Loading...
20140179 12-18-2014-st -columban-church-addition-14s170-compression-test-concrete-report-c38526 Materials Testing & Consulting, Inc. Ck-#ectlni-al F'rv,:imrcr+ng A{'1mkIMing•Swclnl In+prceirm 0 Mlrleflab TvAng 0 Fn%-irnnmrnlat C—rmll:¢ I:'Akr rs -d L%%mmnm.Vnm lfVP! + St. Columban Church Addition - 14S170 - Compression Test: Concrete: Report #C38526 CLIENT St. Columban Catholic Church DATE 12/18/2014 PROJECT LOCATION 506 1 st Street S PERMIT# 20140179 Yehn WA 98597 Inspection Information: Inspection Date: 12/18/2014 Time Onsite: 07:30 AM Weather Conditions: Cloudy 39 degrees F Inspection Performed: Compression Test:Concrete Field Data (ASTM C-31): Location of Placement: Perimeter footings and(4)exterior plinths grids 1-4/A-D Sample Location: Footings gridlines 3.2/D Contractor:[Andy Johnson and Co Subcontractor: Supplier/Plant: olro d/5 Qty Placed,Cu.Yd.: 11/21 Slump,Inches(ASTM C-143)or W/C Ratio: 44 Concrete Temp,°F(ASTM C-1064): 61 Delivery Ticket#: 74806 Job Spec.Slump: 4+-1 Ambient Temp,°F: 39 Truck#: 396 Air Content,%(ATSM C-231): n/a Min Temp,°F:❑ Batch Time: 7;3p Job Spec.Air:F-1 Max Temp,°F: Sample Time: 8:21 Mix#and Proportions: 5551F25/1CYD Cement,lbs.: 88 Coarse Agg,lbs.: /8-1650 Admixture,ozJcwt: Flyash,lbs.:1130 Coarse Agg,lbs.: /8-250 Admixture,ozJcwt: Water,gals.: 1 Coarse Agg,lbs.: Admixture,ozJcwt: Fine Agg,lbs.:11375 Coarse Agg,lbs.: Admixture,ozJcwt: Gallons of water were added N Prior to sampling Sample Type & Compression Test Results: Received 12/19/2014 Sample Set 1 of 1 Type of Compression Test: Concrete(ASTM C-39) Lab Tests: Test Total Sample Dim. Sample Comp. Break ASTM ASTM New Log# Age Date of Test Load Area(Sq. Strength Tested By (Days) (Lbs.) (In') In.) (PSI) Type C-617 C-1231 3078 1 8 1 12/26/2014 52,136 F 4.01 12.63 4,130 Frank Pooler 0 ❑ 3079 28 I 01/15/2015 80,883 4.00 12.57 6,440 Frank Pooler 0 ❑ 3080 28 01/15/2015 79,664 4.01 12.63 6,310 Frank Pooler 0 ❑ 3081 28 01/15/2015 81,210 4.00 12.57 6,460 Frank Pooler 0 ❑ 3082 HOL ❑ ❑ REQ'D ® 2500 Remarks: Concrete placed by boom pump and mechanically consolidated with high-cycle vibrator during placement.Reference report#F62115. REPORTED BY:Mike Allen REVIEWED BY:Sam Hyatt,Lab Manager ++ +* r�+rR•�lr4rr...a..ra1.1„rr, rw.rrrrrerr�rd�r.. - mn frmmnpvdOa pqO Is filar%dm, .0 3401 • 1113 Nn4rlLls iuslq l[541Wsly.Ins. All rlObo rsarrrN. Corp-►rile ■ 777 Cbr1slor Drive + 0arlington, W A 918233 • Pbose 364.755.1990 * Fax 362.736.19R@ SV4 Region * 21 IS Black Lako Hlud- S.W.• Olympia, WA 9$512 * phone 3401344777 * Fax 340,334.9779 NW Reolp■ * BIDS 1?1jp00L SUCCL, Suite 5 * 6elllrQhom, WA 96 225 * Phone 3d0.647.406L ' F¢r $Ii0.f47.81 11 Visit our we hsile: www.m LC inc.Lll St.Columban Church Addition-14S170,12/18/2014,#C38526,Page I of]