Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
20160114 Product Data 04202016
Yelm School District 9 -Unit 1315 Yelm Ave W, Yelm WA 98597 FIRE SPRINKLER PRODUCT SUBMITTAL DATA Emerald Fire 11021 Cramer Road KPN Gig Harbor, WA 98329 Phone: 253 - 857 -2056 — Fax: 253 - 857 -2312 Yelm School District 9 -Unit 1315 Yelm Ave W, Yelm WA 98597 FIRE SPRINKLER PRODUCT SUBMITTAL DATA 1. Tyco TY313 QR 1 /2" 155* & 200* K =5.6 Brass Upright Sprinkler 2. Tyco TY323 QR 1/2" 155* K =5.6 Chrome Recessed Pendent Sprinkler 3. Globe QR GL5635 1" 155* K =5.6 Chrome Dry Pendent Sprinkler 4. Sprinkflex Flexible Sprinkler Hose Fittings 5. Allied Tube & Conduit Schedule 10 Black Pipe (1 1/2 ", 2 ", 2 1/2 ", 4 ") 6. Allied Tube & Conduit Schedule 40 Black Pipe (1 ") 7. Anvil International Black Cast Iron Threaded Fittings (1 ") 8. Tolco #4L Longitudinal Sway Brace Attachment 9. Tolco 9100 All Thread Rod (3/8 ") 10. Tolco #200 "Trimline" Adjustable Band Ring Hanger (1 ", 1 1/2 ", 2 ", 2 1/2 ", 4 ") 11. Tolco #906 Sway Brace Multi - Fastener Adapter 12. Tolco #909 No- Thread Swivel Sway Brace Attachment 13. Sammy Wood Screws Model GST 20 & GST 30 14. Sammy Screws Wood Sidewinders Model SWG 20 15. Victaulic Model 07.01 Grooved Fittings (1 1/2 ", 2 ", 2 1/2 ", 4 ") 16. Victaulic Style 009N Grooved Rigid Couplings (1 1/2 ", 2 ", 2 1/2 ", 4 ") 17. Victaulic Style 75 Grooved Flex Coupling (2 1/2" & 4 ") 18. Reliable REL -BFG -300 Grooved Butterfly Valve (2 1/2 ", 4 ") 19. Tyco DPV -1 Dry Pipe Valve (4 ") 20. Tyco Model 513 Riser Manifold (2 1/2 ") 21. Gast Oilless Air Compressor (Riser Mount) 1 /4HP 22. Potter Model PSI OA Pressure Switch 23. Potter Model PS40A High /Low Pressure Switch 24. Argco Spare Head Cabinet 25. Wilkins 350AST Double Check Backflow Prevention Assembly (4 ") tqco Fire Protection Products Worldwide I www tyco- fire.com Contacts Series TY -FRB, 5.6 K- factor Upright, , R Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY -FRB, 5.6 K- factor, Upright (TY313) and Pendent (TY-328) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb -type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: • A two -piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. • A two -piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY -FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING' that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY -FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner/ s responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 ....... Upright 5.6K, 1 /2 -NPT TTY323 . . . . . . Dl..,.- 8Rt 5.614, 1,12- Pi RT Technical Data Approvals UL and C -UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C -UL Listed as Corrosion- Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)' The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K =5.6 GPM /psil/2 (80,6 LPM /barl/2) FEBRUARY 2014 Temperature Rating 1862F(672G) 155 °F (68 °C) G) 200 °F (93 °C) 2862F (141 2G) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ................... Bronze Button .............. Brass /Copper Sealing Assembly ......... Stainless Steel w /TEFLON Bulb ......................Glass Compression Screw........ Bronze Deflector ................. Bronze TFP172 TFP172 Page 2of4 Components: 1 Frame 2 Button 3 Sealing Assembly I i 4 - Bulb 5 - Compression Screw * Temperature rating is ** Pipe thread connections per ISO 7 -1 indicated on Deflector. can be provided on special request. ESCUTCHEON PLATE 6 - Deflector* DEFLECTOR* SEATING SURFACE 7/16" (11,1 mm) NOMINAL 2" MAKE -IN (50,8 mm) 2" �� �/ 1 3/8" (50,8 mm) (34,9 mm) / 112" NPT ** CROSS SECTION UPRIGHT 112" 7/16" (11,1y(m) NPT ** NOMINAL AKE -IN WRENCH FLATS i STYLE 15 or RECESSE ESCUTC CTOR * J�4__ 2 -7/8" (73,0 mm) DIA. or_NPrN RECESSED PENDENT FIGURE 1 SERIES TY -FRB UPRIGHT (TY313) SPRINKLERS 5.6 K- FACTOR, 112 INCH NPT, QUICK RESPONSE ^WRENCH RECESS (USE ONLY END "A") FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PU WRENCH I O ENSURE NGAGEM ENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W- TYPE 7 RECESSED SPRINKLER WRENCH Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY -FRB, 5.6 K- factor, Upright (TY313) and Pendent (TY-32-3) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY -FRB, 5.6 K- factor, Upright (TY313) and Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb -type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135 °F (57 °C) and 3/32 inch (2,4 mm) for the 286 °F (141 °C) temperature ratings. A leak -tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft. -Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over - tightening the sprinkler. Re- adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY -FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe- thread sealant applied to the pipe threads, hand - tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W -Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W -Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft. -Ibs. (9,5 to 19,0 Nm). Care and Maintenance The TYCO Series TY -FRB, 5.6 K- factor, Upright (TY313) and Pendent (TV323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. TFP172 Page 3of4 2 -7/8" DIA. (73,0 mm) 2 -1/4" DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8" (15,9 mm) FLUSH 3/8 ±5/16" (9,5 ±7,9 mm) �_I MOUNTING 1/8" SURFACE (3,2 mm) CLO E SERIES MOUNTING 1 -3/8" (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIE -FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 518 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2 -7/8" DIA. (73,0 mm) FACE OF SPRINKLER 2 -1/4" DIA. FITTING (57,2 mm) 5/16 ±1 /4" Z2, (7,9 ±6,4 mm) FLUSH MOUNTING 1/8" SURFACE (3,2 mm) CLO RE SERIES MOUNTING 1 -3/8" (34,9 mm) TY-FRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIF -FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and /or national codes. TFP172 Page 4of4 P/ N * 77 - XXX - X - XXX SPRINKLER FINISH SIN 1 NATURAL BRASS PURF WHITE (RAI=994 9)* 370 5.6K UPRIGHT (1 /2 -NPT) TY313 3 onl v4RTPR SIGNAL WHITE (RAI=9998) 374 T =P 4 onl vFcTFo Use suffix "I" for ISO 7 -1 connection; 9 GI IRG)ME PLATED for example, 77- 370 -4 -175 -1 " Eastern Hemisphere sales only TABLE A SERIES TY -FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco - fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P /N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY -FRB Upright er Pea - deet (specify) Sprinkler, SIN (specify), K =5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). * R .f... +.. T ..h RiGal [Data Sheet TPP77A Sprinkler Wrench Specify: W -Type 6 Sprinkler Wrench, P/N 56- 000 -6 -387 , WN 66 860 A 001 TEMPERATURE RATINGS 436 486-F (ms) 155 155 °F (68 °C) 47-6 G) 200 200 °F (93 °C) 246 2962F -(#41 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1- 215 - 362 -0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tyCO TEFLON is trademark of The DuPont Corporation. Fire Protection Products tqco Fire Protection Products Worldwide I www tyco- fire.com Contacts Series TY -FRB, 5.6 K- factor '11niminht Damao"* Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY -FRB, 5.6 K- factor, UpFight (TY-318) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb -type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: • A two -piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. • A two -piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY -FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING' that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY -FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner/ s responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY323 ...... Pendent 5.6K, 1 /2 -NPT Technical Data Approvals UL and C -UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C -UL Listed as Corrosion- Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)' The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K =5.6 GPM /psil/2 (80,6 LPM /barl/2) FEBRUARY 2014 Tl ,ml, t 4,- i Temperature Rating 1862F(672G) 1i5�o 5C°F (68 °C) TTSF (792O) G) 2862F (141 2G) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ................... Bronze Button .............. Brass /Copper Sealing Assembly ......... Stainless Steel w /TEFLON Bulb ......................Glass Compression Screw........ Bronze Deflector ................. Bronze TFP172 TFP172 Page 2of4 Components: 1 Frame 4 Bulb 2 Button 5 Compression 3 Sealing Screw Assembly 6 Deflector * Temperature rating is ** Pipe thread connections per ISO 7 -1 indicated on Deflector. can be provided on special request. DEFLECTOR* 6* G 5 7/16" (11,1 mm) 4 NOMINAL MAKE -IN 2 2" (50,8 mm) 1 CROSS SECTION 1/2" NPT ** ESCUTCHEON PLATE SEATING SURFACE I (50,� 1/2" 7/16" (11,1 mm) NPT ** NOMINAL MAKE -IN STYLE 15 or 20 RECESSED ESCUTCHEON RECESSED PENDENT FIGURE 1 SERIES TY -FRB UPRh9tff ffi9l AND PENDENT (TY323) SPRINKLERS 5.6 K- FACTOR, 112 INCH NPT, QUICK RESPONSE / WR H RECESS (USE ONLY END "A ") FIGURE 2 W- -TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W- TYPE 7 RECESSED SPRINKLER WRENCH Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY -FRB, 5.6 K- factor, UpFight (T and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY -FRB, 5.6 K- factor, UpFight (TY-313) ai9d Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb -type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135 °F (57 °C) and 3/32 inch (2,4 mm) for the 286 °F (141 °C) temperature ratings. A leak -tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft. -Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over - tightening the sprinkler. Re- adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY -FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe- thread sealant applied to the pipe threads, hand - tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W -Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W -Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft. -Ibs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY -FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe- thread sealant applied to the pipe threads, hand - tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W -Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W -Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft. -Ibs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY -FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY -FRB, 5.6 K- factor, UpFight (T-Y-313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. TFP172 Page 3of4 2 -7/8" DIA. (73,0 mm) 2 -1/4" DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8" (15,9 mm) FLUSH 3/8 ±5/16" (9,5 ±7,9 mm) MOUNTING 1/8" SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1 -3/8" (34,9 mm) TY -FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY -FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 518 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2 -7/8" DIA. (73,0 mm) FACE OF SPRINKLER 2 -1/4" DIA. FITTING (57,2 mm) 5/16 ±1 /4" 1/2" (12,7 mm) (7,9 ±6,4 mm) FLUSH MOUNTING 2 m SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1 -3/8" (34,9 mm) TY -FRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY -FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and /or national codes. TFP172 Page 4of4 P/ N * 77 - XXX - X - XXX SPRINKLER FINISH SIN 4- NAT RAL BRASS SS PURF WHITE 37-9 3 3 oni v (RAI= SIGNAL WHITE (RAI=9998) 371 5.6K PENDENT (1/2" "NPT) TY323 ¢ onivcTFR Use suffix "I" for ISO 7 -1 connection; 9 CHROME PLATED for example, 77- 370 -4 -175 -1 ** Eastern Hemisphere sales only TABLE A SERIES TY -FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco - fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P /N). Sprinkler Assemblies with NPT Thread Connections Specify: Series Pen- dent (specify) Sprinkler, SIN (specify), K =5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify *) finish, P/N (specify *) Specify: Style 20 Recessed Escutch- eon with (specify *) finish, P/N (specify *) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench WN 66 999 6 887 Specify: W -Type 7 Sprinkler Wrench, P/N 56- 850 -4 -001 TEMPERATURE RATINGS 436 486-F (ms) 155 155 °F (68 °C) #7-6 4;z6°F (;zg'f) 299 290°-F—(98oG) 286 2962F� GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1- 215 - 362 -0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tyCO TEFLON is trademark of The DuPont Corporation. Fire Protection Products ...� .... FIRE SPRINKLER CORPORATION DESCRIPTION AND OPERATION QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES The Globe Quick Response GL Series Dry Type Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. The Globe Quick Response GL Series Dry Type Pendent Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation ap- proximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's Model GL Series sprinkler proven actu- ating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Ratings - , 155 °F (68 0C), 4750F (7-90(;), 2990P (990(; 2960P (4 n 4494 • Water Working Pressure Rating - 175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) . Maximum low temperature glass bulb rating is -67 °F ( -55 °C) • Frame - bronze. Deflector - brass . Screw - brass • Bulb DRY TYPE 9oi- -A x- �J�L7W SLEEVE & SKIRT seat - brass *Spring - teflon coated nickel alloy. Retainer - brass • Pin - stainless steel *Torsion spring - stainless steel • Bulb - glass with alcohol based solution, 3mm . Orifice insert - brass • 3/4" NPT or 1" NPT • Outer tube - galvanized steel pipe • Inner tube stainless steel • SPRINKLER TEMPERATURE RATING /CLASSIFICATION and COLOR CODING 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 JULY 2010 A -55 989 - 846 -4583 • FAX 989 - 846 -9231 BULLETIN GL5635, REV. #13 AVAILABLE BULB N.F.P.A. MAXIMUM CLASSIFICATION SPRINKLER TEMPERATURES COLOR CEILING TEMPERATURE ORDINARY 436OF/155 °F a7OG /68 °C GRANGE/RED 100 °F 38 °C IAITERAIIE lIOTC 17F�T VCI 1 GINI ]IR HIGH 2862F 1412E BLUE I 500F 660c: 2262F 1971E 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 JULY 2010 A -55 989 - 846 -4583 • FAX 989 - 846 -9231 BULLETIN GL5635, REV. #13 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH FINISHES 135 °F 57 °C 155 °F 68 °C cULus Variable *-�*rRT4RZ-9 5.6 (80 metric) 214" AF 1" NPT cULus 1 ^crrFvn PENDENT GL5635 6LBI35 to 48" Sa#+R re- X X X Bright Chrome X X 94 6 F e4i 8) X DIaak peIye6te. X X X p;; C NOTE: METRIC CONVERSIONS ARE APPROXIMATE. cULus LISTED CORROSION RESISTANT: POLYESTER MUST BE SPECIFIED ON ORDER. APPROVALS 'FINISHES AVAILABLE ON SPECIAL ORDER. 'LEAD COATED IS UL APPROVED ONLY. STYLE SIN MODEL KFACTOR THREADSIZE 135 °F 57 °C 155 °F 68 °C 175 °F 79oC 200 °F 93 °C 286 °F 141 °C� cULus NYC -DOB MEA 101-92-E PENDENT GL5635 6LBI35 5.6 -1-6 84 1" NPT 34 "�TIDT + "1A ,TI DT X X X X X X X X X X X X X - X X X X X X X X X RECESSED PENDENT GL5635 6L�P1RT 5.6 V NPT ain �TiDT X X X X X X X X X iij - X X X X X - X X NOTE: LISTED FOR ALL HAZARDS *PENDENT STYLE - FM APPROVED 155 °F, 200 °F, AND 286 °F *RECESSED PENDENT STYLE - FM APPROVED 155 °F AND 200 °F CROSS SECTIONS .EE F., N1 r Y, T11 FIT— �2� a,s.a LITM � ;fir, TEES m N�, NP, _E �N 2E�E�N� N1a' lN. 2'��, -" rti'1 °1`7 E.,N LEE 2�5 1 .11 3 2 ,22 11E L- a,sa IL �N� a,s. 2�LEE 3,apP, �EOEE °1N�2EI2N. zENa sPO� E521.21EO1 E �I SLEEVE & SKIRT PENDENT GL613E FIRE SPRINKLER CORPORATION IMPORTANT INSTALLATION DATA Globe GL Series Dry Pendent sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18 ". Excessive force may distort the frame thus destroying the unit. When installed in a wet system extending into a freezing area see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs. Please refer to our Dry Caution sheet for further important installation data. ORDERING INFORMATION SPECIFY • Quantity, Model Number -Style, Orifice • Temperature • Finishes desired • Quantity - Wrenches - P/N 333010 • Quantity - Recessed Wrenches - P/N 337014 • Quantity - Protective Caps - P/N 327109 -cap (Friction Fit Recessed) • Escutcheons desired • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used. GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufac- tured products found to be defective in material or workman- ship for a period of one year from date of shipment. For specific details of our warranty, please refer to Price List Terms and Conditions of Sale (Our Price List). 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989 - 846 -4583 FAX 989 - 846 -9231 1- 800 - 248 -0278 www.globesprinkler.com JULY2010 PRINTEDU.S.A. BULLETIN GL5635, REV. #13 PRODUCT HIGHLIGHTS FLEXIBLE SPRINKLER HOSE FITTINGS The most cost - effective sprinkler drop on the market SprinkFLEX Stainless Steel Sprinkler Fittings connect the branch line to the sprinkler head using a flexible stainless steel hose and reducer. The flexible stainless steel hose and fittings are intended for direct connection to the sprinkler and are particularly suited for use in suspended ceiling applications. Each drop assembly comes with one stainless steel flexible hose, one branch line connection nipple, one sprinkler reducing nipple and bracket system. Fully assembled for ease of installation One -piece brackets available in 24" and 48" width Open hub design allows the sprinkler head to be installed prior to bracket installation • No tools required for bracket installation • Compatible with pendant, semi - recessed and concealed sprinkler heads Hose lengths from 28" to 71 " long • Outlet sizes available in' /2 "and 3/4" Unbraided and braided hose assemblies Optional factory installed sprinkler head SprinkFLEX, LLC, 139A Charles Street #313, Boston, Massachusetts 02114 800 - 463- 1276(phone) 888 - 502- 3775(fax) sprinkflex @gmail.com www.sprinkflex.com Technical Data Maximum Working Pressure: 200 psi (1375 kPa) Maximum Ambient Temperature: 300° F (149 °C) Connection to Branch Line: 1 -inch NPT Minimum Bend Radius of Flexible Stainless Steel Hose: 3 inches (76.2 mm) Maximum Number of 90° Bends Per Flexible Stainless Steel Hose: 2 - 90 degree bends for 28" length 3 - 90 degree bends for 40', 48, 59 "and 71" lengths The flexible stainless steel hose should not be bent within 211z inches (64 mm) of the connection nut at both ends. Maximum K- Factor of Sprinkler to be connected to Sprinkler Reducing Nipple: '/z inch outlets: 8.0 3/4 inch outlets: 11.2 s m FLEXIBLE SPRINKLER HOSE FITTINGS SprinkFLEX,LLC. 139A Charles Street #313, Boston, Massachusetts 02114 800 - 463- 1276(phone) 888 - 502- 3775(fax) sprinkflex @gmail.com www.sprinkflex.com r/V ~VMM��a /Schedule -40� Fully Listed and FM Approved Sprinkler Pipe When you specify Se Schedule -40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, ce4 /Schedule -40 gives you the extra quality assurance you demand. Our ' 4" Sch -40 (1 "- 21/2 ") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Sch -40 Specificatic Sehedttle 10 product cas "hot -dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications ofASTMA -123. ions 2' /z" 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 Our advanced formula mill coating of- fers a clean, durable surface. It is also paint -ready for custom color applicat without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, `ABF ". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets `Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Se /Schedule -40 pipe are in compliance with the following: ASTM A -135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: • Welded Outlets • Hydrostatic Pressure • Side Wall Rupture • Vibration Test NPS N Nominal I.D. W Wt. W Wt. (H20 Filled) P Pcs/ W Wt/Lift (21') W Wt/Lift (24') W Wt/Lift (25') r be I In; mm I In; mm L Lbs /Ft, Kg /m L Lbs /Ft, Kg /m L Lift L Lbs; Kg L Lbs; Kg L Lbs; Kg Lbs /Ft, Kg /m 1.. 1 1.049 1 1.680 2 2.05 7 70 2 2,470 2 2,822 2 2,940 1.81 91 25 2 26.6 2 2.5 3 3.05 7 70 1 1,120 1 1,280 1 1,334 1,213 1' /a" 1 1.380 2 2.270 2 2.93 5 51 2 2,431 2 2,778 2 2,894 664 32 3 35.1 4 4.36 4 4.36 5 51 1 1,103 1 1,260 1 1,313 1,252 1' /z" 1 1.610 2 2.720 3 3.61 4 44 2 2,513 2 2,872 2 2,992 40 40 4 40.9 4 4.0 5 5.37 4 44 1 1,140 1 1,303 1 1,357 2 2" 2 2.067 3 3.650 5 5.13 3 30 2 2,300 2 2,628 2 2,738 5 50 5 52.5 5 5.4 7 7.63 3 30 1 1,043 1 1,192 1 1,242 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8. 30 1,009 1,153 1,201 3" 3.260 4.330 .94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 Our advanced formula mill coating of- fers a clean, durable surface. It is also paint -ready for custom color applicat without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, `ABF ". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets `Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Se /Schedule -40 pipe are in compliance with the following: ASTM A -135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: • Welded Outlets • Hydrostatic Pressure • Side Wall Rupture • Vibration Test tgCO /Flow Control Qr allied TUBE & CONDUIT UL FM ULC Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882 -5543 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708 - 339 -1806 S5 -3 Sch-10 Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') Wt/Lift (24') Wt/I.�it (25') In; mm In; mm Lbs /Ft, Kg /m Lbs /Ft, Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1, 5 1,445 11/4 1.442 1.810 2.52 61 2,319 664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1' /z" 1.682 2.080 3.04 61 2, 4 3,045 3,172 40 42.7 3.1 4.52 61 ,208 1,381 1,439 2" 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 7 930 1,063 1,108 2' /z" 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8. 30 1,009 1,153 1,201 3" 3.260 4.330 .94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4" 4.260 5.61 11.78 19 2,238 2,558 2,665 90 108.2 .3 17.53 19 1,015 1,160 1,209 5" 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134. 11.56 25.80 10 740 846 881 6" 7 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 16.490 40.15 7 2,424 2,770 2,885 X8.249 209.5 24.5 59.75 7 1,100 1,256 1,309 tgCO /Flow Control Qr allied TUBE & CONDUIT UL FM ULC Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882 -5543 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708 - 339 -1806 S5 -3 `V�� - U FM Anvil standard and extra heavy cast iron threaded fittings are C o u$ manufactured in accordance with ASME -1316.4 (except plugs APPROVED and bushings, ASME B16.14). Dimensions also conform to Federal For Listings /Approval Details and Limitations, visit our website @ Specifications, WW -P -S01 (except plugs and bushings WW -P -471). www.anvilintl.com or contact an Anvil /AnvilStar Sales Representative Cast Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 125 Class 250 ff) (10 psi bar psi bar -200 to 1500 -28.9 to 65.6 175 12.1 400 27.6 2000 93.3 165 11.4 370 25.5 2500 121.1 150 10.3 340 23.4 3000 148.9 140 9.7 310 21.4 3500 176.7 125 8.6 300 20.7 4000 204.4 — — 250 172 www.anvilintlxom PF -9.09 Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 90° Elbo n Size A A B Unit Weight Black �-B-- rA -I - i -� - - - - -- ---- � - - - - -- '- - B A NPS DN in mm in mm Ibs k 'l4 8 'l2 13 13/16 22 0.16 0.07 3/8 10 916 14 "/16 24 0.25 0.11 'l2 15 11/16 17 11/8 29 0.40 0.18 3/4 20 13/16 22 115/16 33 0.60 0.27 1 25 "/16 24 11/2 38 0.92 0.42 1' /4 32 11/8 29 13/4 44 1.44 0.65 1' /2 40 15/16 33 115/16 49 1.95 0.88 2 50 191 6 40 21/4 57 3.13 1.42 2' /2 65 113/16 47 211/16 68 4.94 2.24 3 80 23/16 56 31/8 79 7.21 3.27 3'/z 90 2'/16 62 3'h6 87 9.67 4.39 4 100 211/16 68 3 13 /16 98 12.17 5.52 5 125 3 5/ 16 84 41/2 114 21.46 9.73 6 150 3'/8 98 51/8 130 31.33 14.21 8 200 5 3/ 16 132 69/16 167 64.56 29.28 FIGURE 371 90° Elbow, Flange & Screw Size A B Unit Black NIPS DN in mm in mm Ibs k -- - - - - -- B - r - - - - -- '- - 2' /z 65 113/16 211/16 68 10.22 4.63 3 80 23/6 56 31/8 79 13.25 6.01 4 100 211/16 68 313/6 98 21.56 9.78 6 150 3'/8 98 51/8 130 40.50 18.37 tNominal Pipe Sizes of 4" (100 DN) and larger have two holes tapped for stud or tap bolts. Note: See page 37 for pressure- temperature ratings. /�11NI L PF -9.09 Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 358 Tee A B Unit Weight Black -- B-- ;<-B -� -- - --- j - - - -- A B - -- - - -- NPS DN in mm in mm Ibs k 1/4 8 1/2 13 13/16 22 0.22 0.10 3/8 10 5/8 16 1 25 0.35 0.16 '/z 15 11l16 17 11/8 29 0.56 0.25 3/4 20 13/1 6 22 15/1 6 33 0.84 0.38 1 25 5/, s 24 11 /z 38 1.25 0.57 11/4 32 11/8 29 13/4 44 2.03 0.92 11/2 40 15/16 33 115/16 49 2.70 1.22 2 50 191 6 40 1 21/4 57 1 4.23 1.92 21/2 65 113/16 47 211/16 68 6.67 3.02 3 80 23/,6 56 31/8 79 10.00 4.54 31/2 90 2'/16 62 3'h6 87 13.29 6.03 4 100 211/16 68 33/4 95 16.33 741 5 125 35h6 84 41/2 114 27.33 12.39 6 150 1 3'/8 98 51/8 130 1 40.85 18.53 8 200 1 53/,6 132 69/16 167 1 79.00 35.83 FIGURE 359 Tee Reducing - �- D--: - E A--< B -- -- } - -- r- C - F Size A B E I Unit Weight Black NPS DN NPS DN NPS DN in mm in mm in mm in mm in mm in mm Ibs k lz 15 /z 15 1/4 3/8 3/4 1 8 10 20 25 11/,6 11/16 13/16 1 17 17 22 25 11/16 11/16 13/16 1 17 17 22 25 13/16 3/4 11/16 13/1 6 22 19 17 22 11/8 11/8 11/4 1'/, 6 29 29 32 37 11/8 11/8 11/4 1'l, 6 29 29 32 37 11/8 11/8 13/16 13A 29 29 22 35 0.57 0.26 0.57 0.26 0.68 0.31 1.00 0.45 1/4 8 3/4 20 13/ 1 6 22 "/16 6 24 13/16 22 "/16 6 24 11/4 32 "/16 6 24 0.79 0.36 lz 15 1/2 3/4 15 20 11/16 13/,6 17 22 11/16 13/,6 17 22 13/16 13/16 22 22 13/16 15/16 22 24 11/8 11/4 29 32 11/4 15/16 32 24 0.64 0.29 0.75 0.34 3/4 20 3/4 20 1/4 3A 1/2 1 8 10 15 25 9/16 11/16 11/16 1'/, 6 14 17 17 24 9/16 11/16 11/16 1'/16 14 17 17 24 7/8 15/16 13/16 13/16 22 24 22 22 11/16 13/16 13/16 1'/, 6 17 22 22 37 11/16 13/16 13/16 1'l, 6 17 22 22 37 13/,6 11/4 11/4 13A 22 32 32 35 0.62 0.28 0.75 0.34 0.76 0.34 0.99 0.45 1/4 8 1 25 15/16 24 15/16 24 15/16 24 11/2 38 11/4 32 11/2 38 1.08 0.49 1/2 15 1/2 3/4 1 15 20 25 11/16 13/16 1'/, 6 17 22 24 3/4 13/16 "/16 19 22 24 15/16 15/16 15/16 24 24 24 11/4 13A 11 /2 32 35 38 13/16 11/4 13A 22 32 35 13A 1'/,6 11/2 35 37 38 0.90 0.41 0.91 0.41 1.08 0.49 1 25 3/4 20 1/2 3A 1 15 20 25 11/16 13/ 1 6 15/,6 17 22 24 11/16 13/, 6 15/16 17 22 24 15/16 15/16 15/16 24 24 24 11/4 13A 11/2 32 35 38 13/16 "/16 1'/,6 22 24 37 13A 1'/, 6 1 11/2 35 37 38 0.89 0.40 1.00 0.45 1.13 0.51 1 25 1/4 1/2 3/4 11/4 11/2 2 8 15 20 32 40 50 11/16 11/16 13/ 1 6 11/8 11/4 1'/, 6 17 17 22 29 32 37 11/16 11/16 13/, 6 11/8 11/4 1'l, 6 17 17 22 29 32 37 11/8 15/16 15/16 WiE; 1 1 29 24 24 24 25 25 11/8 11/4 13A 111/16 113/16 2 29 32 35 43 47 50 11/4 11/4 13A 111/16 113/16 2 32 32 35 43 47 50 13A 13A 1'l, 6 19/16 15/8 13/4 35 35 37 40 41 44 1.01 0.46 1.01 0.46 1.11 0.50 1.49 0.68 1.84 0.83 2.70 1.22 Note: See page 37 for pressure- temperature ratings. /�11NIL Continued on next page. PF -9.09 Cast Iron Threaded Fittings Class 125 (Standard) �BA FIGURE 367 -- Concentric Reducer A B Unit Weight Black NPS DN NPS DN in mm in mm Ibs k 3/4 20 '/2 15 5/8 16 19/16 40 0.40 0.18 1 25 1/2 (Hex) 15 3/4 (Hex) 20 11/16 17 '/16 11 111/16 43 11/2 38 0.54 0.24 0.63 0.29 1'/4 32 1/2 15 3/4 20 1 25 9/16 14 1 25 15/16 24 15 /s 41 2' /8 54 2' /8 54 0.84 0.38 0.90 0.41 1.07 0.49 1' /z 40 1/2 15 3/4 20 1 25 11/4 32 1/2 13 1/2 13 1/2 13 1 25 15 /s 41 15 /s 41 13/4 44 21/4 57 1.00 0.45 1.20 0.54 1.50 0.68 1.45 0.66 2 50 1/2 15 3/4 20 1 25 11/4 32 11/2 40 5/8 16 3/4 19 3/4 19 13/16 22 '/8 22 2 51 2 51 2 51 2' /8 54 23/16 56 2.00 0.91 1.90 0.86 1.83 0.83 1.78 0.81 1.98 0.90 2'/2 65 1' /2 40 2 50 3/4 19 1 25 2 51 29/16 65 3.10 1.41 2.98 1.35 3 80 3A 20 2 50 2' /2 65 15/16 24 11/16 27 15/16 24 2' /2 64 23/4 70 213/16 73 4.31 1.95 3.96 1.80 4.40 2.00 4 100 2 50 21/2 65 3 80 13/16 30 13/16 30 11/16 27 215/16 75 3' /8 79 3' /8 79 6.50 2.95 7.78 3.53 7.01 3.18 5 125 4 100 11/16 27 3 5/ 16 84 10.48 4.75 6 150 4 100 5 125 11/8 29 1' /8 29 3'h6 87 39h6 90 13.83 6.27 15.53 704 8 200 6 150 11/4 32 3'/8 98 29.10 13.20 Note: See page 37 for pressure- temperature ratings. /�11NI L PF -9.09 0 ■ Fig. 4L Longitudinal "In- Line" Sway Brace Attachment Size Range — 21/2" through 8" IPS. Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbance. Approvals — Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL) 21/2" - 8 ". Approved by Factory Mutual Engineering (FM), 21/2" - 8" pipe. Installation Instructions — The Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and /or OSHPD guidelines should be followed. To Install — Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set bolt until hex head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish — Plain Note — Available in Electro- Galvanized and HDG finish. Order By — Figure number, pipe size and finish. n Fob O r -7 it II i II I I I O Longitudinal Brace 4 -Way Riser Brace (Plan view) C UL US LISTED FM 5 93/4 37/8 43/8 1/2 2015 1450 380 6 111/2 5 51/8 1/2 2015 1450 640 8 131/4 55/8 55/8 1/2 2015 1450 728 * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin 0, where 0 the installation angle measured from the vertical. FM approved when used with 1 " 11/4", 11/2" or 2" Sch. 40 brace pipe. TOLCO® brand bracing components are designed to be compatible ONLY with other TOLCO° brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO° brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO° brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non -TOLCO brand bracing components have been, or are used. m OFFICE /MANUFACTURING FACILITY • 1375 SAMPSON AUF. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Dimensions • Weights Max. Rec. Max Design Sizes A C D Slile Load Lbs. Load Lbs. Approx. (cULus) (FM) 21/2 67/6 21/2 23/4 1/2 2015 3000 253 3 7 23/4 31 /is 1/2 2015 1550 268 4 81/2 33/8 311/16 1/2 2015 1550 348 5 93/4 37/8 43/8 1/2 2015 1450 380 6 111/2 5 51/8 1/2 2015 1450 640 8 131/4 55/8 55/8 1/2 2015 1450 728 * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin 0, where 0 the installation angle measured from the vertical. FM approved when used with 1 " 11/4", 11/2" or 2" Sch. 40 brace pipe. TOLCO® brand bracing components are designed to be compatible ONLY with other TOLCO° brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO° brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO° brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non -TOLCO brand bracing components have been, or are used. m OFFICE /MANUFACTURING FACILITY • 1375 SAMPSON AUF. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 0 ■ Fia. 98 - Rod Stiffener Fig-.�S� - Rod Stiffener w /Break -off Bolt Head Size Range — SjtscQs 3/8" thru 7/8" hanger rod Material — Carbon Ste-T'— Function — Secures channel to er rod for vertical seismic bracing. Approvals — Included in our Seismic aints Catalog approved by the State of California Office of Statewide Planning and Development OSHPD . For additional load s acin lacement information relatina to OSHPD oroiects, please refer to the O Seismic Restraint Systems Guidelines Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number kj 99 - All Thread Rod Cut to Length Size Range — e 31 8" thru 718" rod in 1 " increments Material — Carbon Steel Maximum Temperature — 750 °F Finish — Plain Note — Available in Electro- Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish —> Fig. 100 - All Thread Rod F1,11 Lpnnth Size Range — Secures 3/8" thru 11/2" rod in 10' lengths Material — Carbon Steel Maximum Temperature — 750 °F Finish — Plain Note — Available in Electro- Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod diameter and finish Component of State of California OSHPD Approved Seismic Restraints System -a FIG. 98 FIG. 98B ® OFFICE /MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp Rod 650 °F 3/8 730 1/2 1350 5/8 2160 12 3230 7/8 4480 ® OFFICE /MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650 °F wt. /100 1/4 240 12 -->3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 ® OFFICE /MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com �016 Ila] ■ Fig. 200 - "Trimline" Adjustable Band Hanger Fon Ono Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2 ") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. • (21/2" thru 8 ") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters' Laboratories listed (1/2" thru 8 ") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8 "). Conforms to Federal Specifications WW -H -171 E, Type 10 and Manufacturers Standardization Society SP -69, Type 10. Maximum Temperature — 650 °F Finish — Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By — Figure number and pipe size Note — Figure 20OR (import) with retainer ring and non - captured knurl nut. e eus UISTED FM +wr.wsv 31/2 3/8 Dimensions • Weights 73/8 51/4 600 Pipe >4 Rod Size 10mm 73/8 Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt. /100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 �0 1 3/8 8mm or 10mm 33/8 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 31/2 3/8 10mm 73/8 51/4 600 34 >4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE /MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX 951.737.0330 m CUSTOMER SERVICE • 800.786.5266 www.tolco.com �016 Ila] ■ Fig. 906 - Sway Brace Multi- Fastener Adapter CoofStateof Califorrnia nia 0 OS tSHPD Approved C US LISTED Seismic Restraints System Size Range — Use with 1 " and 11/4" TOLCO UL listed Fig. 900 Series Earthquake Brace Attachments. Material — Carbon Steel Application — Allows sway brace fittings to develop greater load carrying ability by providing multiple fastener attachments. The National Fire Protection (NFPA) provides information on fastener loads to various structures. Refer to NFPA 13 (2010) 9.3.5.9.1. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) only when used with TOLCO 900 Series Earthquake Brace Attachments. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development ( OSHPD). For additional load, spacing and placement infor- mation relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Instructions — The Fig. 906 is a multiple fastener structural attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with a TOLCO transitional attachment, "bracing pipe" and a TOLCO "braced pipe" attachment to form a complete bracing assem- bly. NFPA 13 and /or OSHPD guidelines should be followed. To Install — Attach the Fig. 906 to the structural surface as per fastener design guidelines. Attach other TOLCO transi- tional attachment fitting Fig. 909, 910, 980 or 986. Transitional fitting attachment can pivot for adjustment to proper brace angle. Finish — Plain Note — Available in Electro- Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number and specify dimensions H1 and H2. Dimensions • Weights Approx. A B C D H1 H2 Wt. /100 12 9 2 1/4 Specify Specify Varies H2 TOLCOO brand bracing components are desgined to be compatible ONLY with other TOLCOO brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCOO brand bracing components, in the instance that such TOLCOO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCOO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non -TOLCO brand bracing components have been, or are used. OFFICE /MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com �016 Ila] ■ Fig. 909 - No- Thread Swivel Sway Brace Attachment Size Range — 1 " bracing pipe. For brace pipe sizes larger than 1 " use TOLCO Fig. 980. Material — Carbon Steel, hardened cone point engaging screw Function — The structural component of a sway and seismic bracing system. Features — This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2010) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. No threading of the bracing pipe is required. Open design allows for easy inspection of pipe engagement. Application Note — The Fig. 909 is used in conjunction with the TOLCO Fig. 1000, Fig. 1001, Fig. 4 (A) or Fig. 4L pipe clamp, and joined together with bracing pipe. Sway brace assemblies are intend- ed to be installed in accordance with NFPA 13 (or TOLCO State of California OSHPD Approved Seismic Restraint Manual) and the manufacturer's installation instructions. The required type, number and size of fasteners used for the structure attachment fitting shall be in accordance with NFPA 13 and /or OSHPD. C & Us LISTED Component of State of Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (WL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development ( OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Instructions — The Fig. 909 is the structural or transi- tional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 4A, 413 or 4L to form a complete bracing assembly. NFPA 13 and /or OSHPD guidelines should be followed. To Install — Place the Fig. 909 onto the bracing pipe. Tighten the set bolt until head bottoms out on surface. Attachment can pivot for adjustment to proper brace angle. Finish — Plain Note — Available in Electro- Galvanized and HDG finish. Order By — Figure number, pipe size and finish. Dimensions • Weiahts Hole Size Max. Design. Max. Design Load Approx. Pipe Size A B H Load Lbs. Lbs. w/Washer Wt. /100 1 6 15/8 17/32 2015 2765 91 Available with hole sizes to accommodate up to 3/4" fastener. Consult Factory. roved stem i J TOLCO° brand bracing components are desgined to be compatible ONLY with other TOLCO° brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO° brand bracing components, in the instance that such TOLCO° brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO° brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non -TOLCO brand bracing components have been, or are used. OFFICE /MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Product Features • No pre - drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill /driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. Approvals Rod Size Part Number Model Screw D- Ultimate UL Test FM Test Box Qty Case 1/4" 8002957 GST 100 1/4 x 1" 210 (7/16° OSB) 25 125 670 (3/4" Ply) 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 GST 300 1/4 x 3" 2060 (Fir) 25 125 3/8" 8006957 GST .75 1/4 x 3/4" 564 (3/4" Ply) 25 125 3/8" 8007957 GST 10 1/4 x 1" 210 (7/16° OSB) 300 25 125 670 (3/4" Ply) Q Q 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 3/8" 8068925 GST 20 -SS 1/4 x 2" 1760 (Fir) 850 25 125 3/8" 8009925 GST 25 -380 3/8 x 2 -1/2" 2113 (Fir) 1500 25 125 3/8" 8010957 GST 30 1/4 x 3" 2060 (Fir) 1500 1475 25 125 #14 Black 3/8" 8069925 GST 30 -SS 1/4 x 3" 2060 (Fir) 25 125 Nut Driver Part # 8113910 3/8" 8011925 GST 40 1/4 x 4" 2180 (Fir) 25 125 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 1/2" 8013925 GST2 1/4x2" 1760 (Fir) 25 125 1/2" 8014925 GST 2.5 -380 3/8 x 2 -1/2" 2113 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 1/2" 8016925 GST4 1/4x4" 2180 (Fir) 25 125 1/2" 8017925 GST 6 1/4 x 6" 2230 (Fir) 25 125 #14 SW Red Nut Driver Part # 8114910 Swivel Head) for Wood Installs VERTICALLY to 17' in ,,.,,MMY and swivels up wood structut Product Features • Eliminates distortion of threaded rod. • Saves time from traditional methods. �f; • Accommodates up to 3'/z" x 12 pitch roof. • Reduces installation cost. • Allows 17° deflection from vertical. • Made in the U.S.A. Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Box Case Size Number D- Qty Qty 3/8" 8139957 SH -GST 20 1/4 x 2" 1257 (Fir) 1050 1475 25 125 125 a0 3/8" 8141957 SH -GST 30 1/4 x 3" 1720 (Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin -off feature which provides a fast and safe installation each time. When the face of the driver comes into Part # 8113910 contact with the material you are installing into, continue drilling until nut driverspins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. w (r- -V For the most up to date information, visit www-sammysuperscrew-com 4 MADE IN U.S.A COMP ^ W Not less than 2" nominal width Rod Size (1 -1/21 up to 3 -1/2" pipe, not less than 3" (2 -1/2 ") nominal width 4" & 5" pipe Floor Joist Minimum 2 -1/2" from bottom for Model branch lines. Minimum 3" from Ultimate Pullout (lbs) bottom for main lines. Exception: This Box Qty requirement shall not apply to 2" or / thicker nailing strips resting on top of / steel beams. Compositel"Truss Consult truss manufacturer for recommended installation point. re -drilling may be required for Model SWG 25-380 (tools available on pg 10 ) Product Features • No pre - drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill /driver. • Saves time from traditional methods. • Reduces installation cost. • Made in the U.S.A. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) Box Qty Casi Qty 1/4" 8018957 SWG 100 1/4 x 1" 622 (Fir) 25 125 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 O. 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 125 O. 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 3/8" 8073925 SWG 20 -SS 1/4 x 2" 1725 (Fir) 850 25 125 #14 SW Red • 3/8" 8022925 SWG 25 -380 3/8 x 2 -1/2" 2249 (Fir) 1500 25 125 Nut Driver 3/8" 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 Part # 8114910 1. Insert the appropriate nut driver into a 318" or 1!2" portable drill 2. Insert the SAMMYS into the # 14 (black) nut driver (p /n 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member When the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 114' 3/8' 1/2" or metric all thread rod, bolt stock. (The 112"requires the # 14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in pudin steel. 1. Insert the appropriate nut driver into a 3/8" or 1!2" portable drill. 2. Insert the SAMMYS into the # 14SW (red) nut driver (p /n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3. When the nut driver spins free on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 114' 3/8 "or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in pur in steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin -off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driverspins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Victaulic offers abroad line of fittings in sizes through 48 " /1200mm in a variety of straight and reducing styles. Most standard fittings are cast of durable ductile iron to precise tolerances. Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are supplied with grooves or shoulders to permit fast installation without field preparation. The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Viictaulic couplings for plain end pipe (refer to Section 14.04 for fillings available for plain end applications). Fittings are provided in various materials including ductile iron, steel or segmentally welded steel depending on styles and size. Fittings are painted orange enamel with a galvanized finish available as an option, contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping systems. Fittings are provided grooved or with shoulders conforming to standard steel pipe outside diameters. When connecting wafer or lug -type butterfly valves directly to Victaulic fittings with 741 or 743 Vic - Flange® adapters, check disc clearance dimensions with I.D. dimension of fitting. Note: The following Victaulic fittings are VdS approved: NO.10 90° Elbow, NO.11 45° Elbow, NO.20 Tee and NO.60 Cap. Note: The following Victaulic fittings are LPCB approved: NO.10 90° Elbow, NO.11 45° Elbow, NO.12 221/2° Elbow, NO.13 111 /a° Elbow, NO.30 45° Lateral, NO.30 -R Reducing Lateral, NO.100 Long Radius Elbow, NO.110 Long Radius Elbow, NO.20 Tee, NO.35 Cross, NO.60 Cap, NO.25 Reducing Tee, NO.33 True Wye, NO.50 Concentric Reducer, NO.51 Eccentric Reducer, NO.29M Tee with Threaded Branch, NO.27 Standpipe Tee, and NO.32 Tee Wye. AGS - ADVANCED GROOVE SYSTEM ALTERNATE STYLES NO. 20 TEE NO. 10 ELBOW Advanced Groove System — For 14 — 24 "7350 — 6O0mm piping systems, Victaulic now offers the Advanced Groove System (AGS). Refer to Section 20.05 for AGS fitting details. Stainless Steel — Grooved end fittings are available in Schedule 10 Type 316 stainless steel (Schedule 5, 40 and Type 304 available as an option) in various sizes. Fitting center -to -end dimensions will vary depending upon type and schedule. Refer to Section 17.04 and 17.16 for details. Aluminum — Grooved end fittings are available in aluminum alloy 356 T6, in sizes from 1 — 8 "725 — 200mm. Refer to Section 21.03 or contact Victaulic for details. Extra Heavy EndSeal® "ES" Fittings — EndSeal fittings are available in 2 — 12 "750 — 300mm for use with "ES" grooved pipe and HP -70ES EndSeal couplings. "ES" fittings are painted black for easy identification. EndSeal (and standard) fittings may be easily internally coated (by others) for severe service requirements. Always specify "ES EndSeal fittings" when ordering. See Section 07.03 for information on EndSeal fittings. Fittings Machined for Rubber or Urethane Lining (MIRE) — For severe abrasive services, Victaulic fittings may be rubber or urethane lined (by others). Lining may be inside diameter /end (abrasion resistance) or wrap- around (corrosion and /or abrasion) machined. Refer to Section 25.03 or contact Victaulic for specific details. Note: Fittings are available with a variety of coatings upon request such as hot dip galvanized, epoxy, glass lined and others. JOB /OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. �CtaLJIIC' REV_M 07.01_1 CARBON STEEL PIPE - GROOVED FITTINGS Grooved End Fittings MATERIAL SPECIFICATIONS 07.01 Fitting: Ductile iron conforming to ASTM A -536, grade 65- 45 -12. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request. • Or: Segmentally welded steel as shown under nipples Nipples: (adapter, swaged & hose) • 3/4 — 4720 — 100 mm: Carbon steel, Schedule 40, conforming to ASTM A -53, Type F • 5 — 67125 — 150mm: Carbon steel, Schedule 40, conforming to ASTM A -53, Type E or S, Gr. B • 8 — 127200 — 300mm: Carbon steel, Schedule 30 or 40, conforming to ASTM A -53, Type E or S, Gr. B Flanged Adapter Nipples: (Nipple — see above) • Class 125 Flange: Cast iron conforming to ANSI B -16.1 • Class 150 Flange: Carbon steel conforming to ANSI B -16.5, raised or flat face • Class 300 Flange: Carbon steel conforming to ANSI B -16.5, raised or flat face Fitting Coatings: Orange enamel • Optional: Hot dip galvanized and others. Some fittings supplied electroplated as standard — see product specifications. Flanged Adapter Nipple Coating: None (Unfinished) • Optional: Orange enamel, hot dip galvanized and others. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. +td V II C� 07.01_2 REV _M CARBON STEEL PIPE - GROOVED FITTINGS Grooved End Fittings 07.01 FLOW DATA The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given, for example, a 22V2' elbow is (Frictional Resistance) approximately one -half the resistance of a 45° elbow. Values of mid -sizes can be interpolated. Siz Dimension - Feet/meters El ,0. Elbows E bows Actual No. 00 No. 110 Outsi size Dia. Std. Long Std. Long 7Raddiluls In./mm In./mm Radius Radius Radius Branch 1 1.315 1.7 0.8 4.2 1J 25 33.7 0.5 0.2 1.3 0.5 2 2.375 3.5 2.5 1.8 1.1 8.5 3.5 50 60.3 1 1.1 0.8 0.5 1 0.3 2.6 1.1 3.000 4.3 2.1 10.8 4.3 76.1 mm 76.1 1.3 0.7 33 1.3 3 3.500 5.0 3.8 2.6 1.6 13.0 5.0 80 1 88.9 1.5 1 1.2 0.8 0.5 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108.0 mm 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 5.0 3.4 2.1 16.0 6.8 too 114.3 2.1 1.5 1.0 0.6 4.9 2.1 133.0 mm 5.250 8.1 4.1 20.0 8.1 133.0 2.5 1.2 1 6.2 2.5 5.500 8.5 4.2 21.0 8.5 139.7 mm 139.7 2.6 1.3 6.4 2.6 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1 1.3 6.4 26 6.250 9.4 4.9 25.0 9.6 159.0 mm 159.0 2.9 1.5 7.6 2.9 165.1 mm 6.500 9.6 5.0 25.0 10.0 165.1 2.9 1.5 7.6 3.0 6 6.625 10.0 7.5 5.0 3.0 25.0 10.0 150 168.3 3.0 2.3 1.5 0.9 7.6 3.0 8 8.625 13.0 9.8 6.5 4.0 33.0 13.0 200 219.1 4.0 3.0 2.0 1.2 10.1 4.0 10 10.750 17.0 12.0 8.3 5.0 41.0 17.0 250 273.0 5.2 3.7 2.5 1.5 12.5 5.2 12 12.750 20.0 14.5 10.0 6.0 50.0 20.0 300 323.9 6.1 4.4 3.0 1.8 15.2 6.1 14 14.000 24.5 § 15.8 18.5 § 11.0 70.0 23.0 350 355.6 7.5 4.8 5.6 3.4 21.3 7.0 16 16.000 28.0 § 18.0 21.0 § 13.0 80.0 27.0 400 1 406.4 8.5 1 5.5 6.4 4.0 1 24.4 8.2 18 18.000 31.0 § 20.0 23.5 § 14.0 90.0 30.0 450 457.0 9.5 6.1 7.2 4.3 27.4 9.1 20 20.000 34.0 § 22.5 25.5 § 16.0 100.0 33.0 800 508.0 10.4 6.9 7.8 4.9 30.1 '2' 24 24.000 42.0 § 27.0 29.5 § 19.0 120.0 40.0 600 610.0 12.8 8.2 9.0 5.8 36.6 12.2 26 26.000 # 28.0 # 20.5 130.0 43.0 650 660.4 8.5 6.3 39.6 13.1 30 30.000 34.0 24.0 150.0 50.0 750 762.0 # 10.4 # 7.3 45.7 15.2 36 36.000 # 40.5 # 28.5 180.0 60.0 900 914.0 42.000 12.3 8.7 54.9 18.3 210.0 70.0 42 47.0 33.0 1050 1067.0 # 14.3 # 10.1 64.0 21.3 # Contact Victaulic for details- 4 For use on cut grooved systems only. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. § Fitting flow data for 14 247350 -600 mm size NO. 10 and NO. 11 Elbows is based on fittings for Style 07 and 77 couplings. For flow data on AGS fittings ( NO. W10 and NO. Wll Elbows), refer to submittal 2005 .. Note- All fittings are ductile iron unless otherwise noted with an "sw" or "s SW= Segmentally Welded. S= Carbon Steel www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. �CtaLJ�IC REV_M 07.01_3 CARBON STEEL PIPE - GROOVED FITTINGS Grooved End Fittings DIMENSIONS Elbows NO. 10 90' Elbow PI/) 1q 7714' Plke.. PI/) 14 111/' Pll;.&... CtoE NO. 110 4 F3' rEft Rad HS- C I to E ;L- , NO. 10 E to E CtoF C to ONO NO. 11 . 07.01 Imo- C to E y I I CtoE A01 NO. 100 NO. 110 Note: All fittings are ductile iron unless otherwise noted with an "sw" or "s SW= Segmentally Welded. S= Carbon Steel www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 07.01_4 ✓ctaulic° REV _M Size 90' Elbow 45' Elbow 22W Elbow (sw) 11�/.Elbow (sw) �• Nominal Actual App Inches Inches Inches Lbs. Approx. Inches Lbs. ."FOX. Inches mm mm mm kg 3/4 1.050 2.25 0.5 MM kg 1.50 NQ.5 1.63 sw mm 1.38 sw 20 26.9 57 0.2 38 0. 41 35 1.38 sw 0.3 1 1.315 2.25 0.6 1.75 0.6 3.25 @ 0.6 25 33.7 57 0.3 44 0.3 83 0.3 35 0.1 1.660 2.75 1.75 0.9 .75 0.8 11/4 1.0 1.38 sw 0.5 32 42.4 70 0.5 44 0.4 0.4 35 0.2 1.38 sw 0.5 11/1 1.900 2.75 1.2 1.75 0.9 1.75 0.8 40 48.3 70 0.5 44 0.4 44 0.4 35 0.2 2 2.375 3.25 1.8 2.00 1.3 3.75 @ 1.4 1.38 1.0 4.3 2.5 2.75 1.8 50 60.3 83 0.8 51 0.6 95 35 0.5 1 1.1 70 0.8 21/2 2.875 3.75 3.2 2.25 2.2 4.00 @ 2.3 1.50 1.1 5.13 3.4 3.00 2.8 65 73.0 95 1.5 57 1.0 102 1.0 38 0.5 130 1.5 76 1.3 3.000 3.75 3.7 2.25 3.4 2.24 1.50 76.1 mm 76.1 95 1.7 57 1.5 57 3 3.500 4.25 4.5 2.50 3.1 4.50 @ 3.1 1.50 2.1 5.88 6.0 3.38 4.9 80 88.9 108 2.0 64 1.4 114 1.4 38 1.0 149 2.7 86 2.2 31/2 4.000 4.50 5.6 2.75 4.3 2.50 sw 4.0 1.75 2.7 90 101.6 114 2.5 70 2.0 64 1.8 4 4.500 5.00 7.1 3.00 5.6 2.88 5.6 1.75 3.6 7.50 12.3 4.00 7.3 100 114.3 127 3.2 76 2.5 73 2.5 44 1.6 191 5.6 102 3.3 108.0 mm 4.250 5.00 11.0 3.00 5.6 108.0 127 5.0 76 2.5 41/2 5.000 5.25 sw 10.0 3.13 sw 6.0 3.50 5.6 1.88 sw 4.2 120 127.0 133 4.5 79 2.7 89 3.0 48 1.9 5 5.563 5.50 11.7 3.25 8.3 2.88s 7.8 2.00 sw 5.0 18.2 14.8 125 141.3 140 5.3 83 3.8 7 3.5 51 2.2 + 3 + 6.7 5.250 5.50 11.7 3.25 8.3 133.0 mm 133.0 140 5.3 83 3.8 139.7 mm 5.500 5.50 11.7 3.25 8.3 2.87 2.00 139.7 140 5.3 83 3. 73 51 6 6.625 6.50 17.2 3.50 0.8 6.25 @ 12.2 2.00 7.0 10.75 30.4 \1407.9 .4 150 168.3 165 7.8 89 4.9 159 5.5 51 3.2 273 13.8 159.0 mm 6.250 6.50 18.6 3.50 10.8 159.0 165 8.4 89 4.9 6.500 6.50 15.5 9.8 3.13 11.4 2.00 7.4 10.75 29.0 5.50 19. 165.1 mm 165.1 165 7.0 .50 89 4.4 79 5.2 51 3.4 273 13.2 140 8.6 Note: All fittings are ductile iron unless otherwise noted with an "sw" or "s SW= Segmentally Welded. S= Carbon Steel www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 07.01_4 ✓ctaulic° REV _M CARBON STEEL PIPE - GROOVED FITTINGS Grooved End Fittings Tees, Crosses and True Wyes NO. 20 Tee CtoF -I NO. 35 GFE355 NO. 33 Wye - - - - - -- -T Ale) 7[1\�TJ�T'rCC- IYTLTIT•••• •••: }L• C to F NO. 20 CtoL I I NO 35 CtoL/N C to SL NO. 33 07.01 C to �F C toTL NO. 29M it . 33 Size Tee Cross (sw) True Wye (sw) Nominal Actual Approx. Approx. Approx. No. 29M �I Tee with Threaded Branch Apre Size Outside Dia. C to E Weight Each C to qE Weight Each C to IE C to SE Weight Each Inches Inches nc es Lbs. Irches Lbs. Inches Inches Lbs. mm mm mm kg mm kg mm mm kg 3/4 1.050 2.25 0.6 2.25 0.9 C to GE C to TE Wei�nt Each Inches Inches Lbs. mm mm kg 2.25 2.25 0.6 20 26.9 57 0.3 57 0.4 57 57 0.3 2.25 2.2 1.0 1 1.315 2.25 1.0 2.25 1.3 2.25 2.25 1.1 25 33.7 57 0.5 57 57 57 0.5 57 2.75 2.75 0.5 1.5 11/4 1.660 2.75 1.5 2.75 2.1 2.50 1.5 32 42.4 70 0.7 2.0 70 2.75 1.0 64 0.7 70 70 07 1 Y2 1.900 2.75 2.5 2.75 1.8 2.75 2.75 2.0 40 48.3 70 0.9 70 1.1 K70 70 0.8 70 70 0.9 2.375 3.25 3.8 2.75 2.5 3.2 4.25 3.00 2 3.0 3.25 50 60.3 83 1.4 83 1.7 70 1.1 108 1.4 2.875 3.75 6.1 3.00 4.3 3.75 3.75 4.3 21/2 4.3 3.75 65 73.0 95 2.0 95 2.8 76 2.0 95 95 2.0 5.2 (sw) 3.000 3.75 5.2 3.75 3.75 76.1 mm 76.1 95 2.4 95 95 2.4 3 3.500 4.25 6.8 4.25 10.5 4.25 .25 6. 4.25 6.00 6.8 80 88.9 108 3.0 108 4.8 108 108 152 3.1 31/2 4.000 4.50 (sw) 7.9 4.50 11.5 4.50 3.50 9.6 4.50 4.50 7.9 (sw) 90 101.6 114 3.6 114 5.2 114 89 4.4 114 114 73.6 108.Omm 4.250 5.00 15.5 5.00 5.00 15.5 108.0 127 7.0 127 127 7.0 4 4.500 5.00 11.9 5.00 15.8 5.00 3.7 0.0 5.00 7.25 11.9 100 114.3 127 5.4 127 7.2 127 127 5.25 184 5.25 5.4 15.0 (sw) 41/2 5.000 5.25 (sw) 15.0 5.25 18.5 120 127.0 133 6.8 133 8.4 133 133 6.8 133.Omm 5.250 5.50 17.8 5.50 5.50 17.8 133.0 140 8.1 140 140 8.1 139.7mm 5.500 5.50 17.8 .50 5.50 17.8 139.7 140 8.1 1 5.50 140 8.1 5 5.563 5.50 17.8 5.50 20.0 5.50 4.00 15.0 5.50 17.8(sw) 125 141.3 140 8.1 140 9.1 140 102 6.8 140 140 8.1 159.Omm 6.250 6.50 27.1 6.50 6.50 27.1 159.0 165 12.3 165 165 12.3 165.1 mm 6.500 6.50 22.0 6.50 28 6.50 50 22.0 165.1 165 10.0 165 .7 165 1 10.0 6 6.625 6.50 25.7 6.50 28.0 6.50 4.50 22.3 6.50 6.50 25.7(sw) 150 168.3 165 11.7 165 12.7 165 114 10.1 165 165 11.7 8 8.625 7.75 47.6 7.75 48.0 7.75 6.00 36.0 7.75 7.75 47.6(sw) 200 219.1 197 21.6 197 21.8 197 152 16.3 197 197 21.6 10 10.750 9.00 99.0 9. 121.5 9.00 6.50 69.9 9.00 9.00 .0 250 273.0 229 44.9 9 55.1 229 155 31.7 229 229 3 12 12.750 10.00 133.0 10.00 110.0 10.00 7.00 80.0 10.00 10.00 99.0 300 323.9 254 60.3 254 49.9 254 178 36.3 254 254 44.9 Note: All fittings are ductile iron unless otherwise noted with an "sw" or "s SW= Segmentally Welded. S= Carbon Steel www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 07.01_8 ✓ctaul�c° REV _M CARBON STEEL PIPE - GROOVED FITTINGS Grooved End Fittings Cap NO. 60 ' b NO. 60 Size No. 60 Cap orninal Actual Size Outside Diameter Inches Inches L T pp Thickness e�,ghlrolx:ach Inches Lbs. L:A mm mm 3/4 1.050 Mm kg 0.88 0.2 20 26.9 22 0.1 1 1.315 0.88 0.3 25 33.7 22 0.1 1 Y4 1.660 0.88 0.3 32 42.4 22 0.1 Pk 1.900 0.88 0.5 40 48.3 22 0.2 2 2.375 0.88 0.6 50 60.3 22 0.3 21/2 2.875 0.88 1.0 65 73.0 22 0.5 3.000 0.88 1.2 76.1 mm 76.1 22 0.5 3 3.500 0.88 1.2 80 88.9 22 0.5 31/2 4.000 0.88 2.5 90 101.6 22 1.1 108.Omm 4.250 1.00 2.3 108.0 25 1.0 4 4.500 1.00 2.5 100 114.3 25 1.1 5.250 1.00 4.5 133.Omm 133.0 25 2.0 139.7 mm 5.500 1.00 4.5 139.7 25 2.0 5 5.563 1.00 4.6 125 141.3 25 2.1 159.Omm 6.250 1.00 6.8 159.0 25 3.1 6.500 1.00 7.3 165.1 mm 165.1 25 3.3 07.01 IMPORTANT NOTES: * Steel dish caps available through 247600 mm, contact Victaulic. No. 60 cap is not suitable for use in vacuum service with Style 72 or 750 couplings. No. 61 bull plugs should be used, see pg. 35. # For use on cut grooved systems only. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. Note: All fittings are ductile iron unless otherwise noted with an "sw" or "s SW= Segmentally Welded. S= Carbon Steel www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. +ta V ICS REV_M 07.01_19 INSTALLATION Reference should always be made to the 1 -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. UPDATED 1012009 07.01 1449 REV M iictaullli® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 07.01 Victaulic® Firelock"' Rigid Coupling ✓ ct —au lic� Style 009N 10.64 i' Patented 1.0 CERTIFICATION /LISTINGS c us <FM > LPCB VdS LISTED C104 -1a/36 2.0 PRODUCT DESCRIPTION • The FireLock EZTM Style 009N Installation- ReadyTM Rigid Coupling is for use in the fire protection market. • The coupling's unique design eliminates loose parts, promotes consistent installation and provides substantial gains in productivity. • IMPORTANT: FireLock EZTM Style 009N couplings are recommended for use ONLY on fire protection systems. 3.0 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A 536, Grade 65- 45 -12. Ductile iron conforming to ASTM A 395, Grade 65- 45 -15, is available upon special request. Housing Coating: (specify choice) ❑ Orange enamel (North America, Asia Pacific) ❑ Red enamel (Europe) ❑ Hot dipped galvanized Gasket: (specify choice') ❑ Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts /Nuts: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 10.64 7072 Rev G Updated 1012014 © 2014 Victaulic Company. All rights reserved. t 1 �caul�c® victaulic.com I Couplings I Fire Lock I Rigid I Style 009N I Publication 10.64 4.0 LISTINGS /APPROVAL 2 The information provided below is based on the latest listing and approval data at the time of publication. Listings /Approvals are subject to change and /or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Nominal Size WLus FM Vds LPCB Sch.5 Sch.10 Sch.40 Sch.5 Sch.10 Sch.40 inches psi psi psi psi psi psi psi psi mm kPa kPa kPa kPa kPa kPa kPa kPa 11 /a 232 365 365 175 363 363 363 363 32 1600 2517 2517 1205 2502 2502 2500 2500 11 /2 232 365 365 175 363 363 363 363 40 1600 2517 2517 1205 2502 2502 2500 2500 2 363 365 365 175 363 363 363 363 50 2502 2517 2517 1205 2502 2502 2500 2500 21/2 N/A 365 365 175 363 363 363 363 65 2517 2517 1205 2502 2502 2500 2500 3653 3634 363 363 76.1 mm N/A 25173 N/A N/A 25024 N/A 2500 2500 3 N/A 365 365 175 363 363 363 363 80 2517 2517 1205 2502 2502 2500 2500 4 N/A 365 365 175 363 363 363 363 100 2517 2517 1205 2502 2502 2500 2500 108.Omm N/A N/A N/A 3 N/A N/A 365 1175 2502 2 5 N/A 290 N/A 363 363 232 N/A 125 2000 2517 2502 2502 1600 363 a 133.0mm N/A N/A N/A N/A 4 N/A N/A N/A 363 232 139.7mm N/A 200055 N/A N/A 4 N/A N/A 363 159.0mm N/A N/A N/A N/A 2502 4 N/A N/A N/A 165.1 mm N/A 20006 N/A N/A 250 4 N/A N/A N/A 6 N/A 290 365 N/A 363 363 232 N/A 150 2000 2517 2502 2502 1600 363 216.0mm N/A N/A N/A N/A 2502 4 N/A N/A N/A 8 N/A 290 365 N/A 363 363 232 N/A 200 2000 2517 2502 2502 1600 2 Listed /Approved for wet and dry pipe systems (> — 40 °F / -40 °C) for continuous use in freezing conditions, use of Style 005H Coupling with Silicone Gasket is recommended. Please see the Victaulic Installation Manual 1- 009N /009H for details concerning when supplemental lubrication is required. 3 cULus listed for DIN 2458 2.6 mm pipe wall. 4 FM approved for BS 1387 Medium 3.6 mm pipe wall. 5 cULus listed for EN 10220 4.0 mm pipe wall. 6 cULus listed for EN 10255 4.5 mm pipe wall. 10.64 7072 Rev G Updated 1012014 © 2014 Victaulic Company. All rights reserved. victaulic.com ✓ctauliic® victaulic.com I Couplings I Fire Lock I Rigid I Style OO9N I Publication 10.64 4.1 LISTINGS /APPROVAL Speciality Pipe Pipe Size Pressure Rating Pipe Size Pressure Rating Pipe Size Pressure Rating cULus FM cULus FM cULus FM inches psi psi inches psi psi inches psi psi kPa kPa kPa kPa kPa kPa BLT 11/4-2 300 365 EZT 11/4-2 300 365 MT 11/4-2 300 365 2068 2517 2068 2517 2068 2517 DF 11/4-4 300 365 FF 11/4-4 300 365 MLT 11/4-2 N/A 365 2068 2517 2068 2517 2517 DT 11/4 -2 300 365 FILE 11/4-4 N/A 365 ST 11/4-2 N/A 365 2068 2517 2517 2517 EF 11/4-4 175 175 FLT 11/4-2 N/A 365 STF 11/4-4 N/A 365 1206 1206 2517 2517 EL 11/4-2 300 365 FLTL 11/4-2 N/A 365 TF 21/4-4 N/A 365 2068 2517 2517 2517 ET40 11/4-2 300 365 GL 11/4-2 300 365 WLS 11/4-2 300 365 2068 2517 2068 2517 2068 2517 EZF 3 -4 300 365 ME 11/4-4 300 365 WST 11/4-2 N/A 365 2068 2517 2068 2517 2517 XL 11/4-2 300 365 2068 2517 NOTES • BLT =BLT steel pipe manufactured by Allied Tube & Conduit Corp. • OF — DYNA -FLOW steel pipe manufactured by Allied Tube & Conduit Corp. • DT — DYNA -FLOW steel pipe manufactured by Allied Tube & Conduit Corp. • EF — EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • EL — EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • ET40 — Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • EZF — EZ -Flow steel pipe manufactured by Northwest Pipe Co. • EZT — EZ- Thread steel pipe manufactured by Youngstown Tube Co. • FF — Fire -Flo steel pipe manufactured by Youngstown Tube Co. • FILE — Fire -Line Flow steel pipe manufactured by Western International Forest Products Inc. • FLT — Fire -Line Threadable steel pipe manufactured by Western International Forest Products Inc. • FLTL — Fire -Line Threadable Light steel pipe manufactured by Western International Forest Products Inc. • GL — GL steel pipe manufactured by Wheatland Tube Co. • ME — Mega -Flow steel pipe manufactured by Wheatland Tube Co. • MT — Mega- Thread steel pipe manufactured by Wheatland Tube Co. • MILT — MILT steel pipe manufactured by Wheatland Tube Co • ST — STD wall pipe in accordance with ASTM A53. • STF — Steady Flow steel pipe manufactured by AMS Tube Corp. • TF — Tex -Flow steel pipe manufactured by Tex -Tube Co. • WLS — WLS steel pipe manufactured by Wheatland Tube Co. • WST — WST steel pipe manufactured by Wheatland Tube Company. • XL — XL steel pipe manufactured by Allied Tube & Conduit Corp. 10.64 7072 Rev G Updated 1012014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 ✓ctauliic® victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 5.0 DIMENSIONS Style 009N Y Z Y Z X X Style 009N Pre - Assembled Style 009N Joint Assembled (Push On Condition) 7 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See the Listings /Approvals section of this publication for ratings on other pipe. 8 The allowable pipe separation dimension shown is for system layout purposes only. FireLock EZTM couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 9 Number of bolts required equals number of housing segments. NOTES • When assembling FireLock EZTM couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZTM Style 009N couplings, use FireLock No. 006 end caps containing the " EZ° marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non - Victaulic end cap products shall not be used with Style 009N couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N coupling. There is no interchanging of gaskets or housings between coupling styles. • Use Of Flushseal Gaskets For Dry Pipe Systems FireLock EZTM couplings are supplied with FireLock EZTm Grade "E" Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic Flush- SeaITM gaskets are not compatible and cannot be used with the FireLock EZTM couplings. 10.64 7072 Rev G Updated 1012014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 ✓ctaulilc® Dimensions Pre - assembled Actual Maximum Maximum Allow. Approx. Nominal Outside Working End Pipe End Bolt /Nut 9 (Push On Condition) Joint Assembled Weight Size Diameter Pressure 7 Load 7 Separation$ Size X Y X Y Z Each inches inches psi lbs. inches inches inches inches inches inches inches lbs. mm mm kPa N r No. mm mm mm mm mm mm kg 1 'A 1.660 365 790 0.10 3/8 x 2 3.13 5.00 2.75 5.00 2.00 1.4 32 42.4 2517 3514 2.54 2 M10 x 2 79 127 70 127 51 0.6 1 1/2 1.900 365 1035 0.10 3/8 x 2 3.38 5.13 3.00 5.13 2.00 1.5 40 48.3 2517 4604 2.54 2 M10 x 2 86 130 76 130 51 0.7 2 2.375 365 1616 0.12 3/8 x21 /2 4.00 5.63 3.50 5.63 2.00 1.9 50 60.3 2517 7193 3.05 2 M10 x 21/2 102 143 89 143 51 0.9 21/2 2.875 365 2370 0.12 3/8 x 21/2 4.50 6.13 4.00 6.13 2.00 2.1 65 73.0 2517 10542 3.05 2 M10 x 21/2 114 156 102 156 51 1.0 3.000 365 2580 0.12 3/8 x 21/2 4.63 6.00 4.13 6.13 2.00 2.1 76.1 mm 76.1 2517 11476 3.05 2 M10 x 21/2 118 152 105 156 51 1.0 3 3.500 365 3512 0.12 3/8 x 21/2 5.13 6.75 4.63 6.75 2.00 2.3 80 88.9 2517 15622 3.05 2 M10 x 21/2 130 171 117 171 51 1.0 4 4.500 365 5805 0.17 3/8 x 21/2 6.00 7.88 5.63 7.50 2.13 2.9 100 114.3 2517 25822 4.32 2 M10 x 21/2 152 200 143 191 54 1.3 4.250 365 5175 0.17 3/8 x 21/2 5.63 7.38 5.38 7.38 2.13 3.1 108.Omm 108.0 2517 23020 4.32 2 M70x21 /2 152 1.87 137 187 54 1.4 5 5.563 365 8870 0.17 1/2 x 3 7.25 9.25 6.75 9.13 2.25 5.0 125 141.3 2000 39456 4.32 2 M12 x 3 184 235 171 232 57 2.3 5.250 365 7897 0.17 1/2 x 3 6.63 9.00 6.38 9.00 2.25 4.8 133.0 mm 133.0 2517 35106 4.32 2 M12 x 3 168 229 162 229 57 2.2 5.500 365 8667 0.17 1/2 x 3 6.88 9.25 6.75 9.13 2.25 4.9 139.7 mm 139.7 2517 38529 4.32 2 M12 x 3 175 235 171 232 57 2.2 6.250 365 11192 0.17 1/2 x 31/4 7.88 10.00 7.38 9.88 2.25 5.6 159.0 mm 159.0 2517 49753 4.32 2 MI x 31/4 200 254 187 251 57 2.5 6.500 365 12105 0.17 1/2 x 31/4 8.00 10.25 7.75 10.13 2.25 6.0 165.1 mm 165.1 2517 53813 4.32 2 MI x 31/4 203 260 197 257 57 2.7 6 6.625 365 12582 0.17 1/2 x 31/4 8.38 10.38 7.88 10.13 2.25 6.0 150 168.3 2000 44469 4.32 2 M72 x 3 1/4 213 264 200 257 57 2.7 8.500 365 20712 0.17 5/8 x 4 10.63 13.25 10.25 10.13 2.63 11.4 216.0 mm 216.0 2517 55968 4.32 2 M16 x 4 270 337 260 257 67 5.2 8 8.625 365 21326 0.17 5/a x 4 10.88 13.38 10.25 13.13 2.50 11.4 200 219.1 1620 94863 4.32 2 M16 x 4 276 340 260 333 64 5.2 7 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See the Listings /Approvals section of this publication for ratings on other pipe. 8 The allowable pipe separation dimension shown is for system layout purposes only. FireLock EZTM couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 9 Number of bolts required equals number of housing segments. NOTES • When assembling FireLock EZTM couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZTM Style 009N couplings, use FireLock No. 006 end caps containing the " EZ° marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non - Victaulic end cap products shall not be used with Style 009N couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N coupling. There is no interchanging of gaskets or housings between coupling styles. • Use Of Flushseal Gaskets For Dry Pipe Systems FireLock EZTM couplings are supplied with FireLock EZTm Grade "E" Type A gaskets. These gaskets include an integral pipe stop, that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard Victaulic Flush- SeaITM gaskets are not compatible and cannot be used with the FireLock EZTM couplings. 10.64 7072 Rev G Updated 1012014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 ✓ctaulilc® victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 6.0 REFERENCE MATERIALS Publication 05.01: Seal Selection Guide 1- 009N /009H: Installation Instructions FireLock EZTm Rigid Coupling User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end -use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and /or methods of use in the United States and /or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the 1- 009N /1 -009H Firelock EZ Rigid Coupling Installation Instructions for the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic, FireLock EZT., Flush-SeaIT"', and Installation - Ready— are trademarks or registered trademarks of Victaulic Company, and /or its affiliated entities, in the U.S. and/ or other countries. 10.64 7072 Rev G Updated 1012014 © 2014 Victaulic Company. All rights reserved. victaulic.com 1.7 ✓ctauhi Victaulic® Flexible Coupling Style 75 Exaggerated for clarity Approvals /Listings FM 1 t TP �P7Cg u� �c VdS See Victaulic publication 10.01 for details See Victaulic publication 02.06 for portable water approvals if applicable. Product Description Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50% lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500 psi /3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot -dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade "EHP" or "T" gaskets is the Style 177 installation -ready flexible coupling. For all available sizes, the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade "EHP" or "T" gaskets. Contact Victaulic for further details. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference publication 17.09 for pressure ratings and end loads. When used on light wall stainless steel pipe, the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel, refer to publication 17.01. Job /Owner ✓ct -au lrc� 06.05 0 A WARNIN A� • Victaulic RX roll sets must be used when grooving light- wall /thin -wall stainless steel pipe for use with Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving light- wall /thin -wall stainless steel pipe may cause joint failure, resulting in serious personal injury and /or property damage. NOTICE • Victaulic RX grooving rolls must be ordered separately. They are identified by a silver color and the designation RX on the front of the roll sets. Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Couplings I Flexible I Style 75 1 Publication 06.05 06.05 1470 Rev 0 Updated 09/2014 © 2014 Victaulic Company. All rights reserved. 1 ✓ctaulrc® victaulic.com I Couplings I Flexible I Style 75 1 Publication 06.05 Material Specifications Housing: Ductile iron conforming to ASTM A -536, grade 65- 45 -12. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request. Housing Coating: (specify choice) ❑ Standard: Orange enamel. ❑ Optional: Hot dipped galvanized and others. Gasket: (specify choice') NOTE: Additional gasket styles are available. Contact Victaulic for details. ❑ Grade "E" EPDM EPDM (Green stripe color code). Temperature range —30 °F to +230 °F / -34 0C to +110 °C. May be specified for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services. UL Classified in accordance with ANSI /NSF 61 for cold +73 0F423 0C and hot +180 °F / +82 0C potable water service and ANSI /NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES. ❑ Grade "T" Nitrile Nitrile (Orange stripe color code). Temperature range 20 °F to +180 017/29 0C to +82 °C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not compatible for hot water services over +150 °F / +66 0C or for hot dry air over +140 °F / +60 0C. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts /Nuts: Heat - treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A -449 and physical requirements of ASTM A -183 06.05 1470 Rev 0 Updated 09/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 ictaulic® victaulic.com I Couplings I Flexible I Style 75 1 Publication 06.05 Dimensions Style 75 rr �� rr ICI ri X FA 2 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 3/a - 3 V2"120 - 90 mm; 25% for 47100 mm and larger. 4 Number of bolts required equals number of housing segments. General Notes Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1' /2 times the figures shown. 06.05 1470 Rev 0 Updated 09/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 ictaulic® Actual Maximum Maximum Allow. Dimensions Approx. Nominal Outside Working End Pipe End Deflection from Weight Size Diameter Pressure z Load 2 Separation' Centerline' Bolt/Nut' X Y Z Each Pipe inches inches psi Ibs. inches Per Cplg. inches /ft. inches inches inches Ibs. mm mm kPa N mm Degrees mm /m (No.) size inches mm mm mm kg 1 1.315 500 680 0 -0.06 0.57 2.38 4.27 1.77 1.3 2 ° -43' 2 '/a x 2 25 33.4 3450 3025 0 -1.6 48 61 108 45 0.6 11 /a 1.660 500 1080 0 -0.06 0.45 2.68 4.61 1.77 1.4 2 ° -10' 2 '/a x 2 32 42.2 3450 4805 0 -1.6 38 68 117 45 0.6 11 /z 1.900 500 1420 0 -0.06 0.40 2.91 4.82 1.77 1.5 11-56' 2 '/a x 2 40 48.3 3450 6320 0 -1.6 33 74 122 45 0.6 2 2.375 500 2215 0 -0.06 0.32 3.43 5.22 1.88 1.7 1 ° 31 2 '/a x 2 50 60.3 3450 9860 0 -1.6 26 87 133 48 0.8 21/2 2.875 500 3245 0 -0.06 0.26 3.88 5.68 1.88 1.9 11-15' 2 -' /a x 2 65 73.0 3450 14440 0 -1.6 22 98 144 48 0.9 3.000 500 3535 0 -0.06 0.26 4.00 5.90 1.88 1.9 76.1 m m 11-12' 2 '/a x 2 76.1 3450 15730 0 -1.6 22 102 150 48 0.9 3 3.500 500 4800 0 -0.06 0.22 4.50 7.00 1.88 2.9 1 ° 2 2 1/2 x 2 3/a 80 88.9 3450 21360 0 -1.6 18 114 178 48 1.3 31/2 4.000 500 6300 0-0.06 0.19 5.00 7.50 1.88 2.9 00-54, 2 1/2 x 2 3/a 90 101.6 3450 28035 0 -1.6 16 127 191 48 1.3 4 4.500 500 7950 0 -0.13 0.34 5.80 8.03 2.13 4.1 11-36' 2- 1/2 x 2 3/a 100 114.3 3450 35380 0 -3.2 28 147 204 54 1.9 4.250 450 6380 0 -0.13 0.35 5.55 7.79 2.13 3.7 108.0 m m 11-411' 2- 12 x 70 108.0 3100 28395 0 -3.2 29 141 198 54 1.7 41/2 5.000 450 8820 0 -0.13 0.25 6.13 9.43 2.13 5.5 1 ° -26' 2- 5/a x 3 1/a 120 127.0 3100 39250 0 -3.2 21 156 240 54 2.5 5 5.563 450 10935 0 -0.13 0.27 6.88 10.07 2.13 5.8 11-18' 2- 5/a x 3 1/a 125 141.3 3100 48660 0 -3.2 23 175 256 54 2.6 5.250 450 9735 0 -0.13 0.28 6.55 9.37 2.13 6.0 133.0 m m 11-21' 2- 16 x 82.5 133.0 3100 43325 0 -3.2 24 166 238 54 2.7 5.500 450 10665 0 -0.13 0.28 6.80 9.59 2.13 6.3 139.7 m m 1 ° -18' 2- 5/a x 3 1/a 139.7 3100 47460 0 -3.2 24 173 244 54 2.9 6.000 450 12735 0 -0.13 0.21 7.38 10.48 1.88 6.2 152.4 m m 11-12' 2- 5/a x 3 1/a 152.4 3100 56670 0 -3.2 18 187 266 48 2.8 6 6.625 450 15525 0 -0.13 0.23 8.00 11.07 2.13 7.0 1 ° -5' 2- 5/a x 3 1/a 150 168.3 3100 69085 0 -3.2 18 203 281 54 3.2 6.250 450 13800 0 -0.13 0.24 7.63 10.49 2.13 6.8 159.0 m m 1 ° -9' 2- 16 x 82.5 159.0 3100 61405 0 -3.2 20 194 266 54 3.1 8 8.625 450 26280 0 -0.13 0'18 10.34 13.97 2.13 12.4 0° -50' 2- 3/a x 41/4 200 219.1 3100 116945 0 -3.2 14 263 355 59 5.6 2 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 3/a - 3 V2"120 - 90 mm; 25% for 47100 mm and larger. 4 Number of bolts required equals number of housing segments. General Notes Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1' /2 times the figures shown. 06.05 1470 Rev 0 Updated 09/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 ictaulic® victaulic.com I Couplings I Flexible I Style 75 1 Publication 06.05 Installation Note Reference should always be made tothe 1 -100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications. All products the product you are installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation /assembly instructions. products for complete installation and assembly data, and are available in PDF format Victaulic reserves the right to change product specifications, designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic6 is a registered trademark of Victaulic Company. 06.05 1470 Rev 0 Updated 09/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 ictauhl R�111b1e� New from Reliable are high quality fire protection control Butterfly Valves in both Grooved End and Wafer Style options. These valves are UL, ULC listed and FM approved and are available in sizes from 2'/2' up to 8 ". They are supplied from stock with factory installed UL listed double tamper switch for indoor and outdoor use. Grooved End 2 -1/2" - 8" (65mm up to 200mm) Working Pressure and Temperature . Working Pressure 300 PSI (21.4Bars) Max. Test Pressure 600 PSI (42.8Bars) Max. Working Temperature 250 °F (120 °C) Grooved End(2 -112" Through 8 ") Tom„ ,� r�sr� G : DISC CLEARANCE OPWOY SURFACE THROUGH END OF DISC IN THE OPEN PQSMON SIZE A Component Material Body ASTM A -536 Nylon -11 Coated Disc ASTM A -536 EPOM Encapsulated Upper & Lower Stems AISI 420 -SS Housing ASTM A -536 Hand Wheel ASTM A -536 Flag indicator ASTM A -536 Shear Pin ASTM A -510 Segment Gear ASTM B -148 or B -584 Housing Gasket EPDM Grade E 0 -Rings (All) EPDM Grade E Grooved End(2 -112" Through 8 ") Tom„ ,� r�sr� G : DISC CLEARANCE OPWOY SURFACE THROUGH END OF DISC IN THE OPEN PQSMON SIZE A B C D E F G H 2 -1/2" 4.13 (105) 3.30 (85) 3.80 (96.4) 2.87(73.0) 5.31 (135) 5.04 (128) 5.04 (128) 3" 4.41 (112) 3.60 (92) 3.80 (96.4) 3.50 (88.9) 5.59 (142) 5.04 (128) 5.04 (128) 4" 5.71 (145) 4.30 (108) 4.54 (115.4) 4.50 (114.3) 6.89 (175) 5.04 (128) 5.04 (128) 6" 7.05 (179) 5.71 (145) 5.21 (132.4) 6.63 (168.3) 8.23 (209) 8.66 (220) 8.66 (220) 0.28 (7.10) 8" 8.03 (204) 6.70 (170) 5.80 (147.4) 8.63 (219.1) 9.21 (234) 8.66 (220) 8.66 (220) 0.95 (24.2) @ @ FM LISTED LISTED °P"'MVM Wiring Diagram SUPERVISORY TAMPER SWITCH CIRCUITS (VALVE FULLY OPEN) ��e�",�°""I� OPEN (RED) S1 aeeEV [YELLOW! cam eD � ENO OR L1HE AE 93T ANCE LbJON 1L►IrITE1 DR NE %T OEYICE GFX= ACTUATOR LASE GROUND ePeN IarreNUei NC V9LlA�E Srl SWFCE L ctveeo [sLUq � cvM Nv Cb11eON 1eLAbr1 AIAGLULRY eIaNAL GeVICe teeLL vn F1var1F Butterfly Test Data GROOVED END Flow chafacterfstics M so CD 60 73 09 ww���ww ■w.r.� rMENOW � = =Wwt- A1•A1� www�wlwel }•sA!■■■r If�R ■ ■ ■I.fa��1� �Iltrrrn■r��� C2 011 5 6 789 WAFER TYPE Flow characteristics 100 ISO 200 4' 6' 81 114 f85 219 168 1 2 3 4 5 6 7 89 2 t0 rk- lmYht DN 65 80 100 150 1 200 Size -11x" 3' 4' 6" 8" Kv 210 330 610 1500 2740 iv 240 385 712 1750 3150 Lv - myhpyr auosy relre a ume s��di+d 1ondNiom E70'C, I G.r } Kr - GPM M 1 n dim""W I Pn14u14 —1 robe al .lan&W [-Mlles 160'F, 14.7 PO Flow coefficient : Kv .- MUh— acrossw xsane aaldad —Wa WC WI ON tmml I SIIEfin} I OR 1 30' 1 40" 1 SO" 1 60' 1 70" 1 80" 1 90' 65 2112" 73 12 27.4 531 96 138 t5fi lfi3 65 2112' 76 12 27.4 53.1 96 138 156 163 80 1 3" 89 18.9 1 39A 78.9 1 144 210 1 243 749 100 4' 114 30 65.1 129 226 377 488 514 150 6" 165 64 184 369 634 964 1196 1286 150 6" 168 84 184 364 634 964 1196 1286 200 8" 219 165 339 677 1230 2002 2850 3729 CV = 6 KV KV= 0 P 0= 31.6KV O - flow 4P = pressureless P1 = density in n1'th In bar in k9im' Flow Coefficients The Plow coefficient KV is Ilhe Follow in m'th of water, at an average temperature of 20'C, crossing the value with creating a headloss of 1 bar. The relation between Cy and KV is; Cv= B Kv 100 90 so 70 eo 50 60 30 20 i0 a Cv V5OrscAngfe Ax Cu0— U 10 20 00 40 so 60 70 00 90 Angle of Opening t- tqC17 Model DPV -1 Dry 2 -112 thru 6 Inch 250 psi (17,2 bar) General Description The TYCO Model DPV -1 Dry Pipe Valves are differential valves used to automatically control the flow of water into dry pipe fire protection sprinkler systems upon operation of one or more automatic sprinklers. The DPV -1 also provides for actuation of fire alarms upon system operation. The Model DPV -1 features are as follows: • External reset. • 250 psi (17,2 bar) pressure rating. • Unique offset single clapper design enabling a simple compact valve to minimize installation labor. • Ductile iron construction to ensure a lightweight valve to minimize shipping cost. • A variety of inlet and outlet connections. • Compact, Pre - Trimmed, and Semi - Assembled, easy to operate valve trim. • Simple reset procedure through the elimination of priming water. Dry pipe sprinkler systems are used in unheated warehouses, parking garages, store windows, attic spaces, loading docks, and other areas exposed to freezing tempera- tures, where water filled pipe cannot be utilized. When set for service, the dry pipe sprinkler system is pressur- ized with air (or nitrogen). The loss of pressure through an operated automatic sprinkler in response to heat from a fire permits the DPV -1 Dry Pipe Valve to open and allow a flow of water into the sprinkler system piping. Table B establishes the minimum required system air pressure that includes a safety factor to help prevent false operations that might occur due to water supply fluctuations. Worldwide I www.tyco - fire.com Contacts Pipe Valve, External Resetting (DN65 thru DN150) 4„ NOTICE The Model DPV -1 Dry Pipe Valves described herein must be installed and maintained in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating condition. The installing contractor or manufac- turer should be contacted with any questions Page 1 of 20 MARCH 2013 TFP1020 Available End Connections and Sizes End Connection Nominal Valve Size 2 -112 Inch (DN65) 3 Inch (DN80) 4 Inch (DN100) 6 Inch (DN150) Flange x Flange N/A N/A Flange x Groove N/A N/A Groove x Groove 0 Available N/A Not Available NOTICE The Model DPV -1 Dry Pipe Valves described herein must be installed and maintained in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating condition. The installing contractor or manufac- turer should be contacted with any questions Page 1 of 20 MARCH 2013 TFP1020 TFP1020 Page 2 of 20 NO. DESCRIPTION QTY. REF. 1 Valve Body ....... 1 NR 2 Air and Water Seat ............ 1 NR 3 Handhole Cover ... 1 NR 4 Handhole Cover 0-11 Gasket .......... 1 See (b) 5 1/2 -13 UNC x 1 " Hex — 12 Head Cap Screw: 2-112 & 3 Inch 6 Valves ........... 5 CH ® 13 4 Inch Valve ...... 6 CH 7 6 Clapper.......... 1 See (a) CLAPPER RESET 7 Clapper Facing .... 1 See (a) or (b) ASSEMBLY 14 PLUNGER 8 Clapper Facing 8 0� PARTS Retaining Plate .... 1 See (a) 15,18 9 2 -112 and 3 Inch Valves: \� 9 1/4" x 3/8" Long #10 -32 Shoulder 16 Screw ........... 5 See (a) 4 Inch Valve: 17 1/4 -20 UNC x 112" Socket Head Cap Screw ........... 7 See (a) 10 Clapper Hinge Pin .. 1 See (a) 11 Reset Knob ...... 1 See (c) 0 12 Reset Spring ..... 1 See (c) 13 Reset Bushing .... 1 See (c) 14 Reset Bushing O -Ring 1 See b or c 15 Reset Plunger O -Ring .......... 1 See (b) or (c) 16 Reset Plunger..... 1 See (c) 17 Reset Latch Subassembly ..... 1 See (c) 18 Dow Corning FS3452 1 Flourosilicone 4 Grease, 1.5 g ..... 1 See (b) or (c) 1[17 2 3 5 NR: Not Replaceable CH: Common Hardware REPLACEMENT PARTS NO. DESCRIPTION P/N (a) Clapper Assembly Includes Items 6 -10: 2 -112 & 3 Inch Valves .. 92- 309 -2 -203 4 Inch Valve ......... 92- 309 -2 -403 (b) Repair Parts Kit Includes Items 4, 7, 14, 15, & 18: 2 -112 & 3 Inch Valves .. 92- 309 -1 -204 4 Inch Valve ......... 92- 309 -1 -404 (c) Reset Plunger Parts Kit Includes Items 11-18.. 92- 310 -1 -405 FIGURE 1 - PART 1 OF 2 MODEL DPV -1 DRY PIPE VALVE "- :—D 4 INCH (DN6&j DN89, DN100) ASSEMBLIES NO. DESCRIPTION QTY. REP. PART 1 Valve Body ....... 1 NR 2 Air and Water 5/8 -11 UNC x 1 "... 6 CH Seat ............ 1 NR 3 Water Seal 10 Clapper Facing .... 1 Se (a) or (b) O -Ring .......... 1 NR 4 Air Seal O- Ring .... 1 NR TFP1020 Page 3 of 20 oc e ea ap Screw 1/4 -20 UNC x 1/ '.. 9 See (a) ' 0-14 13 Clapper Hinge n.. 1 See (a) 14 Reset Knob .... 1 See (c) 15 Reset Spri ..... 1 See (c) 9 15 16 Reset Bu ing .... 1 See (c) \ / 17 Reset shing /— ® 16 O -Ri ........... 1 See (b) or (c) 10 18 Re t Plunger CLAPPER RESET O ing........... 1 See (b) or (c) ASSEMBLY 17 PLUNGER e 19 eset Plunger..... 1 See (c) a _ / -11 Q� PARTS 2 Reset Latch 18,21 Subassembly ..... 1 See (c) e12 21 Dow Corning FS3452 Flourosilicone 19 Grease, 1.5 g ..... 1 See (b) or (c) NR: Not Replaceable 2 0 CH: Common Hardware NO. DESCRIPTION QTY. REP. PART 8 Hex Head Cap Screw 5/8 -11 UNC x 1 "... 6 CH DESCRIPTION 9 Clapper .......... 1 See 10 Clapper Facing .... 1 Se (a) or (b) Clapper Assembly 11 Clapper Facing Retaining Plate .... 12 S I<tH dC 1 ee (a) oc e ea ap Screw 1/4 -20 UNC x 1/ '.. 9 See (a) ' 0-14 13 Clapper Hinge n.. 1 See (a) 14 Reset Knob .... 1 See (c) 15 Reset Spri ..... 1 See (c) 9 15 16 Reset Bu ing .... 1 See (c) \ / 17 Reset shing /— ® 16 O -Ri ........... 1 See (b) or (c) 10 18 Re t Plunger CLAPPER RESET O ing........... 1 See (b) or (c) ASSEMBLY 17 PLUNGER e 19 eset Plunger..... 1 See (c) a _ / -11 Q� PARTS 2 Reset Latch 18,21 Subassembly ..... 1 See (c) e12 21 Dow Corning FS3452 Flourosilicone 19 Grease, 1.5 g ..... 1 See (b) or (c) NR: Not Replaceable 2 0 CH: Common Hardware 13 J J a J a FIGURE 1 - PART 2 OF 2 MODEL DPV -1 DRY PIPE VALVE 6 INCH (DN150) ASSEMBLY REPLACEMENT PARTS NO. DESCRIPTION P/N (a) Clapper Assembly Includes Items 9 -13 ... 92- 309 -2 -603 (b) Repair Parts Kit / Includes Items 7, 10, 17, 18, 21 ...... 92- 309 -1 -604 (c) Reset Plunger Parts Kit IIncludes 2 Items 14 -21 .. 92- 310 -1 -405 13 J J a J a FIGURE 1 - PART 2 OF 2 MODEL DPV -1 DRY PIPE VALVE 6 INCH (DN150) ASSEMBLY TFP1O2O Page 4 of 20 Technical Data Approvals UL and C -UL Listed. FM Approved. NYC under MEA 172 -02 -E (4 and 6 inch). Dry Pipe Valve The TYCO Model DPV -1 Dry Pipe Valves are for vertical installations (flow going up), and they are rated for use at a maximum service pressure of 250 psi (17,2 bar). The Valve dimensions are shown in Figure 7. Flanged connections are available and drilled per ANSI, ISO, AS, and JIS spec- ifications (Ref. Table A). The grooved outlet connections, as applicable, are cut in accordance with standard groove specifications for steel pipe. They are suitable for use with grooved end pipe couplings that are listed or approved for fire protection system service. Available combinations of inlet and outlet connections are detailed in the Ordering Procedure section. They are also noted in the "Available End Connection and Sizes" table located on Page 1. Threaded port connections of valves having flanges drilled to ANSI, AS, or JIS specifications are NPT threaded per ANSI Standard B1.20.1. Threaded port connections of valves having flanges drilled to ISO are available either threaded per ISO 7 -1 or NPT threaded per ANSI Standard B1.20.1. Valves with NPT threaded ports will readily accept the trim arrangements detailed in Parts 2 and 3 of Figures 4, 5, and 6. Components of the DPV -1 Valves are shown in Figure 1. The Body and Handhole Cover are ductile iron. The Handhole Cover Gasket is neoprene, and the Clapper Facing is EPDM. The Air /Water Seat Ring is brass, the Clapper is bronze or aluminum bronze, and both the Clapper Retaining Plate and Latch are bronze. The Hinge Pin is aluminum bronze, and the fasteners for the Handhole Cover are carbon steel. Valve Trim Installation dimensions are given in Figure 7, and the Valve Trim and Pre - Trimmed Valve Assemblies are illustrated in Figures 4, 5, and 6. The Valve Trim and Pre - Trimmed Valve forms a part of the laboratory listings and approval of the DPV -1 Valve and is necessary for the proper operation of the DPV -1 Valve. Each package of trim and pre- trimmed includes the following items: • Water Supply Pressure Gauge • System Air Pressure Gauge • Air Supply Connections • Main Drain Valve • Low Body Drain Valve • Alarm Test Valve • Automatic Drain Valve • Drip Funnel • Connections For Optional Quick Opening Device (Accelerator) Also included in the Pre - Trimmed Valve Assembly, which can be ordered sepa- rately for the Valve Trim, includes the following items: • Model BFV -N butterfly vlave • Figure 577 grooved coupling • PS10 -2 waterflow alarm switch • PS40 -2 low air pressure alarm switch Note: When the system pressure is greater than 175 psi (12,1 bar), provision is to be made to replace the standard order 300 psi (20,7 bar) Water Pressure gauge with a separately ordered 600 psi (41,4 bar) Water Pressure Gauge. Air Supply Table B shows the system air pressure requirements as a function of the water supply pressure. The air (or nitrogen) pressure in the sprinkler system is recommended to be auto- matically maintained by using one of the following pressure maintenance devices, as appropriate: • Model AMD -1 Air Maintenance Device (pressure reducing type). • Model AMD -2 Air Maintenance Device (compressor control type). • Model AMD -3 Nitrogen Maintenance Device (high pressure reducing type). The Pressure Relief Valve provided with the valve trim is factory set to relieve at a pressure of approximately 45 psi (3,1 bar). If the normal system air pressure is less than or exceeds 40 psi (2,8 bar), then the pressure Relief Valve must be reset to relieve at a pressure that is in accordance with the authority having jurisdiction. Quick Opening Device As an option, the Model DPV -1 Dry Pipe Valve may be equipped with the VIZOR Electronic Dry Pipe Valve Accelerator (4 and 6 inch sizes) as detailed in Technical Data Sheet TFP1105 or the Model ACC -1 Mechanical Dry Pipe Valve Accelerator (2 -1/2, 3, 4, and 6 inch sizes) as detailed in Technical Data Sheet TFP1112. The VIZOR or the ACC -1 is used to reduce the time to valve actuation following the operation of one or more automatic sprinklers. In some cases the use of a quick opening device such as the VIZOR or the ACC -1 may be required to meet the requirements of the National Fire Protection Association to meet water delivery times. Operation The TYCO Model DPV -1 Dry Pipe Valve is a differential type valve that utilizes a substantially lower system (air or nitrogen) pressure than the supply (water) pressure, to maintain the set position shown in Figure 3A. The differ- ential nature of the DPV -1 is based on the area difference between the air seat and the water seat in combination with the ratio of the radial difference from the Hinge Pin to the center of the Water Seat and the Hinge Pin to the center of the Air Seat. The difference is such that 1 psi (0,07 bar) of system air pressure can hold approximately 5.5 psi (0,38 bar) of water supply pressure. Table B establishes the minimum required system air pressure that includes a safety factor to help prevent false operations that occur due to water supply fluctuations. The Intermediate Chamber of the DPV -1 is formed by the area between the Air Seat and Water Seat as shown in Figure 313. The Intermediate Chamber normally remains at atmospheric pressure through the Alarm Port connection and the valve trim to the normally open Automatic Drain Valve (Fig. 4, 5, or 6). Having the Intermediate Chamber, Figure 313, open to atmo- sphere is critical to the DPV -1 Valve remaining set, otherwise the full resulting pressure of the system air pressure on top of the Clapper Assembly cannot be realized. For example, and assuming a water supply pressure of 100 psi (6,9 bar), if the system air pressure is 25 psi (1,7 bar) and there was 15 psi (1,0 bar) pressure trapped in the Intermediate Chamber, the resulting pressure across the top of the Clapper would only be 10 psi (0,7 bar). This pressure would be insufficient to hold the Clapper Assembly closed against a water supply pressure of 100 psi (6,9 bar). It is for this reason that the plunger of the Automatic Drain Valve must be depressed during several of the resetting steps, as well as during inspections, making certain that the Automatic Drain Valve is open. When one or more automatic sprin- klers operate in response to a fire, air pressure within the system piping is relieved through the open sprin- klers. When the air pressure is suffi- ciently reduced, the water pressure overcomes the differential holding the Clapper Assembly closed and the Clapper Assembly swings clear of the water seat, as shown in Figure 3C, This action permits water flow into the system piping and subsequently to be discharged from any open sprinklers. Also, with the Clapper Assembly open, the intermediate chamber is pres- surized and water flows through the alarm port (Ref. Figure 313) at the rear of the DPV -1 Valve to actuate system water flow alarms. The flow from the alarm port is also sufficient to close the otherwise normally open Automatic Drain Valve in the valve trim. After a valve actuation and upon sub- sequent closing of a system main control valve to stop water flow, the Clapper Assembly will latch open as shown in Figure 3D. Latching open of Continued on page 16 TFP1020 Page 5 of 20 Maximum Water Supply Pressure, psi System Air Pressure Range, psi 20 10 60 15-23 80 20-28 100 25-33 120 30-38 145 35-43 165 40-48 185 45-53 205 50-58 225 55-63 250 60-68 TABLE B SYSTEM AIR PRESSURE REQUIREMENTS • rr rr rrr rrr rrr rrr rrrr 'r r.r • r MEMO ::: 111°1111 : : : : :I :I : : : :A : : : : : : : :.: r r ■■ Onnn ■■Onmm�mnnnl■I�nn■■nnnn■■■11■■ == ='e' -- r r "-- 2222222 : " ■ " ■eeeeeee '�E : "eeeeeev� :eeeeeee� : " ■ " ■: : : : : : : : : : :� : : : : : : : : :: •. :; : : : : : : : :; : : : :: :...1221:: MMI.......... .......... ■......... X11..0.01 ■.. • ■ ■ ■ ■nnn ■ ■ ■ ■ ■■■■ cnn ■ ■ ■■n,n ■ ■ ■■ ■nun ■ ■ ■ ■■ •••nnnu••m Isunn••n�1n•••nnnu••n • r 222•oon222.1 _ Isnnnunr�nn222v�nnu22n ■ ■ ■ ■ ■ ■ ■ ■ ■.. ■■ r,.m IF ■.■■■■■..■■■■■ mmmmmllmmoom ■ ■ ■ ■ ■ ■ ■ ■ ■. ■■ / ■.. 111 ■■ I ■mono ■ ■■■ ■ ■ ■■ ° 1 1 ■ ■■ ■■11111■ -�� I111 Irl■■■ I ■■ mono 111 ■ ■ ■•1 • r ����111111■ �� I,111 1;11�� _ 7���111111����1 221::::::: •, 21:::::::221:: 1 1: • • .:: .;2222: .;= .9::• Mono■ - ■■■ �.■■ r.n■■■■■■■■..■■■■■ r ■■■■■ on■ rnu■. ,■...■■■■■■■..■■■■■ 1 1 • ■■on■ _.■■■■ r�nun ran■■■■■■■■..■■■■■ r r . ME M-02. _ == r r ■on■nn ■■vunn nnunn o n n n ■onnm ■■■■■ • ■■ ■nr�nn■■nnnnun ■mnonnn■■onnn■■o■ ■• •nnnu••nnnunrnnn••nnn•••nnnu••n • r 222 •nnn22ra1nnunnnnunnuu22•nnn222n : ......... . . . . . . . . . . . . . . . . . . . . . . . ■■.■■■■■■.......... r... ............................... ■.,■■■■■■■..■■..■■..... ............................... ■uonnn ■■■■■ nnu nor 11111 ■■ n n.u■■■■■■■.. ■■■■■ r r • . ■ ■ ■■■■■r. ■ ■ ■ ■■■■rnnnunn ■■non ■ ■ ■ ■■■■■.. ■ ■ ■ ■■ n••mm�•••nnnunnnnunnau••nnnu••n r ����111ri11����11/ 1111111111111��111111����111111����1 of rr rr rr rr rrr rrr rrr •• •• •- TFP1020 Page 6 of 20 1" NPT AIR SUPPLY PORT 1/2" NPT WATER SUPPLY PRESSURE & ALARM TEST PORT CLAPPER ASSEMBLY LATCHED, OPEN 3/4" NPT LOW BODY DRAIN PORT AIR PRESSURE TO SYSTEM CLAPPER CLAPPER ASSEMBLY ASSEMBLY IN SET FULLY OPEN POSITION CLAPPER LATCI PIVOTS TO ALLO WATERFLOW TO SYSTEM t ° CLAPPER ASSEMBLY =2 ° TO FULLY OPEN i -T -T- 3/4" NPT ALARM -T -T- ( PORT OPEN TO (`7.z ATMOSPHERE ALARM PORT V „I x WATERFLOW CLAPPER i TO ALARM ASSEMBLY FROM WATER SUPPLY DRAIN FROM SYSTEM Z - �` i WATER SUPPLY SHUTOFF DRAIN POSITION FROM AIR WATER SUPPLY SEAT FIGURE 3C WATER ALARM OPERATED POSITION SEAT I „ PORT \ DRAIN FROM x; SYSTEM VALVE INTERMEDIATE COMPLETE WATERWAY CHAMBER FIGURE 3113 SET POSITION INTERMEDIATE CHAMBER RESET ASSEMBLY CLAPPER LATCH PIVOTS TO r CLAPPER UNLATCH / LATCH CLAPPER ASSEMBLY - := - MAIN DRAIN PORT: x 2" NPT (4 INCH VALVE) '.z. 'DN40 FOR VALVES WITH ISO THREADED PORTS FIGURE 3 - PART 1 OF 2 MODEL DPV -1 DRY PIPE VALVES ' "' ' AND 4 INCH (DN65, DN80, AND DN100) SET AND OPEN POSITIONS WATER SUPPLY SHUTOFF RESET POSITION PUSH HERE TO RESET VALVE RESET KNOB 'PER MBLY ATED 1 AIR F CL AS, Ir PO AIR PRESSURE TO SYSTEM t CLAPPER ASSEMBLY LATCHED OPEN 3/4" NPT LOW BODY DRAIN PORT 2" NPT MAIN DRAIN PORT FROM WATER SUPPLY SET POSITION WATER i S EAT DRAIN FROM SYSTEM INTERMEDIATE ICHAMBER WATER SUPPLY SHUTOFF CLAPPER ASSEMBLY FULLY OPEN LAPPER LATCH JOTS TO ALLOW kPPER ASSEMBLY O FULLY OPEN 3/4" NPT ALARM PORT OPEN TO ATMOSPHERE 1/2" NPT WATER SUPPLY PRESSURE & ALARM TEST PORT ER WATERFLOW TO SYSTEM t SEAT FROM JWATER SUPPLY ALARM FIGURE 3C PORT OPERATED POSITION DRAIN FROM SYSTEM COMPLETE VALVE WATERWAY It FI URE 3B S POSITION TERMEDIATE CHAMBER RESET ASSEMBLY CLAPPER LATCH PIVOTS TO UNLATCH CLAPPER ASSEMBLY CLAPPER LATCH TFP1020 Page 7 of 20 ALARM PORT WATERFLOW TO ALARM PUSH HERE Tn RESET (E RESET KNOB DRAIN POSITION FIGURE 3 - PART 2 OF 2 MODEL DPV -1 DRY PIPE VALVES 6 INCH (DN150) SET AND OPEN POSITIONS WATER SUPPLY SHUTOFF RESET POSITION 'ER IBLY TED TFP1020 Page 8 of 20 NOTES: 1. SEE FIGURE 4 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS AND COMPONENT PART NUMBERS. 2. TRIM SHOWN FULLY ASSEMBLED; COMPONENTS SUCH AS GAUGES AND SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. 1 INCH NPT SYSTEM CONNECTION CONNECTION AIR SUPPLY FOR OPTIONAL ALPHABETICAL ORDER. FOR LOCAL PRESSURE SPRINKLER ®GAUGE 2 -112 INCH (DN65) I 3. ROUTE 1/4" BING TO DRIP or3INCH (DN80) 112 INCH NPT CONNECTION MODEL DPV -1 FOR SYSTEM AIR SUPPLY PRESSURE DRAIN VALVE DRY PIPE VALVE (GxG ONL:� MAIN / ALARM TEST VALVE DRAIN VALVE C (NORMALLY e (NORMALLY CLOSED) SYSTEM CLOSED) WATER 3/4 INCH NPT SYSTEM SUPPLY CONNECTION SHUT -OFF 1 -1/4 INCH NPT PRESSURE TO DRAIN VALVE CONNECTION GAUGE LOW BODY (NORMALLY TO DRAIN DRAIN VALVE OPEN) AIR SUPPLY CONTROL VALVE (NORMALLY OPEN) 112 INCH NPT CONNECTION FOR SYSTEM AIR SUPPLY LOW AIR PRESSURE ALARM SWIT SYSTEM AIR SUPPLY CONTROL VALVE (NORMALLY OPEN) WATERFLOW PRESSURE ALARM SWITCH GROOVED COUPLING 112 INCH NPT CONNECTION FOR OPTIONAL ACCELERATOR AUTOMATIC DRAIN VALVE (NORMALLY 1 -1/4 INCH NPT \ CLOSED) CONNECTION DRIP TO DRAIN FUNNEL FIGURE 4 - PART 1 OF 3 2 -112 AND 3 INCH (DN65 AND DN80) MODEL DPV -1 DRY PIPE VALVE PRE - TRIMMED ASSEMBLY 112 INCH NPT CONNECTION Gj FOR WATERFLOW PRESSURE ALARM SWITCH 1 -1/4 INCH NPT CONNECTION TO DRAIN 1 INCH NPT CONNECTION FOR LOCAL SPRINKLER ALARM TEST VALVE (NORMALLY CLOSED) 112 INCH NPT 112 INCH NPT NOTES: CONNECTION CONNECTION 1. INSTALL TRIM ASSEMBLIES FOR OPTIONAL FOR OPTIONAL ALPHABETICAL ORDER. ACCELERATOR AUTOMATIC AIR PRESSURE SWITCH 2. SEE FIGURE 3 FOR LVE PORT DRAIN VALVE IDENTIFICATIO I 3. ROUTE 1/4" BING TO DRIP H FUNNE SYSTEM AIR SUPPLY MAIN ® PRESSURE DRAIN VALVE D GAUG A (NORMALLY E \ CLOSED) i DRIP FUNNEL 1 -1/4 INCH NPT CONNECTION 2 -112 INCH (DN65) TO DRAIN C or 3 INCH (DN80) MODEL DPV -1 DRY PIPE VALVE (GxG ONLY) F B LOW BODY DRAIN VALVE SYSTEM (NORMALLY WATER SUPPLY 3/4 INCH NPT CLOSED) PRESSURE CONNECTION GAUGE TO DRAIN FIGURE 4 - PART 2 OF 3 2 -112 AND 3 INCH (DN65 AND DN80) MODEL DPV -1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI- ASSEMBLED TRIM NO. DESCRIPTION QTY. P/N 1 250 psi/ 1750 kPa Air Pressure 1 92- 032 -1 -002 Gauge ........... 1 92- 343 -1 -012 2 300 psi/ 2000 kPa 1 CH Water Pressure 2 CH Gauge ........... 1 92- 343 -1 -005 3 1/4" Gauge Test 1 CH Valve ............ 2 46- 005 -1 -002 4 Model AD -1 . 1 CH Automatic 1 CH Drain Valve ....... 1 52- 793 -2 -004 5 1/4" Pressure 1 CH Relief Valve ....... 1 92- 343 -1 -020 6 112" Ball Valve .... 2 46- 050 -1 -004 7 3/4" Angle Valve ... 1 46- 048 -1 -005 8 1 -1/4" Angle Valve . 1 46- 048 -1 -007 9 112" Swing 1 CH Check Valve ...... 2 46- 049 -1 -004 10 Drip Funnel 2 CH Connector ........ 1 92- 211 -1 -005 11 Drip Funnel 1 CH Bracket .......... 1 92- 211 -1 -003 12 Drip Funnel ....... 1 92- 343 -1 -007 20 NO. DESCRIPTION QTY. P/N 13 3/32" Vent Fitting ........... 1 92- 032 -1 -002 14 1/4" Tube, 18' Long ......... 1 CH 15 1/4" Plug ......... 2 CH 16 112" Plug ......... 2 CH 17 1 " Plug .......... 1 CH 18 112" Union........ 1 CH 19 112" x 1/4" Reducing . 1 CH Bushing .........1 1 CH 20 112" 90° Elbow .... 3 CH 21 3/4" 90° Elbow .... 1 CH 22 1 -1/4" 90° Elbow... 1 CH 23 112" Cross........ 2 CH 24 112" x 112" x 1/4" CH Reducing Tee ..... 1 CH 25 112" Tee ......... 1 CH 26 112" x 1/4" x 112" Butterfly Valve, Reducing Tee ..... 2 CH 27 112" x 112" x 3/4" 5930OF025N 3 "(DN80) ........ Reducing Tee ..... 1 CH 45 �16 i 44-4 25� 31� 18--- 31- 26 13 (GREEN TINT) 33 g 16 31 27 en 15 3 2 -112 INCH (DN65) or 3 INCH (DN80) MODEL DPV -1 DRY PIPE VALVE (GxG ONLY) TFP1020 Page 9 of 20 NO. DESZed PTION QTY. P/N 281 "x1/2" Redg Tee ..... 1 CH 29 Not d PIPE NIPS: 30 1/4" " ......... 2 31 112" lose ...... 4 H 32 112" 1/2 "...... 8 CH 33 112" " ......... CH 34 1/2" 1/2 ".... . 1 CH 35 1/2" " ......... 1 CH 36 3/4" lose . .... 1 CH 37 3/4" 1/2 "...... 1 CH 38 3/4" -1/ ' ...... 1 CH 39 1 " x ........ 1 CH 40 1 -1/Close ....1 CH 41 1 -1/ 4 "........ 1 CH COM ONENTS INCLUDED ONLY IN PR - TRIMMED VALVE ASSEMBLIES: Model BFV -N Butterfly Valve, 2 -112" (DN65) ..... 1 5930OF025N 3 "(DN80) ........ 1 5930OF03ON 43 Figure 577 Coupling, 2 -112" (DN65) ..... 1 57725ACP 3" (DN80) ........ 1 57730ACP 44 Waterflow Pressure Alarm Switch, Model PS10- 2..... 1 25710 45 Low Air Pressure Alarm Switch, Model PS40- 2..... 1 25730 LOCATION 32 23 FOR OPTIONAL 10 36 41 8 ELECTRICALLY SUPERVISED 72 22 N.O. ALARM 20 1 40 CONTROL 11 1 VALVE 1 12 37 NOTES: 1' 14 43 1. SEE FIGURE 3 FOR VALVE 21 PORT IDENTIFICATION. 38 1 7 42 2. ROUTE 1/4" TUBING, ITEM 14, 31 TO DRIP FUNNEL, ITEM 12. 6 3. ALL FITTINGS AND NIPPLES 32 35 ARE GALVANIZED. 26 2 4. CH: COMMON HARDWARE 30 5. ITEMS 42 -45 INCLUDED 3 15 ONLY IN PRE - TRIMMED VALVE ASSEMBLIES AS APPLICABLE; OTHERWISE SEPARATELY ORDERED. FIGURE 4 - PART 3 OF 3 2 -112 AND 3 INCH (DN65 AND DN80) MODEL DPV -1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFP1020 Page 10 of 20 1. SEE FIGURE 5 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS AND COMPONENT PART NUMBERS. 2. TRIM SHOWN FULLY ASSEMBLED; COMPONENTS SUCH AS GAUGES AND SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. 112 INCH NPT CONNECTION FOR SYSTEM AIR SUPPLY 1 INCH NPT CONNECTION FORLOCAL - SPRINKLER 3/4 INCH NPT CONNECTION TO DRAIN ALARM ' TEST VALVE (NORMALLY CLOSED) LOW BODY SYSTEM DRAIN VALVE WATER (NORMALLY SUPPLY CLOSED) PRESSURE GAUGE SYSTEM AIR SUPPLY PRESSURE 4 INCH (DN100) MODEL DPV -1 DRY PIPE VALVE (FxG SHOWN) FLANGE ADAPTER OR GROOVED COUPLING MAIN DRAIN VALVE (NORMALLY CLOSED) SYSTEM SHUT -OFF VALVE (NORMALLY OPEN) 2 INCH NPT CONNECTION TO DRAIN LOW AIR PRESSURE ALARM SWITCH SYSTEM CONTROL AIR SUPPLY VALVE (NORMALLY / OPEN) 3/4 INCH NPT CONNECTION FOR WATER MOTOR ALARM WATERFLOW PRESSURE ALARM 112 INCH NPT SWITCH CONNECTION FOR OPTIONAL ACCELERATOR AUTOMATIC DRAIN VALVE 1 -1/4 INCH NPT \ CONNECTION DRIP TO DRAIN FUNNEL FIGURE 5 - PART 1 OF 3 4 INCH (DN100) MODEL DPV -1 DRY PIPE VALVE PRE - TRIMMED ASSEMBLY l 112 INCH NPT AIR SUPPLY CONNECTION CONTROL VALVE 1 FOR OPTIONAL (NORMALLY ACCELERATOR OPEN) 112 INCH NPT MAIN CONNECTION SYSTEM DRAIN VALVE 0 1/2 INCH NPT AUTOMATIC AIR SUPPLY .� CONNECTION DRAIN VALVE FOR OPTIONAL PRESSURE (NORMALLY AIR PRESSURE CLOSED) FOR WATERFLOW \ SWITCH GAUGE SLOPE PRESSURE ALARM DOWN SWITCH \ D I 3/4 INCH NPT \ \ CONNECTION FOR WATER A MOTOR ALARM \ i \ 112 INCH NPT �/ 2 INCH NPT CONNECTION CONNECTION FOR SYSTEM y I \ TO DRAIN AIR SUPPLY C I 0 4 INCH (DN100) ALARM / 01� MODEL DPV -1 TEST VALVE DRY PIPE VALVE ,, (NORMALLY CLOSED) 3/4 \ 1 INCH NPT NOTES: (FxG SHOWN) INCH NPT FOR CONNECTION 1. INSTALL TRIM ASSEMBLIES IN SYSTEM CONNECTION FOR LOCAL ALPHABETICAL ORDER. WATER SUPPLY SPRINKLER PRESSURE TO DRAIN 2. SEE FIGURE 3 FOR VALVE PORT GAUGE LOW BODY IDENTIFICATION. DRIP DRAIN VALVE 3. ROUTE 1/4" TUBING TO DRIP FUNNEL. FUNNEL 1 -1/4 INCH NPT (NORMALLY 4. SLOPE ASSEMBLY B DOWN TOWARD CONNECTION CLOSED) BACK OF VALVE TO FACILITATE TO DRAIN SUFFICIENT LOW BODY DRAINAGE. FIGURE 5 - PART 2 OF 3 4 INCH (DN100) MODEL DPV -1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI- ASSEMBLED TRIM 19 LOCATION FOR OPTIONAL ELECTRICALLY SUPERVISED N.O. ALARM 41 CONTROL VALVE \ 39 40 30 39 10 42 9 7 20 8 �1' I Y 37 2 22 28 3 35 32 17 NO. DESCRIPTION QTY. \ 30 PORT IDENTIFICATION. 24 Air Pressure 34 CH Gauge ........... 33 92- 343 -1 -012 2 300 psi/ 2000 kPa 1 CH 25 1 CH Gauge ........... 1 92- 343 -1 -005 33 1 CH Valve ............ 40 30 39 10 42 9 7 20 8 �1' I Y 37 2 22 28 3 35 32 17 NO. DESCRIPTION QTY. P/N 1 250 psi/ 1750 kPa PORT IDENTIFICATION. 2. Air Pressure CH CH Gauge ........... 1 92- 343 -1 -012 2 300 psi/ 2000 kPa 1 CH Water Pressure 1 CH Gauge ........... 1 92- 343 -1 -005 3 1/4" Gauge Test 1 CH Valve ............ 2 46- 005 -1 -002 4 1/4" Pressure ONLY IN PRE - TRIMMED 4" (DN100) ....... 1 Relief Valve ....... 1 92- 343 -1 -020 5 112" Angle Valve ... 1 46- 048 -1 -004 6 Model AD -1 1 CH Automatic DRY PIPE VALVE Model PS40- 2..... 1 Drain Valve ....... 1 52- 793 -2 -004 7 112" Ball Valve .... 1 46- 050 -1 -004 8 112" Swing 1 CH Check Valve ...... 1 46- 049 -1 -004 9 3/4" Angle Valve ... 1 46- 048 -1 -005 10 3/4" Swing 2 CH Check Valve ...... 1 46- 049 -1 -005 11 2" Angle Valve .... 1 46- 048 -1 -009 12 Drip Funnel 1 CH Connector ........ 1 92- 211 -1 -005 13 Drip Funnel 1 CH Bracket .......... 1 92- 211 -1 -003 14 Drip Funnel ....... 1 92- 343 -1 -007 15 3/32" Vent Fitting ........... 1 92- 032 -1 -002 16 1/4" Tube, 24" Long ......... 1 CH 17 1/4" Plug ......... 2 CH 18 112" Plug ......... 2 CH 19 3/4" Plug......... 1 CH 20 1 " Plug .......... 1 CH NO. DESCRIPTION QTY. P/N 21 112" x 1/4" Reducing PORT IDENTIFICATION. 2. Bushing .........1 CH CH 22 112" Union........ 1 CH 23 3/4" Union........ 1 CH 24 112" 90° Elbow .... 1 CH 25 112" 45° Elbow .... 1 CH 26 112" Cross........ 1 CH 27 112" Tee ......... 2 CH 28 112" x 1/4" x 112" ONLY IN PRE - TRIMMED 4" (DN100) ....... 1 Reducing Tee ..... 2 CH 29 112" x 112" x 1/4" SEPARATELY ORDERED. Model PS10- 2..... 1 Reducing Tee ..... 1 CH 30 3/4" x 112" x 3/4" DRY PIPE VALVE Model PS40- 2..... 1 Reducing Tee ..... 3 CH 311 "x1 "x112" Reducing Tee ..... 1 CH PIPE NIPPLES: 32 1/4" x 3'.......... 2 CH 33 112" x Close ...... 2 CH 34 112" x 1- 112 "...... 7 CH 35 112" x 2" ......... 1 CH 36 112" x2- 1/2 "...... 1 CH 37 112" x 3" ......... 1 CH 38 112" x3- 1/2 "...... 1 CH 39 3/4" x Close ...... 2 CH 40 3/4" x 1- 112 "...... 2 CH TFP1020 Page 11 of 20 NOTES: 1. SEE FIGURE 3 FOR VALVE CH PORT IDENTIFICATION. 2. ROUTE 1/4" TUBING, ITEM 16, CH TO DRIP FUNNEL, ITEM 14. 3. SLOPE 3/4" ANGLE VALVE, 12 ITEM 9, DOWN TOWARD 14 BACK OF VALVE TO 5930OF04ON FACILITATE SUFFICIENT LOW BODY DRAINAGE. 4. ALL FITTINGS AND NIPPLES ARE GALVANIZED. 5. CH: COMMON HARDWARE 13 6. ITEMS 45 -48 INCLUDED ONLY IN PRE - TRIMMED 4" (DN100) ....... 1 VALVE ASSEMBLIES AS 47 Waterflow Pressure APPLICABLE; OTHERWISE Alarm Switch, SEPARATELY ORDERED. Model PS10- 2..... 1 4 INCH (DN100) 48 Low Air Pressure MODEL DPV -1 Alarm Switch, DRY PIPE VALVE Model PS40- 2..... 1 (FxG SHOWN) 46 44 45 11 NO. DESCRIPTION QTY. P/N 41 3/4" x 2" ... 1 CH 42 3/4" x 3" ......... 1 CH 431 "x4 "...........1 CH 44 2" x 4- 1/2 "........ 1 CH COMPONENTS INCLUDED ONLY IN PRE - TRIMMED VALVE ASSEMBLIES: 45 Model BFV -N Butterfly Valve, 4" (DN100) .. 1 5930OF04ON 46 Butterfy Valve Assembly Component: GxG DPV -1 Valves, Figure 577 Coupling, 4" (DN100) ....... 1 57740ACP FxF, FxG DPV -1 Valves, Figure 71 Flange Adapter, 4" (DN100) ....... 1 7140S 47 Waterflow Pressure Alarm Switch, Model PS10- 2..... 1 25710 48 Low Air Pressure Alarm Switch, Model PS40- 2..... 1 25730 FIGURE 5 - PART 3 OF 3 4 INCH (DN100) MODEL DPV -1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFP1020 Page 12 of 20 NOTES: 1. SEE FIGURE 6 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS AND COMPONENT PART NUMBERS. 2. TRIM SHOWN FULLY ASSEMBLED; COMPONENTS SUCH AS GAUGES AND SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. 112 INCH NPT CONNECTION FOR SYSTEM AIR SUPPLY 1 INCH NPT CONNECTION FOR LOCAL SPRINKLER DRIP FUNNEL MAIN DRAIN VALVE (NORMALLY 2 INCH NPT CLOSED) CONNECTIOf TO DRA W 1 INCH NPT CONNECTION FOR LOCAL SPRINKLER SYSTEM 112 INCH NPT AIR SUPPLY CONNECTION PRESSURE FOR OPTIONAL GAUGE AIR PRESSURE SYSTEM SWITCH AIR SUPPLY PRESSURE SUPPLY GAUGE \ /� 1 INCH NPT CONNECTION FOR LOCAL SPRINKLER SYSTEM ALARM / q AIR SUPPLY PRESSURE 1-1/4 INCH NPT GAUGE SYSTEM CONNECTION WATER TO DRAIN SUPPLY PRESSURE GAUGE,- GRQ211JED PLING OR FLANGE ADAPTER LOW AIR PRESSURE ALARM SWIT SYSTEM AIR SUPPLY CONTROL VALVE (NORMALLY s / OPEN) LOW BODY DRAIN VALVE (NORMALLY CLOSED) AUTOMATIC DRAIN VALVE 112 INCH NPT CONNECTION FOR OPTIONAL ACCELERATOR 112 INCH NPT CONNECTION FOR SYSTEM AIR SUPPLY AIR SUPPLY CONTROL VALVE (NORMALLY OPEN) A o 0 o c i o c MAIN DRAIN VALVE (NORMALLY I CLOSED) D 2 INCH NPT CONNECTION 6 INCH (DN150) TO DRAIN MODEL DPV -1 DRY PIPE VALVE NOTES: (FxF SHOWN) 1. INSTALL TRIM ASSEMBLIES IN ALPHABETICAL ORDER. 2. SEE FIGURE 3 FOR VALV ORT IDENTIFICATION. 3. ROUTE 1/4" TU G TO DRIP FUNNEL. NOTES: 4. SLOPE 3/4" ANGLE VALVE AND 3/4" x 4 -1/2" NIPPLE (OF ASSEMBLY B) INTO DRIP FUNNEL TO FACILITATE SUFFICIENT LOW BODY DRAINAGE. LOW BODY 112 INCH NPT DRAIN VALVE CONNECTION (NORMALLY FOR OPTIO CLOSED) ACCELE OR 3 DRII FUNN AUTOMATI DRAIN V E M / -\ /'\ / I vla 1 -1/4 INCH NPT SYSTEM CONNECTION WATER SUPPLY TO DRAIN PRESSURE GAUGE FIGURE 6 - PART 2 OF 3 6 INCH (DN150) MODEL DPV -1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI- ASSEMBLED TRIM C` EL SLOPE TO FIT 112 INCH NPT CONNECTION FOR WATERFLOW PRESSURE ALARM SWITCH 3/4 INCH NPT CONNECTION FOR WATER MOTOR ALARM C ALARM TEST VALVE (NORMALLY CLOSED) ALARM / q TEST VALVE lU 1-1/4 INCH NPT SYSTEM (NORMALLY WATERFLOW CONNECTION 6 INCH (DN150) SHUT -OFF CLOSED) 3/4 INCH NPT PRESSURE TO DRAIN MODEL DPV-1 VALVE CONNECTION ALARM DRY PIPE VALVE (NORMALLY FOR WATER SWITCH (GxG SHOWN) OPEN) MOTOR ALARM FIGURE 6 - PART 1 OF 3 6 INCH (DN150) MODEL DPV -1 DRY PIPE VALVE PRE - TRIMMED ASSEMBLY 112 INCH NPT CONNECTION FOR SYSTEM AIR SUPPLY AIR SUPPLY CONTROL VALVE (NORMALLY OPEN) A o 0 o c i o c MAIN DRAIN VALVE (NORMALLY I CLOSED) D 2 INCH NPT CONNECTION 6 INCH (DN150) TO DRAIN MODEL DPV -1 DRY PIPE VALVE NOTES: (FxF SHOWN) 1. INSTALL TRIM ASSEMBLIES IN ALPHABETICAL ORDER. 2. SEE FIGURE 3 FOR VALV ORT IDENTIFICATION. 3. ROUTE 1/4" TU G TO DRIP FUNNEL. NOTES: 4. SLOPE 3/4" ANGLE VALVE AND 3/4" x 4 -1/2" NIPPLE (OF ASSEMBLY B) INTO DRIP FUNNEL TO FACILITATE SUFFICIENT LOW BODY DRAINAGE. LOW BODY 112 INCH NPT DRAIN VALVE CONNECTION (NORMALLY FOR OPTIO CLOSED) ACCELE OR 3 DRII FUNN AUTOMATI DRAIN V E M / -\ /'\ / I vla 1 -1/4 INCH NPT SYSTEM CONNECTION WATER SUPPLY TO DRAIN PRESSURE GAUGE FIGURE 6 - PART 2 OF 3 6 INCH (DN150) MODEL DPV -1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI- ASSEMBLED TRIM C` EL SLOPE TO FIT 112 INCH NPT CONNECTION FOR WATERFLOW PRESSURE ALARM SWITCH 3/4 INCH NPT CONNECTION FOR WATER MOTOR ALARM C ALARM TEST VALVE (NORMALLY CLOSED) 9 BACK OF (( Q VALVE 29 42 `\ o �P 14 / SLOPE 48 TO FIT 26 1 `\' 21 4 35 18 3 35 9 17 35 33 43 42 11 20 32 Al� 44 6 INCH (DN150) 4. ALL FITTINGS AND NIPPLES MODEL DPV -1 DRY PIPE VALVE 1 (GxG SHOWN) ROUTE 1/4" TUBING, ITEM 16, 5. CH: COMMON HARDWARE 5 TO DRIP FUNNEL, ITEM 14. 6. ITEMS 45 -48 INCLUDED NO. DESCRIPTION QTY. P/N 1 250 psi/ 1750 kPa Reducing Tee ..... VALVE ASSEMBLIES Air Pressure 29 112" x 112" x 1/4" APPLICABLE; OTH WISE Gauge ........... 1 92- 343 -1 -012 2 300 psi/ 2000 kPa 15 1 Water Pressure 40 LOW BODY DRAINAGE. (GREEN Gauge ........... 1 92- 343 -1 -005 3 1/4" Gauge Test 321 "x1 "x112" FOR OPTIONAL ELECTRICALLY Valve ............ 2 46- 005 -1 -002 4 1/4" Pressure PIPE NIPPLES: L Relief Valve ....... 1 92- 343 -1 -020 5 112" Angle Valve ... 1 46- 048 -1 -004 6 Model AD -1 25710 48 Low Air Pressure Automatic Alarm Switch, Drain Valve ....... 1 52- 793 -2 -004 7 112" Ball Valve .... 1 46- 050 -1 -004 8 112" Swing Check Valve ...... 1 46- 049 -1 -004 9 3/4" Angle Valve ... 1 46- 048 -1 -005 10 3/4" Swing Check Valve ...... 1 46 -049 -1 05 11 2" Angle Valve .... 1 46 -048- -009 12 Drip Funnel Connector ........ 1 92- 1 -1 -005 13 Drip Funnel Bracket .......... 1 2- 211 -1 -003 14 Drip Funnel ....... 1 92- 343 -1 -007 15 3/32" Vent Fitting ......... . 1 92- 032 -1 -002 16 1/4" Tube, 24" Long.... ....1 CH 17 1/4" Plug.. ......2 CH 18 112" Plug ......... 2 CH 19 3/4" Plu ......... 1 CH 20 1 " Plu .......... 1 CH 21 112" 1/4" Reducing B hing .........1 CH 22 /2" Union........ 1 CH 2 3/4" Union........ 1 CH 4 112" 90° Elbow .... 1 CH TFP1020 Page 13 of 20 NOTES: 1. SEE FIGURE 3 FOR VALVE 4. ALL FITTINGS AND NIPPLES PORT IDENTIFICATION. 1 ARE GALVANIZED ROUTE 1/4" TUBING, ITEM 16, 5. CH: COMMON HARDWARE 5 TO DRIP FUNNEL, ITEM 14. 6. ITEMS 45 -48 INCLUDED 3. SLOPE 3/4" ANGLE VALVE, 19 28 112" x 1/4" x 112" ONLY IN PRE - TRIMME ITEM 9, AND 3/4" x 4 -1/2" Reducing Tee ..... VALVE ASSEMBLIES NIPPLE, ITEM 42, INTO 29 112" x 112" x 1/4" APPLICABLE; OTH WISE DRIP FUNNEL, ITEM 14, TO Reducing Tee ..... SEPARATELY OR RED. FACILITATE SUFFICIENT 15 1 CH 40 LOW BODY DRAINAGE. (GREEN LOCATION 18 TINT) 321 "x1 "x112" FOR OPTIONAL ELECTRICALLY 46 ro ' -� y SUPERVISED , rip V N.C. ALARM � O f((I • -• VALVE '(fa J hl ((W(fd , 1 � =v� W RAI 23 42 i \12 —13 39 '- 14 22 �) I 36 35 "� I 28 I 33 3 17 NO. DESCRIPTION QTY. P/N 25 112" 45° Elbow .... 1 CH 26 112" Cross ....... 1 CH 27 112" Tee ......... 2 CH 28 112" x 1/4" x 112" CH 41 3/4" x 2" ... 1 Reducing Tee ..... 2 CH 29 112" x 112" x 1/4" CH 44 2" x 4- 1/2 "........ 1 Reducing Tee ..... 1 CH 30 3/4" 90° Elbow .... 1 CH 31 3/4" x 112" x 3/4" 46 Butterfy Valve Reducing Tee ..... 3 CH 321 "x1 "x112" Figure 577 Coupling, 7 Reducing Tee ..... 1 CH PIPE NIPPLES: L 6" (DN150) ....... 1 33 1/4" x 3" ......... 2 CH 34 112" x Close ...... 1 CH NO. DESCRIPTION QTY. P/N 35 112" x 1- 112 "...... 8 1 9 36 112" x 2" ......... 1 CH 37 112" x2- 1/2 "...... 1 41 38 112" x 3" ......... 1 CH 40 CH 40 3/4" x 1- 112 "...... 5 CH 41 3/4" x 2" ... 1 CH 31 CH 431 "x4 "...........1 CH 44 2" x 4- 1/2 "........ 1 CH 35 PRE - TRIMMED VALVE ASSEMBLIES: 24 38 5930OF06ON 46 Butterfy Valve Assembly Component: GxG DPV -1 Valves, 34 �25 Figure 577 Coupling, 7 6" (DN150) ....... 1 57760ACP FxF, FxG DPV -1 Valves, L 6" (DN150) ....... 1 7160S 47 Waterflow Pressure NO. DESCRIPTION QTY. P/N 35 112" x 1- 112 "...... 8 CH 36 112" x 2" ......... 1 CH 37 112" x2- 1/2 "...... 1 CH 38 112" x 3" ......... 1 CH 39 112" x 6" ......... 1 CH 40 3/4" x 1- 112 "...... 5 CH 41 3/4" x 2" ... 1 CH 42 3/4" x 4 -1/2" ...... 2 CH 431 "x4 "...........1 CH 44 2" x 4- 1/2 "........ 1 CH COMPONENTS INCLUDED ONLY IN PRE - TRIMMED VALVE ASSEMBLIES: 45 Model BFV -N Butterfly Valve, 6" (DN150) .. 1 5930OF06ON 46 Butterfy Valve Assembly Component: GxG DPV -1 Valves, Figure 577 Coupling, 6" (DN150) ....... 1 57760ACP FxF, FxG DPV -1 Valves, Figure 71 Flange Adapter, 6" (DN150) ....... 1 7160S 47 Waterflow Pressure Alarm Switch, Model PS10- 2..... 1 25710 48 Low Air Pressure Alarm Switch, Model PS40- 2..... 1 25730 FIGURE 6 - PART 3 OF 3 6 INCH (DN150) MODEL DPV -1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFP1O2O Page 14 of 20 7 -1/8" (180 mm) Q 9" 14 -7/8" (230 mm) (380 mm) ZZ � 0 RD 20- 7/16" (520 mm) 16-1/8" (409,6 mm) 2 -112 or 3 INCH VALVES , 11 -112" 7 -1/4" (290 mm) ---� (190 mm) '8" rim) 24-1/2" (620 mm) 9 -1/4" (235 mm) 2 -1 & 3 INCH 65 & NCH VALVE 12" 14" (300 mm) (355 mm) ^ 4 1N O (DN100) VALVE 21) FIGURE 7 - PART 1 OF 2 MODEL DPV -1 DRY PIPE VALVE INSTALLATION DIMENSIONS, PRE - TRIMMED VALVE 6 -3/4" 8" 14 -7/8" (170 mm) (200 mm) (380 mm) 16- 9/16" 9 (420,7 mm) 12-1/4" (311,2 mm) 2 -112 or 3 INCH VALVES 9 6" (150 mm) 9 -1/4" (235 mm) TFP1020 Page 15 of 20 2 -1/2 3INCH (D 5 & DN80) VALVE 12" 6" 12" 14" (300 mm) (150 mm) (300 mm) (355 mm) 4 INCH am*$l 171/4" (DN100) (440 mm) VALVE FxF: 13 -5/8" (346,1 mm) FxG: 13- 11/16" (347,7 mm) GxG: 13 -3/4" (349,3 mm) H 2 -112" (65 mm) 11 -112" 7 -1/4" (290 mm) (190 mmm) I II 18 -3/4" (475 mm) 16" (406,4 mm) FxF, FxG, or GxG 4 -1/2" (115 mm) FIGURE 7 - PART 2 OF 2 MODEL DPV -1 DRY PIPE VALVE INSTALLATION DIMENSIONS, VALVE AND SEMI- ASSEMBLED TRIM TFP1O2O Page 16 of 20 the DPV -1 will permit complete draining of the system (including any loose scale) through the main drain port. During the valve resetting procedure and after the system is completely drained, the external reset knob can be easily depressed to externally unlatch the Clapper Assembly, as shown in Figure 3E. As such, the Clapper Assembly is returned to its normal set position to facilitate setting of the dry pipe sprinkler system, without having to remove the Handhole Cover. Installation General Instructions Proper operation of the Model DPV -1 Dry Pipe Valve depends upon its trim being installed in accordance with the instructions given in this Technical Data Sheet. Failure to follow the appropriate trim diagram may prevent the DPV -1 Valve from functioning properly, as well as void listings, approvals, and the manufacturer's warranties. Failure to latch open the Clapper Assembly prior to a system hydro- static test may result in damage to the Clapper Assembly. The DPV -1 Valve must be installed in a readily visible and accessible location. The DPV -1 Valve and associated trim must be maintained at a minimum temperature of 40 °F (4 °C). Heat tracing of the DPV -1 Valve or its associated trim is not permitted. Heat tracing can result in the formation of hardened mineral deposits that are capable of preventing proper operation. The Model DPV -1 Dry Pipe Valve is to be installed in accordance with the following criteria: • All nipples, fittings, and devices must be clean and free of scale and burrs before installation. Use pipe thread sealant sparingly on male pipe threads only. The DPV -1 Valve must be trimmed in accordance with Figures 4, 5, or 6, as applicable. If the DPV -1 is to be equipped with a Dry Pipe Valve Accelerator, refer to the Technical Data Sheet TFP1105 for the VIZOR Electronic Dry Pipe Valve Accelerator or TFP1112 for the Model ACC -1 Mechanical Dry Pipe Valve Accelerator. • Care must be taken to make sure that check valves, strainers, globe valves, etc. are installed with the flow arrows in the proper direction. • Drain tubing to the drip funnel must be installed with smooth bends that will not restrict flow. • The main drain and drip funnel drain may be interconnected provided a check valve is located at least 12 inches (300 mm) below the drip funnel. The Low Body Drain Valve (Figure 4, 5, or 6) may be piped so as to discharge into the Drip Funnel or to a separate drain. • Suitable provision must be made for disposal of drain water. Drainage water must be directed such that it will not cause accidental damage to property or danger to persons. • Unused pressure alarm switch and /or water motor alarm connections must be plugged. The Pressure Relief Valve provided with the Valve Trim is factory set to relieve at a pressure of approximately 45 psi (3,1 bar), which can typically be used for a maximum normal system air pressure of 40 psi (2,8 bar). The Pressure Relief Valve may be reset to a lower or higher pressure; however, it must be reset to relieve at a pres- sure which is in accordance with the requirements of the authority having jurisdiction. To reset the Pressure Relief Valve, first loosen the jam nut and then adjust the cap accordingly — clock- wise for a higher pressure setting or counter - clockwise for a lower pressure setting. After verifying the desired pressure setting, tighten the jam nut. • Installation of an Air Maintenance Device, as described in the Technical Data Section, is recommended. • An Inspector's Test Connection as required By NFPA 13 must be provided on the system piping at the most remote location from the Model DPV -1 Valve. • Conduit and electrical connections are to be made in accordance with the requirements of the authority having jurisdiction and /or the National Electric Code. • Before a system hydrostatic test is performed in accordance with NFPA 13 system acceptance test require- ments, the Clapper Assembly is to be manually latched open (Ref. Figure 3D); the Automatic Drain Valve (Figure 4, 5, or 6) is to be temporarily replaced with a 1/2 inch NPT plug, the 3/32 inch Vent Fitting (Item 13, Figure 4; Item 15, Figure 5; or Item 15, Figure 6) is to be temporarily replaced with a 1/4 inch NPT plug, and the Handhole Cover Bolts are to be tightened using a cross -draw sequence. Valve Setting Procedure Steps 1 through 11 are to be performed when initially setting the Model DPV -1 Dry Pipe Valve; after an operational test of the fire protection system; or, after system operation due to a fire. NOTES: If the DPV -1 is equipped with a Dry Pipe Valve Accelerator, refer to its resetting instructions before resetting the DPV -1. Refer to TFP1105 for the VIZOR or TFP1112 for the ACC -1. Based on the instructions provided, reset the Accelerator at the appropriate time during the resetting of the DPV -1. Unless otherwise noted, refer to Figure 4, 5, or 6 to identify functional trim components. Step 1. Close the Main Control Valve, and close the Air Supply Control Valve. If the DPV -1 is equipped with a Dry Pipe Valve Accelerator, remove the Dry Pipe Valve Accelerator from service in accordance with its Technical Data Sheet (Refer to TFP1105 for the VIZOR or TFP1112 for the ACC -1). Step 2. Open the Main Drain Valve and all auxiliary drains in the system. Close the auxiliary drain valves after water ceases to discharge. Leave the Main Drain Valve open. Step 3. Depress the plunger of the Automatic Drain Valve to verify that it is open and that the DPV -1 Valve is completely drained. Step 4. Open the Optional Alarm Control Valve, as applicable, if it was closed to silence local alarms. Step 5. As necessary, replace all sprin- klers that have operated. Replacement sprinklers must be of the same type and temperature rating as those which have operated. NOTICE In order to prevent the possibility of a subsequent operation of an over- heated solder type sprinkler, any solder type sprinklers which were possibly exposed to a temperature greater than their maximum rated ambient must be replaced. Step 6. Push down on the Reset Knob (Figure 3E) to allow the Clapper Assembly to re -seat. Step 7. Pressurize the system with air (or nitrogen) to 10 psi (0,7 bar), and then individually open all auxiliary drain valves in the system piping to drain any remaining water in trapped sections. Close each drain valve as soon as water ceases to discharge. Also partially open the Low Body Drain Valve to assure that the riser is completely drained. Close the Low Body Drain Valve as soon as water ceases to discharge. Step 8. Refer to Table B and then restore the system to the normal system air pressure as necessary to hold the DPV -1 Valve closed. Step 9. Depress the plunger on the Automatic Drain Valve to make sure it is open and that there is no air discharging. The absence of air discharging from the Automatic Drain Valve is an indica- tion of a properly set air seat within the DPV -1 Valve. If air is discharging, refer to the Care and Maintenance section under Automatic Drain Valve Inspection to determine /correct the cause of the leakage problem. Step 10. Partially open the Main Control Valve. Slowly close the Main Drain Valve as soon as water discharges from the drain connection. Depress the plunger on the Automatic Drain Valve to make sure that it is open and that there is no water discharging. The absence of water discharging from the Automatic Drain Valve is an indica- tion of a properly set water seat within the DPV -1 Valve. If water is discharging, refer to the Care and Maintenance section under the Automatic Drain Valve Inspection to determine /correct the cause of the leakage problem. If there are no leaks, the DPV -1 Valve is ready to be placed in service and the Main Control Valve must then be fully opened. Note: After setting a fire protection system, notify the proper authorities and advise those responsible for moni- toring proprietary and /or central station alarms. Step 11. Once a week after a valve is reset following an operational test or system operation, the Low Body Drain Valve (and any low point drain valves) should be partially opened (and then subsequently closed) to relieve drain - back water. Continue this procedure until drain -back water is no longer present. Care and Maintenance The following procedures and inspec- tions should be performed as indicated, in addition to any specific requirements of the NFPA, and any impairment must be immediately corrected. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by action. The owner is responsible for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and /or national codes. The operational test procedure and waterflow pressure alarm test procedure will result in operation of the associated alarms. Consequently, notification must first be given to the owner and the fire department, central station, or other signal station to which the alarms are connected. Annual Operation Test Procedure Note: Unless otherwise noted, refer to Figure 4, 5, or 6 to identify functional trim components. Proper operation of the DPV -1 Valve (i.e., opening of the DPV -1 Valve during a fire condition) should be verified at least once a year as follows: Step 1. If water must be prevented from flowing beyond the riser, perform the following steps. • Close the Main Control Valve. • Open the Main Drain Valve. • Open the Main Control Valve one turn beyond the position at which water just begins to flow from the Main Drain Valve. • Close the Main Drain Valve. Step 2. Open the system's Inspector's Test Connection. Step 3. Verify that the DPV -1 Valve has operated, as indicated by the flow of water into the system and that all waterflow alarms operate properly. Step 4. Close the system's Main Control Valve. Step 5. Reset the DPV -1 Valve in accor- dance with the Valve Setting Procedure. Note: It is recommended that the requirement of NFPA 25 to annually inspect the inside of the valve be performed at this time and prior to resetting the DPV -1 Valve. Refer to the Automatic Drain Valve Inspection TFP1020 Page 17 of 20 sub - section Steps 2 through 5 for instructions with regard to the inspec- tion of the Clapper Facing. Quarterly Waterf low Alarm Test Procedure Testing of the system waterflow alarms should be performed quarterly. To test the waterflow alarm, open the Alarm Test Valve, which will allow a flow of water to the Waterflow Pressure Alarm Switch and /or Water Motor Alarm. Upon satisfactory completion of the test, close the Alarm Test Valve. Water Pressure Inspection The Water Pressure Gauge is to be inspected monthly (per NFPA 25) to ensure that normal system water pressure is being maintained. Air Pressure Inspection The Air Pressure Gauge is to be inspected monthly (per NFPA 25) to ensure that normal system air pressure is being maintained. Automatic Drain Valve Inspection The Automatic Drain Valve should be inspected monthly (per NFPA 25) by depressing the plunger and checking to ensure that the Automatic Drain Valve is not discharging water and /or air. A discharge of water and /or air is an indi- cation that the air and /or water seats are leaking, which could subsequently cause a false operation should the intermediate chamber become inad- vertently pressurized. If leakage is present, take the DPV -1 Valve out of service (i.e., close the main control valve, open the main drain valve, close the air supply control valve, remove the Dry Pipe Valve Accelerator from service, as applicable, in accor- dance with its Technical Data Sheet (Refer to TFP1105 for the VIZOR or TFP1112 for the ACC -1), and open the Inspector's Test Connection to relieve the system air pressure to 0 psig as indicated on the System Air Pressure Gauge), and then after removing the Handhole Cover, perform the following steps: Step 1. Make sure that the Seat Ring is clean and free of any nicks or signifi- cant scratches. Step 2. Remove the Clapper Assembly from the valve by first pulling out the Hinge Pin. Step 3. Disassemble the Clapper Facing Retainer from the Clapper so that the Clapper Facing can be removed and inspected. Make sure that the Clapper Facing does not show signs of compression set, damage, etc. Replace the Clapper Facing if there is any signs of wear. TFP1020 Page 18 of 20 Step 4. Clean the Clapper Facing, Clapper, and Clapper Facing Retainer, and then reassemble the Clapper Assembly. Step 5. Reinstall the Clapper Assembly with its Hinge Pin and then reinstall the Handhole Cover. Ordering Procedure Refer to Table A for Flange Drilling Specifications. Standard DPV -1 Dry Pipe Valve (American Standard Flange Drill- ing, Threaded Ports, and Groove Outside Diameter, as applicable) Specify: (specify size) Model DPV -1 Dry Pipe Valve with (specify Inlet x Outlet) end connections, P/N (specify). GX42r-, G.D. G_......,....... RIN 6.2 319 1 926 3 Ineh (DN80) GX42r- G.D. G_..eve ...... RIN 6.2 319 1 939 4 Inch (DN100) GxG, 4.50 inch (114,3 mm) O.D. Groove x 4.50 inch (114,3 mm) O.D. Groove...... P/N 52- 310 -1 -940 FxG, ANSI Drilled Flange x 4.50 inch (114,3 mm) O.D. Groove...... P/N 52- 310 -1 -440 Fx F, ANSI Drilled Flange x ANSI Drilled Flanged.... P/N 52- 310 -1 -040 G� G.D. G_......e ...... RIN 62 319 1 969 FX42x T.C. !"_`...eye . . '. . . RIN 52 31V�T69 FX_F Pre - Trimmed DPV -1 Assemblies with Butterfly Valve Specify: 4 Inch DPV -1 Pre - Trimmed Valve Assembly, P/N (specify) FxF ................P /N 52- 310 -3 -040 FxG ................P /N 52- 310 -3 -440 GxG ............... P/N 52- 310 -3 -940 Pre - Trimmed DPV -1 Assemblies without Butterfly Valve Specify: 4 Inch DVP -1 Pre - Trimmed Valve Assembly without Butterfly, P/N (specify) FxF ................P /N 52- 310 -4 -040 FxG ................P /N 52- 310 -4 -440 Standard Galvanized Semi - Assembled DPV -1 Trim Assembled GalvaniFed P{N 52 309 2 ooT Specify: 4 Inch DPV -1 Semi - Assembled Galvanized Trim, P/N 52- 309 -2 -001 Galvanized T-Fom, RPj 62 899 2 992 Optional Accelerator VIZOR Electronic Dry Pipe Accelerator (with Trim) (Details provided in TFP1105) Specify: VIZOR Electronic Dry Pipe Accelerator for use with the 4 or 6 inch TYCO Model DPV -1 Dry Pipe Valve trim, P/N 52- 312 -3 -001 Model ACCA Mechanical Accelerator (Details provided in TFP1112) Specify: Model ACCA Dry Pipe Accelerator, P/N 52- 311 -1 -001, and Galvanized Accelerator Trim for Model DPV -1 Dry Pipe Valve, P/N 52- 311 -2 -010 Optional 600 PSI Water Pressure Gauge Specify: 600 PSI Water Pressure Gauge, P/N 92- 343 -1 -004 Accessories Order the Technical Data Sheets for the following, as applicable, for details and additional accessories: Model PS10 -2 Potter Electric Waterflow Pressure Alarm Switch ...................... P/N 25710 Model PS40 -2 Potter Electric Low Air Pressure Alarm Switch ................ P/N 25730 Model WMA1 Water Motor Alarm ................ P/N 52- 630 -1 -001 Model AMD -1 Air Maintenance Device ................ P/N 52- 324 -2 -002 Model AMD -2 Air Maintenance Device ................P /N 52- 326 -2 -001 Model AMD -3 Nitrogen Maintenance Device ................P /N 52- 328 -2 -001 Replacement Valve Parts Specify: (description) for use with (specify size) Model DPV -1 Dry Pipe Valve, P/N (see Figure 1 Parts 1 and 2 as applicable). Replacement Trim Parts Specify: (description) for use with (specify size) Model DPV -1 Dry Pipe Valve, P/N (Figures 4, 5, or 6, Part 3 as applicable). Weights The following are the nominal weights for the valves and trim: Pre - Trimmed DPV -1 Valve Assemblies: 4 Inch (DN100) GxG Dry Pipe Valve .... 121lbs.(56kg) 4 Inch (DN100) FxG Dry Pipe Valve..... 135lbs.(64kg) 4 Inch (DN100) FxF Dry Pipe Valve..... 6 Ineh (E)N:189) 145lbs.(69kg) 6 Ineh (E)N:180) Standard Galvanised Semi - Assembled DPV -1 Trim: ........... 8 Ineh (E)N80) Valve T-FiF9 281199. ........... 4 Inch (DN100) Valve Trim ............30lbs. 6 Inch 0) (14kg) DPV -1 Valve: 4 Inch (DN100) GxG Dry Pipe Valve .....57lbs. (26kg) 4 Inch (DN100) FxG Dry Pipe Valve ...... 671bs. (31 kg) 4 Inch (DN100) FxF Dry Pipe Valve ...... 77lbs. (36kg) 6 Ineh (IDN189) a Inch (DIS i50) Other DPV -1 Dry Pipe Valves Notes: Other DPV -1 Dry Pipe Valves are valves ordered with a any combi- nation of flange, threaded ports, or groove outside diameter not offered under "Standard DPV -1 Dry Pipe Valve" offerings. Valves with NPT threaded ports are intended for use with the "Standard Galvanized Semi - Assembled DPV -1 Valve Trim" offered and detailed in this document. Valves with ISO threaded ports are intended for use with special order trim that is provided by local distributors to meet the specific needs of certain localities. Please contact your local distributor regarding valves and valve trim for specific localities. Specify: (specify size) Model DPV -1 Dry Pipe Valve with (specify inlet x outlet) connections with (specify NPT or ISO) threaded ports, P/N (specify). Part Numbers For Other 2 !Q ineh (DN66) Dry Pipe Valves \/..1..es mth ITT Port -s 3.99"(76,1 RqRq) E)Htside Dia. GHtsmde Die rte. -..eve n /AI 62 399 i 939 Valves with 160 Perts G')E ,, 2.88"(73,9 RqRq) E)Htside Dia. Gbitsmde Die rte.-......,. ................ nine 62 onn i nnn 3.99"(76,1 RqRq) E)Htside Dia. nine 62 onn 1 nnn Part 61...«L.ers For Other 7 1...eh (DN80) Dry Pipe Valve-s Valves with 160 Perts 3.69"(88,9 FqFq) GHtside Dia. GFeeve 3E 3.69" (88,9 RqRq) nine 62 399 i 922 Part Numbers For Other 4 Inch (DN100) Dry Pipe Valves Valves with NPT Ports FxG, ISO Flange x 4.50" (114,3 mm) Outside Dia. Groove ................ P/N 52- 309 -1 -253 FxG, AS Flange x 4.50" (114,3 mm) Outside Dia. Groove ................ P/N 52- 309 -1 -613 FxG, JIS Flange x 4.50" (114,3 mm) Outside Dia. Groove ................ P/N 52- 309 -1 -813 Fx F, ISO Flange x ISO Flange ................ P/N 52- 309 -1 -133 Fx F, AS Flange x AS Flange ................ P/N 52- 309 -1 -513 Fx F, JIS Flange x JIS Flange ................ P/N 52- 309 -1 -713 Valves with ISO Ports GxG, 4.50 "(114,3 mm) Outside Dia. Groove x 4.50" (114,3 mm) Outside Dia. Groove ................ P/N 52- 309 -1 -923 FxG, ISO Flange x 4.50" (114,3 mm) Outside Dia. Groove ................ P/N 52- 309 -1 -213 Fx F, ISO Flange x ISO Flange ................ P/N 52- 309 -1 -113 TFP1020 Page 19 of 20 FxG, JIS Flange x 6.62" (168,3 mm) Outside Dia. Groove ................ P/N 52- 309 -1 -815 FxG, JIS Flange x 6.50" (165,1 mm) Outside Dia. Groove ................ P/N 52- 309 -1 -835 Fx F, ISO Flange x ISO Flange ................ P/N 52- 309 -1 -135 Fx F, AS Flange x AS Flange ................ P/N 52- 309 -1 -515 Fx F, JIS Flange x JIS Flange ................ P/N 52- 309 -1 -715 Valves with ISO Ports GxG, 6.62 "(168,3 mm) Outside Dia. Groove x 6.62 "(168,3 mm) Outside Dia. Groove ................ P/N 52- 309 -1 -925 GxG, 6.50 "(165,1 mm) Outside Dia. Groove x 6.50 "(165,1 mm) Outside Dia. Groove ................ P/N 52- 309 -1 -945 FxG, ISO Flange x 6.62 "(168,3 mm) Outside Dia. Groove ................ P/N 52- 309 -1 -215 FxG, ISO Flange x 6.50 "(165,1 mm) Outside Dia. Groove ................ P/N 52- 309 -1 -315 Fx F, ISO Flange x ISO Flange ................ P/N 52- 309 -1 -115 TFP1020 Page 20 of 20 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1- 215 - 362 -0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. tgcA3 tqC0 Fire & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Model 513 (13) Riser Manifold 1 -112 thru 6 Inch (DN40 thru DN150) For NFPA 13 Sprinkler Systems General Description The Figure 513 (13) Riser Manifolds described in this technical data sheet provide the necessary waterflow alarm, pressure gauge, alarm test ori- fice, drain, and sight glass equipment in a single assembly for use in NFPA 13 sprinkler systems as follows: NFPA 13* • 1 -1/2 thru 6 Inch (DN40 thru DN150) Groove x Groove *Although the Riser Manifold described in this data sheet is intended for NFPA 13 sprinkler systems, it may be used for NFPA 13D or 13R residential sprinkler systems, where a test orifice of 5.6K (80K) is accept- able. The variety of sizes and grooved end connections allow cost effective and easy transition to check valves, control valves, and system piping. The Riser Manifolds may be installed in either the horizontal (flow switch on top) or verti- cal (flow going up) for both single sprinkler rises and floor control in high rises. WARNING The Riser Manifolds described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having jurisdic- tion. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals The Figure 513 (13) Riser Manifolds with a cover tamper switch for the wa- terflow alarm switch are UL Listed, ULC Listed, and FM Approved. The Figure 513 (13) Riser Manifolds without a cover tamper switch for the waterflow alarm switch are UL Listed and FM Approved. Maximum Working Pressure 175 psi (12,1 bar) Test Orifice 5.6K (80K) Assembly The manifold body of the Figure 513 is ductile iron, whereas the manifold body of the Figure 13 is cast iron. The two assemblies are completely inter- changeable in function, application, and end -to -end laying length. Finish Red painted. Installation The Riser Manifolds may be installed in either the horizontal (flow switch on top) or vertical (flow going up). The inlet of the Riser Manifold may be di- rectly connected to a shut -off control valve. NOTES Where applicable pipe thread sealant is to be applied sparingly. Use of a non - hardening pipe thread sealant is recommended. Never remove any piping component nor correct or modify any piping defi- ciencies without first depressurizing and draining the system. Step 1. Install the manifold body with the flow arrow pointing in the down- stream position using threaded con- nections and /or listed mechanical grooved connections, as applicable Step 2. Connect the drain line, and then close the drain valve. Step 3. Refer to Figure 3 for wiring guidance. All wiring must be per- formed in accordance with the Author- ity Having Jurisdiction and /or the Na- tional Electrical Code. Step 4. Refer to Figure 4 for optional relief valve. Step 5. Place the system in service by filling the system with water. When fill- ing the system, partially open the con- trol valve to slowly fill the system. Fill- ing the system slowly will help avoid damaging the waterflow alarm switch. After the system is fully pressurized, completely open the control valve. Step 6. Secure all supply valves open. Page 1 of 6 APRIL, 2006 TFP962 Page 2 of 6 NO. DESCRIPTION QTY. P/N 1 1 -1/2" Manifold Body, Male x Female NPT..... 1 N/A Groove x Groove ....... 1 N/A 2 Waterflow Alarm Switch: VSR -SF with Paddle, UL /FM ............... 1 971 - 096 -00 VSR -SF with Paddle and Cover Tamper Switch, ULC /FM .............. 1 976 - 519 -02 3 300 psi /2000 kPa Water Pressure Gauge .. 1 2341 1 10" (254,0 mm) 14 -1/4" Male x Female NPT, (362,0 mm) Groove x Groove Manifolds Inspector's Test 11 -1/8" (282,6 mm) g Drain Valve Drain Valve Male x Male NPT (Normally set O Manifolds (Normally to "Drain ") Closed) (1 %4 m NOTES: 1. Approximate weight, 11.2 lbs. (5,1 kg). 2. ULC Listed Manifolds are equipped with Cover Tamper Switches installed internal to the Waterflow Alarm Switches. 3. CH: Common Hardware / 3 CD �o F 1 2 5- 3116" 3 -1/2" 1„ (131,8 mm) (88,9 mm) m) NPT 6 -1/8" (155,6 mm) 12 -5/8" (320,7 mm) FIGURE 1 1 -112 INCH (DN40) RISER MANIFOLD ASSEMBLYAND DIMENSIONS TFP962 TFP962 2 INCH (DN50) MANIFOLD NO. DESCRIPTION QTY. P/N 1 2" Manifold Body, Groove x Groove ..... N/A Groove x Groove ...... 1 N/A Alarm Swit UL /FM ..... ......... 1 976 -357 -04 Paddle, 2 Inch Cover mper Switch, .... ........ 1 976 - 357 -01 P die and 13 -1116 Water Pressure Gauge per Switch, >Water 13.5 (DN50) ..............1 1 976 - 520 -01 000 kPa (161,9) (331,8) ssure Gauge .. 1 2341 2 -1/2 INCH (DN65) MANIFOLD NO. DE SCRIPTION QTY. P/N 1 2 -1/2" Manifold Body, Groove x Groove ..... N/A Groove x Groove ....... 1 N/A 2 WatertlowAlarm Switch: UL /FM ..... ......... 1 976 -357 -04 VSC with Paddle, 2 Inch Cover mper Switch, UL /FM ...............1 1 976 - 357 -02 VSC with Paddle and 13 -1116 Water Pressure Gauge Cover Tamper Switch, 13.5 (DN50) ULC /FM .............. 1 976 - 520 -02 3 300 psi /2000 kPa (161,9) (331,8) Water Pressure Gauge .. 1 2341 3 INCH (DN80) MANIFOLD NO. DESCRIPTION QTY. P/N 1 3" Manifold Body, Groove x Groove ..... N/A Groove x Groove ...... D N/A 2 WatertlowAlarm Swit UL /FM ..... ......... 1 976 -357 -04 VSC with PZ 2 Inch Cover mper Switch, UL /FM ........ 1 976 - 357 -03 VSC with d 13 -1116 Water Pressure Gauge Cover mper Switch, 13.5 (DN50) U M .............. 1 976 - 520 -03 3 0 psi /2000 kPa (161,9) (331,8) Water Pressure Gauge .. 1 2341 NOTES: 1. ULC Listed Manifolds are equipped with Cover Tamper Switches installed internal to the Waterflow Alarm Switches. 2. CH: Common Hardware 41NCH (DN100) MANIFOLD NO. DESCRIPTION QTY. P/N 1 4" Manifold Body, ifold Body, Groove x Groove ..... N/A 2 WatertlowAlarm Swit D VSC with Paddle HowAlarm Swi UL /FM ..... ......... 1 976 -357 -04 VSC with ddle and 2 Inch Cover mper Switch, VWaterHowAlarmSwi ..... ......... U M ..............1 976 -520 -04 3 0 psi /2000 kPa 13 -1116 Water Pressure Gauge .. 1 2341 Page 3 of 6 6 INCH (DN150) MANIFOLD RIPTION QTY. P/N ifold Body, A B e x Groove ..... D N/A HowAlarm Swi G H ith Paddle 2 Inch 16 -3/4 VWaterHowAlarmSwi ..... ......... 1 976 - 35 7 -05 ith ddle and 13 -1116 3 -1/2 mper Switch, 13.5 (DN50) M ..............1 (330,2) 976 - 520 -05 i /2000 kPa (161,9) (331,8) Pressure Gauge .. 1 2341 Manifold Nominal Installation Dimensions in Inches and mm Drain Size Weight Size A B C D E F G H lbs. (kg) 2 Inch 16 -3/4 13 9116 5 -3/8 6 -3/8 13 -1116 3 -1/2 1" NPT 13.5 (DN50) (425,5) (330,2) (14,3) (136,5) (161,9) (331,8) (88,9) (6,1) 2 -1/2 Inch 17 -3116 13 1 5 -3/4 6 -7/8 13 -3/4 3 -1/2 1 -1/4" NPT 16.8 (DN65) (436,6) (330,2) (25,4) (146,1) (174,6) (349,3) (88,9) (7,6) 3 Inch 17 -3116 13 1 6 7 -1/8 14 -1/4 3 -1/2 1 -1/4" NPT 18'7 (DN80) (436,6) (330,2) (25,4) (152,4) (181,0) (362,0) (88,9) (8,5) 4 Inch 20 -1/2 13 4 -5116 7 -9116 9 -1116 16 -5/8 4 -1/2 2" NPT 32.7 (DN100) (520,7) (330,2) (109,5) (192,1) (230,2) (422,3) (114,3) (14,8) 6 Inch 20 -1/2 13 4 -5116 8 -1/2 10 18 -1/2 6 -5/8 2" NPT 41.6 DN150 520,7 330,2 109,5 215,9 254,0 469,9 168,3 18,9 1 3 Drain Valve D (Normally q P Closed) A v 2 B o O Y� D Test C &Drain Valve (Normally set E to "Drain ") H F - FIGURE 2 2 thru 6 INCH (DN50 thru DN150) RISER MANIFOLD ASSEMBLY AND DIMENSIONS of Page 4 of 6 TFP962 SWITCH TERMINAL CONNECTIONS UNINSULATED CLAMPING SEVERED LOOPED SECTION CAUTION: PLATE STRIPPED SINGLE An uninsulated section of a TERMINAL CONDUCTOR single conductor is not permitted to be looped around ENDS SEPARATE CONDUCTORS CLAMPING the terminal and serve as two PLATE separate connections. The TERMINAL wire must be severed to serve INCOMING as two separate connections, thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. OUTGOING IMPROPER CONNECTION METHOD PROPER CONNECTION METHOD WATERFLOW SWITCH TYPICAL ELECTRICA CONNECTIONS CONTACTS .......... SPDT (Form C) END OF LINE LOCAL RESISTOR CONTACT RATING .... 5A @ 125 VAC SIGNAL 2.5A @ 30 VDC DEVICE RNO NC NC NO NO • �G NC 1 COM COM COM CONTROL POWER PANEL NO FLOW NON - SUPERVISED STYLE B /CLASS B CONDITION CIRCUIT SUPERVISED CIRCUIT (SEE NOTE) NOTE: For supervised circuits, see "Switch Terminal Connections" above. The Waterflow Alarm Switch has two switches, one can be used to operate a central station, proprietary or remove signaling unit, while the other contact is used to operate a local audible or visual annunciator. COVER TAMPER SWITCH (ULC ASSEMBLIES ONLY) CONTACTS .......... SPDT (Form C) CONTACT RATING .... 3A @ 250 VAC 5A @ 125 VAC 1 mA @ 5 VDC min. NO % • NC COM CONTACTS SHOWN WITH COVER IN PLACE FIGURE 3 WIRING GUIDANCE TFP962 Page 5 of 6 To ins NO. DESCRIPTION QTY. P/N NO. DESCRIPTION QTY. P/N T (DN40) Manifold only: To nstall optional Pressure Relief Trim on 1 3/8" Copper Tubing, 2 Pressure Relief Valve, a 1 -1/2" (DN40) Manifold, a 1/2" NPT outlet 2" '"'5^�^- `.�; anife'l^ .... 1 971I4 -91- 175 psi, Nonadjustable .. 1 198 - 066 -00 must be provided by the installer on the 2 -1/2" (DN65) and 3 90° Compression Fitting system outlet piping, and a connection back 3 (DP199) Manifolds .... 1 971 - 124 -02 Fitting ................ 2 CH to the manifold drain trim must be fabricated ^ "'^"'� '^ and 4 1" x 1/2" Reducing Hex with installer supplied 3/8" copper tubing. nom,, 03 ... 1 Bushing .............. 1 CH Discard unused trim components. Care and Maintenance The following inspection procedure must be performed as indicated, in ad- dition to any specific requirements of the NFPA, and any impairment must be immediately corrected. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and /or national codes. NOTES No attempt is to be made to repair any N65), �F Ad CH: Common Hardware 3 1/2" NPT Installer Outlet Provided System Outlet Piping Installer Fabricated 2 0 0 3/8" Copper Tubing ^ Manifold Drain Trim 1 O FIGURE 4 OPTIONAL PRESSURE RELIEF VALVE Riser Manifold component in the field. Only the pressure gauge, waterflow alarm switch, or relief valve can be replaced. If any other problems are encountered the entire riser manifold must be replaced. The alarm /flow test procedure will re- sult in operation of the associated alarms. Consequently, notification must be given to the ownerand the fire department, central station, or other signal station to which the alarms are connected, and notification must be given to the building occupants. Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the effected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system I n service, notify the proper authorities and advise those responsible for moni- toring proprietary and /or central sta- tion alarms. Alarm /Flow Test Procedure Step 1. Place the test & drain Valve in the "test' position. Step 2. Fully open the drain valve. Make certain that drainage water will not cause any damage or injury. Step 3. Verify operation of associated alarms. Step 4. Close the drain valve Step 5. Place the test & drain Valve in the "drain" position. Step 6. Verify that the residual (flow- ing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. Step 7. Close the drain valve Step 8. Verify that the static (not flow- ing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. Page 6 of 6 TFP962 Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and /or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Information Riser Manifold: Specify; Size (specify), Figure 513, (specify connection type inlet x outlet) Riser Manifold (specify - without or with) a cover tamper switch for the waterflow alarm switch, P/N (specify). NOTES Orders for Figure 513 may be filled with a Figure 13. The two assemblies are completely interchangeable in function, application, and end -to -end laying length. If a ULC Listing is required, the Riser Manifold must be ordered with a cover tamper switch for the waterflow alarm switch. UL /ULC /FM Assemblies With Cover Tamper Switch IVIT x FT . . . . . . . . . . . . . . TT-T000 MT X MT .............. omi nQT ( Erb ........ oinionnn 2 -1/2 Inch (DN65) G x G ................ P/N 4091 3'ae�i (BPl�9j 6 x G ................ PIN 4092 4-IReh (DISAGG) G N ^ ........... PIN 40Q9 6 IReh EDIS11 6)( 9 ................ PIN 40Q9 UL /FM Assemblies A.4T)6 CT .............. PIN 4Q99 1 V2 I ^T............ W# 486 -* G ................ w�a aes3e 2 -1/2 Inch (DN65) G x G ................ P/N 4061 3 IFIGh (DN80) Erb ^ ........... PIN 4Q9;2 6 x 9 ................ PIN 4869 6IReh(DIS1450) 6* 9 ................ PIN 4e99 Optional Pressure Relief Valve: Specify: Operational Pressure Relief Valve and Trim for use with (specify size) Figure 513 or 13 Series Riser Manifold, P/N (specify). T, 2'. AF 2 " ............... PIN 4063 2 -1/2" erg ............... P/N 4072 n "� AF6— PFN 4973 Replacement Parts: Specify: (description) for use with Fig- ure 513 or 13 Riser Manifold, P/N (Ref. Figure 1 or 2, as applicable). TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 F -30 (4 -10) GAST UL Listed Oilless Piston Air Compressors for Dry Sprinkler Systems Tankless / Tank Mounted UL1450 Listed No lubrication required Fully automatic Direct Drive Corrosion resistant internal parts Compact, easy to install High cycle rating pressure switch 4LCB- 55S- M450GX 6LCF- 46S- M616NEX UL1450 Listed Gast Oilless Piston Air Compressors All air compressors shown have open motors. Single phase motors have internal thermal protection. Dual voltage motors are shipped pre -wired for the higher voltage. All tank units are wired for 115 volts. Tankless Units Tan kless / Automatic air compressors have inlet filters, a safety valve, pressure switch, check valve, tubing and fittings. SINGLE CYLINDER MODEL TWIN CYLINDER MODEL For ressure air maintenance devices IRFLOW POWER OPERATING VOLTAGE DIMENSIONS PIPE SHIP MODEL at 13 P ATING FREQUENCY INCHES SIZE WT. NUMBER CFM HP A B C IN. NPT LBS 1 LAA 55S M 1000X 1.0 1/6 1 115-60-1 13.75 9.17 1 /4 23.0 3LEM- 55S - M345EX 1.5 1/4 1 115 -60 -1 7.67 1 9.37 1/4 29.7 4LCB- 55S- M450GX 2.0 1/3 1 115 -60 -1 6.05 16.09 13.29 40.0 Factory setting: cut -in 13 psi T 2 psi / cut -out 18 psi T 2 psi For Dry Sprinkler systems Maximum Gallons FREE AIR FLOW POWER OPERATING VOLTAGE DIMENSIONS PIPE SHIP MODEL in System to Pump at 40 PSI RATING FREQUENCY SIZE WT. NUMBER to 40 PSI in 30 Min. INCHES In support of NFPA Standard 13 CFM HP HZ A B C IN. NPT LBS 1 LAA -46S -M l OOGX 90 1.0 1/6 115 -60 -1 8.31 15.25 9.75 1/4 22.5 2LAF- 46S- M200EX 150 1.5 1/4 115 -60 -1 8.31 15.59 9.75 1/4 24.2 3LBA- 46S- M3000X 180 2.0 1/3 115 -60 -1 8.31 15.55 12.35 1/4 30.2 3LEM -46S- M345EX 180 2.0 1/3 115 -60 -1 9.63 14.81 9.37 1/4 29.2 4LCB - 46S- M450GX 300 3.1 112 115/230 -60 -1 8.81 16.09 13.32 1/4 39.5 5LCA- 46S- M550GX 400 4.2 3/4 115/230 -60 -1 8.81 16.96 13.37 1/4 47.5 6LCF- 46S- M616NEX 600 5.9 1 115/208 - 230 -60 -1 8.79 18.91 13.43 3/8 55.2 7LDE- 46S -M7507 800 7.9 11/2 115/230 - 110/220 -60 -1 9.80 25.25 12.50 3/8 73.0 8LDF- 46S -M850X 1000 8.84 2 115/230 - 50/60 -1 9.80 25.90 12.60 3/8 90.0 Factory setting: cut -in 40 psi T 2 psi / cut -out 50 psi T 2 psi UL Fire Protection . ile EX5324 Evaluated to UL145�erated air compressors for use in sprinkler systems ASME Coded Ta ackages Tank mounted compr rs include gauge, pressure switch, shut off valve, drain valve, c k valve and safety valve. All tank units are wired for 115 vo For Dry Sprinkler systems AK620D Maximum Gallons FREE AIR FLOW POWER MODEL NUMBER in System to Pump at 40 PSI RATING to 40 PSI in 30 Min. 15 "hose assy. 1/4" NPT F In support of NFPA Standard 13 CFM HP -46T -M l OOGX 90 1.0 1/6 F - 46T- M200FX 1.5 1/4 150 A - 46T- M3000X 2.0 1j3 180 M - 46T- M345FX 2.0 1j3 180 B- 46T- M450GX IA 3.1 300 1 /2 A - 46T- M550GX 4.2 400 3/4 F- 46T- M616NFX 5.9 600 1 E- 46T -M750X 7.9 800 11/2 F- 46T -M850X 1000 8.84 2 Factory setting: cut -in 30 psi T 2 psi/ cut -out 50 psi T 2 psi Pa rt Number Description AJ550 Check Valve 1/4 °NPT female AJ550A Check Valve3 /8 "NPT female L AF631 Shock/isolation mounts 1/4 - 20 thread both ends AF633 Shock/isolation mounts 5 /16 - 18 thread both ends AS] 88 Pressure Switch (cut -in 13 psi, cut -out 18 AK620D Pressure Switch (cut -in 40 psi, cut -out 50 AF163F AF634 AH332 Pressure Switch (cut -in 30 psi, cut -out 50 15 "hose assy. 1/4" NPT F I 16 "hose assv. 3 /R "NPTF SING VOLTAGE HZ 115 -60 -1 115 -60 -1 26 115 -60 -1 26 115 -60 -1 26 115/230 -60 -1 33 115/230 -60 -1 33 115/208- 230 -60 -1 33 15/230-110/220-60-11 38 115/230 - 50/60 -1 38 Used On (See charts forfull model number) 1 LAA -55S 1 LAA -46S 3LEM -55S 2LAF -46S 4LCB -55S 3LBA -46S 3LEM -46S 4LCB -46S 5LCA -46S 6LCF -46S 7LDE -46S 8LDF -46S 1 LAA -55S 1 LAA -46S 3LEM -55S 2LAF -46S 3LBA -46S 3LEM -46S 4LCB -55S 4LCB -46S 5 LCA -46S 6LCF -46S 7LDE -46S 8LDF -46S All 55S tankless models All 46S tankless models All 46T tank models All models with 1/4" NPT H All models with 3 /R " NPT Fi1 1 LAA -46T 2LAF -46T 3LEM -46T 3LBA -46T 4LCB -46T 5LCA -46T 6LCF -46T 7LDE -46T 8LDF -46T 1 LAA -46T 2LAF -46T 3LBA -46T 4LCB -46T 5LCA -46T 6LCF -46T 7LDE -46T 8LDF -46T E1 DIMENSIONS INCHES B 11 21 21 21 26 26 25.5 28.6 29.1 C 9 13 13 17 17 17 18 18 B nrc PIPE SHIP TANK SIZE WT. SIZE IN. NPT LBS GALLON 1/4 44 2 1/4 78 12 1/4 80 12 1/4 83 12 1/4 109 20 1 4 115 20 1/4 9 30 3/8 185 30 3/8 200 3 AT670 Compressor Mounting Bracket AT670A 0 For mounting all 55S and 46S tankless models to all shapes and sizes of riser pipes. Comes complete with all the hardware and adjustable stainless steel straps. Contact your local sprinkler supply company or Gast distributor to order. System Air Capacity per 1' pipe (Based on actual internal diameter) Diameter (in.) 112 _ 3/4 1 11/4 1 1/2 2 21/2 3 31/2 4 5 6 8 Gallons .016 .028 .045 .078 .106 .174 .248 .383 .513 .660 1.04 1.50 2.66 GAST IBCr CORPORATION GAST Manufacturing, Inc. A Unit of IDEX Corporation Post Office Box 97 2300 M -139 Highway Benton Harbor, Michigan 49023 -0097 Phone 269- 926 -6171 Fax 269- 925 -8288 www.gastmfg.com Gast Hong Kong Unit 12, 21/17, Block B New Trade Plaza 6, On Ping Street, Shatin N. T. Hong Kong Phone 852 - 2690 -1008 Fax 852 - 2690 -1012 GAST GROUP LTD A Unit of IDEX Corporation Unit 11, The 10 Centre Nash Road Redditch, B98 7AS United Kingdom Phone +44 (0)1527- 504040 Fax +44 (0)1527- 525262 ®Registered Trademark/TmTrademark of Gast Manufacturing Inc., Copyright 02010 Gast Manufacturing Inc. All rights reserved. (E)POTTER The Symbol of Protection QQ.PMER The Symbol o /Pro cff,n St. Louis, Missouri ew Model Number / C PS10 -2 `C 5- Ordering Information Model Description Stock No. PS10 -1 Pressure switch with one set 1340103 SPDT contacts PS 10 -2 Pressure switch with two sets 1340104 SPDT contacts Hex Key 5250062 Cover Tamper Switch Kit 0090200 Tamper Cover incorporates tamper resistant fastener that requires a special key for removal. One key is supplied with each device. For optional cover tamper switch kit, order Stock No. 0090200. See bulletin #5401200 PSCTSK. Installation The Potter PS10 Series Pressure Actuated Switches are designed for the detection of a waterflow condition in automatic fire sprinkler systems of particular designs such as wet pipe systems with alarm check valves, dry pipe, preaction, or deluge valves. The PS10 is also suitable to provide a low pressure supervisory signal; adjustable between 4 and 15 psi (0,27 and 1,03 BAR). 1. Apply Teflon tape to the threaded male connection on the device. (Do not use pipe dope) 2. Device should be mounted in the upright position (threaded connection down). 3. Tighten the device using a wrench on the flats on the device. Wiring Instructions 1. Remove the tamper resistant screw with the special key provided. 2. Carefully place a screwdriver on the edge of the knockout and sharply apply a force sufficient to dislodge the knockout plug. See Fig 9 3. Run wires through an approved conduit connector and affix the connector to the device. 4. Connect the wires to the appropriate terminal connections for the service intended. See Figures 2,4,5, and 6. See Fig 7 for two switch, one conduit wiring. Testing The operation of the pressure alarm switch should be tested upon completion of installation and periodically thereafter in accordance with the applicable NFPA codes and standards and /or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Wet System Method 1: When using PS 10 and control unit with retard - connect PS 10 PS10 SERIES PRESSURE SWITCH UL, cUL, and CSFM Listed, FM and LPC Approved, NYMEA Accepted, CE Marked Dimensions: 3.78" (9,6cm)W x 3.20" (8, lcm)D x 4.22" (10,7cm)H Conduit Entrance: Two knockouts provided for 1/2" conduit. Individual switch compartments and ground screws suitable for dissimilar voltages. Enclosure: Cover - Die -cast with textured red powdercoat finish, single cover screw and rain lip. Base - Die -cast Pressure Connection: Nylon 1/2" NPT Male Factory Adjustment: 4 - 8 PSI (0,27 - 0,55 BAR) Differential: 2 PSI (0,13 BAR) typical Maximum System Pressure: 300 PSI (20,68 BAR) Switch Contacts: SPDT (Form C) 10.1 Amps at 125/250VAC, 2.0 Amps at 30VDC One SPDT in PS10 -1, Two SPDT in PS10 -2 Environmental Specifications: NEMA 4/IP66 Rated Enclosure - indoor or outdoor when used with NEMA 4 conduit fittings. Temperature range: -40 °F to 140 °F ( -40 °C to 60 °C) Service Use: Automatic Sprinkler NFPA -13 One or two family dwelling NFPA -13D Residential Occupancy up to four stories NFPA -13R National Fire Alarm Code NFPA -72 into alarm port piping on the input side of retard chamber and electrically connect PS 10 to control unit that provides a retard to compensate for surges. Insure that no unsupervised shut -off valves are present between the alarm check valve and PSI 0. Method 2: When using the PS 10 for local bell application or with a control that does not provide a retard feature -the PS 10 must be installed on the alarm outlet side of the retard chamber of the sprinkler system. Testing: Accomplished by opening the inspector's end -of -line test valve. Allow time to compensate for system or control retard. Note: Method 2 is not applicable for remote station service use, if there is an unsupervised shut-off valve between the alarm check valve and the PS 10. Wet System With Excess Pressure Connect PS 10 into alarm port piping extending from alarm check valve. Retard provisions are not required. Insure that no unsupervised shut -off valves are present between the alarm check valve and the PSI 0. Testing: Accomplished by opening the water by -pass test valve or the inspector's end -of -line test valve. When using end -of -line test, allow time for excess pressure to bleed off. Dry System Connect PS10 into alarm port piping that extends from the intermediate chamber of the alarm check valve. Install on the outlet side of the in -line check valve of the alarm port piping. Insure that no unsupervised shut -off valves are present between the alarm check valve and the PSI 0. Testing: Accomplished by opening the water by -pass test valve. Note: The above tests may also activate any other circuit closer or water motor gongs that are present on the system. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866 - 956 - 0988 /Canada 888- 882 -1833 • www.pottersignal.com PRINTED IN USA MFG. #5400928 - REV D -1 PAGE 1 OF 3 12/10 (E)POTTER The Symbol of Protection Dimensions Fig. 1 OO 2.87 SCREWS ADJUSTMENT [72.97] KNOB ® 4.22 [107.19] 1/2" NPT 2.48 1.60 [62.87] [40.64] 3.78 3.20 [95.89] [81.28] NOTE: To prevent leakage, apply Teflon tape sealant to male threads only. DWGN 930 -1 PS10 SERIES PRESSURE SWITCH Switch Clamping Plate Terminal Fig. 2 d DWG# 923 -3 OVA AWARNING An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. Typical Sprinkler Applications Fig. 3 WET SYSTEM WITH WET SYSTEM WITHOUT DRY SYSTEM EXCESSPRESSURE EXCESSPRESSURE PS10 PS10 PS10 W -1TER W -1TER R- \TER MOTOR MOTOR MOTOR L GONG GONG GONG RBVS CHECK WET RBVS DRY VALVE RBVS SYSTEM WET SYSTEM ALARM SYSTEM ALARM CHECK ALARM CHECK �! V:1L \'E CfTLCK RETARD VALVE VALVE W -1TER R'- \TER W -1TER OS&Y BY-PASS OS&Y BY-PASS OS &Y BY-PASS VALVE VALVE VALVE VALVE VALVE V1LNT DWG. #923 -2AA A CAUTION Closing of any shutoff valves between the alarm check valve and the PS 10 will render the PS 10 inoperative. To comply with NFPA -72 any such valve shall be electrically supervised with a supervisory switch such as Potter Model RBVS. Low Pressure Signal Connection Fig. 4 TO FIRE ALARM PANEL Q O NEEN PRINTED IN USA Waterflow Signal Connection Fig. 5 MFG. #5400928 - REV D -1 12/10 Local Bell For Waterflow Connection Fig. 6 NEGATIVE DC OR NEUTRAL A( POSITIVE D1 OR HOT AC PAGE 2 OF 3 (E)POTTER The Symbol of Protection One Conduit Wiring Fig. 7 Break out thin section of divider to provide path for wires when wiring both switches from one conduit entrance. AWARNIN Switch Operation Fig. 8 Terminal W/ PRESSURE APPLIED C: Common 1: Closed when installed under normal system c pressure. 2: Open when installed under normal system pressure. Closes on pressure drop. Use for low pressure supervision. --------------------------------- Terminal W/O PRESSURE APPLIED 1: Open with no pressure supplied. Closes upon detection of pressure. Use for waterflow p indication. bl 2: Closed with no c pressure applied. DWG#92R -fi •Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. -Shock hazard. Disconnect power source before servicing. Serious injury or death could result. -Read all instructions carefully and understand them before starting installation. Save instructions for future use. Failure to read and understand instructions could result in improper operation of device resulting in serious injury or death. -Risk of explosion. Not for use is hazardous locations. Serious injury or death could result. Engineer /Architect Specifications Pressure Type Waterflow Switch Pressure type waterflow switches; shall be a Model PSI 0 as manufactured by Potter Electric Signal Company, St Louis MO., and shall be installed on the fire sprinkler system as shown and or specified herein. Switches shall be provided with a11/2' NPT male pressure connection and shall be connected to the alarm port outlet of; Wet Pipe Alarm Valves, Dry Pipe Valves, Pre - Action Valves, or Deluge Valves. The pressure switch shall be actuated when the alarm line pressure reaches 4 - 8 PSI (0,27 - 0,55 BAR). Pressure type waterflow switches shall have a maximum service pressure rating of 300 PSI (20,68 BAR) and shall be factory adjusted to operate on a pressure increase of 4 - 8 PSI (0,27 - 0,55 BAR) PS10 SERIES PRESSURE SWITCH Removing Knockouts Fig. 9 �c -Do not tighten by grasping the switch enclosure. Use wrenching flats on the bushing only. Failure to install properly could damage the switch and cause improper operation resulting in damage to equipment and property. -To seal threads, apply Teflon tape to male threads only. Using joint compounds or cement can obstruct the pressure port inlet and result in improper device operation and damage to equipment. -Do not over tighten the device, standard piping practices apply. Pressure switch shall have one or two form C contacts, switch contact rating 10.1 Amps at 125/250 VAC, 2.0 Amps at 30 VDC. Pressure type waterflow switches shall have two conduit entrances one for each individual switch compartment to facilitate the use of dissimilar voltages for each individual switch. The cover of the pressure type waterflow switch shall be Zinc die -cast with rain lip and shall attach with one tamper resistant screw. The Pressure type waterflow switch shall be suitable for indoor or outdoor service with a NEMA 4/IP66 rating. The pressure type waterflow switch shall be UL Ulc and CSFM listed, FM and LPC approved and NYMEA accepted. PRINTED IN USA MFG. #5400928 - REV D -1 PAGE 3 OF 3 12/10 (E)POTTER The Symbol of Protection J Ordering Information Model Description Stock No PS40 -1 Pressure switch with one set SPDT contacts 1340403 PS40 -2 Pressure switch with two sets SPDT contacts 1340404 Hex Key 5250062 Cover Tamper Switch Kit 0090200 BVL Bleeder valve 1000018 Installation The PotterPS40 Series Supervisory Pressure Actuated Switches are designed primarily to detect an increase and/or decrease from normal system pressure in automatic fire sprinkler systems. Typical applications are: Dry pipe systems, pre- action air /nitrogen supervision, pressure tanks, air supplies, and water supplies. The PS40 switch is factory set for 40 PSI (2,8 BAR) normal system pressure. The switch marked with the word LOW is set to operate at a pressure decrease of 10 PSI (,7 BAR) at 30 PSI (2,1 BAR). The switch marked with the word HIGH is set to operate at a pressure increase of 10 PSI (,7 BAR) at 50 PSI (3,5 BAR). See section heading Adjustments and Testing if other than factory set point is required. 1. Connect the PS40 to the system side of any shutoff or check valve. 2. Apply Teflon tape to the threaded male connection on the device. (Do not use pipe dope) 3. Device should be mounted in the upright position. (Threaded connection down) 4. Tighten the device using a wrench on the flats on the device. Wiring Instructions 1. Remove the tamper resistant screw with the special key provided. 2. Carefully place a screwdriver on the edge of the knockout and sharply apply a force sufficient to dislodge the knockout plug. See Fig. 9 3. Run wires through an approved conduit connector and affix the connector to the device. A NEMA -4 rated conduit fitting is required for outdoor use. PS40 SERIES SUPERVISORY PRESSURE SWITCH UL, cUL, and CSFM Listed, FM and LPC Approved, NYMEA Accepted, CE Marked Dimensions: 3.78" (9,6cm)W x 3.20" (8,1cm)D x 4.22" (10,7cm)H Conduit Entrance: Two knockouts provided for 1/2" conduit. Individual switch compartments and ground screw suitable for dissimilar voltages Enclosure: Cover- Die -cast with textured red powdercoat finish, single cover screw and rain lip. Base- Die -cast Pressure Connection: Nylon 1/2" NPT male Factory Adjustment: PS40 -1 operates on decrease at 30 PSI (2,1 BAR) PS40 -2 operates in increase at 50 PSI (3,5 BAR) and on decrease at 30 PSI (2,1 BAR) Pressure Range: 10 -60 PSI (,7 - 4,1 BAR) Differential: Typical 1 lb. at 10 PSI (,07 at ,7 BAR) 4 lbs at 60 PSI (,28 at 4,1 BAR) Maximum System Pressure: 300 PSI (20,68 BAR) Switch Contacts: SPDT (Form C) 10.1 Amps at 125/250VAC, 2.0 Amps at 30VDC One SPDT in PS40 -1, Two SPDT in PS40 -2 Environmental Specifications: NEMA 4/IP66 Rated Enclosure - indoor or outdoor when used with NEMA 4 conduit fittings. Temperature range: -40 °F to 140 °F ( -40 °C to 60 °C) Tamper: Cover incorporates tamper resistant fastener that requires a special key for removal. One key is supplied with each device. For optional cover tamper switch kit, order Stock No. 0090200. See bulletin #5401200 PSCTSK. Service Use: Automatic Sprinkler NFPA -13 One or two family dwelling NFPA -13D Residential Occupancy up to four stories NFPA -13R National Fire Alarm Code NFPA -72 4. Connect the wires to the appropriate terminal connections for the service intended. See Figures 2,4,5,6, and 8 Adjustment And Testing The operation of the pressure supervisory switch should be tested upon completion of installation and periodically thereafter in accordance with the applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Note: Testing the PS40 may activate other system connected devices. The use of a Potter BVL (see product bulletin 8900067 for details) is recommended to facilitate setting and testing of the PS40 pressure switch. When a BVL (bleeder valve) is used, the pressure to the switch can be isolated and bled from the exhaust port on the BVL without effecting the supervisory pressure of the entire system. See Fig. 3 The operation point of the PS40 Pressure Switch can be adjusted to any point between 10 and 60 PSI (0,7 - 4,11 BAR) by turning the adjustment knob(s) clockwise to raise the actuation point and counter clockwise to lower the actuation point. In the case of the PS40 -2, both switches operate independent of each other. Each switch may be independently adjusted to actuate at any point acrosss the switch adjustment range. Initial adjustment can be made with a visual reference from the top of the adjustment knob across to the printed scale on the switch bracket. Final adjustments should be verified with a pressure gauge. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866 - 956 - 0988 /Canada 888- 882 -1833 • www.pottersignal.com PRINTED IN USA MFG. #5400930 - REV E PAGE 1 OF 3 09/12 (E)POTTER The Symbol of Protection Dimensions Fig. 1 00 2.87 SCREWS ADJUSTMENT I [72.97] KNOB ® [1007.17.1 9] 1/2" NPT 2 -48 1.60 'i [62.87] [40.64] 3.78 3.20 [95.89] [8128] NOTE To prevent leakage, apply Teflon tape sealant to male threads only. DMW931F1 Typical Sprinkler Applications Fig. 3 PS40 SUPERVISORY PRESSURE SWITCH AIR LINE SHUT -OFF PSIO VALVE ALARM LVA TEST PRESSURE VA LVE SWITCH E BVL CHECK RBVS DRY PIPE VALVE 7TEST DWG. #924 -IA OS &Y VALVE Typical Connections Fig. 4 WITH NORMAL SYSTEM PRES- PS40 -1 SURE APPLIED LOW - TERMINAL 2 CLOSES ON PRESSURE DROP. TO FIRE ALARM PANEL WATER MOTOR GONG TOE ALA PAN_ PS40 SERIES SUPERVISORY PRESSURE SWITCH Switch Clamping Plate Terminal Fig. 2 41 .411 `DLO 0 C10111 DWG# 923 -3 O AWARNING An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. A CAUTION Closing of any shutoff valves between the alarm check valve and the PS 10 will render the PS 10 inoperative. To comply with IBC, IFC, and NFPA -13, any such valve shall be electrically supervised with a supervisory switch such as Potter Model RBVS. PS40 -2 HIGH AIR LOW WITH NORMAL. SYSTEM AIR PRESSURE APPLIED HIGH - TERMINAL 1 WILL CLOSE ON PRESSURE INCREASE. DWG# 930 -2 PRINTED IN USA MFG. #5400930 - REV E PAGE 2 OF 3 09/12 (E)POTTER The Symbol of Protection Low Pressure Signal Connection High Pressure Signal Connection Fig. 5 Fig. 6 TO FIRE ALARM PANEL EOLR 9 � o n o o In Changing Pressure (With normal system pressure) Fig. 8 Terminal LOW PRESSURE SWITCH C: Common 1: Closed when installed under normal system pressure. 2: Open when installed under normal system pressure. Closes on c z pressure drop. Use for low air signal. - ------------------------------- Terminal 1: Open when installed under normal system pressure. Closes on increasein pressure. Use for high air signal. 2: Closed under normal system pressure. HIGH PRESSURE SWITCH c b c i D W O� 930-3 PS40 SERIES SUPERVISORY PRESSURE SWITCH One Conduit Wiring Fig. 7 Break out thin section of divider to provide path for wires when wiring both switches from one conduit entrance. Removing Knockouts Fig. 9 Engineer /Architect Specifications Pressure Type Waterfiow Switch Pressure type supervisory switches; shall be a Model PS40 as manufactured by Potter Electric Signal Company, St. Louis, MO., and shall be installed on the fire sprinkler system as shown and or specified herein. Switches shall be provided with a 1/2" NPT male pressure connection to be connected into the air supply line on the system side of any shut -off valve. A Model BVL bleeder valve as supplied by Potter Electric Signal Company of St. Louis, MO., or equivalent shall be connected in line with the PS40 to provide a means of testing the operation of the supervisory switch. (See Fig. 3) The switch unit shall contain SPDT (Form C) switch(es). One switch shall be set to operate at a pressure decrease of 10 PSI (0,7 BAR) from normal. If two switches are provided, the second switch shall be set to operate at a pressure increase of 10 PSI (0,7 BAR) from normal. Switch contacts shall be rated at 10.1 Amps at 125/250VAC and 2.0 Amps at 30VDC. The units shall have amaximum pressure rating of 300 PSI (20,68 BAR) and shall be adjustable from 10 to 60 PSI (0,7 to 4,1 BAR). Pressure switches shall have two conduit entrances, one for each individual switch compartment to facilitate the use of dissimilar voltages for each individual switch. The cover of the pressure switch shall be zinc die -cast with rain lip and shall attach with one tamper resistant screw. The pressure switch shall be suitable for indoor or outdoor service with a NEMA- 4/1P66 rating. The pressure switch shall be UL, ULC, and CSFM listed, FM and LPC approved and NYMEA accepted. 1J vv v+r7/d -5 •Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. -Shock hazard. Disconnect power source before servicing. Serious injury or death could result. -Read all instructions carefully and understand them before starting installation. Save instructions for future use. Failure to read and understand instructions could result in improper operation of device resulting in serious injury or death. -Risk of explosion. Not for use is hazardous locations. Serious injury or death could result. A CAUTION -Do not tighten by grasping the switch enclosure. Use wrenching flats on the bushing only. Failure to install properly could damage the switch and cause improper operation resulting in damage to equipment and property. -To seal threads, apply Teflon tape to male threads only. Using joint compounds or cement can obstruct the pressure port inlet and result in improper device operation and damage to equipment. -Do not over tighten the device, standard piping practices apply. -Do not apply any lubricant to any component of the pressure switch. PRINTED IN USA MFG. #5400930 - REV E PAGE 3 OF 3 09/12 ARGCO FIRE SPRINKLER SPARE HEADBOXES Heavy gauge steel construction Knockouts and shelf to accommodate any 1/2" or 6 Head Box 3/4" sprinkler head All- welded construction and full length hinge Red powder coated finish Slotted for easy mounting with screws, rivets or strapping (65 -10 -151) (65- 10 -151A) The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1- 800 - 854 -1015 OR LOG ONTO WWW.ARGCO.COM ZURN© Model350AF-7 WILKINS Double Check Valve Assembly Application Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. The Model 350AST shall provide protection where a potential health hazard does not exist. Ideal for use where Lead -Free' valves are required. Standard Compliance (Horizontal and Vertical) • ASSEO Listed 1015 • AWWA Compliant C510 (with gates only), and C550 • ULO Classified • C -ULO Classified • FMO Approved • CSAO Certified • IAPMOO Listed • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California • NSFO Listed - Standard 61, Annex G' • Certified to NSF /ANSI 372' by IAPMO R &T "(0.25% max. weighted average lead content) Materials ❑ - Main valve body 304L Stainless steel Access covers 304L Stainless steel Internals Stainless steel, 300 Series Hydrostatic test pressure NORYLTM, NSF Listed Fasteners and springs Stainless Steel, 300 Series Seal ring EPDM (FDA approved) O -ring Buna Nitrile (FDA approved) Features ❑ - Sizes:2 1 " 3„ 4„ 6„ g„ 10„ ❑ FSC - Maximum working water pressure 175 PSI Maximum working water temperature 140 °F Hydrostatic test pressure 350 PSI End connections ❑ FG - (Grooved for steel pipe) AWWA C606 (Flanged) ANSI B16.1 Class 125 LEAD FREE rx.ourn Certified to LOW -LEAD I NSF /ANS161 -G Up c C O Options (Suffixes can be combined) ❑ - with flanged end NRS gate valves (standard) ❑ FSC - with epoxy coated Wye type strainer (flanged only) ❑ G - with grooved end NRS gate valves ❑ GF - with grooved inlet gate connection and flanged outlet gate connection ❑ FG - with flanged inlet gate connection and grooved outlet gate connection ❑ OSY - flanged end OS &Y gate valves ❑ OSYG - with grooved end OS &Y gate valves ❑ PI - with Post Indicator Gate Valves ❑ BG - with grooved end butterfly valves with integral supervisory switches ❑ BF - with flanged end butterfly valves with integral WITH OS &Y supervisory switches Accessories ❑ Repair kit (rubber only) ❑ Thermal expansion tank (Model XT) ❑ OS & Y Gate valve tamper switch (OSY -40) MODEL 350 with OSY & FSC option k7 ni WEIGHT MODEL WITH WITH WITH B I—D 350AST WITHOUT WITH NRS WITH OS &Y WITH NRS OS &Y BUTTERFLY BUTTERFLY A SIZE GATES GATES GATES GATES GATES VALVES VALVES (GXF) (GXF) (GXG) (GXG) (GXG) (GXF) G in. mm lbs. kg lbs. I kg lbs. kg lbs. I kg lbs. kg lbs. I kg lbs. I kg 2 172 65 33 15 94 43 112 51 86 39 104 47 79 36 89 40 3 80 34 15.4 112 51 1 130 60 102 46 1120 54 83 38 96 44 MODEL o o® 0 0 4 100 35 15.8 168 76 204 93 142 64 184 83 87 150 39 68 109 180 50 82 350AST with BG option 6 150 63 29 280 127 338 153 250 114 308 140 8 200 177 80 565 256 647 293 525 238 593 269 347 112 393 178 B 10 250 177 80 769 349 865 392 717 325 807 366 443 200 501 227 A DIMENSION (approximate) MODEL 350AST B E E E WITH SIZE A LESS GATE C D OS &Y OS &Y BUTTERFLY F G BUTTERFLY VALVES NRS GATE OPEN CLOSED VALVES Fin mm in. I mm in. I mm in. I mm in. I mm in. I mm in. I mm in. I mm in. I mm in. I mm in. Imm in. I mm 2112 65 31 7!8 810 1283/41 730 1165/81 422 4 1/21114 7 1/41184 11 1!2 1 292 17 3!4 451 1153/81391 1 8 1!4 210 1 5 127 42 1067 3 80 327/8 835 293/8 746 165/8 422 41/2 114 71/4 184 12 3/4 324 20 1/4 514 17 432 8 1/4 210 5 127 43 1/2 1105 4 100 347/8 886 301/4 768 165/8 422 41/2 114 8 203 14 1/2 368 221/2 572 181/4 464 9 229 5 127 50 1270 6 150 431/2 1105 361/2 927 221/4 565 51/2 140 10 254 18 457 301/2 775 241/4 616 101/4 260 6 152 61 5!8 1565 8 200 523/4 1340 453/4 1162 291/2 749 91/4 235 11 279 21 1/8 537 37 940 281/2 724 181/2 470 83/8 213 77 1/8 1959 10 250 553/4 1416 493/4 1264 291/2 749 91/4 235 12 305 243/4 629 455/8 1159 343/4 883 181/2 470 83/8 213 853/8 2169 Zurn Industries, LLC I Wilkins Rev. H 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855 - 663 -9876, Fax 805 - 238 -5766 Date: 2/14 In Canada I Zurn Industries Limited Document No. BF- 350AST 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 Ph. 905 - 405 -8272, Fax 905 - 405 -1292 Patent No. 5,913,331 Product No. Model 350AST www.zurn.com Page 1 of 2 Flow Characteristics 0.0 55 a. a CO) 10 0 I W 5 CO) CO) W aa. 0 MODEL 350AST 2 11",5" 4" (STANDARD & METRIC) FLOW RATES (1 /s) 12.6 25.2 37.9 0 200 400 600 FLOW RATES (GPM) MQ9E6 360AST 6", 8" & 40" (STANDARDS AND ) FLOW RATE (1 /s) n (ZQ I 1 1)(z 1) 1 QO Q O Rated Flow (established by approval agencies) 50.5 104 co 69 0 J W Of 35 co co ILL Of 0 D_ 800 Or') A U IUUU GUUU 3uuu FLOW RATE (GPM) Typical Installation Local codes shall govern installation requirements. Unless oth- erwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. 0 0 z 0 U w i - ZURN WILKINS MODEL 350ASTBG +'' • ' INDOOR VERTICAL INSTALLATION 091.1 M CL C6 104 CO 0 69 w 35 co ILL T 0 D ,ru00 Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 3" 115 173 230 346 4" 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 LUKIN VVILMINJ IVIUULL 30U/A01 OUTDOOR HORIZONTAL INSTALLATION Specifications The Double Check Backflow Prevention Assembly shall be certified to NSF /ANSI 372, ASSEO Listed 1015, and supplied with full port gate valves. The main body and access cover shall be 304L Stainless Steel, the seat ring and check valve shall be NORYLTIA' the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The checks shall be accessible for maintenance without removing the device from the line. The Double Check Backflow Prevention Assembly shall be a ZURN WILKINS Model 350AST. Zurn Industries, LLC I Wilkins Rev. H 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855 - 663 -9876, Fax 805 - 238 -5766 Date: 2/14 In Canada I Zurn Industries Limited Document No. BF- 350AST 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 Ph. 905 - 405 -8272, Fax 905 - 405 -1292 Patent No. 5,913,331 Product No. Model 350AST www.zurn.com Pagel of 2