20140164 05-07-2015-olympia-federal-yelm-branch-14s164-proprietary-anchors-report-p12371 Materials Testing & Consulting, Inc.
Ck-#echni-al 1'rgimrer+ng A{'11nwNing•Swclnl Impeoirm 0 Hlrleflah TvAng 0 Fn%rirnnmrnlal C+rmll:¢
l:'��mmd Lyyornnra.Simv lfVP! Y
Olympia Federal - Yelm Branch - 14S164 - Proprietary Anchors: Report#P12371
CLIENT Olympia Federal Bank DATE 05/07/2015
PROJECT LOCATION 907 Yelm Avenue W PERMIT# 20140164
Yelm WA
Inspection Information:
Inspection Date: 05/07/2015 Time Onsite: 11:45 am Weather Conditions: 57*F,Partly Cloudy
Inspection Performed: Proprietary Anchors
Field Data:
Base Material:
®Concrete ®Un-cracked
Thickness in inches: 16 Specified Compressive Strength in psi: 2500
Hole Data in inches:
Depth: 5+ Edge Distance: N/a End Distance: /a Diameter: FA Spacing: 48
®Clean O Drilled O Cored
Mechanical Anchor Data:
Type:
Length in inches: 0 Diameter in inches: 0 Torque(Ft.lbs.): 0 ❑ Setting Tool Present
Adhesive Anchor Data:
Product Name: ISimpson ET-HP Batch#:k69T594T
Location:lBearing Wall @ Gridlines E/3.5-8 Exp.Date/Shelf Life: 12/10/16
Number of anchors:0 Anchor Length in Inches:® Anchor Diameter in Inches: 5/8
N Anchors installed in accordance with manufacturer's instructions,specifications,and corresponding evalution report(ER-3372)
Reason for Inspection:
Shown on plans or specs ❑ Intentionally omitted during original placement
❑ Re-inspection* ❑ Needs Engineer's review and acceptance*
®Threaded Rod ®Holes properly cleaned prior to epoxy installation
Remarks:
Sheet(s):51.11,S2.10,53.11
Location(s):Bearing Wall @ Gridlines E/3.5-8
Elevation(s):Finish Grade
Detail(s):General Notes on S1.1 1,3/S3.10,3/S3.11
M.T.0 on site,as requested,for inspection of the anchor type noted above.
Observed the contractor drill holes,blow holes clean with compressed air(90 p.s.i),brush holes,and then blow holes clean again with
compressed air.The adhesive/anchor was then installed per the manufacturer's printed installation instructions(MPII)and ICC ESR-3372.
Epoxy was completed by certified installer,no certified documentation was present at job site.
To the best of my knowledge,all work was performed in conformance with the manufacturer's printed installation instructions/ESR and
project plans dated 7-14-14(Rev. 1).Contractor(Mike,Andy Johnson&Company Inc)notified of the results.
++ +* r�+rR•�l.4rr...a..ra1.1„rr,� M.�.rr,.,olo.r,aK., w t.y„r,rra.rl.,r,..r.a,.lr, rw.rrrr"urt%r.. a.1
m�ftmmmppdOarmpr Is filar%im, .0 3401 • 1113 MuarlLIN Tuelq l C541MINly.Ins. All rlObo rnarrrN.
Corp-►rile ■ 777 Cbr1slor Drive * 0arlington, W A 91823 • Pbnse 364.75.9.1990 * Fax 362.736.19R@
SVV Region * 21 IS Black Lako Hlud- S.W.• Olympia, w# 9$512 * phone 340.534.4777 * FAX 340,334.9779
NW Reolp■ * BIDS DilPOOL SMCI, Suite 5 * &dlIIaghom, WA 96225 * Ph4me 3dlft.647.406L ' F¢r $IiO.fd7.8111
Visit our we hsile: www.mic inc.MC
Olympia Federal-Yelm Branch-14S164,05107/2015,#P12371,Page I of 2
Materials Testing & Consulting, Inc. M
frk-4e hniN1 F rolgi-rering 14('1mw4ing•Spmiel In9pK0m*Mn1erah TvAnp*Fnrirnnmenlal ConwollkM
FugirtrrdAn�.Simv MY
Images:
ism
.. 7
L'.
UPLOADED: 05/07/2015 14:40:00 UPLOADED:05/07/2015 14:41:00
Anchoring Adhevsive 5/8"(36 kip)All-Thread
Simpson ET-HP 8"Long
MINIMUM
i'
UPLOADED: 05/07/2015 14:41:00 UPLOADED: 05/07/2015 14:41:00
Finish Product Plate Joint
1 ft. spacing as required
y;
FIL Irr
M�' f
�(d.'
UPLOADED: 05/07/2015 14:42:00
Plan
REPORTED BY:Ben Erskine REVIEWED BY:Deane Ramsdell,Project Manager
+r�rw. Ir�.+rR.�lr4rr...a..ra1.1„rr,e M.�.rr,.,olo..,aK., w t.y„r,rr�a.rl.,r,..r.a,.lr,�.rr�r.rw.rrrrrerr�rd�r..
mn frmmnpvdk,4a mpr Is p filar%dm, .0 3401 • 1113 MuarlLIN iaNelq l C541MINly.IM. All r1010 rnarrrN.
Corpa►rsle ■ 777 Cbr1slor Drive + 0arlington, W A 918233 • Pens 364.75.9.1990 * Fax 362.795.19R@
SV4 Region * 21 IS Black Lako f11u4. S.W.• 0IPmp12, WA 9$512 * phone 340.5344777 * Fax 340,334.9779
NW Reolp■ * BIDS DIVPOOL SMCI, Suite 5 * &dlIIaIhoM. WA 96225 * Ph4lne 3dlft.647.406L ' F¢r 3613.647.8111
Visit our we hsile: www.mkc inc=
Olympia Federal-Yelm Branch-14S164,0510712015,#1`12371,Page 2 of 2