20160152 Mechanical Plan Set 03012016GENERAL Hvac (CONL.) N N NORTH ARROW '- LINEAR SUPPLY AIR DIF =FUSER � � ® SQUARE SUPPLY AIR DIF =FUSER ~ /A__ SECTION CALLOUT z SQUARE RETURN AIR GRILLE ® SQUARE EXHAUST AIR GIRILLE SIDEWALL SUPPLY AIR GIRILLE OR DETAIL CALLOUT REGISTER --A,,_ OR REGISTER URN /EXHAUST AIR GRILLE POINT OF CONNECTION AIR FLOW DIRECTION THRRU DOOR Q REVISION NOTE 3 GRILLE OR UNDERCUT FLAG NOTE (CONSTRUCTION) EF -3 EQUIPMENT IDENTIFIER ABBREVIATIONS LIGHT LINE WEIGHT INDICATES EXISTING WORK AC AIR CONDITIONING ACF AIR CURTAIN FAN f + BOLD LINE WEIGHT INDICATES NEW WORK ADA AMERICAN DISABILITIES ACT AD AREA DRAIN ADJ ADJACENT, ADJUST, ADJUSTABLE, ADJUSTMENT r-- - - - -+ LIGHT DASHED LINES INDICATE WORK TO BE AFF ABOVE FINISHED FLOOR ABANDONED OR REMOVED AL ACOUSTIC LINED ALIGN ALIGNMENT SLASHED LINES INDICATE EXISTING WORK TO AP ACCESS PANEL BE DEMOLISHED APPROX APPROXIMATELY ARCH ARCHITECTURAL H\ / VAC ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS AVG AVERAGE C BFF BELOW FINISH FLOOR CUBIC FEET PER MINUTE BHP BRAKE HORSEPOWER BLDG BUILDING CENTER LINE BOD BOTTOM OF DUCT BOP BOTTOM OF PIPE 0 ROUND DUCT INDICATOR BPD BACKFLOW PREVENTION DEVICE BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNITS PER HOUR �- - - --a THERMOSTAT LINE BV BALANCING VALVE RISE CD CEILING DIFFUSER �-CC -+ RISE DIRECTION OF RISE FOR DUCT CFM CUBIC FEET PER MINUTE CG CEILING GRILLE 2402 DUCT (FIRST FIGURE DENOTES VIEW SHOWN) CI CAST IRON CLG CEILING 10x8 SINGLE LINE DUCTWORK INDICATES DUCT CO CLEANOUT 24x12 WITH VIEW DIMENSION LESS THAN 12 CONN CONNECT, CONNECTED, CONNECTION INCHES CONST CONSTRUCTION CONT CONTINUOUS, CONTINUATION COORD COORDINATE SUPPLY OR EXHAUST TAKEOFF CORR CORRIDOR COTG CLEANOUT TO GRADE CU FT CUBIC FEET �® SUPPLY DUCT TURNING TOWARD, UP CU IN CUBIC INCHES CW COLD WATER -] x SUPPLY DUCT TURNING AWAY DB DIY BULB TEMPERATURE DCV DEMAND CONTROL VENTILATION DCVA DOUBLE CHECK VALVE ASSEMBLY �--� EXHAUST DUCT TURNING TOWARD, UP DEG DEGREE DET DETAIL DFU DRAINAGE FIXTURE UNIT c� EXHAUST DUCT TURNING AWAY DIA DIAMETER DIFF DIFFERENTIAL, DIFFERENT, DIFFUSER �--o ROUND DUCT TURNING TOWARD, UP DIM DIMENSION DISCH DISCHARGE DN DOWN F� I v ROUND DUCT TURNING AWAY DOM DOMESTIC DR DRAIN DS DOWNSPOUT CONICAL WYE DSD DUCT SMOKE DETECTOR DWG DRAWING r x � CONICAL TEE EA EACH -� VOLUME DAMPER(VD) EAT ENTERING AIR TEMPERATURE EF EXHAUST FAN EFF EFFICIENCY 40- FIRE SMOKE DAMPER(FSD) EG EXHAUST GRILLE ELECT ELECTRICAL ❑- MOTORIZED DAMPER(FD) ELEV ELEVATION EMERG EMERGENCY 0 - FIRE DAMPER(FD) ENT ENTERING EXH EXHAUST EXIST EXISTING ® 3 -WAY SUPPLY DIFFUSER EXP EXPANSION m F FAHRENHEIT 2 -WAY SUPPLY DIFFUSER FC FANCOIL FCO FLOOR CLEANOUT 2 -WAY CORNER SUPPLY DIFFUSER FD FIRE DAMPER, FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION 1 -WAY SUPPLY DIFFUSER FIO FURNISHED AND INSTALLED BY OWNER FLA FULL LOAD AMP DOUBLE LINE, LINED DUCT ACOUSTIC DUCT FLEX FLEXIBLE / FLR FLOOR ANNE No mm"POP SINGLE LINE, LINED DUCT/ ACOUSTIC DUCT FOB FLAT ON BOTTOM FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR rrr TV FOT FLAT ON TOP RECTANGULAR 90' ELBOW W/ TURNING VANES TYPICAL FPM FEET PER MINUTE FPS FEET PER SECOND 30X20 FSD FIRE SMOKE DAMPER FT FOOT, FEET 18 "0 RECTANGLE TO ROUND FITTING FU FUTURE UNITS G GAS GA GAGE SOUND ATTENUATOR GAL GALLON GALV GALVANIZED GC GENERAL CONTRACTOR © ACCESS DOORS GENERAL GND GROUND GPH GALLONS PER HOUR GPM GALLONS PER MINUTE FLEXIBLE DUCT GW GREASE WASTE T QS THERMOSTAT OR TEMPERATURE SENSOR H HEIGHT, HIGH HB HOSE BIBB Q THERMOSTAT OR TEMPERATURE SENSOR(CEILING) HP HORSEPOWER HR HOUR 19> DUCT SMOKE DETECTOR HTG HEATING HVAC HEATING VENTILATING AND AIR CONDITIONING APT DIFFERENTIAL PRESSURE TRANSDUCER HW HOT WATER HWC HOT WATER CIRCULATING ROUND SUPPLY AIR DIFFUSER 00 ►---�� HWR HOT WATER HEATING RETURN HWS HOT WATER HEATING SUPPLY ROUND SUPPLY AIR DIFFUSER WITH HZ HERTZ PORTION BLANKED OFF ABBREVIATIONS (CONT.) IBC INTERNATIONAL BUILDING CODE ID INDIRECT DRAIN IE INVERT ELEVATION IMC INTERNATIONAL MECHANICAL CODE IN INCH INSUL INSULATE, INSULATION IW INDIRECT WASTE KW KILOWATT KWH KILOWATT HOUR L LENGTH LAV LAVATORY LAT LEAVING AIR TEMPERATURE LBS POUNDS LF LINEAL FOOT LVG LEAVING MA MIXED AIR MAX MAXIMUM MBH, MBTU THOUSAND BRITISH THERMAL UNITS PER HOUR MCA MINIMUM CIRCUIT AMPACITY MCC MOTOR CONTROL CENTER MD MOTORIZED DAMPER MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM, MINUTE MISC MISCELLANEOUS MOD MOTOR OPERATED DAMPER MTD MOUNTED MTG MOUNTING NA NOT APPLICABLE NC NOISE CRITERIA NIC NOT IN CONTRACT NTS NOT TO SCALE OAC OUTDOOR AIR CONDITIONER OAT OUTSIDE AIR TEMPERATURE OD OUTSIDE DIAMETER, OVERALL DIAMETER OH OVERHEAD ORD OVERFLOW ROOF DRAIN OSA OUTSIDE AIR P PUMP PD PRESSURE DROP, PIT DRAIN PH PHASE POC POINT OF CONNECTION PRELIM PRELIMINARY PRESS PRESSURE PRV PRESSURE REDUCING VALVE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAGE RA RETURN AIR RD ROOF DRAIN RECIRC RECIRCULATING RECT RECTANGULAR REF REFERENCE REG REGULATOR READ REQUIRED RND ROUND RPBP REDUCED PRESSURE BACKFLOW PREVENTER RPM REVOLUTIONS PER MINUTE RV RELIEF VALVE SAN SANITARY SCHED SCHEDULE SD SUPPLY DIFFUSER SF SUPPLY FAN, SQUARE FEET SG SUPPLY GRILLE SO SCREENED OPENING SOV SHUT OFF VALVE SP STATIC PRESSURE SPEC SPECIFICATION SPECD SPECIFIED SST STAINLESS STEEL SS SOIL STACK, SANITARY SEWER STRUCT STRUCTURAL SWG SUPPLY WALL GRILLE SWR SUPPLY WALL REGISTER TBD TO BE DETERMINED TEMP TEMPERATURE, TEMPORARY TSTAT THERMOSTAT THRU THROUGH TOD TOP OF DUCT TOP TOP OF PIPE TP TRAP PRIMER TS TEMPERATURE SENSOR TV TURNING VANE TW TEMPERED WATER TWR TEMPERED WATER RECIRCULATE TYP TYPICAL UPC UNIFORM PLUMBING CODE UTR UP THRU ROOF V VENT VAV VARIABLE AIR VOLUME VB VACUUM BREAKER VD VOLUME DAMPER VEL VELOCITY VERT VERTICAL VOL VOLUME VS VENT STACK VTR VENT TO ROOF W WASTE WCO WALL CLEAN OUT WB WET BULB TEMPERATURE WEF WALL EXHAUST FAN WG WATER GAGE WHA WATER HAMMER ARRESTOR W/ WITH W/0 WITHOUT WS WASTE STACK WT WEIGHT WSFU WATER SUPPLY FIXTURE UNIT DRAWING LIST MO.0 LEGEND & NOTES - MECHANICAL M1.0 SCHEDULES & ROOF PLAN - MECHANICAL M4.0 DETAILS - MECHANICAL GENERAL HVAC NOTE: 1. CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK (HVAC) ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. 2. LOCATE ALL TEMPERATURE, DEVICES IN DUCTWORK LOCATIONS WITH STRAIGHT SECTION OF DUCT UP AND DOWNSTREAM AS RECOMMENDED BY THE MANUFACTURER FOR GOOD ACCURACY. 3. COORDINATE AND PROVIDE ALL DUCT TRANSITIONS REQUIRED FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE ALL DUCT DIMENSIONS BEFORE FABRICATION. 4. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS REQUIRED TO PROVIDE A VIBRATION FREE INSTALLATION, AND SEISMICALLY BRACED AS REQUIRED. PROVIDE VIBRATION ISOLATION FOR ALL MECHANICAL EQUIPMENT TO PREVENT TRANSMISSION OF VIBRATION TO BUILDING STRUCTURE. 5. CERTAIN ITEMS SUCH AS RISES AND DROPS IN DUCTWORK, ACCESS DOORS, VOLUME DAMPERS, ETC. ARE INDICATED ON THE CONTRACT DOCUMENT DRAWINGS FOR CLARITY FOR A SPECIFIC LOCATION REQUIREMENT AND SHALL NOT BE INTERPRETED AS THE EXTENT OF THE REQUIREMENTS FOR THESE ITEMS. 6. UNLESS OTHERWISE SHOWN, LOCATE ALL ROOM THERMOSTATS 4' -0" (CENTERLINE) ABOVE FINISHED FLOOR. NOTIFY THE ENGINEER OF ANY ROOMS WHERE THE ABOVE LOCATION CANNOT BE MAINTAINED OR WHERE THERE IS A QUESTION ON LOCATION. 7. ALL DUCTWORK SHALL CLEAR DOORS AND WINDOWS. 8. PROVIDE ALL 90 DEGREE SQUARE ELBOWS WITH DOUBLE RADIUS TURNING VANES UNLESS OTHERWISE INDICATED. PROVIDE ACCESS DOORS UPSTREAM OF ALL ELBOWS WITH TURNING VANES. 9. UNLESS OTHERWISE NOTED, ALL DUCTWORK IS OVERHEAD, TIGHT TO THE UNDERSIDE OF THE STRUCTURE (WITHIN TRUSSES), WITH SPACE FOR INSULATION IF REQUIRED. 10. MAXIMUM LENGTH OF FLEXIBLE DUCTS LOCATED ABOVE HARD CEILINGS SHALL BE AS CODE PERMITS BUT NO LONGER THAN 4 FEET. 11. ALL DUCTWORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS, INCLUDING DIVIDED DUCTS AND TRANSITIONS AROUND OBSTRUCTIONS, SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. 12. PROVIDE ACCESS DOORS IN DUCTWORK TO PROVIDE ACCESS FOR ALL VOLUME DAMPERS AND OTHER ITEMS LOCATED 'IN THE DUCTWORK WHICH REQUIRE SERVICE AND /OR INSPECTION. 13. ALL DUCTS SHALL BE GROUNDED ACROSS FLEXIBLE CONNECTIONS WITH FLEXIBLE COPPER GROUNDING STRAPS. GROUNDING STRAPS SHALL BE BOLTED OR SOLDERED TO BOTH THE EQUIPMENT AND THE DUCT. 14. ALL OSA, RELIEF /EXHAUST AIR, AND RETURN AIR DAMPERS SHALL BE MOTORIZED CONTROL AND SHALL HAVE A MAX LEAKAGE OF 4CFM /FT' 0 1.0"WG IN ACCORDANCE W/ AMCA 500D. GENERAL NOTES: 1. COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE LATEST ADOPTED VERSION OF INTERNATIONAL BUILDING CODE (IBC), INTERNATIONAL MECHANICAL CODE (IMC), WASHINGTON STATE ENERGY CODE (WSEC), UNIFORM PLUMBING CODE (UPC), INTERNATIONAL FUEL GAS CODE (IFGC), INTERNATIONAL FIRE CODE (IFC), NFPA AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL JURISDICTIONS. 2. CONTRACTOR SHALL COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS AND DUCT ROUTING CLEARANCES WITH THE STRUCTURAL, REFLECTED CEILING AND LIGHTING PLANS. 3. MAKE ACCEPTABLE ACCESS PROVISIONS FOR REMOVAL OF FILTER AND MAINTENANCE FOR ALL INDOOR UNITS. REFER TO MANUFACTURER'S INSTALLATION GUIDE. 4. ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE. 5. WHEN MECHANICAL WORK (HVAC, PLUMBING, SHEET METAL, FIRE PROTECTION, ETC.) IS SUBCONTRACTED, IT SHALL BE THE MECHANICAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE SUBCONTRACTORS AND THE ASSOCIATED CONTRACTS. WHEN DISCREPANCIES ARISE PERTAINING TO WHICH CONTRACTOR PROVIDES A PARTICULAR ITEM OF THE MECHANICAL CONTRACT OR WHICH CONTRACTOR PROVIDES FINAL CONNECTIONS FOR A PARTICULAR ITEM OF THE MECHANICAL CONTRACT, IT SHALL BE BROUGHT TO THE ATTENTION OF THE MECHANICAL CONTRACTOR. 6. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE DOCUMENTS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS MUST BE DETERMINED BY THE PROJECT SITE CONDITIONS AND SHALL HAVE THE APPROVAL OF THE ENGINEER BEFORE BEING INSTALLED. DO NOT SCALE DRAWINGS. 7. ALL GAS EQUIPMENT SHALL BE INSTALLED PER THEIR LISTINGS, IMC, UPC, IFGC AND LOCAL CODES. 8. ALL ROOF PENETRATIONS SHALL BE MINIMUM OF 5 FEET AWAY FROM THE AREA /OCCUPATION SEPARATION WALLS. ALL PIPE, DUCT AND CONDUIT PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE. 9. ALL EQUIPMENT, DAMPERS, PIPING, AND ACCESSORIES IN CONCEALED SPACES REQUIRING ACCESS SHALL HAVE ACCESS DOORS. ALL ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED. COORDINATE LOCATIONS WITH ARCHITECT. CONTRACTOR TO PROVIDE ACCESS DOORS. 10. ALL EQUIPMENT SHALL BE FREE FROM DEFECTS IN MATERIAL, WORKMANSHIP, AND SHALL BE OF THE KIND AND QUALITY DESCRIBED HEREIN. 11. COORDINATE WITH THE STRUCTURAL ENGINEER AND GENERAL CONTRACTOR TO PROVIDE STRUCTURAL SUPPORT AND SEISMIC RESTRAINTS FOR ALL EQUIPMENT. 12. ALL EQUIPMENT SHALL BE APPROVED FOR INSTALLATION IN THE STATE OF WASHINGTON AND SHALL HAVE ALL CERTIFICATIONS AND RATINGS REQUIRED TO MEET ALL ENERGY, POLLUTION, ENVIRONMENTAL, SEISMIC, ETC. CODES AND REGULATIONS. 13. VERIFY ALL THE MECHANICAL EQUIPMENT'S ELECTRICAL LOADS VOLTAGE /PHASE, ETC. WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING. 14. WHERE MULTIPLE RISERS OR HORIZONTAL LOOPS ARE USED, BALANCING VALVES IN THE RETURN LINES ARE REQUIRED. A CHECK VALVE SHALL BE PROVIDED IN EACH RETURN TO PREVENT TEMPORARY REVERSAL OF FLOW. 15. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED AND AS REQURIED BY IMC, UPC, IBC, WASHINGTON STATE ENERGY CODE AND ALL APPLICABLE LOCAL AMMENDEMENTS. 16. INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS, CONTRACT DOCUMENTS, AND APPLICABLE CODES AND REGULATIONS. 17. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL, STRUCTURAL, ELECTRICAL WORK, ETC., SHOWN ON CONTRACT DOCUMENT DRAWINGS. 18. ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICAL EQUIPMENT OR PIPING INSULATION IS APPLIED. 19. TESTING, ADJUSTING, AND BALANCING AGENCY SHALL BE A MEMBER OF NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB). TESTING, ADJUSTING, AND BALANCING SHALL BE PERFORMED IN ACCORDANCE WITH THE NEBB STANDARDS. AABC ACCEPTABLE PENDING AGENCY APPROVAL. 20. WHERE TWO OR MORE ITEMS OF THE SAME TYPE OF EQUIPMENT ARE REQUIRED, THE PRODUCT OF ONE MANUFACTURER SHALL BE USED. 21. LOCATIONS AND SIZES OF ALL FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED WITH ALL OTHER TRADES INVOLVED. 22. REFER TO TYPICAL DETAILS FOR DUCTWORK, PIPING, AND EQUIPMENT INSTALLATION. 23. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE AS REQUIRED BY SECTION 1416.1 OF THE WSEC. THE DRAWINGS SHALL INDICATE THE LOCATION AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A MINIMUM, THAT HAVE BEEN DEVIATED FROM THESE DOCUMENTS. A COMPLETE RECORD OF CHANGES SHALL BE KEPT TO DATE ON A DAILY BASIS AND MADE ACCESSIBLE TO OWNER AND ENGINEER. GENERAL HVAC NOTE: (CONT. 16. ACCEPTABLE ACCESS PROVISIONS FOR REMOVAL OF FILTER AND MAINTENANCE FOR ALL INDOOR UNITS. 17. ALL AIR DISTRIBUTION SUPPLY OUTLETS AND RETURN /EXHAUST INLETS SHALL HAVE VOLUME CONTROL DEVICES. 18. ALL 90 DEGREE TRUNK DUCT ELBOWS SHALL BE SMOOTH -ROUND OR SQUARE WITH TURNING VANES. 19. CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF DUCTWORK WITHIN THE STRUCTURE AT SITE. 20. ALL FAN SYSTEMS WITH OVER 2000 CFM SHALL HAVE SMOKE /DUCT DETECTORS TO SHUT -DOWN FAN UPON DETECTION. DUCT /SMOKE DETECTORS FURNISHED AND INSTALLED BY ELECTRICAL AND WIRED BY ELECTRICAL. DUCT /SMOKE DETECTORS SHALL BE LISTED BY AN APPROVED AGENCY AND FOR INSTALLATION IN AIR DUCTS PER IMC. 21. ALL DUCT PENETRATIONS THROUGH RATED ENCLOSURES SHALL BE FIRE DAMPERED AND /OR SMOKE DAMPERED AS REQUIRED. 22. ALL MECHANICAL HEATING AND VENTILATION EQUIPMENT SHALL CONFORM TO SMACNA, LOCAL AND STATE REGULATIONS FOR SEISMIC RESTRAINT (INCLUDING PIPING AND DUCTWORK). COORDINATE WITH STRUCTURAL. 23. ALL RECTANGULAR DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. SUPPLY AND RETURN DUCTWORK FOR HVAC TO HAVE 1" SOUNDLINING FOR THE FIRST 10 FEET FROM UNIT DISCHARGE OUTLET. ALL DUCT LINING TO MEET AND EXCEED MOLD, HUMIDITY, EROSION RESISTANT, ETC. TO MEET 1 MC CHAPTER 6. ALL DUCTWORK TO BE CLASS -1 AIR DUCTS. CLASS -11 DUCTS SHALL NOT BE USED. 24. PROVIDE COMPLETE REFRIGERATION PIPING, INSULATION AND CONTROLS TO ALL MECHANICAL REFRIGERANT EQUIPMENT. 2012 WASHINGTON STATE ENERGY CODE WSEC) NOTES 1. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES INDICATED IN TABLE C403.2.3(1)A THRU C403.2.3(8) OF THE WSEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. 2. PROVIDE DEADBAND BETWEEN HEATING /COOLING SPACE SENSOR SETPOINTS OF 5 DEGREES AS REQUIRED BY SECTION C403.2.4.2 OF THE WSEC OR AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES, IF PROVIDED. 3. HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF ACCOMPLISHING SETBACK OR SHUTDOWN DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION C403.2.4.3.2 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES, IF PROVIDED. 4. PROVIDE BALANCING DEVICES IN ALL BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION C408.2.2.1 AND C408.2.2.2 OF THE WSEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. 5. ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDARDS FOR CONSTRUCTION OF GALVANIZED DUCTWORK. ALL DUCTWORK SHALL BE SEALED AS REQUIRED BY SECTION C403.2.7 "DUCT AND PLENUM INSULATION AND SEALING" OF THE WSEC. DUCT TAPE NOT ALLOWED. 6. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.7 "DUCT AND PLENUM INSULATION AND SEALING" OF THE WSEC. 7. ALL PIPING SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.8 OF THE WSEC. 8. INDIVIDUAL ZONE TERMINAL UNITS AND HVAC SYSTEMS SERVING PORTIONS OF THE BUILDING HAVING LESS THAN 24 -HOUR OPERATION SHALL BE SHUT OFF DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION C403.2.4.3 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES, IF PROVIDED. 9. SUPPLY AIR AND WATER TEMPERATURES SHALL BE AUTOMATICALLY RESET AS REQUIRED IN SECTION C403.4.3.4 AND C403.4.5.4 OF THE WSEC OR AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES, IF PROVIDED. 10. ALL AIR SYSTEMS SHALL BE PROVIDED WITH A 100% CAPABLE AIR ECONOMIZER CAPABILITY AS REQUIRED BY THE SECTION C403.3.1 AND C403.4.1 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES, IF PROVIDED. C403.4.1 EXCEPTION NO.6 EXERCISED ON NEW VRF SYSTEM. 11. AIR ECONOMIZERS SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET THE REMAINDER OF THE COOLING LOAD. 12. SIMULTANEOUS HEATING AND COOLING TO INDIVIDUAL ZONES SHALL BE PROHIBITED AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES EXCEPT WHERE PERMITTED IN SECTION C403, EXCEPTIONS 1 THROUGH 5 OF THE WSEC. 13. VARIABLE FREQUENCY DRIVES SHALL BE PROVIDED FOR VARIABLE FLOW HEATING AND AIR HANDLING SYSTEMS AS REQUIRED BY SECTION C403.2.12 OF THE WSEC AND AS DESCRIBED IN THE CONTRACT DOCUMENTS INCLUDING TEMPERATURE CONTROL SEQUENCES, IF PROVIDED. 14. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM CALLOUTS PER SECTION C403.2.13 OF THE WSEC FOR FULL LOAD EFFICIENCIES. 15. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION C408.2.2.1 AND C408.2.2.2 OF THE WSEC. 16. ELECTRIC WATER HEATERS LOCATED IN UNCONDITIONED SPACES OR ON CONCRETE FLOORS SHALL BE SEPARATED FROM THE SUPPORTING SURFACE WITH R -10 RIGID NSULATION AS DESCRIBED IN SECTION C404.5 OF THE WSEC. 17. DOMESTIC HOT WATER CIRCULATION PUMPS SHALL BE AUTOMATICALLY SHUT DOWN DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION C404.8 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES IF PROVIDED. 18. OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED TO THE OWNER AS REQUIRED BY SECTION C408.1.3.2 OF THE WSEC. AS A MINIMUM, THE MANUALS SHALL INCLUDE: A. SUBMITTAL DATA. B. OPERATION AND MAINTENANCE DATA FOR EQUIPMENT. C. NAMES AND ADDRESSES OF SERVICE AGENCIES. D. HVAC CONTOLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION. E. NARRATIVE OF HOW SYSTEM IS INTENDED TO OPERATE. 19. COMMISSIONING SHALL BE PROVIDED AND A REPORT OF COMMISSIONING BE SUBMITTED TO THE OWNER AS REQUIRED BY SECTION C408 OF THE WSEC. AND CONTRACTOR SHALL SUBMIT FORM "FIGURE C408.1.2.1" COMMISSIONING COMPLIANCE CHECKLIST. 20. IF NOT SPECIFICALLY STATED ABOVE, CONTRACTOR SHALL COMPLY WITH THE WSEC ITEMS THAT DO APPLY TO THIS PROJECT. LOCATION: STORE# 14529 1304 YELM AVE. YELM, WA. BY- ------ -------- - - - - -- PERMIT DRAWINGS REV DATE TITLE DRAWN: DMA Qc: DATE: 02/16/16 PROJ. NO: 2016 -01 LEGEND & NOTES - MECHANICAL M0.0 W LO .,= x O LL O u7 .72 s LO 00 m z�C < to 0O � 00 I Q ar- r- _ D 00 00 0 N -f , :::) j UNIT PANEL STEEL BASE 2x5 TUBULAR UNIT LIFTING 14 GAUGE ST OR BENT PLA NEOPRENEVI PLYWOOD SHEET METAI FLASHING. CANT STRIP ROOFING ROOF DECK STRUCTURAL SEE STRUCTI FOR EXACT T TO STRUCTU ROOF TOIp UNIT NEOPRENE GASKET SECURE UINIT TO CURB AND UNIT STEAL BASE WITH (10) #10 SELF TAPPING SCREWS ()R (10)1/4" BOLTS PRE SIDE 2x4 NAILING STRIP ROOF CURB (LEVEL TOiP OF CURB, VARY CURB HEIGHT TO COMPENSATE FOR ROOF SLOPE) PREFABRICATED ROOF CURB DETAIL SCALE: N.T.S. RIGID INSULATION 4" ACOUSITICAL DUCT LINER INSULATION COORDINATE WITH STRUCTURAL DRAVVINGS FOR CURB SUPPORT NOTES: 1. PROVIDE NECESSARY TRANSITION FROM THE UNIT DISCHARGE AND RETURN OPENINGS TO THE DUCT WORK SHOWN ON THE PLAN. 2. ROOF CURBS SHALL BE LEVEL AT TOP, VARY IN HEIGHT TO COMPENSATE FOR ROOF PITCH OR SLOPE. R.A. DUCT W/ 1" THICK LINER THRU. FIRST BEND — ROOF CURB - i i i RETURN LINED RETURN DROP ROOFTOP UNIT RTU MOUNTING DETAIL SCALE: N.T.S. S.A. DUCT W/ 1" THICK LINER THRU. FIRST BEND SUPPLY LINED SUPPLY DROP ROOF LOCATION: STORE# 14529 1304 YELM AVE. YELM, WA. PERMIT DRAWINGS REV DATE TITLE DRAWN: DMA QC: DATE: 02/16/16 PROJ. NO: 2016 -01 DETAILS- MECHANICAL M4.0 N 6 Z_ U � Lli Ln 4- X 0 Lo 12 t() 00 O co rO 04 Q V) O 00 o I t s :3 00 00 O CO N p N)N) z U D Un O LO cn (2- V) PERMIT DRAWINGS REV DATE TITLE DRAWN: DMA QC: DATE: 02/16/16 PROJ. NO: 2016 -01 DETAILS- MECHANICAL M4.0 6 Z_ 0) .c O s c O U Q V J od PERMIT DRAWINGS REV DATE TITLE DRAWN: DMA QC: DATE: 02/16/16 PROJ. NO: 2016 -01 DETAILS- MECHANICAL M4.0