20150117 Approved Plan Set 11042015,SITE PL.AI\.,' a VICINITY MAP DENOTES EXISTING BL DGS P -HASE- ���\� DENOTES NEW BLDG'S A F I, J — THIS r�ERMr DESIGNATION -- TYP. GENERAL NOTES AALL WIRING SHALL CONFORM TO NFPA 70 N.E.C. 22. THE EXACT LOCATION OF ALL WIRING AND DEVICES SHALL BE DETERMINED IN THE FIELD. L3. AUDIBILITY SHALL BE MAINTAINED DURING ALARM CONDITION UNTIL MANUALLY SILENCED AT THE BLDG FIRE ALARM CONTROL PANEL AT A LEVEL OF 75 DECIBELS IN RESIDENTIAL AREAS, A MINIMUM OF 60 DECIBLES IN OTHER AREAS AND A MINIMUM OF 15 DECIBELS ABOVE AMBIENT SOUND LEVELS. ZL\ ALL CIRCUITS TO INITIATING AND INDICATING DEVICES SHALL BE ELECTRICALLY SUPERVISED FOR OPENS, SHORTS, AND GROUNDS. 5\� ALL CONTROL EQUIPMENT SHALL BE INSTALLED IN BUILDER SUPPLIED HEATED LOCATION. r 6. THE LOCATION OF THE CIRCUIT BREAKERS FOR EACH FIRE ALARM CONTROL AND POWER SUPPLY SHALL BE PERMANENTLY LABELED AT EACH CONTROL. U FIRE ALARM CONTROL PANEL SHALL HAVE A SYSTEM SMOKE DETECTOR MOUNTED DIRECTLY ABOVE CONTROL AND WIRED INTO THE BLDG FIRE ALARM SYSTEM AS REQUIRED. L8\ a\ THE FIRE ALARM CONTROL ROOM SHALL BE LABELED 'FIRE ALARM CONTROL INSIDE' AS REQUIRED. SYSTEM SHALL REPORT TO A LOCAL UL LISTED CENTRAL STATION, SEPARATE SIGNALS FOR FIRE ALARM, WATERFLOW, TROUBLE AND SUPERVISORY. 10. ALL SPRINKLER CONTROL SWITCHES ARE PROVIDED AND INSTALLED ON PIPING BY OTHERS AND WIRED BY I.C.S., INC. 11. ALL STROBES WITHIN LINE OF SIGHT OF EACH OTHER SHALL HAVE THEIR FLASH RATES SYNCHRONIZED. n12. ALL DEVICES WITH E.O.L. DEVICES SHALL BE TAGGED AND OR LABELED AS SUCH. 13. WALL MOUNTED STROBES IN HEARING IMPAIRED UNIT BEDROOMS SHALL BE PLACED AT 24" FROM TOP OF DEVICE TO FINISHED CEILING, ALL OTHERS SHALL BE PLACED AT 80" FROM BOTTOM OF DEVICE TO FINISHED FLOOR. 14. PULL STATIONS SHALL BE MOUNTED AT A HEIGHT OF 42" TO 48" ABOVE FINISHED FLOOR LEVEL AND SHALL BE RED IN COLOR. 15 EACH BLDG SHALL BE EQUIPPED WITH AN OUTSIDE WEATHERPROOF BELL & STROBE. BELL STROBE SHALL BE MOUNTED NO LESS THAN 9 FEET ABOVE GRADE AND SHALL BE VISIBLE TO BUILDING APPROACH BY EMERGENCY VEHICLES. 'FAGP O 0 lJ v Cb CD 0_X A C FIRE ALARM CONTROL PANEL SIGNAL CIRCUIT POWER SUPPLY SYSTEM SMOKE DETECTOR MANUAL PULL ALARM STATION FIRE ALARM BELL AND STROBE (weatherproof) LOW FREQUENCY SOUNDER LOW FREQUENCY SOUNDER STROBE MINI -ALARM STROBE WATERFLOW ALARM SWITCH SPRINKLER VALVE TAMPER SWITCH 2 CONDUCTOR —14 AWG CABLE 2 CONDUCTOR —16 AWG CABLE 2 CONDUCTOR —18 AWG CABLE END OF LINE SUPERVISORY RESISTOR LED IN I't FOR OFF SITE COMMUNITION CON STRUCTIO TYPE: V -B WITH NFPA 13R FIRE SPRINKLERS CODE COMPLIANCE: 2007 NFPA 72 PROTECTED PREMISES FIRE ALARM / REMOTE STATION 2009 IFC SECT 907 2009 IBC SECT 907 OCCUPANCY: R -2 (APARTMENTS) B (OFFICE) SITE ADDRESS: 10520 CREEK STREET S.E. YELM, WASHINGTON PARCEL NO: 64303400400 64303400501 64303400502 INTERCEPT CONTROL SYSTEMS, INC, P O Box 30 - Maple Vallley, WA 98038 � (253) 8384400 , Fax (253) 8384857. ,. Townzen & Associates N Plan Approval The plans submitted for review are approved in accordance with local and state applicable standards. This approval does not relieve the applicant of the responsibility of compliance with the applicable codes. ❑ Approved with comments Approved as submitted zes Date: 0110 5, Action or Response for Fire Alarm Equipment Sound All Olspatd, Sound Call Cenual Call Service Recall sound Supervisory Close 0 P Operate all Operate Audibles rite Signal at Station and Tech Elevator Signal at Firedoors Smc!ce Pressurizatio Depanmenl FACP Premise f Ate Dampers n Fans Water Flow X X X X X Valve X X X X /� Tamper C aj Smoke X X X X X E Detector CL Cr Manual Pull X X X X I X w Switch a; Heat X X X X X 0 CL L Duct Smoke X X X X LL Detector Ground X X X X Fault Not all equipment used in all buildin s CON STRUCTIO TYPE: V -B WITH NFPA 13R FIRE SPRINKLERS CODE COMPLIANCE: 2007 NFPA 72 PROTECTED PREMISES FIRE ALARM / REMOTE STATION 2009 IFC SECT 907 2009 IBC SECT 907 OCCUPANCY: R -2 (APARTMENTS) B (OFFICE) SITE ADDRESS: 10520 CREEK STREET S.E. YELM, WASHINGTON PARCEL NO: 64303400400 64303400501 64303400502 INTERCEPT CONTROL SYSTEMS, INC, P O Box 30 - Maple Vallley, WA 98038 � (253) 8384400 , Fax (253) 8384857. ,. Townzen & Associates N Plan Approval The plans submitted for review are approved in accordance with local and state applicable standards. This approval does not relieve the applicant of the responsibility of compliance with the applicable codes. ❑ Approved with comments Approved as submitted zes Date: 0110 5, S c- rl UNIT TYPE DESIGNATION TYP SF---E PAGE PA �c,�4 FOR UNIT DETAILS SECOND F LOOR --1 I L -' A L 4 L P, TD f-4-c.P TYP FIRE CONTROL ROOM SEE PAGE FA. Lf FOR DETAIL ........... . ... ....... EHFIST FLOO To r- f BLDG A BLDG - �F' \BARRIER FREE UNITS B f S TI-17-1 RD F LOO R -- ro bps -To r-ACP F FIRST r --LOOK ZVS " C� r n 10 '70 BLDG T wffs' TYP, FIRE CONTROL ROOM r f-0 fpr BARRIER FREE UNITS BLDG J" nss . THIRD FLOOR ,SECOND FLOOR p -r° Fr, < -p s C 3 E I RST FLOOR -r n n r nn n Ka �8 11=x/ sT ° PATI0 ,� . I I N I TT n X1/8 „ _ I UNIT B 116 It= I' UNIT B e„ UNIT D Y „� � . 8 f UNIT C Y8 11= / f a <1 'P. bT-) (- , . � I�,C e 0 ( 4-L-, e A-M sc- 4'1 scl� (v sc-* 5 r-P 5(T-e- LOOP 4--r- 0 Eil El AA. AA 0,A4 I< A7-fOA-1 rh