Loading...
20160174 Permit Pkg 04132016City of Yelm Community Development Department Building Division Phone: (360) 458 -8407 Fax: (360) 458 -3144 Applicant: Name: THURSTON CO FIRE #2 (1) Address: P.O. BOX 777 YELM WA 98597 Property Information: Site Address: 7f19 MII I RI7 RF Assessor Parcel No.: 21725110600 Contractor Information: Name: PIONEER FIRE AND SECURITY Address: DAVE PO BOX 597 OLYMPIA WA 98540 Contractor License No.: PIONEFS963CC Permit No.: 20160174 Issue Date: 4/13/2016 (Work must be completed within 180 days) Phone: Owner: THURSTON CO FIRE Subdivision: Lot: Phone: Expires: 6/14/2012 Project Information: Project: FIRE ALARM Description of Work: REPLACE EXISTING FIRE PANEL WITH NEW PANEL Sq. Ft. per floor: First Heat Type (Electric, Gas, Other): Second Third Garage Basement Fees: Item FIRE ALARM Contractor PIONEER FIRE AND SECURITY TOTAL FEES: Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning' and land subdivision, and in addition, all covenants, easements and restric-Nons of record. If applying as a contractor, I further certify that I am currently registered in the State of Washington. Signature / r Date - — c ,( Firm Fees $ 160.46 $ 160.46 OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: City of Yolm (36 ) 458 -3244 REC #: 00228137 OPER: CO TERM: REF #: 16847 PAID BY: 4/13/2016 8 :09 AM 001 TRAN: 33.0000 BUILDING PERMITS 20160174 160.46CR THURSTON CO FIRE #2 (I) 709 MILL RD SE FA TENDERED: APPLIED: 160.46CR 160.46 CHECK 160.46- CHANGE: pp CITY OF YELM COMMERCIAL BUILDING PERMIT APPLICATION FORM Project Address: i J 1 4 A--d -S Parcel #: Zoning; Current Use: F, r J 6, I-''o- Proposed Use: R-, e- New Construction ❑ Re -Model / Re -Roof / Tenant Improvement Plumbing ❑ Mechanical X Fire Prevent/Suppress /Alarm ❑ Other Project Description /Scope of Work: 12a max- 1 Project Value:t,;; 2,0c) Building Area (sq. ft) Parking Garage Building Height 1s' Floor 2nd Floor P Floor Are there any environmentally sensitive areas located on the parcel? _ completed environmental checklist must accompany permit application. a ftlAi 'f= 1141)I : 'T (!V - -5Mn F. r� ADDRESS o `- 11 r-o-zi Si; EMAIL CITY d:Ll n STATE W A ZIP 9d'S 1-7 TELEPHONE l�O --Afo LICENSE # ADDRESS EMAIL CITY STATE ZIP TELEPHONE If yes, a �N�€�A� ADDRESS CITY t✓� " CONTRALTO LICENSE # P /y�v�'T- 9b�CEXP DATECITY LICENSE # 7 ( - t�sa'S PI3iNG TELEPHONE ADDRESS EMAIL CITY STATE ZIP - FAX CONTRACTOR'S LICENSE # -- EXPDATE =CI-TY LIGENSE -# - - - -- • -- - - MIEGk,Wp a TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # Copy of City Mitigation documentation (TFC). I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City of Y@Im. ` Applicant's Signature Date Owner/ Contractor/ Owner's Agent/ Contractor's Agent/ Tenant (Please circle one.) All permits are non - transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days (360) 458 -3835 105 Yelm Ave W (360) 458 -3144 FAX Yelm, WA 98597 www.6.ye1m.wa.us Pioneer Fire & Security, Inc. • PO Box 597 E. Olympia, WA 98540 -0597 Pioneer Fire &Security, Inc. 3 -22 -2016 Yelm Fire Station #21 709 Mill Road SE Yelm, WA 98597 Dear Rod: This letter is to inform you that we will be replacing the existing fire alarm panel and annunciator panel with new replacement devices. Please let me know if you have any questions. Sincerely, Asher Cabe Pioneer Fire & Security, Inc. (0) 360 -491 -8141 (C) 360 -507 -1571 (F) 360- 491 -6555 service@pioneerfire.net Pioneer Fire & Security, Inc. SILENT KNIGHT by Honeywell Model 5208 Fire Alarm Control Panel with Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK -5208 is a microprocessor based control panel with built -in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK -5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK -5208 delivers the performance to handle your installation. Features Built -in synchronization for • 10 zones, 8 Class B (Style B) and 2 Class A (Style D) or Class B (Style B) zones, expandable to 30 zones • Supervised zone expanders and 1/0 modules can be mounted remotely from the main control panel • Event History Buffer (150 events) with date /time stamp • All zones are compatible with 2- or 4 -wire detectors • 8 selectable /programmable output patterns for notification appliance circuits • Built -in Digital Alarm Communicator Transmitter (DACT) • 4 Notification Appliance Circuits • 4 programmable general purpose relays • Programmable smoke verification, pre -alarm delay, cross zoning and enhanced verification mode features that can help minimize false alarms • Programmable from the built -in control panel touchpad, remote annunciator, or Windows® SKSS downloading software • Direct connect port for on -site up /downloading with Windows® SKSS downloading software • Built -in walk test feature • Single or dual interlock water releasing capability • Plex door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions • Programmable AC trouble relay appliances from AMSECO , Gentex ®, Faraday, System Sensor®, and Wheelock° • Programmable date settings for Daylight Saving Time • Clock source setting options for 50 Hz, 60 Hz, or internal (uses the panel's internal clock) Specifications Operating Voltage: 24 VDC Primary AC: 120 Vrms @ 60Hz, 2A Total DC Load: 6 Amp Current Draw: Standby: 140 mA Alarm: 460 mA Flush Mounting Dimensions: Height: 24.75" (62.9 cm) Width: 14.5" (36.8 cm) Depth: 3- 7/16" (8.73 cm) with 5/8" protruding Overall Dimensions: Height: 26 -3/8" (67 cm) Width: 17- 3/16" (43.66 cm) Total Depth: 4" (10.16 cm) Operating Temp: 32° to 120° F (0° to 49° C) Humidity: 10 - 93% noncondensing Optional Accessories • SK -5235 LCD Remote Annunciator • SK -5217 10 Zone Expander (2 max. per system) • SK -5280 Status Display Module (8 max. per system) • 5220 Direct Connect Module • 5824 Serial /Parallel Printer Interface Module • SKSS Downloading Software SK -5208 • Plex -2 Door Option • SK -SCK Seismic Compliance Kit Listings and Approvals • UL Listed • CSFM Listed • MEA approval 429 -92 -E Vol. XIII • OSHPD (CA) OSP- 0065 -10 Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled /disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 *--Egg Direct Connect 2 Class A (Style D) or Class B (Style B) Initiation Circuits 8 Class B (Style B) Initiation Circuits Telephone Line 2 For On -Site Programming r Programmable Form C Relays Notification Appliance Circuits _♦ 5235 Remote Annunciators ♦ SBUS Devices 5280, 5217, & 5824 This document is not intended to be used for installation purposes. We try to MADE IN AMERICA SILENT keep our product information up -to -date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350318 Rev E subject to change without notice. For more information, contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472 -1610 Phone: (800) 328 -0103, Fax: (203) 484 -7118. For Technical support, Please call 800 4 Us ,111111 - I To AC 46 -6444. www.silentknight.com Karen Bennett From: Justin Leech [JustinL @pioneerfire.net] Sent: Tuesday, March 22, 2016 4:16 PM To: Karen Bennett Subject: RE: City of Yelm Commerical Building Applicatin Attachments: Yelm Fire Station #21 TI Letter.pdf; Yelm Permit Application.pdf; 5208 Data Sheet.pdf; sk5235spec.pdf Karen, Here are the files for the Fire Station. Let me know if you need anything else. Thank you, Justin Leech Pioneer Fire & Security, Inc. Ph.:360 -491 -8141 Cell:360 -584 -5764 Fax:360- 491 -6555 JustinL gpioneerfire.net From: Karen Bennett [mailto: Karen B @ci.yelm.wa.us] Sent: Tuesday, March 22, 2016 3:33 PM To: Justin Leech <JustinL@pioneerfire.net> Subject: City of Yelm Commerical Building Applicatin Per our earlier conversation, attached you will find the commercial permit application. Karen T. Bennett 105 Yelm Ave W Yelm, WA 98597 (360)458 -3835 karenb p ci. uelm. wa. us of TBM ^ ®R a re