Loading...
20160223 Permit Pkg 06132016City of Yelm Community Development Department Building Division Phone: (360) 458 -8407 Fax: (360) 458 -3144 Applicant: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Property Information: Site Address: 15358 92ND AVE SE Assessor Parcel No.: 41610009100 Contractor Information: Name: SOUNDBUILT NW LLC Address: PO BOX 73790 PUYALLUP WA 98373 Contractor License No.: Project Information: Project: NEW RESIDENTIAL BUILDING Description of Work: LOT 91, PLAN 2603A Sq. Ft. per floor: F' t 1262 i rs Second 1341 Third Garage 414 Basement Fees: Item NEW RESIDENTIAL BUILDING MECHANICAL PLUMBING Subdivision: Permit No.: 20160223 Issue Date: 6/13/2016 (Work must be completed within 180 days) Phone: 253 - 848 -0820 Owner: SOUNDBUILT NW LLC CHERRY MEADOWS Lot: 91 Expires Phone: 0 /00 /0000 Heat Type (Electric, Gas, Other) GAS Contractor Fees SOUNDBUILT NW LLC $17,524.93 SOUND HEATING & AC $ 78.25 RAINIER VIEW ROOTER $ 118.00 TOTAL FEES: $ 17,721.18 Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applying as a contractor, I further certify that I am currently registered in the State of Washington. Signature Date Firm ')CAA F1 /w , 1 Yoh 0 OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: Cite of Yelm (36 t) 458 -3244 REC #: 00234271 6/13/2016 4:20 PM OPER: CO TERM: 001 REF #: 7555 PAID BY. TRAM: 33.0000 BUILDING PERMITS 20160223 17,721.1E;CR SOUNDBUILT NW LLC 15358 92ND AVE SE BLD -RES1 17,524.9:iCR MECH 78.2E)CR PL 118.000R TRAM: 33.0000 BUILDING PERMITS 20160238 18,313.1`.)CR SOUNDBUILT NW LLC 9903 JENSEN DR SE BLD -REST 18,084.75CR MECH PL 139.000R TRAN: 33.0000 BUILDING PERMITS 20160240 17,910.%CR SOUNDBUILT NW LLC 9975 JUSTMAN ST SE BLD -RES1 17,707.7('CR MECH 78.25CR PL 125.000R IRAN: 33.0000 BUILDING PERMITS 20160239 18,249.5:0 SOUNDBUILT NW LLC 9981 JUSTMAN ST SE BLD -RES1 18,025.78CR MECH 84.75CR PL 139.000R TENDERED: 72,194.81 CHECK APPLIED: 72,194.81 - CHANGE: YELM COMMUNITY SCHOOLS PO BOX 476 YELM WA 98597 Receipt #: 356465 Clerk: Croy Manual #: Terminal: 1 6/13/2016 4 :11 PM NSOUNDBUILT NSOUNDBUILT SOUND BUILT NW LLC, HOMES PO BOX 73790 PUYALLUP, WA 98373-0790 Qty Item Price 3015.00 1 CPF MITIGATION MITIGATION 03- 021 /LOT 91/15358 92ND AVE SE;YELM 1 CPF MITIGATION 3015.00 MITIGATION 05- 027/LOT 141/9981 JUSTMAN ST SE;YELM 1 CPF MITIGATION 3015.00 MITIGATION 05- 027 /LOT 140/9975 JUSTMAN ST SE;YELM 1 CPF MITIGATION 3015.00 MITIGATION 05 -027 /LOT 20/9903 JENSEN DR SE; YELM Subtotal 12060.00 Tax 0.00 Total 12060.00 Check 12060.00 7549 Change Due 0.00 THANK YOU Zo« oaX� CITY OF YELM RESIDENTIAL BUILDING PERMIT APPLICATION FORM Project Address: 15358 92nd Ave SE Parcel #: 41610009100 Subdivision: Cherry Meadows Lot #: 91 Plan #: 2603A Zoning: IZI New Construction ❑ Re -Model / Re -Roof / Addition Home Occupation Sign El Plumbing 0 Mechanical Mobile / Manufactured Home Placement Other Project Description /Scope of Work: construct new SER using base plan 2603A Project Va Building Area (sq. ft) 1St Floor 1262 2nd Floor 1341 3rd Floor Garage -2 car 414 3 car. Covered Patio 50 Covered Porch 168 Patio Deck # Bedrooms 4 # Bathrooms 2.5 Heating: GAS /OTHER r ELECTRIC (Circle One) Are there any environmentally sensitive areas located on the parcel? If yes, a completed environmental checklist must accompany permit application. BUILDING OWNER NAME: Soundbuilt Homes ADDRESS Po Box 73790 EMAIL meganp @soundbuilthomes.com CITY Puyallup STATE WA ZIP 98373 TELEPHONE 253 - 848 -0820 ARCHITECT /ENGINEER Landmark Design /Sega Engineering LICENSE # END - 26606 (Greg Thesencitz) ADDRESS 1202 Main St EMAIL kevin @landmarkdesign.com CITY Sumner STATE WA ZIP 98390 TELEPHONE 253 -826 -7808 GENERAL CONTRACTOR Soundbuilt Homes TELEPHONE 253-848-0820 ADDRESS PC Box 73790 EMAIL meganp @soundbuilthomes.com CITY Puyallup STATE WA ZIP 98373 FAX n/a CONTRACTOR'S LICENSE # SouNDNL911CL EXP DATE 2/17 CITY LICENSE # PLUMBING CONTRACTOR Rainier view Rooter LLC TELEPHONE 253-435-1996 ADDRESS P0 Box 73070 EMAIL CITY Puyallup STATE WA ZIP 98373 FAX CONTRACTOR'S LICENSE # RAiNiVR942DF EXP DATE 3/18 CITY LICENSE # MECHANICAL CONTRACTOR Sound Heating s AC TELEPHONE 253 - 875 -3350 ADDRESS 5526184th St E #A EMAIL CITY Puyallup STATE WA ZIP 98375 FAX CONTRACTOR'S LICENSE # SouNDHC867DE EXP DATE 3/18 CITY LICENSE # Copy of mitigation agreement with Yelm Community Schools, if applicable. I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City of Yelm. /11-n a I I �/ Applicant's Signature Date Owner / Contractor / Okher's Agent / Contractor's Agent (Please circle one.) All permits are non - transferable and will expire if work authorized by such permit within 180 days of issuance, or if work is suspended or abandoned for a period of ' Iq q BY: ___ 105 Yelm Avenue West (360) 458 -3835 Yelm, WA 98597 (360) 458 -3144 FAX www.ci.yelm.wa.us SEGA Engineers Structural & Civil Consulting Engineers September 16, 2015 To: Building Official City of Yelm Community Development Department From: Greg Thesenvitz, PE /SE Principal Re: Site specific structural calculations. SEGA Engineers has provided structural calculations for plan Plan 2603 prepared for Soundbuilt Homes. The calculations are for a generic site with a design criteria of a 25 psf snow load, a 110 mph Exposure B wind load, and Seismic Zone D per 2012 International Building Code Chapter 16. This is to verify that the calculations and design criteria above are applicable for the following project and location: Soundbuilt Homes Cherry Meadows, Lots 25 -133 Yelm, Washington. Please address any questions to SEGA Engineers 2011 BY:-------------- ------ 22939 SE 292 °d Place • Black Diamond, Washington 98010 - (360) 886 -1017 SEGA Engineers Structural & Civil Consulting Engineers September 16, 2015 To: Building Official City of Yelm Community Development Department From: Greg Thesenvitz, PE /SE Principal Re: Site specific structural calculations. SEGA Engineers has provided structural calculations for plan Plan 2603 prepared for Soundbuilt Homes. The calculations are for a generic site with a design criteria of a 25 psf snow load, a 110 mph Exposure B wind load, and Seismic Zone D per 2012 International Building Code Chapter 16. This is to verify that the calculations and design criteria above are applicable for the following project and location: Soundbuilt Homes Cherry Meadows, Lots 25 -133 Yelm, Washington. Please address any questions to SEGA Engineers EC Oil IV BY: -------------- - - - - -- 22939 SE 292 ❑d Place • Black Diamond, Washington 98010 • (360) 886 -1017 2' MIN SETBACKS BETWEEN SIDEWALKS, DRIVEWAYS AND EASEMENTS FROM STEP TANK. WITH 5' MIN FROM PROPERTY LINES, HOUSE AND PORCH FOUNDATION AND 12' MIN FROM PROPERTY LINE ... CHERRY MEADOWS LOT - 1 I . . _ Alm 7 CD Approved /gin _57 • SOUNDBUILT HOMES, INC. P.0 Box 73790 ?UYALWP WA 98373 PH (253) 848 -0920 FAX (253) 53MS14 THURSTON COUNTY -^ 15358 92nd Ave SE, Yefm, WA. 98597 PARCEL# 41610009100 a LOT 91 WG 0511512016 IMPERVIOUS AREA II?�I ROOF=l 510EWALK -4A0 S.F. TOTAL* 2.39D S.F. LOT SCALE: V =10' 0 5 10 20 1 ZI 1-1Q z NOTES t I ECEIVE� BY-- ____.___e_____...... 1. ALL EXPOSED SOILS WILL BE MULCHED WHEN NOT BEING WORKED 2. SILT FENCE TO BE INSTALLED AS APPROVED BY PIERCE COUNTY INSPECTOR. CONTACTINFO MEGAN: (253) 25&8748 City of Yelm Community Development Department Residential Certificate of Occupancy Building Address 15358 92ND AVE SE Owner Name SOUNDBUILT NW LLC Owner Address PO BOX 73790 PUYALLUP WA 98373 Building Permit Number 20160223 Plan Number Remarks: LOT 91, PLAN 2603A Areas Inspected Special Conditions Building Official: Date: January 3, 2017 This structure is in compliance with the International Residential Code (Chapter 51 -51 WAC) as adopted by the Washington State Building Code Council pursuant to Chapters 19.27 and 70.92 RCW, effective July 1, 2013 t� & pir WndHJGningI _ Property Address: l ? / -Zi Date: Conditioned Floor Area: Builder or registered design professional: Signature: R- Values R- Floors Over unconditioned space R-_ I Ceiling: Vaulted Slab on grade floor R---- Attic R R -_ Walls: Above Grade R- ______ Doors R -_ Below, int. R- R -_ Below, ext R U- Factors and SHGC W indows U -____— SHGC-__ - NFRC rating (or) naae to wsec zoo91 skylights U -_ SHGC-_ Default Rating ( Toble 406.2 Option(s) Total 406.2 Credits — Heating, Cooling & Domestic Hot Water Efficiency Type System Heating J Cooling ,� o A—. DHW Duct & Building Air Leakage /I " Insulation R -- HVAC in conditioned space (yes i "° Ail ducts & qir H ' � f/ andler present O. Test Method: �otal Leakage (/Leakage to exterior CFM @25Pa %(} CFM @25Pa Test Result Test Target Building air leakage target: ACHso <5.0 - Tested leakage: ACHso= Onsite Renewable Energy Electric power System . Rated annual generation � —K�"h System Type'. Q Z- 2-3 Duct Leakage Affidavit (New Construction) Permit #: House address or lot number ( �� G2 kje -,( GA �t City: �'C.� 1 zip: �> Cond. Floor Area (fe): Source (circle one): Plans Estimated Measured ❑ Duct tightness testing is not required. The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope. Ducts located in crawl spaces do not qualify for this exception. Air Handler in conditioned space? ❑ yes Xno Air Handler prese unng test ?Ryes ❑ no Circle Test Method: Leakage to Outside Total Leakage Maximum duct leakage: Post Construction, total duct leakage: (floor area x .04) = CFM @25 Pa Post Construction, leakage to outdoors: (floor area x .04) = CFM @25 Pa Rough -In, total duct leakage with air handler installed: (floor area x.04) = 16LI CFM @25 Pa Rough -In, total duct leakage with air handler not installed: (floor area x .03) = CFM @25 Pa Test Result: 11 Q CFM @25Pa Ring (circle one if applicable): Open 1 2 3 Duct Tester Location: ?Z IA Pressure Tap Location: /A I cert ify that these duct leakage rates are accurate and determined using standard duct testing protocol. Company Name: '�c�c� Technician: Technician Signature: / 0 Date: Phone Number: Z��- 87s 3 Lj 2al��zZ3