Loading...
20160134 Permit Pkg Mechanical 02292016City of Yelm Community Development Department Building Division Phone: (360) 458 -8407 Fax: (360) 458 -3144 Applicant: Name: RICK CHRISTENSEN Address: 11915 CLEAR LAKE RD EATONVILLE WA 98328 Property Information: Site Address: 16605 106TH AVE SE Assessor Parcel No.. 64303400502 Contractor Information: Name: RICK CHRISTENSEN Address: 11915 CLEAR LAKE RD EATONVILLE WA 98328 Contractor License No.: Project Information: Project: COMMERCIAL REMODEL Description of Work: 3740 RESTAURANT TI Sq. Ft. per floor: First 3740 Second Third Garage Basement Fees: Item BUILDING MECHANICAL PLUMBING Permit No.: 20160134 Issue Date: 2/19/2016 (Work must be completed within 180 days) Phone. Owner: RICK CHRISTENSEN Subdivision: Lot: Phone: t Expires: 0 /00 /0000 Heat Type (Electric, Gas, Other): HEAT PUMP Contractor RICK CHRISTENSEN SUNSET AIR INC - 2/29/2016 AFFORDABLE PLUMBING TOTAL FEES: Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and resa?, ctions of record. If applying as a contractor, I further certify that I m currently registered in t e e Washington Signature ) Date Firm Fees $49,100.40 $ 56.00 $ 132.00 $ 49,288.40 OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: City of selm44 (360i . PM REC#: 00223883 2/20/2016 1.33 GPER: CO TERM: 001 REF #: PAID BY ACCT #: XXXXXXXXXXXXXXXXXXX AUTH #: 029877 TRAN #: 000000000137 Pi TRAN: 33.0000 BUILD156 ooCR TS 20160134 CHRISTENSEN, RICK 16605 106TH AVE SE MECH CARD TENDERED: 56.00 CREDIT 56 APPLIED: :00 - --'' CHANGE: p 00 l� CITY OF YELM / COMMERCIAL BUILDING PERMIT APPLICATION FORM Project Address: 164 6 Zoning; Current Use: Proposed Use: ❑ New Construction Re -Model / Re -Roof / Tenant Improvement ❑ Plumbing Mechanical -! FireLLPrevent/Suppress /Alarm // Other Project Description/Scope of Work: Z AM / %010 K,.,fb �°'✓� Project Value: Building Area (sq. ft) Parking Garage 1" Floor 2nd Floor 3rd Floor Building Height Are there any environmentally sensitive areas located on the parcel? If yes, a completed environmental checklist must accompany permit application. BUILDING OWNER /TEN,P T NAME: 1 vc ► ►, ADDRESS L if_ EMAIL a P.C. aiy&V;,�,y e �►�ri��2 �.C.•� CITY / /./ STATE &IA -ZIP C1f2?_Z TELEPHONE 23-3-- ARCHITECT /ENGINEER LICENSE # ADDRESS EMAIL CITY STATE ZIP TELEPHONE GENERAL CONTRACTOR L TELEPHONE 740 S6 y«j 41 ADDRES 2!O !vD EMAIL KLS L S*��rt� •cevh CITY STAT ZIP D FAX CONTRA S LICENSE #Z uXP DATE 'fGITY LICENSE # PLUMBING CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # MECHANICAL CONTRACTOR G ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # Copy of City Mitigation documentation JFC). I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City of Yelm. Ap is u� Date O r / ractor / wner's Age / Contractor's Agent / Tenant (Please circle one.) All permits are non - transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 da (360) i 35 - -- -:: • (360) 10-31 14 FAX www.ci.yelm.wa.us 105 Yelm Ave W Yelm, WA 98597 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary MECH-SUM 2012 W ashinaton State Enerov Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address 11915 CLEAR LAKE RD S Date 2/18/2016 EATONVILLE, WA 98328 For Building Dept. Use Applicant Name: SUNSET AIR, INC Applicant Address: 5210 LACEY BLVD SE, LACEY, WA Applicant Phone: 360 -456 -4956 Project Description Briefly describe mechanical system type and features. 21 Includes Plans INSTALL 2 RTU AND NEW RESTROOM EXHAUST Drawings must contain notes requiring compliance with commissioning provisions per Section C408 Compliance Option Simple System 0 Complex System 0 Systems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Coolin g Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacit/ Btu /h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exception 6 Heat Recovery Y/N SEE SCHEDULE Heatin g Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacit/ Btu /h OSA cfm or Econo? Input Btuh Output Btuh Efficiency° Heat Recovery Y/N SEE SCHEDULE Fan E ui ment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM SP' HP /BHP Flow Controls Location of Service SEE SCHEDULE Service Water Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Input Capacity Sub - Category EF7 Location of Service N/A ' If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Economizer exception number per 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Project Address 11915 CLEAR LAKE RD S Date 2/18/2016 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH -CHK pages. Applicability Code Section Code Provision Information Required Location Building Department (yes,no,na) on Plans Notes GENERAL PROVISIONS Equipment Sizing & Performance Load calculations performed per ASHRAE Std 183 or equivalent per na C403.2.1 Load calculations Chapter 3 na Equipment and system Output capacity of heating and cooling equipment and systems do not n C403.2.2 sizing exceed calculated loads note exceptions taken na C403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical Sched Y ventilation is capable of being reduced to minimum requirement per IMC C403.2.3 & Provide equipment schedules or complete MECH -SUM tables with type, C403.2.3.2 Equipment minimum efficiency capacity, efficiency, test standard (or other efficiency source) for all Sched Y & mechanical equipment C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note Sched Y except. C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table na C403.2.10.1 1 na C403.2.10.3 fan Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency na & C403.2.13 Fractional hp motors re q. na C403.2.3 Maximum air cooled chiller Indicate air - cooled chiller capacity does not exceed air - cooled chiller limit na na capacity Non - standard water - cooled Full -load and NPLV values for water - cooled centrifugal chiller adjusted for na C403.2.1 chillers non - standard operational conditions na Centrifugal fan cooling Large capacity cooling towers with centrifugal fan(s) meet efficiency na 403.2.12.1. towers requirements for axial fan open circuit cooling towers na C403.2.3 d air furnace and unit Indicate intermittent ignition or IID, flue /draft damper & jacket loss Sched Y heaters C403.2.3.3 Packaged electric List equipment required to be heat pumps on schedule na na heatin /coolin q equipment Indicate method of humidification (note requirements for systems with na C403.2.3.4 Humidification na economizer HVAC System Controls & Criteria C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including FPI n Y perimeter systems Heat pump supplementary Indicate staged heating (compression /supplemental) & outdoor lock -out na C403.2.4.1.1 heat temp na C403.2.4.2 Setpoint overlap Indicate 5 °F deadband minimum for systems controlling both heating & Sched Y deadband cooling C403.2.4.3 Automatic setback and Indicate zone t -stat controls with required automatic setback & manual Sched Y shutdown override C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load Sched C402.4.5.2 Dampers Indicate location of OSA, exhaust, relief and return air dampers; include FPI n Y & AMCA rated leakage and control type motorized or gravity; note na C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls na na C403.2.4.5 Snow melt systems Indicate shut -off controls based on outdoor conditions na C403.2.4.6 heating Indicate modulating or staged control Sched Y �Cormbmenin C403.2.4.7 Group R1 hotel /motel Indicate method for guest room automatic setback & set -up of 5 °F na s stems minimum na 403.2.4.8 / E Group R2 /R3 dwelling unit Indicate 5 -2 programmable thermostats in primary spaces with minimum na systems of two setback periods; note exceptions taken na C403.2.5.1 Demand controlled Indicate high- occupancy spaces and systems requiring DCV Sched C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or na alternate means provided to automatically reduce OSA when partially na Enclosed loading Indicate enclosed loading dock and enclosed parking garage ventilation na C403.2.5.3 dock/parking garage system activation and control method na ventilation na C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make -up air, indicate make -up air source na and conditioning method Indicate lab exhaust systems requiring heat recovery, method & efficiency; C403.2.5.4.2 Laboratory exhaust systems or alternative method taken (VAV, semi - conditioned makeup, or CERM na calculation ) na Energy recovery - Indicate ventilation systems requiring ER, method & efficiency; note na C403.2.6.1 ventilation systems exceptions na na C403.2.6.2 Energy recovery - Indicate on -site steam heating systems requiring energy recovery 9 y q g gy ry na condensates stems C403.2.6.3 Energy recovery - Indicate remote refdg. condensers requiring ER and use of captured na condensers stems energy na Mechanical Permit Plans Checklist - Page 2 of 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised .rune 2013 Project Address 11915 CLEAR LAKE RD S Date 2/18/2016 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define pr int area in Excel priorto rintin MECH -CHK pages. Applicability Code Section Code Provision Information Required Location Building Department (yes,no,na) on Plans Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued Variable flow control - Indicate fan & pump motors requiring VF control & method (VSD or equiv na C403.2.12 fans/pumps controls na C403.2.12.1 Variable flow control - Indicate cooling tower fans requiring variable flow control and method na na coolin towers C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and na cooling demand; or exception taken na C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 na btuh na Identify all DDC system input/output control points and indicate capability na C403.2.4.10 DDC system capabilities for trendina and demand response setooint ad iustment na Ducting Systems C403.2.7.1 Duct construction Indicate all ductwork constructed and sealed per IMC, C402 leakage Sched y & requirements and IBC vapor retarder requirements 403.2.7.3.1- Duct pressure Identify location of low, medium and high pressure ductwork on plans Sched y classifications C403.2.7.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans; provide na test test results to'urisdiction when completed na y 403.2.7.1 / fuct insulation Indicate R -value of insulation on ductwork Sched Piping Systems na C403.2.8 Piping insulation Indicate R -value of insulation on piping na na C403.2.8.1 Piping insulation exposed to Indicate method of protection from damage /degredation na weather SIMPLE SYSTEMS Qualifying Systems C403.3 Qualifying single zone Verify unitary or packaged equipment does not exceed capacity limits, Sched y systems does not have active humidification or simultaneous heating/cooling na C403.3 Qualifying 2 -pipe heating Verify 2 -pipe heating -only system does not exceed capacity limits na s stems na C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 na Simple System Economizers C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip Sched y sched. y C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception Sched C403.3.1.1.3 economizer high limit Indicate high limit shut -off control method per Table C403.3.1.1.3(2) Sched y controls C403.1.1.2 Integrated air economizer Indicate capability for partial air economizer operation for systems with na o eration ca acit > 65,000 btuh na na C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with na x f COMPLEX SYSTEMS Complex System Economizers na C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip na sched. C403.4.1.4 Economizer heating system Verify control method of HVAC systems with economizers does not na impact increase building heating energy usage during normal operation na C403.4.1.3 Integrated economizer Indicate capability for partial economizer operation for air or water econo na operation systems na Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50 °F db /45 °F na wb OSA na C403.4.1.2 Water economizer Indicate precooling coils and heat exchangers do not exceed pressure na maximum pressure drop drop limit na na C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with na exceotion(s) Lrner SUBMITTAL Protect Mariuchi Restaurant Date Friday, February 12, 2016 Table Of Contents Project: - -Untitled12 02/12/201( Prepared By: 12:19PN 6.0 Tons .......................................................................................................................................... ............................... 3 UnitReport ................................................................................................................................................................. ..............................4 CertifiedDrawing ....................................................................................................................................................... ............................... 5 PerformanceSummary .............................................................................................................................................. ............................... 8 UnitFeature Sheet .................................................................................................................................................. ............................... 12 SpecSheet .............................................................................................................................................................. ............................... 13 Packaged Rooftop Builder 1.39y Page 2 of 13 6.0 Tons Project: — Untitled12 02/12/201( Prepared By 12.19PM 6.0 Tons Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.39y Page 3 of 13 Unit Report For 6.0 Tons Project: — Untitled12 02/12/201E Prepared By: 12:19PN/ Unit Parameters Dimensions (ft. in.) & Weight (lb.) * ** Unit Model: ........................ 48TCDA07A2A5 -OAOAO Unit Length: ......................................... 6' 2.375" Unit Size: ................................................ 07 (6 Tons) Unit Width: .................................................. 3' 8.. Volts-Phase-Hertz: ..................................... 208-3-60 Unit Height: ......................................... 3' 5.375" Heating Type: ..................................................... Gas Total Operating Weight:...................... 712 lb Duct Cfg :............ Vertical Supply/ Vertical Return Low Heat Weights and Dimensions are approximate. Weight Round Tube Plate Fin Coils does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Lines and Filters Description Gas Line Size: ..................................................... 1/2 Condensate Drain Line Size: .............................. 3/4 Return Air Filter Type: ........................... Throwaway Return Air Filter Quantity: ....................................... 4 Return Air Filter Size: .............................. 16 x 16 x 2 Unit Configuration Medium Static Option (Belt Drive) AI /Cu - AI /Cu Base Electromechanical Controls Standard Packaging Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500 -089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDA07A2A5 -OAOAO Rooftop Unit 2 Base Unit Medium Static Option Belt Drive) None None Accessories ECD- SRT12SA -D2EH Ultra LOW LEAK - Vertical EconoMi$er X with solid -state W7220 controller 2 Packaged Rooftop Builder 1.39y Page 4 of 13 cci Qi o n C) m N 11111 � m rp Igo L 4m O Milo, LZ moo, .6n! 12 7 0 LO J. N 0 v 0 0 a) IL ze; n SV9 11111 � m rp Igo L 4m O Milo, LZ moo, .6n! 12 7 0 LO J. N 0 v 0 0 a) IL N O k— O cfl L L L V oa N �2 N N 0 N N C > 2 -p N U � m n o a� a`a` 0 W � ggs °a a= - DVS V IIW e_ O - _ w � c'J 3 o O O v V o H a Di o o o -- 10 MU _ _ O M 0 (9 N 0) m a- M r L M:3 W Q 0 0 0 ca Y U ca U) c 0 F- CD 0 CD O 0 16 0 QL ZT 70 In E E, F E 3t A E E u E — E E E E oo E E :E E E I I I I 0 r- a) n Cl? >1 0') E E, F E 3t A E E u E — E E E E oo E E :E E E I I I I 0 r- a) n Cl? >1 0') Performance Summary For 6.0 Tons Project: --Untitled 12 02/12/201( Prepared By: 12:19PIy Part NumberA8TCDA07A2A5 -0A0A0 ARIEER :............................................................................................ ............................... ..........................11.00 IEER:................................................................................................... ............................... ...........................11.2 F Base Unit Dimensions ............................... ........................... 77.9 F UnitLength: ............................................................................................................................................. 74.4 in UnitWidth: .............................................................................................................................................. 44.0 in UnitHeight: ............................................................................................................................................. 41.4 in Operating Weight ............................... ........................... 54.0 F BaseUnit Weight: .................................................................................................................................... 652 lb Medium Static Option (Belt Drive): ............................................................................................................. 10 lb Accessories 59.61 MBH Ultra LOW LEAK -Vertical EconoMi$er X with solid -state W7220 controller: ....................................... 50 lb TotalOperating Weight: ........................................................................................................................... 712 lb Unit UnitVoltage-Phase-Hertz: ............................................................................................................... 208-3-60 AirDischarge: .................................................................................................................................... Vertical FanDrive Type: ........................................................................................................ ............................... Belt ActualAirflow: ........................................................................................................................................ 2400 CFM SiteAltitude: ............................................................................................................................................. 200 ft Cooling Performance CondenserEntering Air DB :..................................................................................... ............................... 87.0 F EvaporatorEntering Air DB :.......................................................... ............................... ........................... 77.9 F EvaporatorEntering Air WB :........................................................ ............................... ........................... 64.5 F EnteringAir Enthalpy: ........................................................................................................................... 29.65 BTU /Ib EvaporatorLeaving Air DB :........................................................... ............................... ........................... 54.8 F EvaporatorLeaving Air WB :......................................................... ............................... ........................... 54.0 F Evaporator Leaving Air Enthalpy: .......................................................................................................... 22.63 BTU/Ib GrossCooling Capacity: ....................................................................................................................... 75.23 MBH GrossSensible Capacity: ...................................................................................................................... 59.61 MBH CompressorPower Input: ....................................................................................................................... 4.71 kW CoilBypass Factor: ............................................................................................................................... 0.095 FanRPM: ............................................................................................................................................... Mixed Air OutdoorAir Airflow: .................................................................................................................................. 420 CFM OutdoorAir DB :........................................................................................................ ............................... 87.0 F OutdoorAir WB :............................................................................ ............................... ........................... 67.0 F OutdoorAir Htg. Temp.: .......................................................................................................................... 18.0 F ReturnAir DB :............................................................................... ............................... ........................... 76.0 F ReturnAir WB :.............................................................................. ............................... ........................... 64.0 F ReturnAir Htg. Temp .:.................................................................. ............................... ...........................70.0 F Heating Performance HeatingAirflow: ...................................................................................................................................... 2400 CFM EnteringAir Temp: .................................................................................................................................. 60.9 F LeavingAir Temp: ................................................................................................................................... 83.8 F GasHeating Input Capacity: ................................................................................................................... 72.0 MBH Gas Heating Output Capacity: ................................................................................................................ 59.0 MBH TemperatureRise: .................................................................................................................................. 22.9 F Supply Fan ExternalStatic Pressure: ......................................................................................................................... 0.70 in wg Options / Accessories Static Pressure Economizer: ...................................................................................................................................... 0.17 in wg Total Application Static (ESP + Unit Opts/ Acc.) :...................................................... ............................... 0.87 in wg FanRPM: ............................................................................................................................................... 1492 Packaged Rooftop Builder 1.39y Page 8 of 13 Performance Summary For 6.0 Tons Project: -Untitled12 02/12/201( Prepared By: 12:19PN FanPower: .............................................................................................................................................. 2.07 BHP NOTE: ............................................................................................ Selected IFM RPM Range: 1173 - 1518 Electrical Data 90.2 VoltageRange: ............................................................................................................................... 187- 253 Compressor#1 RLA :..................................................................................................... .............................19 Compressor#1 LRA :..................................................................... ............................... ............................123 IndoorFan Motor Type: .......................................................................................................................... MED IndoorFan Motor FLA :............................................................................................... ............................... 8.4 CombustionFan Motor FLA (ea): ............................................................................................................ 048 PowerSupply MCA: ................................................................................................................................... 34 PowerSupply MOCP (Fuse or HACR) :....................................................................... ............................... 50 DisconnectSize FLA :.................................................................................................. ............................... 33 DisconnectSize LRA :................................................................... ............................... ............................199 Electrical Convenience Outlet: .............................................................................................................. None Outdoor Fan [Qty / FLA (ea)]: .............................................................................................................. 1 / 1.5 Electrical Data (Units produced on or after 02/09/2015 ) 66.3 Compressor#1 RLA :..................................................................... ............................... ...........................19.6 Compressor#1 LRA :..................................................................... ............................... ............................136 PowerSupply MCA: ................................................................................................................................... 35 PowerSupply MOCP (Fuse or HACR) :....................................................................... ............................... 50 DisconnectSize FLA :.................................................................................................. ............................... 34 DisconnectSize LRA :............................................................................................... ............................... 212 Electrical Data (Unit produced on or after May 18, 2015) PowerSupply MCA: ................................................................................................................................... 35 PowerSupply MOCP (Fuse or HACR) :....................................................................... ............................... 50 DisconnectSize FLA :.................................................................................................. ............................... 34 DisconnectSize LRA :............................................................................................... ............................... 212 May 18th and beyond units can be identified by serial number 2115XXXXXXXXX and higher Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E -12 Watts Advanced Acoustics Page 9 of 13 Discharge Inlet Outdoor 63 Hz 90.2 88.8 88.8 125 Hz 85.9 82.9 81.8 250 Hz 80.5 71.2 76.9 500 Hz 76.0 67.2 74.4 1000 Hz 72.3 66.4 73.3 2000 Hz 66.8 61.0 69.8 4000 Hz 68.6 57.0 66.3 8000 Hz 64.8 50.5 62.7 A- Weighted 79.1 72.5 78.0 Advanced Acoustics Page 9 of 13 Performance Summary For 6.0 Tons Project: - Untitled12 02/12/201E Prepared By: 12:19PIy Advanced Accoustics Parameters 63 1. Unit height above ground: .................................. 30.0 ft 2. Horizontal distance from unit to receiver: ........... 50.0 ft 3. Receiver height above ground: ............................ 5.7 ft 4. Height of obstruction: ........................................... 0.0 ft 5. Horizontal distance from obstruction to receiver: .0.0 ft 6. Horizontal distance from unit to obstruction: ........ 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 88.8 81.8 76.9 74.4 73.3 69.8 66.3 62.7 90.1 Lw B 62.6 65.7 68.3 71.2 73.3 71.0 67.3 61.6 78.2 LwA C 56.4 49.4 44.5 42.0 40.9 37.4 33.9 30.3 57.7 L D 30.2 33.3 35.9 38.8 40.9 38.6 34.9 29.2 45.8 L A Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A- Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A- Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.39y Page 10 of 13 Performance Summary For 6.0 Tons Project: —Untitled12 02/12/201E Prepared By 12:19Pfy 3 c a� 5D m U Fan Curve Airflow (CFM - thousands) RPM = 1492 BHP = 2.07 Maximum RPM = 2100 Maximum BHP = 3.70 Note: Please contact application engineering for selections outside the shaded region. SC - System Curve RP - Rated Point Packaged Rooftop Builder 1.39y Page 11 of 13 Unit Feature Sheet for 6.0 Tons Project: —Untitled 12 02/12/201E Prepared By: 12:19PN/ r"Al %W AleatberMaiker' — 48TC PACKAGED ROOFTOP GAS HEATINGIELECTRIC COOLING UNITS 3,4,51.6,75, RZ, 10. 125, 15 TONS O;donal Louvered Hail Guard Shovm WEATHERMAKER SERIES WeatherMaker (48TC) units are one-pieceg&s heating, electric cooling units that are pre-wired and charged with Puron (R-410) refrigerant. They are factory tested in both heating and cooling modes, and rated in accordance with AHRI Standards 210'24D (04-06 sizes) and 3401360 (07-16 sizes). WeatherMaker units are designed in accordance with UL Standard 1995, and listed by the Underwriters' Laboratories. Approved and certified by: C us & — -_ --- 1r au b Certified to ISO 9001 STANDARD FEATURES INCLUDE: • Purcin {R -410A) +4rC reftigers r t • ASHRAESO-1 energycompliant • Scroll compressors with iriternefilne breakand overload proteecimn • Single -stage coaling capsorlycoriballon 04-12niodels • 7wo-stage�ofngc oactycantmionOB-1,5 models • SEERs upto 13.0, EER's up to 111 and 1EERs up to 11.8 • A�nt,,W- system • Exclus I `vI nun-oorroshm composite ociridensate pan in accordance with ASHRAE Standard 62, sloping design, side orcentudiain • Standard cooling uperstion up to 1151F(46'r_)and dovvri to 4WF (4'C;) - down to 25* F (4' C) with winter startkit. • Pie-owitted exieriorpane69rid pnirrier-coated intemrpanetstested to 500 hours sat'spray protection • Ful�y insulated cabinet • Exclusive ](3C sm d-state ountralforon-bosid diagnostioswifli LED error code designation burnercontrullogio and enerpysaving indoor tan rnotar delay • LowNOx modes; thatnteet CaRfornia Air Quality Managernent • induced draritgas neatcorribustion design • Redundant gas valves with up to two stagesofhestmg • :Law pressure and high pressare ",itmh protected. MAINTENANCE FEATURES: • Access panel with easy grad handles • Innuvalve easy starring, no­stripsorews on unit access panels- Direct Drive ECM an 3 Tatum 5 tan (-5 voltage only,) rniodets; and beftdrve simplified control box anangernent • Extoluswe LED error code designation, b urnercontroliogicand energy saving indoor fan rnolordelsy. INSTALLATION FEATURES: • 7hm-tne-bar-ompowe,entryca;,abilty • Single pointgasarid elaatrio connections • FuR perirrwterbaseralt with bu4knrigq:ingadsptersandfcrksiot5 • FeWcanverublefrumverticaltio hDraCTIbl: airliDWfITT"tirrounting. (15 size rnodets require field iinstailled supply duct cove'). STANDARD WARRANTY: • 10-yearheSt exchanger- I option • 5J.8100-ripTeSSnT parts an Novabon CondenseTcclIS—Where avaiiab6e • tisnyootionslupgmdesaiscavadobie OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • PrerniiiirLink- and R7-J Open Muft,­Protpcu1DDC Control. • Supply and Return.kii­Srnoke Detectors, high staliornowis • Lauvenedcondenserocilgaards • Economizer, daconnectand convenience nutlet opims • Stainless Steel heat exonangeroption • Carrosw resltant ii coating, Hurnld4AZer2 adavbve deriumldftation system aysilaoiee on BE modelswth RIFF condenseicivils- Wtof Blaster) contro4emduded • Hinged socess panels "S,310z0p am M11KZ71% 12p, za;za "w rxirm im Packaged Rooftop Builder 1.39y Page 12 of 13 Spec Sheet for 6.0 Tons Project: - Untitled12 02/12/201 Prepared By: 12:19P Packaged Rooftop Builder 1.39y Page 13 of 13 Specification Data Panasonic Panasonic Ventilation Fan 7y/�isper�i�e YENT /LAT /ON fAN Description Ventilating fan shall be Low Noise remote mount type rated for continuous nun. Fan shall be Energy Star rated and certified by the Home Ventilating Institute 1�1/- SONLFi (340 c im/ (HVI). Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor /Blower: • Four -pole totally enclosed condenser motor rated for continuous run. • Power Rating shall be 120 volts and 60 hz. • Fan shall be UL listed for tub /shower enclosure when used with a GFCI branch circuit wiring. • Motor equipped with thennal -cutoff fuse. Housing: • Galvanized steel body for long -life. • Insulated housing to prevent condensation and noise. • Tapered duct adapter for easy connection. Easy Installation: • 5 positions installation. • Joist, truss and suspension brackets included. Warranty: • The factory warranty shall be a minimum of 3 years limited warranty on parts. Typical Specifications Ventilating fan shall be remote mount, Energy Star rated, with no less than 340 CFM as certified by the Home Ventilating Institute (I-M at 0.2" static pressure in inches crater gauge and no more than 1.7 sone as rated by manufacturer at 0.2" static pressure. Power consumption shall be no greater than 100 watts, Energy Star rated and Energy Efficiency rating shall be no less than 3.5 cfm /watt. The motor shall be totally enclosed, four pole condenser type engineered to run continuously. Power rating shall be 120v /60Hz. Housing shall be insulated to reduce condensation. Duct diameter shall be no less than 6 ". Fan shall be UL and cUL listed for tub /shower enclosure when used with GFCI branch circuit wiring. Brackets shall be provided for joist, truss or suspension installations. 1.2 Lu 1.1 a 1.0 3 0.9 W 0.8 H oa W 0.6 V 0.5 Z 0.4 �j 0.3 H 0.2 0.1 0.0 Fan Curve FV- 30NLF1 50 100 150 200 250 300 350 400 AIR FLOW (CFM) Specifications: Fan Model RPM Rated Volts I Max Watt* Max I Amps CFM` Max SP- Duct Di.. Weight Ibs Sones CFMMIatt "SP .2 "SP .4 "SP .6 "SP .8 "SP 1.0 "SP 1.2 "SP FV- 30NLF1 1247 120 98.2 .086 392 340 302 258 106 53 1.13 6" 24 1.7 3.5 Note: Sones were measured at factory test facility in a sound -proof room at suction side from a distance of 1.5 meters. For Complete Installation Instructions Visit www.panasonic.com/building c crE U� D Model Quantity Comments Project. Location: Architect: Engineer. Contractor: Submitted by. Date: Panasonic Building Dept. I Three Panasonic Way 4A -1 I Secaucus, NJ 07094 1 866- 292 -7292 1 www.panasonic.com /building Commercial Submittal Sheet NOfAMralk SD34 Series M A N u F A C T u R I N G Spiral Pipe Diffuser Double Deflection B 1 1/4 SD34 A * NOMINAL +1 7/8 B SD34 ye Model: SD34 Description: Spiral Pipe Diffuser Double Deflection Standard Features: • Transition box style spiral mount double deflection diffuser • Extruded aluminum diffuser frame with signature line marks • Front blades run parallel to shortest dimension • Back blades run parallel to longest dimension • Nylon bushings for easy adjustment of blades and allows for 4 -Way airflow • Curved saddle fits spiral radius • Neoprene open cell gasket for airtight fit • Soft White INAL Options: '/8 ❑ Galvanized (SD34 -GALV) ❑ Linear bar face diffuser (SD -LSW) ❑ Perforated face diffuser (SD -P) ❑ Recessed screwdriver operated Opposed Blade Damper (SD34 -0, SD34 - GALV -0, SD- LSW -O) ❑ Half- length screwdriver Operated Scoop Extractor (SD34 -SC, SD34 - GALV -SC, SD- LSW -SC) ❑ Full- length screwdriver Operated Scoop Extractor (SD34 -FS, SD34 - GALV -FS, SD- LSW -FS) Finishes: Diffuser Standard Colors Designer Colors ❑ Soft White ❑ Almond ❑ Camaro Silver ❑ Navajo White 8" ❑ Black Velvet ❑ Coffee Tan ❑ Vanilla 12" ❑ Bronze Product Notes: 18" Spiral pipe diameter must be 4" larger than the width of the register. SD34 Series Dimension Chart Diffuser Pipe Diameter Width Dimension• 8" 10" 12" 14" 16" 18" 20" 22" 24" 26" 28" 30" 32" 1 34" 1 36" 38" 40" 42" 44" 46" 48" A 5 47/8 47/8 43/4 43/4 145/8 41/2 41/2 141/2 41/2 4% 41/2 41/2 41/2 41/2 41/2 43/8 43/8 43/8 43/8 43/8 4 B 71/873/8 7 1/2 75/8 73/4 77/8 77/8 77/8 77/8 77/8 77/8 77/8 77/8 77/8 77/8 77/8 8 8 8 8 8 A n/a 5 5 47/8 43/4 43/4 45/8 45/8 41/2 41/2 4112 41/2 41/2 41/2 41/2 41/2 41/2 43/8 43/8 43/8 43/8 6 B n/a 9 91/4 91/2 95/8 93/4 97/8 97/8 97/8 97/8 97/8 97/8 97/8 97/8 97/8 97/8 97/8 10 10 10 10 A n/a n/a 51/8 5 47/8 43/4 43/4 45/8 45/8 45/8 .41/2 41/2 41/2 .41/2 .41/2 41/2 41/2 41/2 43/8 43/8 43/8 8 B n/a n/a 10 7/8 11 1/4 113/8 11 5/8 11 3/4 11 7/8 11 7/8 11 7/8 11 7/8 11 7/8 11 7/8 11 7/8111 7/8 11 7/8 11 7/8.11 7/8 12 12 12 A n/a n/a n/a 5 5 47/8 47/8 4314 43/4 45/8 45/8 45/8 41/2 41/2 41/2 41/2 41/2 4 1/2 41/2 43/8 43/8 10 B n/a n/a n/a 13 131/4 133/8 131/2 135/8 135/8 137/8 137/8 137/8 137/8 137/8 137/8 137/8 137/8 137/8 137/8 14 14 A n/a n/a n/a n/a 51/8 5 147/8 47/8 47/8 43/4 45/8 45/8 45/8 45/8 41/2 41/2 41/2141/2 4 1/2 41/2 41/2 12 B n/a n/a n/a n/a 147/8 15 1/8 15 3/8 151/2 151/2 155/8 15 7/8115 /8115 7/8 157/8 157/8 157/8 15 7/8115 7/8 157/8 15 7/8 15 7/8 'A/B dimensions defined in product drawings are dependent on size of spiral pipe product is designed for. Additional Information: Project / Location: Submittal Notes Engineer: Architect: Contractor: Last Revised: 3/18/2015 T N N 6 L6 m A A �j A Q oD m o m co N C14 N N N N 04 N M M m Q, O m V w cq ol LO LO M to 2 O M v m c*,) Cq N N N IN M M m m m cl) m It Lo 11 Lo ol M m m m M N �-o cy N N N N N N N N m Lo 0 N 0 'q C? W It N N N N N N N. C-4 Lq w ID r- '0 m w Oo m m 'o o 'o o OM N � q o (D �2 N '�R F4 N N N NO �2 R" 'A 04 mm N N cL4 IQ a) w lo 04 o c, m N o N M 1 N LO V v v v v v N v v N v m v m v m v of co 12 � � O c, pp " , , m o o o . V N 04 N Ql N C14 M CN t N m N co V v v v v N V N V N V N v m v m v- v in un Lq ol cl co o Lr) o w 0 c v v v v v N v v m u, 11) m D N o CN Cv4 v v w v Nv Nv w N v L) c G z o O. C) C) 2 u z 2 u cl ol C14 N M = ID (o O r oo M ELD - - - —M...... 0 x X x x O A ............. . ........... General Mechanical Notes All thermostats used for both heating and cooling shall provide a range or deadband of at least 5 °F. WSEC Section C403.2.4.2 All thermostats are to be seven day programmable, micro - processor based. Sunset Inc. Project: Mariuchi Restaurant All heating and cooling systems shall have automatic start controls for each HVAC system WSEC Section C403.2.4.3.3 All ductwork shall be constructed and sealed per SMACNA standards. All ductwork shall be braced per IMC 2012. Duct support per Section 603.10. All refrigerant used shall be Puron (R- 410a). All flues shall be located a minimum of 10' from outdoor air intakes. All exhaust terminations shall be a minimum of 10' horizontally from, or 3' above outdoor intakes. All air - economizers shall have modulating outdoor air and return air dampers capable of providing 100% outdoor air for cooling. WSEC Section C403.3.1.1.1 All air - economizers shall be fully modulating and capable of partial cooling (integrated operation). WSEC Section C403.4.1.3. All addressable functions of duct smoke detectors, and wiring for shutdown, shall be by others. All roof mounted units shall be secured to their respective roof curbs. All exposed edges of internal duct liner shall be sealed with a mastic coating. All completion requirements must comply with WSEC Section C408.2 To comply with WSEC Section C408.1.3.2 systems documentation, record documents and training will be completed and coordinated with owner. To comply with WSEC Section C408.1.2 preliminary commissioning report will be submitted to owner after being certified by registered design professional or approved agency. All thermostats to be mounted such that the top of the device is 48" above finished floor. All gas piping shall be sized per 2012 IFGC. All HVAC systems shall be air balanced and adjusted to deliver final flow rates within 10% of design rates. Outdoor air supply and exhaust ducts shall shut automatically when the system or spaces served are not in use or during building warm -up, cooldown, and setback. WSEC Section C403.2.4.4 Outdoor air supply and exhaust ducts shall be equipped with motorized dampers according to WSEC Section C403.2.4.4 Equipment shall meet the minimum efficiency requirements of WSEC Section C403.2.3 System sizing to comply with WSEC Section C403.2.2 Damper leakage rates shall comply with WSEC Section C402.4.5.2 Duct Insulation Schedule: All ductwork shall be insulated as follows: DUCT TYPE: LOCATION INSULATION R -TYPE TYPE Supply /Return Not within insulated envelope (exterior of building, on roof, in attic -above insulation, in crawl spaces) R -7 2" wrap or liner Supply /Return /OA Not within insulated envelope (in ground) R -5.3 1.5" liner or 1" Spunstrand OA Intake Not within insulated envelope R -0 - OA Intake (Rectangular) Within insulated envelope, in mechanical room. R -7 2" liner OA Intake (Round) Within insulated envelope R -7 2" wrap Supply on cooling systems Within insulated envelope, not exposed to space served. R -3.3 1" wrap or liner Supply on cooling systems Within insulated envelope, exposed to space served. R -0 - Supply on heating only systems Within insulated envelope R -0 - Return Within insulated envelope R -0 - Exhaust Other than R occupancy R -0 - Exhaust R occupancy (Residential) R -8 2" wrap or liner Per section 403.2 of the 2012 IMC (Washington State Amendments), we are using ASHRAE Standard 62.1 2010 as an alternate means of compliance with the 2012 IMC Section 403.2 Washington State Amendments. Description Space Occupancy People OSA Rate OSA /SQFT Vent Reqired REFGRNT (LBS) (SQFT /Rooms) (From ASHRAE Std 621) CFM /Person (Per 1000 SOFT) OSACFM RTU -1 Food" RTU -1 CARRIER 48TCDA07A1A5 2,400 0.75 Beverage 1 57,600 YES CIRCUIT #1 14 -2 11.0 Service 1,465 Restaurant & dining rooms 7.5 0.18 986 Total 1,465 48TCDA07A1A5 2,400 0.75 986 ASHRAE Standard 62.1 -2010 VIAQ Per section 403.2 of the 2012 IMC (Washington State Amendments), we are using ASHRAE Standard 62.1 2010 as an alternate means of compliance with the 2012 IMC Section 403.2 Washington State Amendments. Description Space Occupancy People OSA Rate 1(Per1000SQFT)1 OSA /SQFT Vent Regired REFGRNT (LBS) (SQFT /Rooms) (From ASHRAE Std 62.1) CFM /Person Voltage (Volt - Phase) OSA CFM RTU -2 00 RTU -1 CARRIER 48TCDA07A1A5 2,400 0.75 Beverage 1 57,600 YES CIRCUIT #1 14 -2 11.0 Service 1,465 Restaurant & dining rooms 7.5 0.18 986 Total 1,465 48TCDA07A1A5 2,400 0.75 986 GAS PACKAGED UNIT SCHEDULE Sunset Inc. Project: Mariuchi Restaurant MARK MAKE MODEL CFM ESP (IN H20) (AFUE) COOLING CAP Total (BTU /H) Sens. ECONO (YES /NO) REFGRNT (LBS) EER MCA (Amps) MOCP (Amps) Voltage (Volt - Phase) Weight (lbs.) CO2 Y/N Comments RTU -1 CARRIER 48TCDA07A1A5 2,400 0.75 82.0% 72,000 57,600 YES CIRCUIT #1 14 -2 11.0 310 50 208/230 -3 875 Y 14" CURB, DN SHOT ECONO, SEE NOTE 1 RTU -2 CARRIER 48TCDA07A1A5 2,400 0.75 82.0% 72,000 57,600 YES CIRCUIT #1 14 -2 11.0 33.0 50 208/230 -3 875 Y 14" CURB, DN SHOT ECONO, SEE NOTE 1 1. Per IMC 606.2 Exception, no duct smoke detectors are required in this installation. Per IMC section 606, Air moving systems supplying in excess of 2000 CFM shall be equipped with a duct mounted duct detector smoke detector. Where duct mounted smoke detectors are required by the IMC, we propose to furnish non - addressable type units. If addressable units are required for interface with other building systems, these units will either be supplied by others, or the units provided by Sunset will be modified as required by others to allow such interface FAN SCHEDULE MARK MAKE MODEL STYLE FLOW (Constant I VFD) FLA (Amps) WATTS Voltage (Volt - Phase) WT EF -1 PANASONIC FV- 30NLF1 INLINE CONSTANT 0.9 94.9 115 -1 18 GRILLE SCHEDULE MARK MAKE MODEL Comments A SHOEMAKER 700 MA LAY IN SUPPLY B SHOEMAKER MA HARD LID SUPPY C SHOEMAKER 645T LAY IN RA/EXH D SHOEMAKER 645 HARD LID RA/EX