Loading...
20160284 ROW Permit 07112016�f 4 City of Yelm "4" PUBLIC WORKS OV 901 Rhoton Rd Yelm, WA 9 7 Phone: 360-458 - FAX: 360 - 458 -8417 Permit No. __am Q-U4 Application to Perform Work on Public Right of Way and /or Connect to Utilities r APPLICATION The undersigned hereby makes application to: Work in ROW to instal 127' of gas main. No as.12halt cut Trench- 10' in soft surface ROW job # 107051795 Location of work: 15624 Coats I agree to perform the work in strict compliance with Yelm Municipal Code, Chapter the special conditions enumerated herein and the attached conditions I have read and will adhere to the general provisions applicable to permits contained on this form. The Public Works Department (360- 458 -8406) must be contacted for inspection 24 hours before work commences or this permit will be void. The Underground Utilities Coordinating Council (1- 800 - 424 -5555) must be contacted two (2) working days before proceeding with any excavation associated with this permit. Name: Puget Sound Ener Potelco INC Address: 2711 Pacific Ave. S.E. ] m is WA 98506 Phone: 253 306 -2255 Proposed starting date of installation: Duration: I day Date: 2 Signature: PERMIT REQUIREMENTS For Official Use Only Fee $ Irp5 AO Issued Fee Received $* ,s P0 Application Approval Signature: Receipt Number 2 to 5 C7 To Be Completed By City Permission is hereby granted to perform the above described work subject to the general provisions contained on this form, and the following special conditions: e- V17 ` Gr A bond in the amount of is required to insure compliance with the above conditions, refundable upon satisfactory completion of work. No work shall be done under this permit until the party or parties to whom it is granted shall have communicated with and received instructions from: Remarks: First Inspection Date: Inspector Final Project Completion Approval: Date: Revised 03/09/2011 p City of Yelm PUBLIC WORKS 901 Rhoton Rd Yelm, WA 98 JIL70,00 Phone: 360-458 - FAX: 360- 458 -8417 Permit No. ki? p b dW Application to Perform Work on Public Right of Way and /or Connect to Utilities APPLICATION The undersigned hereby makes application to: Work in ROW to install 27' of gas main. No as.12halt cut Trench- 10' in soft surface ROW job # 107051795 Location of work: 15624 Coats Rd. . I agree to perform the work in strict compliance with Yelm Municipal Code, Chapter the special conditions enumerated herein and the attached conditions I have read and will adhere to the general provisions applicable to permits contained on this form. The Public Works Department (360- 458 -8406) must be contacted for inspection 24 hours before work commences or this permit will be void. The Underground Utilities Coordinating Council (1- 800 - 424 -5555) must be contacted two (2) working days before proceeding with any excavation associated with this permit. Name: Puget Sound Ener Potelco INC Address: 2711 Pacific Ave. S.E. Olympia. WA 9 506 Phone: 253 306 -2255 Proposed starting date of installation: Duration: l day Date: 2 Signature: PERMIT REQUIREMENTS I For Official Use Only Fee $ i 5 Au Issued Fee Received $* ,s P0 Application Approval Signature: Receipt Number 0002 (0 5 rj To Be Completed By City Permission is hereby granted to perform the above described work subject to the general provisions contained on this form, and the following special conditions: A bond in the amount of is required to insure compliance with the above conditions, refundable upon satisfactory completion of work. No work shall be done under this permit until the part), or parties to whom it is granted shall have communicated with and received instructions from: Remarks: First Inspection Date: Inspector Final Project Completion Approval: Date: Revised 03/09/2011 • \• \�"�• v Oo��yb rf��i Get' G Olt 1y2 10 CHANNELIZATION DEVICE SPACING MPH TAPER TANGENT 55/70 40 0, 80 35 /45 3 60 25/30 20 40 Notes: 1. All signs and spacing to conform to the MUTCD and Thurston County standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. 4. Sign size Gan be a minimum of 48" x 48" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 11' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m. P01 AREA UNDER CONSTRUC71ON �L3 \ \ '0 d • \ 4p. c 77 �0 9yF�� /' Hp L 6? 0 \ \\ mss'•: •. PUGET SOUND ENERGY Job #105080560 15624 Coates Rd SE, Thurston Co., WA June 13, 2016 Sheet 1 of 1 gregory.harwood@pse.com (425) 424 -6425 Puget Sound Energy Traffic Control Supervisor: Gregory Harwood Card No. 008997 Card Exp. 08/13/2019 g regory.harwood@ pse.COM (425124 -6425 LEGEND - 28' TRAFFIC CONE ® BORE PIT TRAFFIC FLOW TtFLAGGER WORK VEHICLE SIGN LOCATION WARNING FLAG Cl l f 58ell 44 (361 ) O RECD'' OPEF', : REF# : PAID 00236859 7/11/2016 CO TERM: 001 829505 BY'. TRAM: 33.0000 20160284 PUGET 15624 ROW TENDERED: F,PPLIED : 12:24 PM BUILD1 OtCRITS 25 SOUND ENERGY OLYMPIA COATES RD SE 125.00 CHECK 125.00- r-" O CHANGE: City of Yelm Community Development Department Building Division Phone: (360) 458 -8407 Fax: (360) 458 -3144 Applicant: Name: PUGET SOUND ENERGY OLYMPIA Address: 2711 PACIFIC AVE SE OLYMPIA WA 98506 Property Information: Site Address: 1 -RR7d r0ATF-R Rn SF Assessor Parcel No.: 22719230400 Contractor Information: Name: PUGET SOUND ENERGY OLYMPIA Address: 2711 PACIFIC AVE SE OLYMPIA WA 98506 Permit No.: 20160284 Issue Date: 7/11/2016 (Work must be completed within 180 days) Phone: 253 - 306 -2255 Owner: Subdivision: TYLER TERRACE Lot: 2 Contractor License No.: Expires Phone: 0 /00 /0000 Project Information: Project: UTILITY Description of Work: WORK IN ROW TO INSTALL 27 FT OF GAS MAIN. NO ASPHALT CUT. TRENCH 10 FT IN SOFT SURFACE ROW. JOB #107051795 Sq. Ft. per floor: First Heat Type (Electric, Gas, Other): Second Third Garage Basement Fees: Item RIGHT OF WAY Contractor PUGET SOUND ENERGY OLYMPIA TOTAL FEES: Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and re�trictionslo-f-r—eqprd. If applying as a contractor, I further certify that I am currently registered in +Yhe S at of Wash' gton. Signature Date �' I Firm 0��> C-- Fees $ 125.00 $ 125.00 OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: By: ✓Y 0 50' 100' INSTALL 2" = 27' JOINT 2" = 504' 2" CAP EOM/1MREBOX 534'NCL, 51 R' ( J'NCL, ( )R' O 0 R50' j I / _ i / `r 1gfl' f [i�? JOINT 2 "MPE -7,... . 504'@ 29'ECL TO 5IR' "@ l )'ECL TO ( )R' / ,�0 ,��• Lomtion Size N -S -E -W in Type Schad Qty each from Q / �y 'A' LOT 1 NO GAS 2 4 1 65 PRIMARY ENGR - GAS � O O / / )'WCL H 2" HVTT TE4N '55' y Y' POLYVALVElOPEN BEGIN JT MAIN Y ( )'NCL, ( )'WCL `T �jq 30'NCL, 29 -ECL /r 42'`1 SITE PLAN /S'a a� CROSSINGS (',0Nf)[ ]IT TAR[ F X -ING NO. Location GAS POWER Length ft Remarks (type of crossing) (primary, Feeder Secondary, SL Li hl, Gas onl etc., Size Type sched Qty each Lomtion Size N -S -E -W in Type Schad Qty each from !o X01 'A' LOT 1 NO GAS 2 D8120 1 65 PRIMARY PAw a Pm »M Una w Typlol EDin P W Cub Sid I. WWh mry nary per zees, _ Nuroeref WAW �- +I 1ZTypj' n4 Cmd,eL rs \ \\ F IGnd iZ Moo FielO ckal Sapendpn 3P Laelgn .1 11 s.inJ / 11 Mn 1ZMW' pyr pe,ror Wr«vPI is Mu 6- er 1Z Moo Send sird:p - - - S or tZ Moo Ser4 Sfedin9 Ikpei O.w GS -CaPpe 4on' Ovr POeer ,w Cmeemm' 4- Se,d Bee4kg r - Y Gu�.. TVa TEL` P'r/ry -J `Samntlay NOTES: Poeer Poxer 1. II III final 11 .111" contains racks gre- than D Inches in diameter, instiN 12 Inches compacted sand shading across the full width of the trench. If the final be Mill contain¢ rocks a inches in dfamelf or smaller, install 6lnches compacted send shading across the full width of the trench. 2. Rocks greater than 10 inches damerer are not permitted In the final leaekfill. 3. Sand badQnq is requiretl under PSE gas pipe. Bedding is not required for the full width of the tench; it shall extend from the Side of the trench nearest to where the ga s main /serdce is instilled to . nsmmum of 6 inches on the opposite side of the gas line. A. Ulihoss shall not be stacked over to gas lire In the trench. 5. If coat utllitlea will be included in Me trench, please contact PSE or local paver comps cry directly for cleararoe requiremmta. 6. Red. ad .barer. of 4 inches between paler and co mmunicatien, must have approval of the communications cempen lees • Attsmatves to full -width trench shadng require PSE appr -l. JOINT TRENCH DETAIL Primary 8 Secondary- Mainline Gas 8 Communications (NTS) 65 2" D8120 GREY PVC (ft) 2 = Total 2" PVC Plug Caps FITTER'S CHECKLIST (CHISOK ro00- CO-TION) ❑ sps-ad 3uei am PE P9e Par GOS 2450.1400 end 2460,1500 Q ReviexN ero rompMd wtl,YC¢nhu.Nen rwlr. C Raeordader si Inndas -lrs onontlur GO$ po GOS2500.1100. ❑ Cempead poM keulelun IrspcS¢n per GOS 2525.1200 ere 25251700. ❑ Lea lM vorR eru N e cYen eM eee roMean. F.-'. spos- Fennede Name (piae.dl compeer': P.- os 0.4 4580 W11 GENERAL NOTES - GAS (JOINT TRENCH): 1. Excavator to contact Utilities Underground Location Center (One Call) 48 hours prior to construction, to two working days prior to construction. 1- 800 - 424 -5555 2. Notify appropriate permitting agency prior to job start (see permit requirements). 3. Erosion and sediment control shall be per PSE Standard Practice 0150.3200 Techniques for Temporary Erosion and Sediment Control and any additional local jurisdiction requirements. 4. Any change in route, pipe size/type, tie-in method or additional main footage must be approved by the appropriate Engineer/Project Manager. 5. Complete "Exposed Pipe Condition Report" on all exposed existing Steel PSE Facilities. Check box on report for wire box (Test Lead) installation. 6. Pipeline Markers and Warning Signs shall be installed and recorded by the Contractor per PSE Gas Operating Standard 2525.2500. 7. To prevent accidental overpressure of adjoining systems, no two mains shall be connected, except as shown on this design, unless approved by the appropriate Engineer/Project Manager. B. System MAOP denoted by ISystemMAOP=60PSIG 9. Install Main Valves out of traffic where possible 10. Gauge (use Manometer for LP Systems) and monitor use of all stoppers and squeers to Insure adequate feed. 11. Install one pound Anode for every 1000' of locati g wire. Install Arcade and Test Lead Wires per PSE Gas Operating Standards 2525.1200 and 2525.2300. 12. If STW pipe involved, coordinate installation with CP Tech. N/A Cell # NIA 13, Purge Points and Pressure Taps shall be installed per PSE Gas Operating Standards 2525.3400 and PSE Gas Field Procedures Manual 0812 and 0813. 14. Mains and services shall be tested and purged per PSE Gas Operating Standards 2525.3300 and 2525.3400, 15. Unless otherwise noted: All pipes Installed in plat to be 2" MPE -7. All crossings to be Yellow 4" PVC. All Services to be 1-1/8" PE. / dents service stub location. �') denotes footage between fittings. 16. Customer to dig and backfll on pdvaW property or easement only. Trenches must conform to PSE Gas Operating Standards 2525.1500, 2525.1600 and 2525.1700. 17. Note all recordable footages, cealions and material changes on the se -built in red. 18. Upon completion of the project send the print copy, along with the completed Work order, listing crew 8 actual materials used to the appropriate deign group. 19. On site pre -con required before start of job. 20. At symbol: install natural gas main piping and fixtures. Size as indicated on tables and Work sketch (gas main is to parallel power system unless otherwise shown on work sketch). 21. Inclement weather conditions may muse delays in construction times and dates. Service Stub. NIA S- ica/Meler NIA Smvk:e/Mely NIA ServicsiMeler NA Ind Service NIA Ind MSA NIA 01¢ Rs9. / FT N/A HP SvrJMSA NIA Relocate NIA Retbement NIA Prelect Manager Contact Information Manager. Brian Hannon Cell PdO°e 425 95 -5526 "•e f "T Vicinity Map N.T.S. Owner / Developer Contact Info Mountain Tamace S. W.. 14730 Stale Route 507 YeM. WA 98507 ATTN: Mike KamOineM 380 -507 -0888 aR For contact. below dal 1-8a 8-CAU. PSE (225.5773) CALL (800) 4245555 2 BUSINESS DAYS BEFORE YOU DIG -LO M Red. bed' Yea ® No ❑ 'Fing ng Required' Ye. ® No D REAL ESTATE/EASEMENT REDT # (RW 408517) PERMIT THURSTON COUNTY REV# DATE x. DESCRIPTION FUNCTION CONTACT PHONE NO DATE - 15e ^i Ct.•x Afi St - PROJECT MGR Bnan Harmon 425 -5528 2/10116 2 Owner / Developer Contact Info Mountain Tamace S. W.. 14730 Stale Route 507 YeM. WA 98507 ATTN: Mike KamOineM 380 -507 -0888 aR For contact. below dal 1-8a 8-CAU. PSE (225.5773) CALL (800) 4245555 2 BUSINESS DAYS BEFORE YOU DIG -LO M Red. bed' Yea ® No ❑ 'Fing ng Required' Ye. ® No D REAL ESTATE/EASEMENT REDT # (RW 408517) PERMIT THURSTON COUNTY REV# DATE BY DESCRIPTION FUNCTION CONTACT PHONE NO DATE 3 - PROJECT MGR Bnan Harmon 425 -5528 2/10116 2 ENGR - GAS M. Cebenee M-395 -6625 612116 1 DRAWN BY M.CeWnaq 253 - 3968825 6/2116 CHECKED BY COUNTY THURSTON Emr Sect GAS 40 WK CTR CIONC APPROVED BY CP APPROVAL N/A N/A NIA 114 SEC SEC .W19- T17N -R02E OP MAP PI-AT 280.044 MAP 282.044 MAPPING JOINT FACILITIES ARRANGEMENTS UTILITIES COMCAST CENTURLY LINK RIGHT OF WAY PSE PLANNER CONTACT DAVEFARCEY WAYDE HOLMOUIar SHAWN GRENINGER WA PHONE# (M) 4135372s (360)764-5912 (253)476.8450 WA " PUGET Tyler Terrace SOUND 2- MPE -7 GAS MAIN EXTENSION - 11 S/F LOTS ENERGY 15824 Coat. Rd SE, Ydm, WA. 98597 DESIGNED BY PUGET SOUND ENERGY SAP Sup Order Nd 1010517 E EC Orde Nvm e SCAIE PAGE