20140275 05-19-2016-east-haven-villa-16s040-compression-test-concrete-report-c44138 Materials Testing & Consulting, Inc.
Ck-#echnk-al F'*mrering A{'1mtilhing•Swclnl In+prceirm 0 Mlrleflah TvAng 0 Fn%rirnnmrnlat C—rmll:¢
A'Akr rs -d L%%umnra.Vnm MY Y
East Haven Villa - 16SO40 - Compression Test: Concrete: Report#C44138
CLIENT Harrington Construction&Dev.,Inc. DATE 05/19/2016
PROJECT LOCATION 311 Cullens Road SE PERMIT#
Yehn WA
Inspection Information:
Inspection Date: 05/19/2016 Time Onsite: 08:00 am Weather Conditions: Partly cloudy
Inspection Performed: Compression Test:Concrete
Field Data (ASTM C-31):
Location of Placement: Main building perimeter footings,and center of building footings and stemwalls.
Sample Location: Center of builsing footings and stemwalls.
Contractor: arrington const. Subcontractor: a Supplier/Plant:Miles/206B
Qty Placed,Cu.Yd.: d3 of 40 Slump,Inches(ASTM C-143)or W/C Ratio:F4—] Concrete Temp,°F(ASTM C-1064): 67
Delivery Ticket#: 137917 Job Spec.Slump:E-1 Ambient Temp,°F:Ed
Truck#: M099 Air Content,%(ATSM C-231):Fa7 Min Temp,°F:❑
Batch Time: 08:22am Job Spec.Air:Fa I Max Temp,°F:❑
Sample Time: 10:00am
Mix#and Proportions: 1230OF/10 yd3 load
Cement,lbs.:13,780 Coarse Agg,lbs.: /8. 16,020 Admixture,oz./cwt:MBpoly99 7.240 oz
Flyash,lbs.:1940 Coarse Agg,lbs.: ea.3,480 Admixture,oz./cwt:
Water,gals.:k5l.5 Coarse Agg,lbs.: Admixture,oz./cwt:
Fine Agg,lbs.:115,220 Coarse Agg,lbs.: Admixture,oz./cwt:
Gallons of water were added 19 Prior to sampling
Sample Type & Compression Test Results:
Received 05/20/2016 Sample Set 1 of 1 Type of Compression Test: Concrete(ASTM C-39)
Lab Tests:
Test Total Sample Dim. Sample Comp. Break ASTM ASTM
New Log# Age Date of Test Load Area(Sq. Strength Tested By
(Days) (Lbs.) (In') In.) (PSI) Type C-617 C-1231
2360 1 7 05/26/2016 39,784 r 4.00 1 12.57 1 3,170 1 Lawrence Bell= ❑
2361 28 06/16/2016 55,895 4.00 12.57 4,450 Lawrence Bell 0 ❑
2362 28 06/16/2016 59,196 3.99 12.50 4,740 Lawrence Bell 0 ❑
2363 28 06/16/2016 57,995 3.99 12.50 4,640 Lawrence Bell 0 ❑
2364 F H I ❑ ❑
REQ'D ® D
Remarks:
Concrete was placed by boom pump truck see report#F73813 for more details.
++ +* r�+rR•�lr4rr...a..ra1.1„rr, 111.1
ms frmmnpvdk-4a pq Is filar%dm, .0 3401 • 1113 MuarlLls iuslq l C541MINly.Ins. All r1010 rsarrrN.
Corp-►rile ■ 777 Cbrysior Drive + Barlington, WA 918233 • Pbose 364.755.1990 * Frs 362.736.19RI
SV4 Region * 21 IS Black Lalm Hlud- S.W.• Olympia, w# 9$512 * phone 3401344777 * Fax 340,334.9779
NW Reolp■ * BIDS DuPOOL SUCCL, Suite 5 * 6ellisghom, WA 96225 v Phone 3d0.647.406L ' F¢r 3dd.fd7.81 11
Yisil our we hsile: www.m LC inc.Lcl
East Haven Villa-16SO40,0511912016,#C44138,Page I of 2
Materials Testing & Consulting, Inc.
GrOism nisal FAUwlcriM&Cunwllinp*9pwW In nmenlal CQmollkU
,+/ Apryp�err.�irrr�lftlP! Y
REPORTED BY:Sam Hyatt Jr. REVIEWED BY:Frank Pooler,Lab Manager
+r�rw. Ir�.+rR.�l.4rr...a..ra1.1„rr, rw.rrrrrerr�rd�r..
m�frmmmpvdk-4a pq Is filar%dm, .0 3401 • 1113 Nm4rlLIN iaNelq l C541MINly.IM. All rI010 rnarrrN.
Corparmle ■ 777 Ckrysior Drive + Barlington, WA 08233 • Phew 364.755.1990 * Frs 362.73S.19RI
SV4 Region * 21 IS Black Lllk* Hlv4- S.W.• Olympia, WA 9$512 * phone 340.134.4777 * Fax 340,334.9774
NW RC610m * BIDS DiAPOOL SUCCL, Suite 5 * 6ell1mghom, WA 96225 * Ph4me 3d0.647.406L ' F¢r 3dd.fF47.8111
Visit Du we hsile: wwyr.mic inc.mcl
East Haven Villa-16SO40,0511912016,#C44138,Page 2 of 2