2014017912-18-2014-st -columban-church-addition-14s170-field-report-concrete-report-f62115 Materials Testing & Consulting, Inc.
Ck-#ec%ni-a1 F'rv,:imrcr+ng A{'1mkIMing•Swclnl In+prceirm 0 Mlrleflah TvAng 0 Fn%-irnnmrnlat C+rmll:¢
I:'Akr rs -d L%%mmnm.Vnm lfVP!
St. Columban Church Addition - 14S170 - Field Report: Concrete: Report #F62115
CLIENT St. Columban Catholic Church DATE 12/18/2014
PROJECT LOCATION 506 1 st Street S PERMIT# 20140179
Yehn WA 98597
Inspection Information:
Inspection Date: 12/18/2014 Time Onsite: 07:30AM Weather Conditions: Cloudy 39 degrees F
Inspection Performed: Concrete
Comments:
Reinforcing Steel:
Sheet:50.01,50.02,52.01,54.01
Details:13,D,L/54.01
Location:Perimeter footings and(4)exterior plinths grids 1-4/A-D
Level:Ground
Elevation:Foundation
Observed the placement of ASTM A615,grade 60 reinforcing steel at the above mentioned locations.
Reinforcing steel was of proper size,grade,lap,spacing,location,clearance,and secure prior to placement of concrete.
Embeds:N/A
Anchor bolts:N/A
Work performed,that was visually inspected was found to be in conformance with project plans dated 10-30-14 revision 1.
Concrete placement:
Sheet:50.01,50.02,52.01,54.01
Details:13,D,L/54.01
Location:Perimeter footings and(4)exterior plinths grids 1-4/A-D
Level:Ground
Elevation:Foundation
Observed the placement of 21 cyds of Holroyd concrete mix design#5551F25 at the location noted above.
Sampled and tested concrete for slump,temperature,and cylinder strength testing.One set of 5-4x8 cylinders were cast for compressive
strength test specimens,please reference report#C38526 for data.
Concrete was placed by boom pump and mechanically consolidated by electrically powered high cycle vibrator during placement.
Work performed,that was visually inspected was found to be in conformance with project plans dated 10-30-14 revision 1.
Images:
+�+�+*�r�+rR•�lr4rr...a..ra1.1„rr,�,M.�.rr,.,olo.r,aK.,.w rrrt.y„nrr•a.rl.,r,,..r.a,.lr,�.rr�r.r w.rrrrrerr�rd�r..�a.1,rlr„t,lr.�..w..�-.a..-a.�..,w.�•-
m�frmmnpvdk-4a mpr hi p filar%dm, .0 3401 • 1113 MnarlLls iuslq l C541MIsly.Ins. All r1010 rsarrrN.
Corp-►rile ■ 777 Cbr1slor Drive + 0arlington, W A 918233 • Phnse 364.75.9.1990 * Fax 362.736.19R@
SVV Region * 21 IS Black Lako Hlud- S.W.• Olympia, w# 9$512 * phone 340.534.4777 * Fax 340,334.9779
NW Reolom * BIDS DuPOOL SUCCL, Suite 5 * 6ell1mghom, WA 96225 * Phone 3dlft.647.406L ' F¢r $60."7.$1 11
Visit our we hsile: www.m LC inc.Lll
St.Columban Church Addition-14S170,1211812014,#F62115,Page I oft
Materials Testing & Consulting, Inc.
fpt,4rthniN1 F ralgi-rering 14('1mw4ing•Spmiel InlpK0m 0 Mn1erah TvAnp 0 Fnrirnnmenlal CarealliM
EmgirnrdAn�.rbi r MY Y
t wN
UPLOADED: 12/18/2014 11:54:00 UPLOADED: 12/18/2014 11:55:00
REPORTED BY:Mike Allen REVIEWED BY:Doug DeVries,Project Manager
+r�rw��Ir�.+rR.�lr4rr...a..ra1.1„rr,e,
mn frmmnpvdkOa mpr Is ^filar%dm, .0 3401 • 111] MnarlLIN ianlq l C541MINly.Ins. All r1010 rnarrrN.
Corp-►rile ■ 777 Cbr1slor Drive + 0arlington, W A 918233 • Pens 3d4-755-1990 * Fax 362.795.19R@
8V4 Region * 21 IS Black Lako H1u4- S.W.• Ol mpla, WA 9$512 * phone 340.534.4777 * FAX 340,334.9774
NW Reolp■ * BIDS Di1POOL SMCI, Suite 5 * &dlIIaghom, WA 96225 * Phone 3dl}.647.406L ' F¢r $ISd.fd7.8111
Visil Dur wehsiw www.mic inc.Lcl
St.Columban Church Addition-14S170,1211812014,#F62115,Page 2 oft