20140164 12-09-2014-olympia-federal-yelm-branch-14s164-field-report-reinforcing-steel-report-f61901 Materials Testing & Consulting, Inc. Ck-#ec%ni-a1 1'rv,:imrer+ng A{'11nwNing•Swclnl Impeoirm*Mlrleflah TvAng*Fn%rirnnmrnlal C+rmll:¢ A'Atriwr -d Lyynrvnm Aim MY � Olympia Federal - Yelm Branch - 14S164 - Field Report: Reinforcing Steel: Report #F61901 CLIENT Olympia Federal Bank DATE 12/09/2014 PROJECT LOCATION 907 Yelm Avenue W PERMIT# 20140164 Yelm WA Inspection Information: Inspection Date: 12/09/2014 Time Onsite: 07:00 Weather Conditions: Overcast,62*17 Inspection Performed: Reinforcing Steel Report Profile: ® Any Deficiencies Noted ® Deficiencies Cleared Comments: Onsite to perform a visual inspection of reinforcing steel placement for 1'2"&1'5"Stem walls 3'6"x11"spread footings as follows: REINFORCING STEEL: Sheet(s):52.10 Detail(s): 1,2,3,8,6/S3.10;2,3/S3.11;5/S4.11;9/S3.10;5/S4.10;2/S4.11;6/S3.11 1/S4.11,8/S3.10,9/S3.10 Location(s):Continuous exterior&interior Stem walls @ A-F/2-9 and spread footings with plinths @ DA&D/5 Level(s):Foundation Plan Elevation(s):See Drawings Observed the placement of ASTM A615,grade 60 reinforcing steel into 1'2"&1'5"Stem walls and 3'6"x11"spread footings mark F3.5 on 8/S3.10 at the above mentioned locations. Reinforcing steel was of proper size,grade,lap,spacing,location,clearance,and secure prior to placement of concrete. Items noted to contractor for correction prior concrete placement: 1.Anchor rods hold down plate washer requires minimum clearance of edge form,contractor made corrections no further action required. 2.Per detail 2/S4.11 Contractor requires horizontal reinforcing each side of vertical pipe penetration,contractor added reinforcing per approved plan no further action required. Embeds:CB TYPE base by a Simpson Strong tie installed per 9/S3.10 Anchor bolts:Per detail 5/S4.11 Contractor installed 5/8"x12"all thread rods with(2)1/2"x3"x3"plate washers and double nut installed per plan.All plate anchorage of 5/8"diam.Bolts at 48"oc perschedule on 5/S4.10 and 1/S4.11 not installed at time of inspection,contractor to "wet set"into place please verify at concrete placement. Work performed,that was visually inspected was found to be in conformance with project plans dated 10-23-14 rev. 1. Images: +�+�+�*�r�+rR•�lr4rr...a..ra1.1„rr,*, m�frmmnpvdk-4a mpr hi p filar%dm, .0 3401 • 1113 Nn4rlLls iuslq l C541MIsly.Ins. All r1010 rsarrrN. Corp-►rile ■ 777 Cbr1slor Drive + 0arlington, W A 91823 • Phnse 364.75.9.1990 * Fax 362.736.19R@ SVV Region * 21 IS Black Lako Hlud- S.W.• Olympia, w# 9$512 * phone 340.534.4777 * Fax 340,334.9779 NW Reolom * BIDS DuPOOL SUCCL, Suite 5 * 6ell1mghom, WA 96225 * Phone 3dlft.647.406L ' F¢r $60."7.$1 11 Yisil our we hsile: www.m LC inc.Lll Olympia Federal-Yelm Branch-14S164,1210912014,#F61901,Page I of 2 Materials Testing & Consulting, Inc. frk-4e hniN1 F ralgi-rering 14('1mw4ing•Spmiel InlpKUm*Mn1erah TvAnp*Fnrirnnmenlal ConwollkM FugirnrdAn�.Surrm MY Y _ t UPLOADED: 12/09/2014 09:17:00 UPLOADED: 12/09/2014 u):16:k, REPORTED BY:Mike Dudley REVIEWED BY:Deane Ramsdell,Project Manager +r�rw��Ir�.+rR.�lr4rr...a..ra1.1„rr,e, mn frmmmpvdkVarmpr hi p filar%dm, .0 3401 • 1113 Nn4rlLIN iaNelq l C541MINly.Ins. All r1010 rnarrrN. Corp-►rile ■ 777 Cbr1slor Drive + 0arlington, W A 918233 • Pens 364.75.9.1990 * Fax 362.795.19R@ SV4 Region * 21 IS Black Lako f11u4. S.W.• 0IPmP12, WA 9$512 * phone 340.534.4777 * Fax 340,334.9779 NW Reolp■ * BIDS DIVPOOL SMCI, Suite 5 * &dlIIaIhoM. WA 96225 * Ph4ne 3dlft.647.406L ' F¢r $IiO.fd7.81 1 VisiI our we hsile: www.mkc inc.mcl Olympia Federal-Yelm Branch-14S164,1210912014,#F61901,Page 2 of 2