Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
20160115 Approved Plans Portable 03212016
DEPT. OF LABOR & 44C;i` .. ok_S CONSTRUCTION EEC T ORY BUILT HOMES C,;0MLlVt= :. FWrj ACCZPTED NO 81.13JECT TO FIELD INSPcCTION 9 TRv"CI.T �GR VIOLATION OF RCW IS NOT "'CLL;OZD dMU�Lr�. =.i Ii'�rifi � _,..r... .. �� 1 •'f � ` � l Ci ALTERATIONS FROM BASE PLAN: 1. REMOVE FIRE RATING FROM INTERIOR CROSS WALL BETWEEN CLASSROOMS. 2. ADD ONE DOOR TO EACH CLASSROOM PER I REQUIREMENTS OF IBC 903.2.3 EXCEPTION 2 3. ADD (4) 6020 WINDOW AT GRID A 4. ADD (2) WINDOWS & CHANGE SIZE TO 6040 AT GRID C ,P ( 5. CHANGE ROOF OVERHANG TO 16" 6. ADD NARROW VISION LITE TO EXTERIOR DOORS 7. CHANGE EXTERIOR DOOR HARDWARE TO Zf PANIC/PULL y 0. CHANGE ROOF SNOW LOAD TO 30 PSF AN 9. CHANGE ROOF SLOPE TO 3 IN 12 9S 10.ADD (18) DUPLEX RECEPTACLES 11.MODIFY DAYLIGHT SENSORS AND SWITCHING 12.ADD VENTED SOFFIT 13.ADD OPTION FOR FIBER CEMENT LAP SIDING L 1.I SHEETINDEX SHT. NO. SHEET NAME Current Rev. Rev Issued By Checked By A 0.0 COVER SHEET KR A 0.1 GENERAL NOTES KR A 0.2 ENERGY CODE NOTES PROD. DESIGN MASTER PLAN SHEET KR A 1.0 FLOOR PLAN KR A 1.1 REFLECTED CEILING PLAN KR A 1.2 ROOF PLAN KR A 2.0 EXTERIOR ELEVATIONS 0.0 KR A 2.1 EXTERIOR ELEVATIONS KR A 3.0 FLOOR FINISH PLAN (NOT USED) (KCDA MODEL/ADDENDUM # 12 ) A 3.1 IFINISH NOTES KR A 3.2 ISCHEDULES DATE 3/9/16 KR A 3.3 DATA SCHEDULES KR A 4.0 INTERIOR ELEVATIONS (NOT USED) KR A5.0 _ DETAILS _ KR A 5.1 DETAILS (NOT USED) KR S1.0 FOUNDATION PLAN KR S2.0 FLOOR FRAMING PLAN KR S3.0 BUILDING SECTIONS KR S4.0 !FOUNDATION NOTES & DETAILS KR S4.1 7FOUNDATION DETAILS KR S4.2 FOUNDATION DETAILS KR S4.3 DETAILS KR,TATEof%NASa °r; FAS S4.4 ! DETAILS KR S4.5 DETAILS KR E 0.1 ELECTRICAL LEGEND & -NOTES KR E 1.0 ELECTRICAL PLAN KR AN E 2.0 LIGHTING PLAN KR -- E 3.0 ELEC. PANEL A & LOAD CALCS. KR M 0.1 HVAC NOTES & LEGEND KR M 1.0 HVAC PLAN KR M 2.0 HVAC ISOMETRIC KR ANN I DEPT, OF LABOR AND INDUSTRIES IEW SECTION APPROVED 3JEQT TO CODE FIELD INSPECTION A. RAS S�OF WASyl 21543 4V� F�S'SjONAL £rely REV. DESCRIPTION DATE BY REUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND SHEET COVER SHEET JOB K 2 64 CDA #12 DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING 00ADDERN BUILDING SYSTEMS PROD. DESIGN MASTER PLAN SHEET SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT MODERN BUILDING SYSTEMS INC. G 28'x 64' MODULAR CLASSROOM 0.0 WRITTEN AUTHORIZATION. TELEPHONE (503) 749 -4949 FAX: (503) 749-4950 (KCDA MODEL/ADDENDUM # 12 ) P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325 CHECK OUT OUR VJEB PAGE Mww.mDGembuk ingsystems.mm © MODERN BUILDING SYSTEMS, INC. 2016 ADDRESS _ DR TS DATE 3/9/16 GENERAL NOTES 1. THE TERM IBC SHALL APPLY TO THE CURRENT EDITION OF THE INTERNATIONAL BUILDING CODE AS AMENDED BY THE STATES OF OREGON AND WASHINGTON. FOR PROJECTS IN ALL OTHER STATES IT SHALL APPLY TO THE CURRENT EDITION OF THE UBC OR IBC AS ADOPTED BY THAT STATE. 2. ALL CONTROLS AND HARDWARE SHALL BE ACCESSIBLE TO PERSONS WITH DISABILITIES. 3. LOCAL JURISDICTION TO DETERMINE COMPLIANCE WITH CHAPTER 29 (WITH REGARD TO-ADJACENT FACILITIES) IN ACCORDANCE WITH THEIR CURRENTLY ADOPTED EDITION OF THE UBC OR IBC. 4. THIS SET OF PLANS PREPARED AND SUBMITTED FOR APPROVAL UNDER THE FOLLOWING CODES: BUILDING 2012 IBC/WAC 51 -50 MECHANICAL 2012 IMC/WAC 51 -52 PLUMBING 2012 UPC/WAC 51 -56 ENERGY 2012 WSEC/WAC 51 -11C ELECTRICAL 2014 NEC DESIGN CRITERIA GENERAL: CONSTRUCTION TYPE OCCUPANCY GROUP OCCUPANCYLOAD DISTANCE TO PROPERTY LINE OR ASSUMED PROPERTY LINE ELECTRICAL: ELECTRICAL SERVICE LOAD MECHANICAL: VENTILATION OCCUPANCY LOAD CLIMATE ZONE HEATING AIR - CONDITIONING PLUMBING: PLUMBING OCCUPANCY LOAD QUANTITY OF PLUMBING FIXTURES STRUCTURAL:SNOW LOAD FLOOR LIVE LOAD WIND LOAD SEISMIC VB (NON -SPRINKLERED) E 84 FRONT: 10' MIN. REAR: 10' MIN. LEFT: 10' MIN. RIGHT: 10' MIN. 200 AMP-1 PH. x45.7 kVA , 10. L - - - -j 58 4C /5B SPV /HP SPV /HP 42 EACH 0 L — I 8. 50 PSF Iw = 1.0 lambda= 1.0 110 MPH 3 SECOND GUST - EXP. B BEARING WALL SYSTEM: Ss = 1.500 Fa = 1.00 Sds = 1.000 OCCUPANCY CATEGORY II ?ATE OF WASHINGTON DEPT. OF LABOR AND IN[ le = 1.0 SEISMIC DESIGN CATEGORY D, SITE CLASS D FAS PLAN REVIEW SECTION APPROVED MAR 2 7 ZQi@ su ANL? N A. RAS�Lr -- W� Z�j z 21543 STERE�C ;r SIONAL Er REV. DESCRIPTION DATE BY I REUSE THIS DOCUMENT DOCUMENTS THIS DOCUMENT AND THE IDEAS AND M130ERN SHEET GENERAL NOTES JOB# 2 64 KCDA #12 DESIGNS INCORPORATED HEREIN ARE THE PROPERTYOFMODERNBUILDING BUILDING SYSTEMS PROD. DESIGN MASTER PLAN SHEET SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT BUILDING SYSTEMS INC. 28'x 64' MODULAR CLASSROOM O. 1 WRITTEN AUTHORIZATION. EMODERN TEPHONE: (503) 7494949 FAX (503) 749-4950 (KCDA MODEL /ADDENDUM #12) P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325 CHECK OUT OUR WEB PAGE modembumingsyslems.mm © MODERN BUILDING SYSTEMS, INC. 2016 ' ADDRESS DRw TS DATE 3/9/16 5,9 IN PLACE OF SKIRT RIM n FRONT ELEVATION 3/16" = 1' -0" n RIGHT END ELEVATION '-t3/16'= 1' -0" 1 t 9 Roof / Plate 8'- 1 1 /8" WINDOW TRIM - TYP. _ _Sub-Floor 0' -0" 0 - Grade -21- 6" STATE OF OF LABOR AND INDUSTRIES FAS PLAN REVIEW SECTION APPROVED MAR 2 SUBJECT TO CODE AND FIELD INSPECTION A, RAS,/_ �p�oF W H AS��`�l �tj r ,F z 21543 �V sRECISTER61 SI ONAL Er REV. DESCRIPTION DATE BY REUSE OUMENT DOCUMENTS THIS DOCUMENT AND THE IDEAS AND ��� SHEET EXTERIOR ELEVATIONS JOB 2 64 KCDA #12 DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING BUILDING SYSTEMS PROS. DESIGN MASTER PLAN SHEET SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY MODERN BUILDING SYSTEMS INC. p 28 X 64 MODULAR CLASSROOM ^ { OTHER USE OR PROJECT WITHOUT WRITTEN AUTHORIZATION. Tf1EPHDNE (SD3) 74x4948 FAX (503) 749-4950 (KCDA M O D E L/A D D E N D U M #12) L . O P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325 CHECK OUT OUR WEB PAGE modembuldingsyslems.wm © MODERN BUILDING SYSTEMS, INC. 2D16 ADDRESS DRW TS DATE 3/9/16 IN PLACE OF SKIRT RIM - TYP. , REAR ELEVATION 3/16'-'= 1' -0" A B C -- - - - - - - - - - - - - ------ 5,9 I n LEFT END ELEVATION 3/16" = 1' -0" Roof/ Plate 8' - 1 1 /8" TYP. INSIGNIA LOCATION MOD BATT W/ (2) ROWS OF 6d AT6 "O.C. Sub -Floor 0' - 0" 0 - Grade -2' - 611 Roof/ Plate 8' - 1 1 /8" Sub -Floor 0' -0" 0 - Grade _2'- 6" STATE OF FA SPLAN REVIEW SE TON APPROVED MAR 2.1 Z.Q15 AND =3 E'C15TERR� f ONAL REV. DESCRIPTION DATE BY REUSE OUMENT DOCUMENTS THIS DOCUMENT AND THE IDEAS 'ja �� SHEET EXTERIOR ELEVATIONS JOB 286 KCDA #12 AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING BUILDING SYSTEMS PROS. DESIGN MASTER PLAN SHEET # SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT MODERN BUILDING SYSTEMS INC. 28'x 64' MODULAR CLASSROOM ///��� ///��� w [] / ^ L WRITTEN AUTHORIZATION. TELEPHONE (503) 749 -4949 FAX (503) 749 -4950 P.O. BOX 110, (KCDA M O D E L/A D D E N D U M #12) . 9493 PORTER ROAD, AUMSVILLE, OR 97325 CHECK OUT OUR NN PAGE mode mbu6dingsyslems.mm ADDRESS DRW ©MODERN BUILDING SYSTEMS, INC. 2016 TS DATE 3/9/ 16 FLOOR CONSTRUCTION INTERIOR WALL CONSTRUCTION EXTERIOR NOTES FINISH: CARPET THROUGH -OUT BASE: 4" VINYL THRU -OUT UNDERLAYMENT:NONE SUBFLOOR: 23/32" APA RATED SHEATHING (ACTS AS 1 PERM MAX. VAPOR BARRIER) (ACTS AS AIR BARRIER) JOISTS: 2 x 8 DF #2 AT 16" O.C., DBL. 2 x 8 AT ENDS RIM JOISTS: 1 -1/2" x 7 -1/4" CONTIN. LAMINATED VENEER LUMBER (ESR -1387 & ESR -2913) OFFSET RIMS: 2 x 4 INSULATION: R -30 U (2 LAYERS R -15 FIBERGLASS BATTS) BOTTOM CLOSURE: FS -25 EXTERIOR WALL CONSTRUCTION PLATE HEIGHT: 8' -1 1/8" SIDING: 19/32" DURATEMP T1 -11 W/ 8" VERT. GROOVES OVER BARRIER WRAP OPTIONAL FIBER CEMENT LAP SIDING (8" EXPOSURE) OVER 30# FELT OR� 13. LBARRIERWRAP — — — — — — — — — — — — — — — J PROVIDE FULL - HEIGHT 2" x 2" GALV. FLASHING OVER DURATEMP SIDING & BEHIND CORNER TRIM AT ALL CORNERS SHEATHING: 5/8" TYPE 'X' GYP. SHEATHING PROVIDE MIN. 12" WIDE FULL - HEIGHT BARRIER WRAP OVER GYP. SHEATHING & BEHIND SIDING AT ALL CORNERS PROVIDE BARRIER WRAP OVER GYPSUM SHEATHING & UNDER SIDING AT LOW EDGE OF EXTERIOR WALLS ALL AROUND -MIN. 12" A.F.F. AND LIP 8" BELOW BOTTOM OF SIDING STUDS: 2 x 6 DF STUD GRADE AT 16" O.C. INSULATION: R -21 U (FIBERGLASS BATTS) HEADERS TO BE (2) 2x W/ MIN. R -10 INSULATION BETWEEN. SEE DOOF& WINDOW SCHEDULE FOR SIZE INTERIOR FINISH: 1/2" V.C. TACKBOARD OVER 5/8" TYPE'X' GYPSUM BOARD SHEATHING (ACTS AS 1 PERM MAX. VAPOR BARRIER) (ACTS AS AIR BARRIER) SKIRT: MATCH SIDING STUDS: 2 x 4 H STUD GRADE AT 16" O.C. (U. N. 0.) FULL - HEIGHT WALL W/ R -11 MINERAL WOOL BATT SOUND INSULATION INTERIOR FINISH: 1/2" V.C. TACKBOARD OVER 5/8" TYPE 'X' GYPSUM BOARD r- — — — — — — -- — — — — — — — — - L — — — — — — — — — — — — — — — - 1 CEILING NOTES CEILING HEIGHT: NOMINAL 8' -0" (U.N.O.) SUSPENDED T -GRID W/ ACOUSTIC TILE (REF: MFR'S INSTALLATION DATA) INSTALL SUSPENDED CEILING PER IBC, ASTM C635, C636,ESR -1308 AND 401 DATED 10109 ATTACH LIGHT FIXTURES TO CEILING GRID W/ (4) #6 x 1" STSM SCREWS ATTACH HVAC DIFFUSERS TO CEILING GRID W/ (4) #6 x 1" STSM SCREWS LIGHT FIXTURES SHALL BE INDEPENDENTLY SUPPORTED BY 12 GA. WIRES AT OPPOSITE CORNERS ROOF CONSTRUCTION FIBERGLASS COMP. SHINGLES OVER (2) LAYERS 15# FELT (MIN. CLASS B), (6) STAPLES ICE AND WATER SHIELD OR MOP MIN. 2' -0" INSIDE WALL LINE AT EAVES SHEATHING: 7/16" O.S.B. (24/16) (ACTS AS AIR BARRIER) FRAMING: 2 x 10 HF #2 AT 24" O.C. r BEAMS. (2) 1 -1/2" MURPHY 3100 Fb 2.0E x 24' L — (ESR_1387 & ESR - 2913)— — — — — — — — j 8 INSULATION: R-42 (CELLULOSE) W/ FS -25 (ACTS AS 1 PERM MAX. VAPOR BARRIER) r — — — - -- I L OVERHANG: 16'_ J 5. LROOF PITCH: 3 IN 17 9. RIDGE VENT r - - - - - - - - - - -� L SOFFIT: PERFORATED FIBER CEMENT) 12. CORNER BATTS: 1 x 4 FASCIA: 1 x 6 BARGE: 1 x 6 GUTTERS: 5" K -LINE (PREFINISHED) DOWNSPOUTS: 2" x 3" RECT. (PREFINISHED) STATE OFF WASHINGTON REVIEW SECTION IE` CTION AAPPROVED USTR MAR 2 1 Z016 SUBJECT T AND FIEL � wnt �lV g Wasy7^ z A ;r 21543 4� �,eSRFCI S T ERE�G1r S f ONAL Er REV. DESCRIPTION DATE BY REUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND MODERN SHEET FINISH NOTE S JOB# 2 64 KCDA #12 DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING BUILDING SYSTEMS PROD. DESIGN MASTER PLAN SHEET SYSTEMS INC. AND ARE NOT TO BE MODERN BUILDING SYSTEMS INC. 28'x 64' MODULAR CLASSROOM OTHER USE OR PROJECT WITHOUT OTHER SEOLEORIN TWITH UT WRITTEN AUTHORIZATION. TELEPHONE (503) 7494949 FAX (503) 749-4950 P.O. BOX (KCDA M O D E UAD D E N D U M #12) 3. 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325 CHECK OUT DURING SYSTEMS, PAGE- INC 2016 tlingsystems.com ©MODERN BUIRWEB INQ2015 ADDRESS DRW TS DATE 3/9/16 DOOR SCHEDULE — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Mark Width Height Thickness Swing Core Lite Size Lite Glass Face Door Finish Frame Type Frame Finish Throat R.O. Type Hdw Group Fire Rating Door Header U -Value Remarks 1 3'- 0" 6' - 8" 1 3/4" RHOS HM NRW CLR /TMP MTL PT HM PT 7 7/8" A 1 VINYL (2) 2 x 8 DF #2 22 0.3 2 3' - 0" 6'- 8" 1 3/4" LHOS HM NRW CLR / TMP MTL PT HM PT 7 7/8" A 1 CLR I (2) 2 x 8 DF #2 .22 THRESHOLD 3 3'- 0" 6'- 8" 1 3/4" LHOS HW NRW CLR / TMP MTL PT HM PT 7 7/8" 1 A 1 (2) 2 x 8 DF #2 .22 4 3'- 0" 1 6' - 8" 1 3/4" RHOS I HW NRW CLR / TMP I MTL PT HM PT 7 7/8" A 1 (2) 2 x 8 DF #2 .22 NOTES: 1. CAULK AND SEAL ALL EXTERIOR DOORS 2. ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT (U.N.O.) 3. ALL DOOR LEADS 4 -1/2" U.N.O. 4. ALL DOORS TO HAVE AN OPENING FORCE NOT TO EXCEED 5 POUNDS — — — — — — — — — — — — — — — — — — — — — — — — — — — — J 2,6,7 WINDOW SCHEDULE — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Mark Count Width Height Type Frame Glass SHGC U -VAL Air Leakage Ext. Trim Int. Trim Window Header Comments A 4 6'- 0" 4' - 0" XO VINYL DUAL/ LOW E /ARGON /SOLAR TINT/TMP 0.30 0.3 .18 CFM /SF 1x4 AO (2) 2 x 8 DF #2 CLOSER I B 4 6'- 0" 2'- 0" XO VINYL DUAL / LOW E / ARGON / SOLAR TINT 0.30 0.3 .18 CFM /SF 1x4 AO (2) 2 x 8 DF #2 DOOR BOTTOM I NOTES: 1. CAULK AND SEAL ALL EXTERIOR WINDOWS — — — — — — — — — — — 3,4 --- - - - - - - - - - - - HARDWARE SCHEDULE GROUP #1 I GROUP #2 GROUP #3 I GROUP #4 GROUP #5 GROUP #6 GROUP #7 1 -1/2 PAIR BUTTS I 1 -1/2 PAIR BUTTS ALUMINUM CO COLONY OAK HC HOLLOW CORE MTL PANIC /PULL LEVER/LEVER (PRIVACY) SOLID CORE VWS VINYL WRAP SURR. AFF ABOVE FIN. FLR. CS CAULK & SEAL (VON DUPRIN 22NL) I (A40S) NARROW (LITE) SF STOREFRONT WD WOOD BA BRONZE ANODIZED CLOSER I WALL STOP INS INSULATED PF PREFINISHED STN STAIN WLD WELDED WEATHER -STRIP BOTTOM VENT 2,7 FACTORY PRIMED KID KNOCK DOWN PT PAINT DOOR BOTTOM I TIMELY FRAME ( CEDAR FPT FIELD PAINTED STAT 1/2" MAX. ACCESSIBLE RIGHT HAND TMP TEMPERED CLR I CLEAR HB THRESHOLD LHR LEFT HAND REV. RHR RIGHT HAND REV. TTP TAPE, TEXTURE, PT OF WASHINGTON DEPT, OF LABOR AND IN[ FAS PLAN REVIEW SECTION APPROVE? MAR 212016 SUBJE T T CODE N I z 21543 ecrSTERE °tit 10 AL tir REV. DESCRIPTION DATE BY ABBREVIATIONS SHEET SCHEDULES �O 2 �64 KCDA #12 AL ALUMINUM CO COLONY OAK HC HOLLOW CORE MTL METAL SC SOLID CORE VWS VINYL WRAP SURR. AFF ABOVE FIN. FLR. CS CAULK & SEAL HM HOLLOW METAL NRW NARROW (LITE) SF STOREFRONT WD WOOD BA BRONZE ANODIZED FGL FIBERGLASS INS INSULATED PF PREFINISHED STN STAIN WLD WELDED BV BOTTOM VENT FP FACTORY PRIMED KID KNOCK DOWN PT PAINT TIM TIMELY FRAME CDR CEDAR FPT FIELD PAINTED LH LEFT HAND RH RIGHT HAND TMP TEMPERED CLR I CLEAR HB HARDBOARD LHR LEFT HAND REV. RHR RIGHT HAND REV. TTP TAPE, TEXTURE, PT OF WASHINGTON DEPT, OF LABOR AND IN[ FAS PLAN REVIEW SECTION APPROVE? MAR 212016 SUBJE T T CODE N I z 21543 ecrSTERE °tit 10 AL tir REV. DESCRIPTION DATE BY REUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND SHEET SCHEDULES �O 2 �64 KCDA #12 DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING SYSTEMS INC. AND ARE NOT TO BE 40AKIDERN BUILDING SYSTEMS PROD. DESIGN MASTER PLAN SHEET USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT MODERN BUILDING SYSTEMS INC. 28'x 64' MODULAR CLASSROOM 3.2 WRITTEN AUTHORIZATION. TELEPHDNE (503) 7493949 FAX. (503) 7493950 P.O. BOX 110, 9493 PORTER ROAD, AUMSAI I P. OR 97325 CHECK OUT OUR WEB PAGE , INC. 2016 ldirgrystems.com E) MODERN BUILDING SYSTEMS, INC. 2016 (KCDA M O D E VA D D E N D U M # 12 } ADDRESS DRW TS DATE 3/9/ 16 a 'a a i 3 C u 3 C L Q Q Z U n BUILDING SECTION U 3/8" = 1' -0" 1 5. Roof /_Plate 1 8' - 1 /8" I J EXTERIOR FINISH STUDS INSULATION INTERIOR FINISH Sub - Floor &--� 0' -0" 9 prade. )F W� : FAS PLAN REViE MAR 2 A `N% SUBJECT AND FIELD2 2164' v� 'ECisrER� °G�� ZONAL tir REV. DESCRIPTION DATE BY REUSE OF DOCUMENTS �� SHEET BUILDING SECTIONS KCDA #12 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING BUILDING SYSTEMS PROS. DESIGN MASTER PLAN ISHEET SYSTEMS INC.AND ARE NOT TO BE USED IN WHOLE OR IN TWITH UT OTHER USE OR PROJECT TWffHOUT MODERN BUILDING SYSTEMS INC. p �1 28 X 64 MODULAR CLASSROOM O RITTEN WRITTEN AUTHORIZATION. AUTHORIZATION. TELEPHONE (503) 7491949 FAX: (503) 749 -4950 P.O. BOX 110, (KCDA MODEL/ADDENDUM #12) . 9493 PORTER ROAD, AUMSIA —. OR 97325 CHECK BULD�SYSTE 2016�itlinOsystems.mm ADDRESS DRW TS DATE 3/9/16 r- — — — — — — — — — — — — — — — — — — — — — — — — — — -- _ TRIMLINE RIDGE VENT W/ ROOF SHEATHING — — — — — — — — — I COMP. RIDGE CAP OVER HOLD PLYWOOD & ROOFING 7/8" BACK FROM EA. SIDE OF RIDGE (2) LAYERS AT EXPOSED ROOFING I I 2 x 2 FILLER x 9" L. AT CONT. BUTYL STRIP 2 x 4 BLOCK W/ (2) 1 -1/2" DIA. VENT INSULATION W/ FS -25 ( I 24" O.C. W/ 12d EA. END I HOLES SCREENED PER RAFTER BAY I I RAFTERS CONNECTION SEE NDETA TER S 4.4 l'- 4" 1 2 x 4 DF #.2 W/ (4) 12d ° EACH END AT 24" O.C. I I FASCIA Z' - 6' ( I ( I I VENTED SOFFET I TRIM 2 x RIM JOIST W/ (3) 12d 2x INSULATION BLOCK I I END NAIL TO EA. RAFTER ( ACOUSTIC CEILING TILE I I INSULATION W/ 2 x 4 DF LEDGER / (5) 12d AT 4' -0" MIN. PLATE SPLICE FS -25 - RAFTER AND (3) 12d EA. END W/ (12) 12d EA. END - TYP. BEVEL BLOCK I I 2x INSULATION BLOCK AT BUTT JOINTS - TYP. Z METAL & BLOCKING AT SIDING 12d AT 24" O.C. I I (6) 5/8" DIA. M.B.'s OR THR'D RIDGE BEAM I JOINTS (WHERE OCCURS) 12d AT 6" O.C. 1 5,9,12 I ROD W/ NUTS AND WASHERS FIELD INSTALL ACOUSTIC l' -0" IN FROM END & EQ. SPACE CEILING THIS ROW ONLY STUD W/ INSULATION INTERIOR FINISH L— SIDING OVER SHEATHING -- — — — — — J L--------------------------- n TYP. SIDEWALL EAVE DETAIL ROOF MARRIAGE DETAIL SIDING OVER SHEATHING STUDS W/ INSULATION r� HOLD GYP. SHEATHING UP 1 -1/4" FROM EDGE OF SIDING LIP BARRIER WRAP 8" BELOW EDGE OF SIDING OFFSET RIM RIM JOIST REV.I DESCRIPTION INTERIOR FINISH 5/8" DIA. M.B.'S OR THR'D ROD W/ NUTS AND WASHERS AT 6' -0" O.C. & 2' -0 FROM END SUBFLOOR (ADJUST SPACING AS REQ'D SUBFLOOR I TO AVOID JOISTS) FLOOR JOIST X /-IX % 11111111111 � INSULATION W/ FS -25 INSULATION W1 SIMPSON LU26 SIMPSON LU26 HANGER FS -25 HANGER RIM JOIST n TYP. SIDEWALL FLOOR DETAIL DATE I BY REUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT WRITTEN AUTHORIZATION. n FLOOR MARRIAGE DETAIL U111 = 1' -01, GVERN SHEET DETAILS BUILDING SYSTEMS PROD. p DESIGN MASTER PLAN MODERN BUILDING SYSTEMS INC. 28' x 64' MODULAR CLASSROOM TELEPHONE (503) 749 -4949 FAX: (503) 749950 (K C DA M O D E L/A D D E N D U M#12) P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325 CHECK OUi OUR WEB PAGE w«w.modembuBdingsy iems.com © MODERN BUILDING SYSTEMS, INC. 2D16 ADDRESS :• STATE OF WASHINGT EV EW SECY ON APPRGVED USTRIE`. FAS PLAN R i'1AK '� t 2Q1ti SUBJECT TO CODE AND F1El D tiNSPECTION V OF WAS / V z 2,543 w ���S,RFCisreaE °Gti F SIONAL �r JOB# 2 64 KCDA #12 SHEET # S4.3 DRW TS LDATE 3/9/16 r- - - - - - - - - - - - - - - - - - - - - - - - - - - 1 DATE BY I REUSE THIS OF DOCUMENTS N TS THIS DOCUMENT AND THE IDEAS AND MODERN SHEET DETAILS 4SHEET NOTCH SIDING 84 RIM (3) 12d SCREWSHANK- 5,12 AT OUTLOOKERS OUTLOOKER TO RAFTER DESIGNS INCORPORATED HEREIN ARE PROD. DESIGN MASTER PLAN 1 -4 THE PROPERTY OF MODERN BUILDING BUILDING SYSTEMS Ze ROOFING ROOF SHEATHING 0 (3) 12d (3) 12d p SIMPSON CS18 SCREWSHANK 28' x 64' MODULAR CLASSROOM �.� W/ (5) N1O'S SUPPLY AIR DUCT WRITTEN AUTHORIZATION. EA. BARGE � END TYP. EA. CORNER 2 x 4 DF #2 SUB -BARGE RAFTERS I 5/8" GYP. BOARD LID ID TE 3/9/16 INSULATION VENTED SOFFET BLOCK 24 GA. SHT. METAL OR 2 x 6 DF #2 OUTLOOKER INSULATION W/ FS -25 GYP. BOARD (4) SIDES FLAT AT 48" O.C. VAPOR BARRIER 2 x 4 BLOCKING 1 x 2 TRIM STUDS W/ INSULATION 84 FS -25 ABOVE CEILING SIDING OVER SHEATHING ' INTERIOR SHEATHING I �— — — — — — — — — — — — — — — — — — — — — — — — — — — INSULATION IN EXTERIOR WALL AT PLENUM TO HAVE FS -25 VAPOR BARRIER n ENDWALL GABLE DETAIL 1 " = 1 ' -0" SIDING OVER SHEATHING STUDS W/ INSULATION 8d BOX NAILS AT 6" O.C. - v HOLD GYP. SHEA HING UP _ 1 -1/4" FROM EDGE OF SIDING INTERIOR FINISH SUBFLOOR LIP BARRIER WRAP 8" BELOW EDGE OF SIDING INSULATION W/ FS -25 OFFSET RIM 2x BLK'G AT 4' -0" O.C. RIM JOIST TYP. ENDWALL FLOOR DETAIL END RAFTER - TYP. SIMPSON CS18 W/ (4) N1O'S EACH END - TYP. RIDGE BEAM - TYP. PLAN VIEW AT CHORD TIE 2 x 3 STUDS FLAT AT 24" O.C. 5/8" GYP. BD. ON A SIDES AND FLOOR RETURN AIR GRILLE W/ FILTER (6 A. F. F. TO BOTT( IINDUS'f F 40 DN �f'opwASy1ti`f PLENUM DETAIL - 4 II = 0 II 1s ` � 2,543 w eCI STERf'�G1t S�ONAL Er REV. DESCRIPTION DATE BY I REUSE THIS OF DOCUMENTS N TS THIS DOCUMENT AND THE IDEAS AND MODERN SHEET DETAILS 4SHEET JO 2 64 KCDA #12 DESIGNS INCORPORATED HEREIN ARE PROD. DESIGN MASTER PLAN THE PROPERTY OF MODERN BUILDING BUILDING SYSTEMS SYSTEMSINC p USED INWHOLEORINPAOTTOBE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT MODERN BUILDING SYSTEMS INC. 28' x 64' MODULAR CLASSROOM �.� WRITTEN AUTHORIZATION. TELEPHONE (503) 749 -4949 FAX, 15031749 -4950 P.O. BOX (KC DA MODEL /ADDENDUM #12) 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325 CHECK OUT OUR WEB PAGE www. .da buBtli gIryy tl ms. © MODERN BUILDING SYSTEMS, INC. 2016 ADDRESS DRW Ts ID TE 3/9/16 r----------------- I Q I I I RAFTER w/ (4) 12d E.N. TO L.V.L. 8,9 I I RIDGE BEAM - ATTACH TO COL. W/ (4) 12d CS18 W/ (6) N10 -S _ L EACH END — — — — — (3) 12d AT 8" O: SIMPSON A34 N8'S EACH LEG 12d AT 6" O.C. STAGGERED 4x6DF #2 COLUMN - TYP. CS18 W/ (6) N1C EACH END FULL BEARING OR BLOCKS) F— — — — — — — — — — — — — — — — — — — - - � DATE BY B RAFTER W /(4) SHEET DETAILS �� 864 KCDA #12 12d E.N. TO L_V.L. LEDGER THIS THIS DOCUMENT AND THE IDEAS AND ( 4 ) 12d I RIDGE BEAM - ATTACH DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING AABUILDING SYSTEMS PROS. DESIGN MASTER PLAN SHEE # TO COL. W/ (2) 3/4" DIA. CARRIAGE BOLTS 2 x 4 x 30" BRACE AT OTHER E OTHER SEOLEORIN PROJECT UT ROUT MODERN BUILDING SYSTEMS INC 28'x 64' MODULAR CLASSROOM 1 st & 3rd RAFTER SIMPSON CS18 W/ (4) EA. SIDE OF COLUMN AUTHORIZATION. WRITTEN AUTHORIZATION. N10's EACH END RIDGE (KCDA MODEL/ADDENDUM #12) o, PORTER ROAD, RUMS I I F, OR 97325 CHECK OUT OUR WEB PAGE w .modembuBd_syslems.00m BEAM TO BRACE ADDRESS BOT. OF L.V.L. 3/16" x 6" x 9" L. © MODERN BUILDING SYSTEMS, INC- 2016 I — DATE 3/9/16 PLATE - WELD TO BEARING PLATE 3/4" x 3" x 9" STEEL SIMP. A34 W/ (2) #8 I BEARING PLATE PANHEAD SCREWS TO 2x PLATE TACK I 2x STUD (NO HILTI REQ'D) - co 3 "x3 "x3/16" r ' TUBE STEEL COLUMN i (ASTM A500 GRADE B c Fy = 46 KSI) - TYP. 21 WELD -TYP. I 2'- 8" MIN, 20 GA. x 2" x 12" (2) 12d I I STRAP W/ (12) N1O'S 3/4" x 3" x 9" STEEL I TOP OF BEARING PLATE W/ FIN -FLOOR 18,9 (4) 16d FULL BEARING (RIM OR BLOCKS) NOTE: OVERALL COLUMN HEIGHT = 9'-0 7/8" SIMP. A34 EA. SIDE W/ (2) (W/ PLATES) #8 PANHEAD SCREWS TOTAL NO. OF COLUMNS REQ'D = 2 L TO FLOOR SHEATHING - - - - - - - - - - - - - - - - - - - - - - - - - - � 7/8" DIA. HOLE - TYP. m. 0 0 TYP. 3/16" 0 SECTION A SCALE: 1" = 1' -0" PLAN VIEW SCALE: 1" = 1' -0" EP SQr��IONOP RDVEDUStR1E STATE�FFPSP AIDE EW =L CLIP MAR 2 ,1 'L�% JECT; O CODE SuB N'-c,1u AND FIEI D A R,, OF W A Sy END WALL COLUMN DETAIL n CENTER COLUMN DETAIL ��SSIONAL tirG�= REV. DESCRIPTION DATE BY REUSE OUMENTAN DOCUMENTS E � SHEET DETAILS �� 864 KCDA #12 THIS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING AABUILDING SYSTEMS PROS. DESIGN MASTER PLAN SHEE # SYSTEMS INC. AND ARE NOT TO BE OTHER E OTHER SEOLEORIN PROJECT UT ROUT MODERN BUILDING SYSTEMS INC 28'x 64' MODULAR CLASSROOM 4.� AUTHORIZATION. WRITTEN AUTHORIZATION. TELEPHONE (503) 749 -4909 FAX: (503) 749950 P.O. BOX 110, 9493 (KCDA MODEL/ADDENDUM #12) PORTER ROAD, RUMS I I F, OR 97325 CHECK OUT OUR WEB PAGE w .modembuBd_syslems.00m ADDRESS DRW © MODERN BUILDING SYSTEMS, INC- 2016 TS DATE 3/9/16 ELECTRICAL SYMBOL LEGEND -- ELECTRICAL NOTES I 2'x 4' FLUORESCENT LAY -IN FIXTURE (3) TUBE 32W I 1. CONDUIT SHALL BE ELECTRICAL METALLIC T8 W/ ELECT BALLAST (WEIGHT 23LBS.) TUBING AND METAL CLAD CABLE F32T81741 "COOL WHITE" LAMPS I DL -P = DAYLIGHT ZONE - PRIMARY 2. EXTERIOR RECEPTACLES SHALL BE WEATHER DL -S = DAYLIGHT ZONE - SECONDARY I RESISTANT TYPE W/ IN USE WEATHERPROOF COVER I I I ❑ WALL MOUNTED LIGHT FIXTURE +86" A.F.F. 3. FLUORESCENT LUMINAIRES WITH DOUBLE ENDED PC — PHOTOCELL I LAMPS THAT CAN BE SERVICED IN PLACE AND SHALL WP — WEATHERPROOF I HAVE AN INTERNAL OR EXTERNAL DISCONNECT E = EMERGENCY LIGHT W/ BATTERY BACK -UP I PER NEC 410.130G AUTOMATIC DAYLIGHT SENSING CONTROL ( 4. BUILDING SERVICE SHALL BE SERVED BY ONLY ONE OCCUPANCY SENSOR - CEILING MOUNTED SERVICE OR FEEDER PER NEC 225.30 & 230.2 I �y9 I 5. SERVICE OR FEEDER DISCONNECT SHALL BE 20 AMP DUPLEX RECEPTACLE +17" A.F.F. (U.N.O.) I INSTALLED PER NEC 230.70. FOR BUILDINGS IN GFI = GROUND FAULT INTERRUPTER THE STATE OF WASHINGTON SERVICE OR WP = IN USE WEATHERPROOF COVER FEEDER DISCONNECT SHALL BE INSTALLED PER WR = WATER RESISTANT RECEPTACLE I WAC 296 -4613-230 os I 6. PERMANENT MEANS OF LOCKING OUT $ OCCUPANCY SENSOR SWITCH W/ MANUAL ON I DISCONNECT TO MECHANICAL UNIT(S) SHALL nom MOMENTARY TOGGLE SWITCH I BE PROVIDED PER NEC 424.19 7. PERMANENT MEANS OF LOCKING OUT PP LIGHTING POWER PACK I DISCONNECT TO WATER HEATER(S) SHALL BE PROVIDED PER NEC 422.31(B) JO JUNCTION BOX I TO THERMOSTAT +48" A.F.F. TO TOP OF CONTROLS PHONE BOX - CONDUIT UP (RACEWAY ONLY) +17" A.F.F. (U.N.O.) I ELEC. PANEL NOTE: EMT CONDUIT SHALL NOT BE USED �o DISCONNECT I WITH UNFUSED CONDUCTORS INSIDE 200 AMP BUILDING LINES F AUDIO / VISUAL FIRE ALARM (RACEWAY ONLY) +86" TO CENTERLINE I 120/240V MIN. 2" SCH 40 PVC SINGLE PH. OR EMT CONDUIT W/ FIELD VERIFY AIC RATING M MANUAL PULL STATION (RACEWAY ONLY) +45" TO CENTERLINE I (3) 3/0 XHHW -CU REQUIREMENTS (1) #4 BARE CU I OV VISUAL ALARM (RACEWAY ONLY) +82" TO CENTERLINE ( (MIN. 10K AIC) BUILDING / SERVICE DISCONNECTING L — — — — — — — — — — — — ASHING�ONDEPT.Of LA80R ANO EDUSZRIE. MEANS MUST BE LOCATED ON OR — — — — — — — — J WITHIN 15 FEET OF THE BUILDING AND Of F gpI PNREV�EWSEOj�ONFFPR 11. MUST HAVE LABEL IDENTIFYING ITS #4 BARE CU TO FUNCTION AS THE BUILDING GROUND ROD DISCONNECT PER WAC 296 -46B -225 GROUNDING TO BE IN A ACCORDANCE 511��E�1T�COD ON rin FEE ,,CC .RAs ONE -LINE DIAGRAM TO NEC 250 COFWA Sly Y NO SCALE z 21543 v O��S 0 STERE�G1t S, 0 L S. REV. DESCRIPTION DATE BY �� SHEET ELECTRICAL LEGEND &NOTES JOB# 864 KCDA #12 REUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF MODERN BUILDING BUILDING SYSTEMS PROD. DESIGN MASTER PLAN SHEE # SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT WITHOUT MODERN BUILDING SYSTEMS INC 28'x 64' MODULAR CLASSROOM O . WRITTEN AUTHORIZATION. TELEPHONE (503) 7494949 FAX: (503) 749-4950 (KC DA M O D E VA D D E N D U M #12) P.O. BOX 110, M93 PORTER ROAD, AUMSVILLE, OR 97325 CHECK OUT OURV EPAGEw modemt ldingsyslems.wm DATE 3/9/16 ©MODERN BUILDING SYSTEMS, INC. ADDRESS DRW TS (2) C3 2. 2. "ELECTRICAL & ALARM FIXTURE TO BE MOVED i ( _ \ , _ , r - - -'j I WITH DOOR TO 2 ALTERNATE LOCATION I , - P. ( 3. I I ( I All 3. - - - - L J A7 A7 A7 i -� All All All ALTERNATE PANELA GFI/WPNVR ELEC. PANEL 120/240V / 200A LOCATION SINGLE PHASE W/ 2" A5 STUB -OUT A2,4 A k:@ A7 6,8 � E E � A11 I MECH [ A11 UNIT A A7� A11 8. A9 U U Al As CLASSROOM A CLASSROOM B A13 A9 Qzj j A13 A9 1 A9 A9 A9I A13 A13 A13 -- I € L - - - - - - - - - - -� ' - - - -- --y L - - - - - - - - - - - 4. 4. 10. l ADD (18) DUPLEX RECEPTACLES , n ELECTRICAL PLAN 3/16" = 1' -0" REV. DESCRIPTION DATE BY - REUSE THIS OF DOCUMENTS N TS �� SHEET ELECTRICAL PLAN THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE SYSTEM INC. N ARE BUILDING SYSTEMS PROS. DESIGN MASTER PLAN SYSTEMS INC. AND ARE NOT TO BE p USED IN WHOLE OR IN PART FOR ANY MODERN BUILDING SYSTEMS. INC. 28' x 64' MODULAR CLASSROOM OTHER USE OR PROJECT WITHOUT WRITTEN AUTHORIZATION. TELEPHONE (503) 749 -4949 FAX: (503) 7491950 (KC DA M O D E L/A D D E N D U M #12) P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325 CHECK OUT OUR VJEB PAGE: ww .modembubdingsyslems.mm ©MODERN BUILDING SYSTEMS, INC. 2016 ADDRESS GFI/WP/WR A5 .10,12 A14,16 MECH UNIT B STATE OF WAS N TON DEPT. OF LABOR AND INDUSTRIES FAS P ' A REVIEW SECTION APPROVE Al 3(9= AR 2 "12016 SUBJECT TO CODE -- -- 44 1 FIELD INSPECTION A. RAC, 1V� OF WASy7 21543 CIST E4F'�01r SIONAL Er 2864 KCDA #12 SHE T # 1.0 DRW TS DATE 3/9/16 0 C REV.1 DESCRIPTION r I I T 2 LIGHTING PLAN NOTES 3 OCCUPANCY SENSOR(S) IN EACH ROOM WILL BE WIRED TO CONTROL ALL LIGHT FIXTURES IN THAT ROOM. LIGHT WIRING AS SHOWN IS FOR GENERAL CONTROL CLARIFICATION ONLY. ACTUAL WIRING FOR CONTROLS (I.E.: SWITCHES, OCCUPANCY SENSORS AND DAYLIGHT SENSORS) SHALL BE PER CONTROL MANUFACTURER'S SPECIFICATIONS AND AS NECESSARY TO MEET THE CODE REQUIREMENTS FOR EACH CONTROL - - - _ _ _ _ _ _ _ _ Al ELECTRICAL &ALARM - - - -- - -- - - - - - - AND THE LIGHT FIXTURES CONNECTED TO IT. - -------------- - - - - - - - - - ".. F -� 1 A3 FIXTURES TO BE MOVE I WP /PC /E WITH DOOR TO ALTERNATE I LOCATION - TYP. ` 1 i WP/PC/E. 1 ` Al I I I I I� Al ti I /! , 1 -1-- FWASN ON�EEj 0C10NAPPRO EDUS�RIES STATEO;_.,.� RE4IEWS� ,Z 'Mb 1 WP /PC /E l I -- - - - - - - - - - - - - - - - - - - -Al l \ 23411 - - - - - - - - - - - - - - - - - - - - - - - - n LIGHTING PLAN 3/16" = 1' -0" DATE BY I �� SHEET LIGHTING PLAN REUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY INC'AN ARE BUILDING SYSTEMS PROS. DESIGN MASTER PLAN SYSTEMS INC. AND ARE NOT TO BE p OTHER SEOLEORIN TWITH UT MODERN BUILDING SYSTEMS INC 2S' x 64' MODULAR CLASSROOM OTHER USE OR PROJECT WITHOUT WRITTEN AUTHORIZATION. TELEPHONE: (503) 749-4949 FAX: (503) 74&-4950 (KC DA MODEL/ADDENDUM # 12 ) P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325 CHECK OUT OUR WEB PAGE. w.vw.modembuidingsysYemS.com ©MODERN BU9DWGSYSTEMS, INC. 2015 ADDRESS DRW TS TO CODE INSPECTION �A.R OF W A S Pti 2,543 w� 4,C/STERF.�G� w TONAL Er KCDA #12 SHE. # 2.0 DATE 3/9/16 I I I I I� -1-- FWASN ON�EEj 0C10NAPPRO EDUS�RIES STATEO;_.,.� RE4IEWS� ,Z 'Mb 1 WP /PC /E l I -- - - - - - - - - - - - - - - - - - - -Al l \ 23411 - - - - - - - - - - - - - - - - - - - - - - - - n LIGHTING PLAN 3/16" = 1' -0" DATE BY I �� SHEET LIGHTING PLAN REUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY INC'AN ARE BUILDING SYSTEMS PROS. DESIGN MASTER PLAN SYSTEMS INC. AND ARE NOT TO BE p OTHER SEOLEORIN TWITH UT MODERN BUILDING SYSTEMS INC 2S' x 64' MODULAR CLASSROOM OTHER USE OR PROJECT WITHOUT WRITTEN AUTHORIZATION. TELEPHONE: (503) 749-4949 FAX: (503) 74&-4950 (KC DA MODEL/ADDENDUM # 12 ) P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325 CHECK OUT OUR WEB PAGE. w.vw.modembuidingsysYemS.com ©MODERN BU9DWGSYSTEMS, INC. 2015 ADDRESS DRW TS TO CODE INSPECTION �A.R OF W A S Pti 2,543 w� 4,C/STERF.�G� w TONAL Er KCDA #12 SHE. # 2.0 DATE 3/9/16 r- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I I I MAIN DISTRIBUTION PANEL PANEL A PROJECT NO: 2864 KCDA #12 MOUNTING Recessed DATE: 3/9/16 i i I I Load Name Rating g Number Number of Poles A B Number of Poles Circuit Number Rating Load Name i i Lighting /Fan Classroom A 20 A Al 1 730 VA 6600 VA >, " • • 2 A2 60 A HVAC Classroom A i 10. i Lighting /Fan Classroom B 20 A A3 1 ,� r n - ,�, -• 717 VA 6600 VA — A4 — Exterior Receptacles 20 A A5 1 360 VA 3120 VA .�'. 2 A6 30 A HVAC Classroom A I i Receptacles Classroom A 20 A A7 1 1080 VA 3120 VA — A8 — — i Receptacle Classroom A 20 A A9 1 1260 VA 6600 VA � � 2 A10 60 A HVAC Classroom B 1080 VA 6600 VA 1 Receptacle — — Receptacle Classroom B 20 A A13 1 1260 VA 3120 VA `. � • 2 A14 i HVAC Classroom B A15 3120 VA — A16 i I A17 A18 A19 , � A20 I I I i A23 A24 TOTAL PANEL VA= 45367 VA 189 A =TOTAL PANEL AMPS BUSS SIZE I I i I I I i I ( i i i I i I i i i 120/240 Single MAIN BREAKER 200 A i ( ( I i i i i STATE OF WASHING RE SEW S �CT ON APPROVEDUSTRIES FAS PLAN I i AND 8 E D INSP C ION I W S _ z i 21543 W� �.F R£CISTERE� PHASE 1 ITEM CONNECTED LOAD DEMAND FACTOR CALCULATED LOAD LIGHTS 1447 VA 125.00 ° /D 18Q9 W SIGN CIRCUIT Q W RECEPTACLE 5040 VA 100.00% 5040 W DED. RECEPTACLE p W MOTORS 8 COMPRESSORS EXHAUST FAN 0 W LARGEST MOTOR p W HEATING & A/C (Per Mfg's Specs) TOTAL HEAT & A/C LOAD 38880 VA 100.00% 38880 W MISCELLANEOUS WATER HEATER 0 W CONNECTED LOAD CALCULATED LOAD TOTAL VA = 45367 VA TOTAL VA = 45729 VA TOTAL AMPS = 189 A TOTAL AMPS = 191 A ♦� L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J SS�ONAL E G REV. DESCRIPTION DATE BY REUSE OF DOCUMENTS THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN ARE THE PROPERTY INCiANFARENOTBUILDING SYSTEMS INC. AND ARE NOT TO BE OTHER SEOLEORINCTWn'H UT OTHER USE OR PROJECT WfTHOLTr WRITTEN AUTHORIZATION. �� BUILDING SYSTEMS MODERN BUILDING SYSTEMS. INC. TELEPHONE: (503) 749-4949 FAX (503) 749-4950 P.O. BOX 110, 9493 PORTER ROAD, AUMWI I E. OR 97325 ©F'MODERN BUILDING MTEM5, INCD2016 buNdingsyslems.com SHEET ELEC. PANEL A & LOAD CALCS. JOB# 864 KCDA #12 PROS. DESIGN MASTER PLAN 28'x 64' MODULAR CLASSROOM (KCDA MODEL (ADDENDUM #12) SHEE 3.0 ADDRESS DRW TS DATE 3/9/16 Classroom B 20 A A11 1 1080 VA 6600 VA — Al2 — — Receptacle Classroom B 20 A A13 1 1260 VA 3120 VA `. � • 2 A14 30 A HVAC Classroom B A15 3120 VA — A16 — — A17 A18 A19 , � A20 A23 A24 TOTAL PANEL VA= 45367 VA 189 A =TOTAL PANEL AMPS BUSS SIZE 200 A VOLTAGE 120/240 Single MAIN BREAKER 200 A PHASE 1 ITEM CONNECTED LOAD DEMAND FACTOR CALCULATED LOAD LIGHTS 1447 VA 125.00 ° /D 18Q9 W SIGN CIRCUIT Q W RECEPTACLE 5040 VA 100.00% 5040 W DED. RECEPTACLE p W MOTORS 8 COMPRESSORS EXHAUST FAN 0 W LARGEST MOTOR p W HEATING & A/C (Per Mfg's Specs) TOTAL HEAT & A/C LOAD 38880 VA 100.00% 38880 W MISCELLANEOUS WATER HEATER 0 W CONNECTED LOAD CALCULATED LOAD TOTAL VA = 45367 VA TOTAL VA = 45729 VA TOTAL AMPS = 189 A TOTAL AMPS = 191 A HVAC PLAN 3/16" = 1' -011 2'x 2' LAY -IN SUPPLY DIFFUSER " FLEX DUCT H B =M I" R/A 3RILLE R AND 1NuuZI I PROVED 1b DOE .CTION RAS 'sy�N�l o /- in 21543 O w� C1 ST ERA 1St f ONAL REV. DESCRIPTION DATE BY REUSE OF DOCUMETS N THIS DOCUMENT AND THE IDEAS AND SHEET HVAC PLAN J 2864 KCDA #12 THEI ROPERTYOFMODERN BUILDNG BUILDING SYSTEMS PROJ. DESIGN MASTER PLAN SHE # SYSTEMS INC. AND ARE NOT TO BE USED IN WHOLE OR IN PART FOR ANY OTHER USE OR PROJECT TWffHOUT MODERN BUILDING SYSTEMS INC. p 2S' x 64' MODULAR CLASSROOM 1 RITTEN WRITTEN AUTHORIZATION. AUTHORIZATION. TELEPHONE (503) 749 -4gdg FAX: (503) 7493950 P.O. BOX 110, 9493 (KCDA MODEUADDENDUM #12) .0 PORTER ROAD, AUMSVILLE, OR 97325 CHECK OUT OUR WEB PAGE w .mlembuAdingsyslems -wm © MODERN BUILDING SYSTEMS, INC. 2016 ADDRESS DRW TS J DATE 3/9/16