SK Pull -SA, Pull -DA 1 0.000 0.000 SK Relay 0.000 0.000 SK Relay -6 0.000 0.000 SK Zone 0.000 0.000 SK Zone -6 0.000 0.000 SK Isolator Module 0.000 0.000 SSB224BI Isolator Base 0.000 0.000 B200SR Sounder Base 0.000 0.000 SSB224RB Relay Base 0.000 0.000 SSRTS151 Magnetic Remote Test 0.000 0.000 SSRTS151KEY Key Activated Test 0.000 0.000 SSRA100Z Remote LED 0.000 0.000 1 5860 LCD Remote Annunc. 0.000 0.000 5824 LCD Remote Annunc. 0.000 0.000 5496 Power Expander 0.000 0.000 5895XL Power Expander 0.000 0.000 5865 -3 LED Annunciator (313) 0.000 0.000 5865 -4 LED Annunciator (413) 0.000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 NAC #1 NAC Circuit 1.1 0.000 0.861 1#14 Solid 2.52 210 1.06 19.49 4.47% NAC #2 NAC Circuit 1.2 0.000 0.353 1#14 Solid 1 2.52 1 140 0.71 20.15 1.22% Total Standby Current (Amps) 0.203 1.542 Total Alarm Current (Amps) Alarm Time In Minutes/ 60 (5 Mins) Total Alarm AH Required Command Shortcuts j Configure Circuits Print Page i g J I Standby Time In Hours 24 0.083 Total Standby AH Required 4.860 0.128 Total Combined AH Required 4.99 Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 5.99 Project intormation Project Name: Creek Street Prepared By: SER Project ID: 16-44 Date: 4/11/2016 Ckt. Number: Ckt. Name: NAC #1 NAC Circuit 1.1 Panel ID: 5700 User Aux Power Circuit 5700 _ Aux Power Circuit Qty Device Current Draw Each Standby Alarm Current Draw Total Standby Alarm 3 System Sensor S /SC Strobe (15cd) 0.000 0.066 0.000 0.198 3 System Sensor P2 /PC2 Horn /Strobe (110cd) 0.000 0.221 0.000 0.663 0.132 Unused 0.000 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Totalsl 0.000 1 0.861 Ckt. Number: Ckt. Name: NAC #2 NAC Circuit 1.2 Panel ID: Use: 5700 _ Aux Power Circuit Qty Device Current Draw Each Standby Alarm Current Draw Total Standby Alarm 1 System Sensor P2 /PC2 Horn /Strobe (110cd) 0.000 0.221 0.000 0.221 2 System Sensor S /SC Strobe (15cd) 0.000 0.066 0.000 0.132 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totalsi 0.000 0.353 SILENT KNIGHT by Honeywell IntelliKnight® Model 5700 Single Loop Addressable Fire Alarm Control System The affordable addressable fire alarm control panel solution. IntelliKnight Model 5700 is a class leading single loop addressable fire alarm control /communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built -in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 800 - 328 -0103. Description The basic IntelliKnight 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial /parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5700 supports SD or SK devices. 5700 also features a powerful built -in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built -in support for up to 50 SK detectors and 50 SK modules creating a total point capacity of 100 points • Built in support for up to 50 SD devices • Up to 125 zones and 125 output groups • Uses standard wire —no shielded or twisted pair required • Built -in digital communicator • Central station reporting by point or by zone • Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC • Drift compensation • 13 pre - programmed output cadences (including ANSI - 3.41) and 4 programmable outputs • Notification circuits configurable as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power • Built -in synchronization for AMSECO, Gentex ®, Faraday, System Sensor® and Wheelock® appliances • Built -in annunciator with 80- character LCD display • RS -485 bus provides communication to system accessories • Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5660 Silent Knight Software Suite (SKSS) • Two built -in Form C programmable relays rated at 2.5A at 27.4 VDC Model 5700 • Improvements in SKSS deliver five times faster upload /downloads • Built -in RS -232 interface for programming via PC • Built -in Form C trouble relay rated at 2.5A at 27.4 VDC • Programmable date setting for Daylight Saving Time Compatibility The 5700 signal line circuit (SLC) supports multiple device types of the same protocol: • SK • SD You cannot mix SD and SK SLC devices on a FACP. P/N 350392 Rev M © 2014 Honeywell International Inc. Model 5700 Fire Alarm Control Panel Specifications Electrical Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A @ 27.4 VDC Notification Power: 2.5A @ 27.4 VDC, power - limited Standby Current: 200 mA Alarm Current: 365 mA Notification /Aux Power Circuits: 2.5A @ 27.4 VDC per circuit, power - limited Battery Charging Capacity: 7.0 -35.0 AH Battery Size: 7 AH max. allowed in FACP cabinet. Larger capacity batteries can be housed in an RBB accessory cabinet. Physical Dimensions: 12.75" W x 15.2" H x 3.4" D (32.39 W x 38.42 H x 8.57 D cm) Weight: 11.5 lbs. (5.2 kg) Color: Red Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) Listings NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non - coded) signalling services. Other Approvals: UL Listed; CSFM 7170 -0559: 144; MEA 429 -92 -E Vol. XVI; OSHPD (CA) OSP- 0065 -10 S -BUS Accessories 5860/R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5700. The system can be fully programmed and operated from any 5860. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power - limited notification appliance circuit outputs. 5880 LED /10 Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5865 -3 and 5865 -4 Remote LED Annunciator Features 30 Programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865 -4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial /Parallel Printer Interface Module Provides one parallel and one RS -232 serial port for connecting a printer to 5808. Use to print a real -time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite User - friendly Windows software for remote programming of 5700s using a PC. Upload and view panel account information, event history, and detector status. 5496 5670 Silent Knight Software Suite End -user facility management software allows viewing of detector status and event history via modem or direct connection. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D SK -SCK Seismic Compliance Kit. SD505 -DTS -K Remote test switch that provides remote key operated test function and annunciation of detector alarm with SD505- DUCTR. SP -TR Small panel trim ring. Use to flush mount the panel. 16.975' H x 14.630" W. SD and SK Devices See the data sheets listed below for a complete listing of the SD and SK devices. 53624 SD Devices data sheet 53623 SK Devices data sheet SILENT This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 by Honeywell Clintonville Road, Northford, CT 06472 -1610 Phone: (800) 328 -0103, Fax: (203) 484 -7118. For Technical Support, Please call 800 - 446 -6444. www.silentknight.com Assembled In America SK -Photo and SK- Photo -T Intelligent Photoelectric Smoke Sensors The SK -Photo is a photoelectric smoke detector and the SK- Photo -T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800 - 328 -0103 or in Connecticut, call (203) 484 -7161. Description SK -Photo and SK- Photo -T are plug -in type smoke sensors that combine a photoelectric sensing chamber with addressable analog communications. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK -Photo and SK- Photo -T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the SK- Photo -T, dual electronic thermistors add 135 °F (57 °C) thermal technology to maximize detection. Features • Sleek, low - profile design • Base included • Reliable analog communications for trouble -free operation • Age resistant polymer housing • Dual electronic thermistor design on the SK- Photo -T • Superior EMI resistance for reliability • Simple field cleaning for code compliance • Variety of mounting options to meet any application • Dual LED indicators for 360° visibility • Detector transmits signal to indicate maintenance is required • Optional remote LED annunciator (System Sensor@ PN RA100Z) • Plug -in mounting provides ease of installation • Tamper -proof feature available on mounting bases • Listed for use in duct applications • Rotary address switches for fast installation • UL Listed • FM Approved Specifications Physical Height: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) Shipping Weight: 5.2 oz. (147 g) Electrical Operating Voltage: 15 -32 VDC Standby Current: 300 pA @ 24 VDC Maximum Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Environmental Operating Temperature SK- Photo: 321 — 120 °F (0 °C — 49 °C) SK- Photo -T: 320 — 100 °F (0 °C — 38 °C) Humidity: 10% — 93% non - condensing Other Ratings SK- Photo -T Thermal: Fixed temperature set point 135 °F (57 °C) Velocity: 0 — 4000 fpm (0 — 20 m /sec) SK -Photo Insect Screen Hole Size: 0.016" (0.41 mm) nominal SK -Photo (Base included) Compatibility The SK -Photo and SK- Photo -T are compatible with the following IntelliKnight FACPs: 5700 5808 5820XL SK -Photo and SK- Photo -T are compatible with the following detector bases: B210LP (included) 6" base B501 2 wire base 8501 BHT -2 Temporal base B224RB Relay base B224BI Isolator base B501BH -2 Sounder base SILENT KNIGIff by IHwwpve4 Model SK -Photo and SK- Photo -T Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK -Photo or SK- Photo -T with thermal. The combination detector head, and twist -lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK -Photo or SK- Photo -T. Base shall be the appropriate twist -lock base part number B21OLP (included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK -Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. COMPAMW FRCP [:;i VftV sK -swWo 11wAmr Niw"INng some SILEDU This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject FORM# 350118 Rev A, to change without notice. For more information, contact Silent Knight 12 © 2009 Honeywell International Inc. by Hunk Clintonville Road, Northford, CT 06472 -1610 Phone: (800) 328 -0103, Fax: (203) 484 -7118. www.silentknight.com B501 and ' B21OLP Intelligent Detector Bases .> B501 and B21OLP plug in detector mounting bases, are just two of the variety of ways to intall detectors in any application. For more information about the IntelliKnight system, or to locate you nearest source, please call 1- 800 - 328 -0103 or in Connecticut, call (203) 484 -7161. Description The B21OLP 6" Mounting Base and the B501 4" Mounting Base are plug in detector bases for SK style detectors intended for use with Silent Knight IntelliKnight series fire ! alarm control panels (FACPs). The B21OLP and B501 have w screw terminals for power ( +) and ( -) and remote annunciator connections. Communication takes place over the power ( +) and ( -) lines. Features • Plug -in mounting provides ease of installation • Tamper -proof feature prevents removal of the detector without the use of a tool • Range of mounting options to meet any application • B501 allows for aesthetically pleasing installation with Recessed Mounting Kit (PN RMK400) • Rotary address switches for fast installation • Optional remote LED annunciator (PN RA100Z) • SEMS screws, 12 -22 AWG • UL Listed Installation The B21OLP and B501 can be mounted on a variety of junction boxes as shown in the tables below. U.S. Junction box Selection Guide" Metric Junction box Selection Guide* B210LP Base ( B501 Base Compatibility The B21OLP and B501 are compatible with the following SK- series detectors: • SK -Photo Photoelectric Smoke Detector and SK -- Photo -T Photoelectric Smoke Detector with Thermal • SK- Acclimate Multicriteria Photoelectric Smoke Detector • SK -Ion Ionization Smoke Detector • SK -Heat Fixed Temperature Thermal Detector, SK - Heat -ROR Rate -of -Rise Detector with Thermal, and SK- Heat -HT Fixed High Temperature Thermal Detector The B210LP and B501 are compatible with the following IntelliKnight FACP's: 5700 5808 5820XL SILENT KNIGHT by Honeywell Model B501 and B21OLP Specifications Physical B21OLP Diameter: 6.1" (155 mm) B501 Diameter: 4.1" (104 mm) Electrical Wire Gauge: 18 -12 Terminals: Terminal 1: Power ( —) and Optional RA10OZ Terminal 2: Power ( +) Terminal 3: Optional RA10OZ Remote Annunciator Environmental Operating Temperature: 32 °F — 150 °F (0 °C — 66 °C) Humidity: 10% — 93% non - condensing B501 and B21OLP Mounting Bases Ordering Information B21OLP 6" Mounting Base B501 4" Mounting Base Accessories RA10OZ Remote LED Annunciator. RMK400 Recessed Mounting Kit. Provides low profile for use with 8501. XR2B Detector Removal Tool. A removal and replacement tool for SK plug -in detectors. Includes the T55- 127 -000. M02 -04 -01 Detector Test Magnet. M02 -09 -00 Test Magnet with Telescoping Handle. XP -4 Extension Pole for XR213. Extends from 5 -15 ft. T55- 127 -000 Detector Removal Head. BCK -200B Black Detector Kit. For SK series detectors. This document is not intended to be used for installation purposes. We try to MADE IN AMERICA SILENT keep our product information up -to -date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject FORM# 350995 Rev A to change without notice. For more information, contact Silent Knight ECN 09 -520 12 Clintonville Road, Northford, CT 06472 -1610 Phone: (800) 328 -0103, © 2009 Honeywell International Inc. by i' onay"I Fax: (203) 484 -7118. www.silentknight.com 3 SILENT SK- Pull -SA and SK- Pull -DA KNIGHT Intelligent Pull Stations by Honeywell The SK- Pull -SA and SK- Pull -DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK- Pull -DA and SK- Pull -SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1- 800 - 328 -0103. Description The SK- Pull -SA is a single action pull station requiring only one motion to activate the station. The SK- Pull -DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual -color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Meets ADA requirement for 5 Ibs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble -free operation • Braille text on station handle • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • Rotary address switches for fast installation • UL Listed, including UL 38, Standard of Manually Actuated Signaling System SK- Pull -SA SK- Pull -DA Compatibility The SK- Pull -SA and SK- Pull -DA are compatible with the following IntelliKnight FACP's: 5600 5700 5808 5820XL 5820XL -EVS Model SK- Pull -DA and SK- Pull -SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knight model SK- Pull -SA single action pull station or SK- Pull -DA, dual action pull station. SK- Pull -DA or SK- Pull -SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. IN SLC OUT Compatible FRCP Class A Wiring: Class B Wlring: Specifications Physical Height: 5.5" (14 cm) 6 r i i I :sus Wiring SK- Pull -SA & SK- Pull -DA Pull Stations Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi- Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N /O) switch which closes upon activation of the pull station 6 Electrical Operating Voltage: 15 -32 VDC Average Operating Current (LED flashing): 300 pA Wire Gauge: Up to 12 AWG (3.1 mmz) Environmental Operating Temperature 32e — 1201F (0 °C — 49 °C) Humidity: 10% — 93% non - condensing Accessories BG -TR Optional trim ring. SB -1 /0 Surface backbox SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA to keep our product information up -to -date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are FORM# 350135 Rev C subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472 -1610 ©2013 Honeywell International Inc. by Honeywell Phone: (800) 328 -0103, Fax: (203) 484 -7118. For Technical Support, Please call 800 446 -6444. www.silentknight.com SILENT SK- Monitor KNIGHT by Honeywell Intelligent Monitor Module The SK- Monitor module provides an interface to contact devices, such as security contacts, waterflow switches, or pull stations. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK- Monitor is an addressable monitor module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK- Monitor is intended for use in intelligent, two -wire systems, where individual address of each module is selected using the built -in rotary switches. The SK- Monitor supports Class A supervised or Class B supervised wiring to the load device. Conventional 4 -wire smoke detectors can be monitored for alarm and trouble conditions. Features • Single contact monitor • Support for Class A and Class B wiring • Fully supervised • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Attractive ivory cover plate • Rotary address switches for fast installation • SEMS screws for easy wiring • UL Listed Installation The SK- Monitor mounts directly into a 4" square electrical box. The box must have a minimum depth of 2 -1/8 ". A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight. SK- Monitor Compatibility The SK- Monitor is compatible with the following IntelliKnight FACP's: 5700 5808 5820XL Model SK- Monitor Intelligent Monitor Module To Next Device + 100 Class B a Initiating Device Circuit NFPA Style B © O Power Limited 230A Max @ 12 VDC Max To Next Device + O Class A EOL Resistor Is Internal � O at Terminals B 6 9 I (v Wiring IDP- Monitor Modules Specifications 5.5 mA (with LED latched on) Physical LED Current: 5.5 mA (with LED latched on)End -of -Line Height: 4.5" (11.4 cm) Resistance: 47K Width: 4" (10.2 cm) Initiating Device Circuit Wiring Resistance: 1,500 max Depth: 1.25" (3 cm) SLC Loop Resistance: 40 max. Shipping Weight: 6.3 oz (196 g) Environmental Electrical Operating Voltage: 15 - 32 VDC Current Draw (LED on): 5.0 mA max Operating Current (LED flashing): 375 pA Standby Current: Operating Temperature: 320F - 120 °F (0 °C - 49 °C) Humidity: 10% - 93% non - condensing Ordering Information SK- Monitor Monitoring Module 400 pA max @ 24 VDC (one communication every 5 sec with Accessories 47K EOL) SMB500 4" Square Surface Mount Electrical 550 pA max @ 24 VDC (one communication every 5 sec with Box EOL <1K) This document is not intended to be used for installation purposes. We try MADE IN AMERICA SILENT to keep our product information up -to -date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent FORM# 350131 Rev B Knight 12 Clintonville Road, Northford, CT 06472 -1610 © 2010 Honeywell International Inc. by Honeywell Phone: (800) 328 -0103, Fax: (203)484 -7118. www.silentknight.com r � o a i - From Compatible Silent Knight 3 + FACP or Previous Device �. ..,,o. Communication Loss (Optional Conenction Q for Panels Which Support this Feature) Class A Wlrin g: . Class B Wlring: Any Number of UL Listed Contact Closure Devices May Be Used. Do Not Mix Fire Alarm Or� 1Vl Initiating Devices, Supervisory, or Security Devices on the Same Module. t — From Compatible Silent Knight + FACP or Previous Device Communication Loss (Optional Conenction for Panels Which Support this Feature) OoT Wiring IDP- Monitor Modules Specifications 5.5 mA (with LED latched on) Physical LED Current: 5.5 mA (with LED latched on)End -of -Line Height: 4.5" (11.4 cm) Resistance: 47K Width: 4" (10.2 cm) Initiating Device Circuit Wiring Resistance: 1,500 max Depth: 1.25" (3 cm) SLC Loop Resistance: 40 max. Shipping Weight: 6.3 oz (196 g) Environmental Electrical Operating Voltage: 15 - 32 VDC Current Draw (LED on): 5.0 mA max Operating Current (LED flashing): 375 pA Standby Current: Operating Temperature: 320F - 120 °F (0 °C - 49 °C) Humidity: 10% - 93% non - condensing Ordering Information SK- Monitor Monitoring Module 400 pA max @ 24 VDC (one communication every 5 sec with Accessories 47K EOL) SMB500 4" Square Surface Mount Electrical 550 pA max @ 24 VDC (one communication every 5 sec with Box EOL <1K) This document is not intended to be used for installation purposes. We try MADE IN AMERICA SILENT to keep our product information up -to -date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent FORM# 350131 Rev B Knight 12 Clintonville Road, Northford, CT 06472 -1610 © 2010 Honeywell International Inc. by Honeywell Phone: (800) 328 -0103, Fax: (203)484 -7118. www.silentknight.com 3 SILENT KNIGHT by Honeywell SK- Monitor -2 Intelligent Dual Monitor Module The SK- Monitor -2 module is capable of monitoring two separate Class B circuits simultaneously, making it ideal for waterflow tamper switch and flow switch monitoring. For more information about the IntelliKnight system, or to locate you nearest source, please call 1- 800 - 328 -0103. Description The SK- Monitor -2 is an addressable monitor module with two initiating circuits for use with o Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK- Monitor -2 acts ij as an interface to contact devices, such as waterflow switches and pull stations. The SK- Monitor -2 supports Class B supervised wiring to the load device. Conventional 4 -wire smoke detectors can be monitored for alarm and trouble conditions. Features • Monitor two circuits, with unique addresses, simultaneously • Support for Class B wiring • Fully supervised • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Attractive ivory cover plate • Rotary address switches for fast installation • SEMS screws for easy wiring • UL Listed SK- Monitor -2 Installation SK- Monitor -2 mounts directly into a 4" square electrical box. The box must have a minimum depth of 2 -1/8 ". A surface mount electrical box (System Sensor® part number SMB500) is available from Silent Knight. Compatibility The SK- Monitor -2 is compatible with the following IntelliKnight FACP's: 5700 5808 5820XL Model SK- Monitor -2 Intelligent Dual Monitor Module Two Initiating Device Circuits NFPA Style 8 Power Limited 230 NA Max @ 12 VDC Max Wiring SK- Monitor -2 Modules Specifications End -of -Line Resistance: 47K 0 Physical Max IDC wiring resistance: 1,50052 Height: 4.5" H x 4" W x 1.25" D SLC Line Loop Resistance: 4052 max. Shipping Weight: 6.3 oz (196 g) Environmental Electrical Operating Temperature: 32 °F — 120 °F (0 °C — 49 °C) Operating Voltage: 15 — 32 VDC Humidity: 10% — 93% non - condensing Current Draw (LED on): 6.4 mA max Accessories Operating Current (LED flashing): 750 pA SMB500 4" Square Surface Mount Electrical Box This document is not intended to be used for installation purposes. We try MADE IN AMERICA SILENT to keep our product information up -to -date and accurate. We cannot cover KNIGH' all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent FORM# 350124 Rev B Knight 12 Clintonville Road, Northford, CT 06472 -1610 @ 2009 Honeywell International Inc. by Honeywell Phone: (800) 328 -0103, Fax: (203)484 -7118. www.silentknight.com SK -Relay r Intelligent Relay Module The SK -Relay Module is intended for use in intelligent, two -wire systems where the individual address of each module is selected using the built in rotary switches. For more information about the Intelliknight system, or to locate you nearest source, please call 800 - 328 -0103 or in Connecticut, call (203) 484 -7161. The SK -Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The SK -Relay contacts can be used for virtually any normally open or normally closed application. Each SK -Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the SK- Relay, the relay is triggered by the FACP. Features • Two sets of Form C contacts • Rotary address switches for fast installation • Contacts are rated for a variety of amps (see Specifications) • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Relay programming is completely flexible —can be mapped to zone conditions • Polling LED visible through the cover plate • Attractive ivory cover plate • SEMS screws for easy wiring • UL Listed SK -Relay Installation The SK -Relay mounts directly into a 4" square electrical box. The box must have a minimum depth of 2 -1/8 ". A surface mount electrical box (System Sensor"D PN SMB500) is available from Silent Knight Compatibility The SK -Relay is compatible with the following IntelliKnight FACP's: 5700 5808 5820XL SILENT KNIGHT by Honeywell Model SK -Relay To Next Device — If Any Wiring to Terminals 3 — 9 is Not Power + I Limited, the CB500 Barrier is Required, The CB600 Includes a Non -Power Limited Label, Which Must Be Placed Over the Power Limited a (Z) Terminal Information on the Name Plate Label. Relay Common 2' s ate# Normally Closed 2 s �� Normally Open 2 7 �,.• 2' Relay Common 1 a s ''�` — From Compatible FACP . .. �: Normally Closed 1 s ;; 4 * or Previous Device Module Does Not Supervise Normslly Open 1 Controlled Circuits Wiring the SK -Relay Module Specifications End -of -Line Resistance: not used Physical Standby Current: 300 pA max @ 24 VDC (one Height: 4.65" communication every 5 sec with LED enabled) Width: 4.25' Depth: 1.1" Shipping Weight: 6.3 oz (196 g) Electrical Operating Voltage: 15 — 32 VDC Current Draw: 6.5 mA max (LED on) Operating Current: 230 pA (LED flashing) direct poll 255 pA (LED flashing) group poll LED Current: 5.5 mA (with LED latched on) SLC Loop Resistance: 4052 max. Relay Contact Ratings 3.OA @ 30 VDC resistive 0.9A @ 110 VDC resistive 0.9A @ 125 VAC resistive 0.5A @ 125 VAC inductive (PF = .35) 0.7A @ 75 VAC inductive (PF = .35) SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT specific our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight FORM# 350127 Rev A by Honeywell 12 Clintonville Road, Northford, CT 06472 -1610 Phone: (800) 328 -0103, ©2009 Honeywell International Inc. Fax: (203) 484 -7118. www.silentknight.com 4�� SYSTEM SENSORO Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications SpectrAlert" Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features • Plug -in design with minimal intrusion into the back box •Tamper- resistant construction Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela • Field- selectable candela settings on ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and three volume selections Universal mounting plate for ceiling units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert devices • Compatible with MDL sync module Agency Listings SIGNALING UL F M LISTED APPROVED W; 12 horn strobes, horns) 3023572 55512 (strobes) chime strobes) SPECTRAWrt f r o m S s t e m S e The SpectrAlert Advance series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE - printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug -in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time - consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections. MEA approved 7715 d strobes) 16653186 25 - 8 (hom strobes, MEA452 -05 -E chime strobes) 7135 - 1653:189 (horns, chimes) SPECTRAWrt f r o m S s t e m S e The SpectrAlert Advance series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE - printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug -in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time - consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections. SpectrAlert Advance Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4 -inch octagon back box, or double -gang back box.Two- wire products shall also mount to a single -gang 2 x 4 x 17/8 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync - Circuit' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync - Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24- volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field - selectable candela settings including 15,15/75, 30, 75, 95,110,115,135, 150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non - temporal (continuous) pattern.These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync- Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 41'/16 x 21/s -inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32 °F to 120 °F (0 °C to 49 °C) Humidity Range 10 to 93% non- condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range' 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8 °diameter x 2.5 "high (173 mm diameter x 64 mm high) Ceiling -Mount Back Box Skirt Dimensions (BBSC -2, BBSCW -2) 7.1 "diameter x 2.2 -high (180 mm diameter x 57 mm high) Ceiling -Mount Trim Ring Dimensions (sold as a 5 pack) (TRC- HS,TRCW -HS) 6.9- diameter x 0.35- high (175 mm diameter x 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. Awsoosao UL Current Draw Data UIL Max. Strobe Current Draw (mA RMS) 8 -17.5 Volts 16 -33 Volts Candela DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 High Candela Range 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 135 150 177 NA NA NA NA NA NA 228 246 281 207 220 251 Horn Strobe Tones and Sound Output Data 8-17.5 16-33 24 -Volt Nominal Switch Position 185 dB Volts DC FWR Volts DC NA Reverberant DC NA Anechoic DC FWR 286 Temporal High 258 UL Max. Current Draw (rnA DC Input RMS), 2-Wire Horn 8 -17.5 Volts 15 Strobe, 15/75 16-33 Volts 15 15/75 30 75 2 95 Medium 110 74 115 Temporal High 137 86 147 96 79 Temporal 90 107 176 76 194 83 212 94 218 Temporal Medium 132 High 144 82 69 88 80 97 157 100 182 Non Temporal 201 78 210 Temporal Low 132 90 143 98 66 6 77 93 154 75 179 81 198 84 207 Non Temporal High 141 Coded 152 82 91 88 100 116 176 101 201 8t 221 Medium 229 Non Temporal Medium 133 85 145 90 75 98 85 102 163 75 187 81 207 88 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non Temporal Medium 134 155 85 95 110 166 189 208 216 Non Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA DC Input RMS), 2-Wire 16-33 Volts 135 Horn 150 Strobe, 177 185 FWRlnput 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Horn Strobe Tones and Sound Output Data 8-17.5 16-33 24 -Volt Nominal Switch Position Sound Pattern dB Volts DC FWR Volts DC FWR Reverberant DC FWR Anechoic DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non Temporal High 82 82 88 88 93 92 100 100 5 Non Temporal Medium 78 78 85 85 90 90 98 98 6 Non Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 'Settings 7, 8, and 9 are not available on 2 -wire horn strobes. AVDS00500 SpectrAlert Advance Dimensions 21 r Ceiling -mount horn strobes SpectrAlert Advance Ordering Information 'Model Description Ceiling Horn Strobes PC2R* 2 -Wire Horn Strobe, Standard cd, Red PC2RH 2 -Wire Horn Strobe, High cd, Red PC2W *t 2 -Wire Horn Strobe, Standard cd, White PC2WH* 2 -Wire Horn Strobe, High cd, White PC4R 4 -Wire Horn Strobe, Standard cd, Red PC4RH 4 -Wire Horn Strobe, High cd, Red PC4W 4 -Wire Horn Strobe, Standard cd, White D" 2.25"1 am Ceiling back box skirt Model Description Ceiling Strobes SCR Strobe, Standard cd, Red SCRH Strobe, High cd, Red SCW* Strobe, Standard cd, White SCWH Strobe, High cd, White Accessories BBSC -2 Back Box Skirt, Ceiling, Red BBSCW -2 Back Box Skirt, Ceiling, White TRC -HS Trim Ring, Ceiling, Red TRCW -HS Trim Ring, Ceiling, White Notes: * Add " -P "to model number for plain housing (no'FIRE" marking on cover), e.g., P2R -P. t Add " -SP "to model number for "FUEGO "marking on cover, e.g., P2R -SP. #"Standard cd "refersto strobes that include 15,1 S/75, 30, 75, 95,110, and 115 candela settings. "High cd "refers to strobes that include 135, 150,177, and 185 candela settings. SYSTEM ®2o1 I System Sensor 3825 Ohio Avenue • St. Charles, IL 60174 Prcduas tprc,atlonssumaf1 o,in without nouce.Vlslt systemsensorcom f« SENSOR Phone: 800 SENSOR2 • Eax:630-377-6495 "enter "` "m't' ° ",' "a °aln9tnelacen er5« °+ n :aaw :Wee AMD800500•6/11•W2806 4�� SYSTEM SENSOR° Outdoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert" Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field- selectable candela settings: 15,15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from —40 °F to 151 °F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug -in design with minimal intrusion into the back box -Tamper-resistant construction Aaencv Listinqs SIGNALING :: V.: UL FM MEA 30P1653:187(Ldec,strobes) LISTED approved 7125- 1653:188(horn strobes , 540 I I(chimes, horn strobes, horns) APPROVED chime strobes) 53593 (outdoes and alert strobes) 3023 MEA452 -05-E 71351653:189 (horns, chimes) W-N, A IF s s SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE - printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —407 to 151 °F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field - selectable settings, including candela, automatic selection of 12- or 24 -volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug -in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4 -inch top and bottom conduit entries and 3/4 -inch knock -outs at the back. A screw -in NPT plug with an 0 -ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12- volt -rated notification appliance circuit outputs shall operate between 9 and 17.5 volts, 24 -volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field - selectable candela settings including 15, 15/75, 30, 75, 95,110,115, 135,150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non - temporal (continuous) pattern.These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature —40 °F to 151 IF (-40 °C to 66 °C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range2 8 to 175 V (12 V nominal) or 16 to 33 V (24 V nominal) InputTerminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6" L x 47W x 2.5- D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7 -W x 1.3 -D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA -WBB) 5.7- L x 5.1 -W x 2.0- D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVD501200 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) I L Max. horn Current I!raw (MA Milbj 8 -17.5 Volts 16 -33 Volts 8 -17.5 Volts 16 -33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non Temporal High 57 56 69 75 Non Temporal Medium 42 50 60 69 Non Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 185 NA NA 103 286 258 15 203 221 229 Non Temporal Medium 134 155 44 UL Max. Current Draw (mA DC Input RMS), 2-Wire Horn 8 -17.5 Volts 15 Strobe, 15/75 Standard Candela 16 -33 Volts 15 Range 15/75 (15-115 cd) 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 85 102 163 187 207 216 Non - Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input 299 Non Temporal Medium 219 232 262 267 Non Temporal Low 238 254 291 295 Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 Temporal 103 112 126 181 15 203 221 229 Non Temporal Medium 134 155 44 85 95 110 166 110 189 208 216 Non Temporal Low 132 154 135 80 90 105 161 177 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135-185 cd) 76 83 80 94 16 -33 Volts 4 Non Temporal High 16 -33 Volts 82 88 DC input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Candela Derating 85 Horn Tones and Sound Output Data 92 For K series products used at low temperatures, listed candela Horn and Horn Strobe Output (dBA) ratings must be reduced in accordance with this table. 8 -17.5 16 -33 24-Volt Nominal Strobe Output (cd) Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at -40 °F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 15 Do not use below 32 °F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 1177 185 1 185 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non Temporal High 82 82 88 88 93 92 100 100 5 Non Temporal Medium 78 78 85 85 90 90 98 98 6 Non Temporal Low 75 75 81 81 88 84 96 92 T Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2 -wire horn strobe. AVDW 200 ectrAlert Advance Diagrams 2.5" 3„ Wall -Mount Horn Strobes UM Wall -Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information arproof Back Box Model Wall Horn Strobes --zescription P2RK *t 2 -Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic outdoor back box) P2RHK *t 2 -Wire Horn Strobe, High cd, Red, Outdoor (includes plastic outdoor back box) P2WK *t 2 -Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic outdoor back box) P2WHK *t 2 -Wire Horn Strobe, High cd, White, Outdoor (includes plastic outdoor back box) P4RK1 4 -Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic outdoor back box) P4WK 4 -Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic outdoor back box) P2RHK -120 2 -Wire Horn Strobe, High cd, Red, Outdoor, 120V (includes plastic outdoor back box) Wall Strobes SRK *t Strobe, Standard cd, Red, Outdoor (includes plastic outdoor back box) SRHK *t Strobe, High cd, Red, Outdoor (includes plastic outdoor back box) SWK *t Strobe, Standard cd, White, Outdoor (includes plastic outdoor back box) SWHK *t Strobe, High cd, White, Outdoor (includes plastic outdoor back box) Horns HRKt Horn, Red, Outdoor (includes plastic outdoor back box) Accessories SA -WBB Red Separate Ship, Wall- Mount, Outdoor Back Box, Metal SA -WBBW White Separate Ship, Wall- Mount, Outdoor Back Box, Metal Notes: * Add' -P'to model number for plain housing (no'FIRE° marking on cover), e.g., P21RK -P. t Add' -R'to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. 'Standard cd'refers to strobes that include 15,15/75, 30, 75, 95,110, and 115 candela settings. "High cd'refers to strobes that include 135,150,177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. .SYSTEM ®gall System Sensor �� SENSOR 3825 OhioAvenue•St.Charles,IL60174 Ad —rent produainforject n,i ncldingthelteRwmimoft hisdaUsheet a s Phone: 800- SENSOR2 • Fax: 630- 377 -6495 —rent produttinfo madoginduding/11 later vemon of his da ashee AVDS01200.6/11 •t2813 r NP SERIES - NP7 -12 Reliability is your Security Utilizing the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years of experience in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries. FEATURES • Superb recovery from deep discharge. • Electrolyte suspension system. • Gas Recombination. • Multipurpose: Float or Cyclic use. • Usable in any orientation • Superior energy density. • Lead calcium grids for extended life. • Manufactured World wide. • Application specific designs. Technical Features Sealed Construction Yuasa's unique construction and sealing technique ensures no electrolyte leakage from case or terminals Electrolyte Suspension System All NP batteries utilize Yuasa's unique electrolyte suspension system incorporating a microfine glass mat to retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and there is no free electrolyte to escape from the cells. No gels or other contaminants are added. Control of Gas Generation The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively control the generation of gas during normal use. Low Maintenance Operation Due to the perfectly sealed construction and the recombination of gasses within the cell, the battery is almost maintenance free. Terminals NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown. Operation in any Orientation The combination of sealed construction and Yuasa's unique electrolyte suspension system allows operation in any orientation, with no loss of performance or fear of electrolyte leakage. Valve Regulated Design The batteries are equipped with a simple, safe low pressure venting system which releases excess gas and automatically reseals should there be a build up of gas within the battery due to severe overcharge. Note. On no account should the battery be charged in a sealed container. 4 Q O Faston tab: 187 A Faston tab: 250 D tes a ow o� INCH = MIYJ 250 . W4 INCH = NQvI +ll� 250 6.35 .310 7.90 0.9 .185 4.70 .250 6.35 - -- .124 3.15 .16 4.0 .098 2.50 s .091 0.8 059 1.50 — I .020 0.5 031 0.80 .024 0.50 .004 0.10 A3Y General Specificationf Nominal Capacity (Ah) NP7 -12 20hr to 1 .75vpc 30 °C 7 1 Ohr to 1 .75vpc 20 °C 6.4 5hr to 1.70vpc 20 °C 5.9 1 hr to 1 .60vpc 20 °C 4.2 Voltage 12 Energy Density (Wh.L.20hr) 91 Specific Energy (Wh.kg.20hr) 32 Int. Resistance (m.Ohms) 25 Maximum discharge (A) 40/75 Short Circuit current (A) 210 Dimensions (mm) Length 151 Width 65 Height overall 97.5 Weight (Kg) 2.65 Terminal A/D Layout 4 Terminal Torque Nm - NP SERIES - N P7 -12 Lead Calcium Grids The heavy duty lead calcium alloy grids provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge. Long Cycle Service Life Depending upon the average depth of discharge, over a thousand discharge /charge cycles can be expected. Float Service Life The expected service life is five years in float standby applications. Separators The use of the special separator material provides a very efficient insulation between plates preventing inter -plate short circuits and prohibiting the shedding of active materials. CYCLIC RECHARGE REGIME td _ s �` 1 fhArOe Vd>rw 9� � ChaagE HW.aye 14 m P' f3 u� L9i 0.1 '`0 �GLrtOMTfiPan� � 12 �_ .OA7C Amps 1 ii aA5 zs� ° 1 tr NP DISCHARGE CHARACTERISTICS CURVES AT 252C (77 2F) (V) 'Vi Np C = Gw , capacity as stated pn each battery In Ah FOR 12V FOR 6V BATTERY BATTERY NP AT 25-0 (77-F) 13.0 8S 12.0- 6A - -- - C1 me SS - 4 10.0 5A 8.0 4A 1 20 MP4UTES DISCHARGE TIME HOURS FLOAT SERVICE LIFE NP RANGE (AH%) TESTING VOLTAGE AMBIENT TEMPERATURE E W0C(68'F TO 72°F) 120 n U 100 U_ 80 O W 60 2E jg 20 a< 0 1 2 3 4 LIFE (YEARS) Data Sheet u3 u¢ 05M 025CA- 2.275VPC CONSTANT VOLTAGE CiARCNG Long shelf Life The extremely low self discharge rate allows the battery to be stored for extended periods up to one year at normal ambient temperatures with no permanent loss of capacity. Operating Temperature Range The batteries can be used over a broad temperature range permitting considerable flexibility in system design and location. Charge — 15 °C to 50 °C Discharge — 20 °C to 60 °C Storage — 20 °C to 50 °C (fully charged battery) SELF DISCHARGE CHARACTERISTICS u3 u¢ 05M 025CA- 2.275VPC CONSTANT VOLTAGE CiARCNG g ¢ 0 C (32'F) AT Mr; I+tB °Ft K 140 1V1 C 0,?3 7.54 - , GIARGED VOUR.IF_'.. _. 15.0 too a - WC OWF) 7,00 ir° CNARGE V-1AGC 14.0 20'C 1168 °F1 0.15 AFiF:R tOIP% I)I.Qf:HARGF 3,0 5 010 i A TER 50, DISCHARGE 40 2 z• A.00 ! f i 40°C (1Od• i 186 6 9 12 15 1F STORAGE TIME (MONTHS) FLOAT CHARGE CHARACTERISTICS u3 u¢ 05M 025CA- 2.275VPC CONSTANT VOLTAGE CiARCNG g ¢ 1".1 i.CAy (VI AT Mr; I+tB °Ft K 140 1V1 120 0,?3 7.54 - , GIARGED VOUR.IF_'.. _. 15.0 too - 80 7,00 ir° CNARGE V-1AGC 14.0 80 0.15 AFiF:R tOIP% I)I.Qf:HARGF 3,0 010 d 1 A TER 50, DISCHARGE 40 A.00 ! f 12.0 a0 OJD9 Y y HARdJUG CURRENT A 0 2 4 6 8- t0 12 ,4 S5 18 20 C.ARGING INC. PKXIR. : TYPICAL DISCHARGE CHARAC- TERISTICS NP RANGE CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE TESTING CONDITIONS: DISCHARGE CURRENT. O.17C Amp. (F.V 1.7V /CELL CHARGING CURRENT 0.090 AMP, CHARGING VOLUME: IPS %OF DISCHARGED CAPACITY (AH°4) — AMBIENT TEMPERATURE: M0 C TO 2M tWF TO T]"F) ,m a U O t00% SO.6 30%DEPT DOD DOD OFDtSCH RGF U o. ° zoo +oo as o00 ,u1c +2C0 ,400 NUMBER OF CYCLES Yuasa Battery Inc. Distributed by 2901 Montrose Ave Laureldale, PA 19605 www.yuasabatteries.com Registered number 1548820 VU AS A r (I8 %_at.INO NI I -1_ anuary PRODUCT DATA SHEET Controlled Document - Engineering Drive AW �7 Nr - _- t „�AW 1530 Shields Drive -.0000— AMW Waukegan, IL 60085 A7101"II &! /e %_ Toll -Free (800) 323 -9355 Fax: (847) 689 -1192 PART NUMBER: 81402 DESCRIPTION: 1412 SOLID FPLP CABLE CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424, NEC Article 760. APPLICATION: Fire Alarm Power Limited Circuit Cable Used in Plenum Applications Construction Parameters: Cable Cross - Section Conductor 14 AWG Bare Copper Stranding Solid Insulation Material Low Smoke PVC Insulation Thickness 0.008" Nom. Insulated Conductor Diameter 0.080" Nom. ID Number of Conductors 2 Lay Length 5.00" Nom. Jacket Material Low Smoke PVC Jacket Thickness 0.017" Nom. Overall Cable Diameter 0.194" Nom. Approximate Cable Weight 36.2 Lbs /1 M' Nom. Flame Rating NFPA 262 Steiner Tunnel Smoke and Flame Test Electrical & Enviromental Properties: Temperature Rating -20 °C to 75 0C Operating Voltage 300 V RMS Max. Capacitance Between Conductors @ 1 KHz 44 pF /ft Nom. Capacitance Between Conductors to Shield @ 1 KHz - - - -- DC Resistance per Conductor @ 200C 2.54 Ohms /1 M' Nom. Insulation Colors Black Red Jacket Color Red (Other colors available for minimum order) Legend (Surface Ink Print) COLEMAN CABLE 81402 14 AWG 2/C (ETL)US (ETL CODE) TYPE FPLP 75C Testing Requirements: Spark Testing (Jacket and Insulation): 2KVAC (100% of manufactured cable) Hypot Testing: 2.5KVDC (1 out of 10 reels) Continuity: 100% (every packaged reel) This product complies with European Directive 2002/95/EC (ROHS) On special orders, the customer will accept all factory lengths and +/- 10 percent of total order requested. The information presented here is, to the best of our knowledge, true and accurate. Since conditions of use are beyond Coleman Cable's control all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer. The sale of products(s) is conditioned upon acceptance of a purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman Cable's standard warranty. Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Coleman Cable. Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable. Customer Name_ Customer Approval Specification Issue Date: July 19, 2006 Date Signed 1- 800 - 323 -9355 (Phone) Designed By: PEP 1- 847 -689 -1192 (Fax) 81402 0 2006 Coleman Cable, Inc. PRODUCT DATA SHEET PART NUMBER: 81404 DESCRIPTION: 14/4 SOLID FPLP CONSTRUCTION: This cable consists of four bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424, NEC Article 760. APPLICATION: Fire Alarm Power Limited Circuit Cable Used in Plenum Applications Controlled Document - Engineering Drive 1530 Shields Drive Waukegan, IL 60085 Toll -Free (800) 323 -9355 Fax: (847) 689 -1192 Construction Parameters: Cable Cross - Section Conductor 14 AWG Bare Copper Stranding Solid Insulation Material Low Smoke PVC Insulation Thickness 0.008" Nom. Insulated Conductor Diameter 0.080" Nom. Number of Conductors 4 Lay Length 5.00" Nom. Jacket Material Low Smoke PVC Jacket Thickness 0.017" Nom. Overall Cable Diameter 0.227" Nom. Approximate Cable Weight 65.0 Lbs /1M' Nom. Flame Rating NFPA 262 Steiner Tunnel Smoke and Flame Test Electrical Properties: Temperature Rating -20 0C to 75 °C Operating Voltage 300 V RMS Max. Capacitance Between Conductors @ 1 KHz 44 pF /ft Nom. Capacitance Between Conductors to Shield @ 1 KHz - - - -- DC Resistance per Conductor @ 20 °C 2.54 Ohms /1 M' Nom. Insulation Colors Black Red Green Yellow Jacket Color Red (Other colors available for minimum order) Legend (Surface Ink Print) COLEMAN CABLE 81404 14 AWG 4/C (ETL)US (ETL CODE) TYPE FPLP 75C This product complies with European Directive 2002/95/EC (RoHS) On special orders, the customer will accept all factory lengths and +/- 10 percent of total order requested. The information presented here is, to the best of our knowledge, true and accurate. Since conditions of use are beyond Coleman Cable's control all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer. The sale of products(s) is conditioned upon acceptance of a purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman Cable's standard warranty. Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Coleman Cable. Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable. Customer Name_ Customer Approval Specification Issue Date: November 21, 2005 Date Signed 1-800- 323- 9355(Phone) Designed By: PEP 1- 847-689 -1192 (Fax) 81404 © 2005 Coleman Cable, Inc. TO, '� 0 /e %_ PRODUCT DATA SHEET Controlled Document - Engineering Drive PART NUMBER: 81602 DESCRIPTION: 16/2 SOLID FPLP FT6 CABLE CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424, NEC Article 760. APPLICATION: Fire Alarm Power Limited Circuit Cable Used in Plenum Applications 1530 Shields Drive Waukegan, IL 60085 Toll -Free (800) 323 -9355 Fax: (847) 689 -1192 Construction Parameters: Cable Cross - Section Conductor 16 AWG Bare Copper Stranding Solid Insulation Material Low Smoke PVC Insulation Thickness 0.008" Nom. Insulated Conductor Diameter 0.067" Nom. ID Number of Conductors 2 Lay Length 5.00" Nom. Jacket Material Low Smoke PVC Jacket Thickness 0.014" Nom. Overall Cable Diameter 0.162" Nom. Approximate Cable Weight 24.5 Lbs /1 M' Nom. Flame Rating NFPA 262 Steiner Tunnel Smoke and Flame Test Electrical & Enviromental Properties: Temperature Rating -20 °C to 75cC Operating Voltage 300 V RMS Max. Capacitance Between Conductors @ 1 KHz 40 pF /ft Nom. Capacitance Between Conductors to Shield @ 1 KHz - - - -- DC Resistance per Conductor @ 20 0C 4.02 Ohms /1M' Nom. Insulation Colors Black Red Jacket Color Red (Other colors available for minimum order) Legend (Surface Ink Print) COLEMAN CABLE 81602 16 AWG 2/C C(ETL) US (ETL CODE) TYPE FPLP 75C -- TYPE CMP FT6 This product complies with European Directive 2002/95/EC (ROHS) On special orders, the customer will accept all factory lengths and +/- 10 percent of total order requested. The information presented here is, to the best of our knowledge, true and accurate. Since conditions of use are beyond Coleman Cable's control all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer. The sale of products(s) is conditioned upon acceptance of a purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman Cable's standard warranty. Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Coleman Cable. Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable. Customer Name Date Signed Customer Approval Specification Issue Date: July 19, 2006 1 -800- 323 -9355 (Phone) Designed By: PEP 1 -847- 689 -1192 (Fax) 81602 0 2006 Coleman Cable, Inc. PRODUCT DATA SHEET � = ,. Controlled Document - Engineering Drive w EZ _ — if 1530 Shields Drive 1.0000— '00now— AW Waukegan, IL 60085 &/0/"// 4&AIe %. Toll -Free (800) 323 -9355 Fax: (847) 689 -1192 PART NUMBER: 81802 DESCRIPTION: 18/2 SOLID FPLP FT6 CABLE CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424, NEC Article 760. APPLICATION: Fire Alarm Power Limited Circuit Cable Used in Plenum Applications Construction Parameters: Cable Cross - Section Conductor 18 AWG Bare Copper Stranding Solid Insulation Material Low Smoke PVC Insulation Thickness 0.006" Nom. Insulated Conductor Diameter 0.052" Nom. 10 Number of Conductors 2 Lay Length 5.00" Nom. Jacket Material Low Smoke PVC Jacket Thickness 0.014" Nom. Overall Cable Diameter 0.132" Nom. Approximate Cable Weight 16.9 Lbs /1 M' Nom. Flame Rating NFPA 262 Steiner Tunnel Smoke and Flame Test Electrical Properties: Temperature Rating -20 0C to 75 °C Operating Voltage 300 V RMS Max. Capacitance Between Conductors @ 1 KHz 41 pF /ft Nom. Capacitance Between Conductors to Shield @ 1 KHz - - - -- DC Resistance per Conductor @ 20 °C 6.32 Ohms /1M' Nom. Insulation Colors Black Red Jacket Color Red (Other colors available for minimum order) Legend (Surface Ink Print) COLEMAN CABLE 81802 18 AWG 2/C C(ETL) US (ETL CODE) TYPE FPLP 75C -- TYPE CMP FT6 This product complies with European Directive 2002/95/EC (RoHS) on special orders, the customer will accept all factory lengths and +/- 10 percent of total order requested. The jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, true and accurate. Since conditions of use are beyond Coleman Cable's control all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer. The sale of products(s) is conditioned upon acceptance of a purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman Cable's standard warranty. Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Coleman Cable. Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable. Customer Name_ Customer Approval Specification Issue Date: July 19, 2006 1- 800 - 323 -9355 (Phone) Designed By: PEP 1- 847 -689 -1192 (Fax) 81802 0 2006 Coleman Cable, Inc. PRODUCT DATA SHEET Controlled Document - Engineering Drive _� _— 1530 Shields Drive AWW­� Toll-Free 3 Waukegan, 5 -Free (800) 323 -93-93 55 Fax: (847) 689 -1192 PART NUMBER: 81804 DESCRIPTION: 18/4 SOLID FPLP FT6 CABLE CONSTRUCTION: This cable consists of four bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424, NEC Article 760. APPLICATION: Fire Alarm Power Limited Circuit Cable Used in Plenum Applications Construction Parameters: Cable Cross - Section Conductor 18 AWG Bare Copper Stranding Solid Insulation Material Low Smoke PVC Insulation Thickness 0.006" Nom. Insulated Conductor Diameter 0.052" Nom. Number of Conductors 4 Lay Length Parallel Jacket Material Low Smoke PVC Jacket Thickness 0.014" Nom. Overall Cable Diameter 0.154" Nom. Approximate Cable Weight 28.6 Lbs /1 M' Nom. Flame Rating NFPA 262 Steiner Tunnel Smoke and Flame Test Electrical Properties: Temperature Rating -20 0C to 75 °C Operating Voltage 300 V RMS Max. Capacitance Between Conductors @ 1 KHz 41 pF /ft Nom. Capacitance Between Conductors to Shield @ 1 KHz - - - -- DC Resistance per Conductor @ 20 0C 6.32 Ohms /1M' Nom. Insulation Colors Black Red Green Yellow Jacket Color Red (Other colors available for minimum order) Legend (Surface Ink Print) COLEMAN CABLE 81804 18 AWG 41C C(ETL) US (ETL CODE) TYPE FPLP 75C -- TYPE CMP FT6 This product complies with European Directive 2002/95/EC (RoHS) On special orders, the customer will accept all factory lengths and +/- 10 percent of total order requested. The jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, true and accurate. Since conditions of use are beyond Coleman Cable's control all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer. The sale of products(s) is conditioned upon acceptance of a purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman Cable's standard warranty. Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Coleman Cable. Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable. Customer Customer Approval Specification Issue Date: November 21, 2005 Date Signed Designed By: PEP 1-800- 323 -9355 (Phone) 81804 © 2005 Coleman Cable, Inc. 1 -847- 689- 1192(Fax)