20160114 Energy Calcs 04182016�Envelope Summary Zones 4c/5b ENV-SUM_; 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Oct 2013 Project Info Project Address 2016 -09 Yelm High III Date 4/18/2016 Compliance forms 1315 Yelm Ave. West For Building Department Use Yelm, WA 96597 do not require a password to use. Instructional and Applicant Name: Modern Building Systems, Inc. calculating cells are write - protected. Applicant Address: 9493 porter Rd., Aumsville, OR 97325 Applicant Phone: 503- 749 -4949 Project Description ❑ New Building ❑ Addition ❑ Alteration ❑ Change of Occupancy /Conditioning Compliance Path O Prescriptive p * Component Performance O Total Building Performance Selection required to enable forms. Occupancy Group OQ Commercial O Group R - R2 & R3 over 3 stories and all R1 Selection required to enable forms. Vertical Fenestration and Total Vertical Gross Exterior Skylight Area Calculation Fenestration Above Grade % Vertical If complying via the Prescriptive path, (rough opening) divided by Wall Area times 100 equals Fenestration 192.0 — 3592.0 X 100 — 5.3% enter values for vertical fenestration, skylights, gross walls and roof on this ENV -SUM worksheet. If complying via the Component Performance path, enter Gross Exterior these values in the ENV -UA worksheet. Total Skylight divided by Roof Area times 100 equals % Skylight These values auto -fill from ENV -UA and are write - protected on ENV -SUM. 0.0 8283.0 X 100 = 0.0% Fenestration Area Vertical VERTICAL FENESTRATION AREA COMPLIES Fenestration Area Compliance Skylight Area SKYLIGHT AREA COMPLIES Vertical Fenestration O 50% or more of the floor area is within a daylight zone per C402.3.1.1 Alternates O High Performance Fenestration U- factors and SHGC per C402.3.1.3 Compliance Method ❑ Skylight area 3% or greater, VT -0.40 or greater Single Story Spaces ❑ Skylight effective aperture 1 % or greater, provide calculation Requiring Skylights ❑ Space eligible for exception Requires a minimum of 50% of floor area to be within a skylight daylight zone for specific space types. Refer to C402.3.2 for requirements. ❑ Project has semi - heated spaces as defined per C402.1.4 ❑ Applying wall exception to semi - heated spaces 1. Semi - heated spaces may comply under Prescriptive or Component Performance compliance Semi - Heated Spaces path. 2. Semi - heated spaces shall be documented separately from other conditioned spaces — provide separate compliance forms for each conditioned space type. 3. Envelope elements separating semi - heated from other conditioned spaces shall comply with exterior thermal envelope requirements. ❑ Walk -in Cooler ❑ Walk -in Freezer ❑ Refrigerated Warehouse Cooler 1:1 Refrigerated Warehouse Freezer Refrigerated Spaces Refrigerated spaces shall comply under the Prescriptive Path only. Compliance documentation for these areas may be combined with non - refrigerated areas in the ENV - PRESCRIPTIVE form. Refer to C402.5 and C402.6 for requirements. Mixed Occupancy Project includes more than one occupancy type and /or level of space conditioning. Multiple and/or compliance forms may be required. Select all that apply to scope of project: Space Conditioning ❑ Commercial ❑ R2 & R3 over 3 stories and all R1 ❑ Refrigerated Space ❑ Fully Conditioned ❑ Semi - Heated ❑ Low Energy* ❑ R2 & R3 - 3 stories or less *Low energy areas are exempt from all thermal envelope provisions and compliance forms for these areas are not required. Refer to C101.5.2 for exemption. L G r, for Commercial RAldinas includina R2 & R3 over 3 stories and all R1 Revised Oct 2013 1uiz4vvasnmgiuli OWRi CHUIYY l uc vviiiF ui v v.... _. _. _. -_ _ Date 04/ 6 Project Address 2016 -09 Yelm High 111 For Building Department Use Occupancy Group * Commercial O Group R Change in occupancy or space conditioning O Note - Proposed UA may exceed Target UA by 10% per C101.4.4 and C101.4.5 Fenestration Area as % gross above -grade wall area 5.31-o Max. Target: 30.0% Skylight Area as % gross roof area 0.0 % Max. Target: 5.0% Vertical Fenestration Alternates: None Selected on ENV -SUM Notes: 1: If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target Area Adjustment of all applicable envelope elements will be calculated by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. 2: U- factors shall come from Appendix A, Chapter C303, or calculated per approved method as specified in C402.1.2. Building Component Proposed UA Target UA Provide source of U- factor, page /plan # of assembly detail & ID U- factor x Area (A) = UA (U x A U- factor x Area (A) = UA (U x A) R=38 ID: Sht. A3.1, Calculated U- Factor, See Attached 0.029 8283 240.2 0.034 8283 281.6 Above Deck Insulation U -0.034 Y R- ID: 0 R= ID: -6 R= ID: 0.031 Metal Building U -0.031 w o m R- ID: R= ID: R= ID: 0.021 Single raft, attic, other U -0.021 R- ID: 0 R= ID: R= ID: 0.055 Steel /metal frame U -0.055 u R= ID: R= ID: a� o R= ID: 0.052 Metal Building U -0.052 m ID: Q R= R= ID: � O R= 21 ID: Sht. A3.1, Calculated U- Factor, See Attached 0.050 3316 165. B o .054 3316 179.1 Wood Frame, other U -0.054 a) o R= ID: CU o 3: R= ID: R= ID: U -0.104 U) R- ID: 2i R= ID: rAssumed t° R= ID: o be Mass Wall U -0. 104 o � R= ID: Z a) m R= ID: CD R= ID: R= ID: 0.031 Mass Floor U -0.031 m R= ID: o R= ID: -o R=30 ID: Sht. A3.1, T.A105.1(1) Default (Joists, 0.029 9283 240.2 0.029 e2s3 240.2 Joist/Framing U -0.029 u E R= ID: 0 Perimeter) LL R= ID: F- factor x Perimeter = UA(U x A) F- factor x Perimeter = UA (U x A) R= ID: 0.540 Slab -On -Grade U -0.54 is ID: r R= DS R= ID: o a R= ID: 0.550 Heated Slab -On -Grade U -0.55 �n a R- ID: = R= ID: `Proposed non - residential CMU walls meeting Table C402.1.2 Area UA Area UA Footnote D requirements can use the target U -value of 0.104 rather Page 19 8 8 2 646 1 �88 701 than Appendix A values. Show footnote requirements in plans. Subtotal Component Performance Compliance (UA) UA COMPLIES • • • • • • • • n, In, ... ti,..,.�..., et .,+e V:or rnr e Comnlinnra Fnrmc fnr Cnmmercial Buildinas Includlncl R2 & R3 over: Revised Oct 2013 Project Address 2016 -09 Yelm High 111 Date 04/18/2016 Fenestration Area as % gross above -grade wall area 5.3% Max. Target: 3 0.0 % For Building Department Use Skylight Area as % gross roof area Max. Target: 5.0% Notes: 1: If vertical fenestration or skylight area exceeds maximum allowed per C402.3.1, then Target Area Adjustment of all applicable envelope elements will be calculated by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. 2: Provide NFRC rated U- factor or default U- factor from Appendix A for the fenestration assembly thermal performance (combination of frame and glazing). 3: Fenestration that separates conditioned space from a non - conditioned or semi - conditioned Building Component Proposed UA Target UA Provide source of U- factor, page /plan # of assembly detail & ID U- factor x Area (A) = UA (U x A U- factor x Area (A) = UA (U x A) U= 0 .3e ID: Door 1, Sht. A3.1, NFRC Certified 0.380 4z 16.0 0.37 94 31.1 Opaque Swing Doors U -0.37 � 0 U= 0.38 ID: Door 2, Sht. A3.1, NFRC Certified 0.380 42 16.0 m U= ID: 3 U= ID: U) U= ID: a N U= ID: 0.37 Opaque rollup & sliding U -0.37 o U- ID: U= ID: @ U= 0.34 ID: Window & B, Sht. A3.1, NFRC Certified 0.34 192 65.3 0.30 192 57.6 Non -Metal Frame U -0.30 W U= ID: 0 U= ID: Z U= ID: � U= ID: 0.38 Metal Frame, Fixed U -0.38 4 -- U= ID: m U= ID: m a) U= ID: L U= ID: 0.40 Metal Frame, Operable U -0.40 Cc °- U= ID: Z U= ID: U= ID: U= ID: 0.60 Metal Entrance Door U -0.60 U= ID: U= ID: U= ID: U= ID: 0.50 All types U -0.50 o n U= ID: U= ID: u) Q U= ID: Area UA Area vri Page 2 Subtotal 276 97 276 89 To comply: Page 1 Subtotal 19882 646 19882 701 1) Proposed Total UA shall not exceed Target Total UA. 2) Proposed Total Area shall equal Target Total Area. Total 20158 743 2 015 8 790 Component Performance Compliance (UA) UA COMPLIES 4 If vertic�nl fenestration area exceeds maximum allowed per Section C402.3.1, then Target Area Adjustment of all applicable envelope elements is �,equired. This worksheet automatically calculates these adjustments and updates target areas in the ENV -UA and ENV -SHGC worksheets. Information shown in this worksheet is for reference only and is write - protected. Submit this Target Area Adjustment form with ENV -UA and ENV -SHGC forms. VF = Vertical fenestration NW = Net above qrade wall (excludes fenestration and doors.) I DR = Opaque doors Gross Exterior Above -Grade Wall Area= VF + NW + DR A(; = Ahnve -grade Proposed Areas Total Vertical Excess Vertical Target Vertical Fenestration Fenestration Fenestration 192.0 - = 192.0 Net AG Wall Area Excess Fenestration Target Net Wall Area 3316.0 + = =3316 .0 UA Adjustments Vertical Fenestration Non -metal frame Metal frame, fixed Metal frame, operable Metal frame, entrance door Above -grade Wall Steel Frame Metal Building Wood / Other frame Mass Sum of Proposed SHGC x A Adjustments Non -North Vertical Fenestration PF < 0.2 0.2 s PF < 0.5 PF ? 0.5 North Vertical Fenestration PF < 0.2 0.2!5 PF < 0.5 PF > 0.5 -885.6 Multiplier applied to all Total Vertical Vertical Fenestration -> VF= 192.0 Target VF Multiplier MM - 192.0 Opaque > NW= 3316.0 DR= 84. 0 Gross Exterior Max Vert. Fen. % Proposed Opaque Above- Grade Wall Areas to Maximum Target AG Wall Area (C402.3.1) Vert. Fen. Area 3592.0 30.0% 100 = 1077.6 X - I otal Vertical Delta Vertical 0 Excess Vertical Fenestration Maximum Target Fenestration Fenestration 192.0 - 1077.6 = -885.6 greater = Total Vertical Excess Vertical Target Vertical Fenestration Fenestration Fenestration 192.0 - = 192.0 Net AG Wall Area Excess Fenestration Target Net Wall Area 3316.0 + = =3316 .0 UA Adjustments Vertical Fenestration Non -metal frame Metal frame, fixed Metal frame, operable Metal frame, entrance door Above -grade Wall Steel Frame Metal Building Wood / Other frame Mass Sum of Proposed SHGC x A Adjustments Non -North Vertical Fenestration PF < 0.2 0.2 s PF < 0.5 PF ? 0.5 North Vertical Fenestration PF < 0.2 0.2!5 PF < 0.5 PF > 0.5 -885.6 Multiplier applied to all Total Vertical Proposed Vertical Fenestration Target VF Multiplier Fenestration Areas to calculate Target Vertical - 192.0 = 1. 0 0 Fenestration Area Net Wall Target Net Wall Mult. Multiplier applied to all 3316.0 = 1. 0 0 Proposed Opaque Above- Grade Wall Areas to calculate Target Above- Proposed Area Target VF Mult. Target Area 192.0 X 1.00 = 192.0 X _ X _ X I Target areas in shaded Proposed Area Target Net Wall Mult. Target Area boxes are applied to _ target areas on ENV -UA X 3316.0 X 1.00 = 3316.0 X Sum of target above -grade 3 5 0 8. 0 Sum of Target 3508.0 wall and vertical fenestration areas are calculated to equal the sum of proposed Proposed Area Target VF Mult. Target Area 192.0 X 1.00 = 192.0 X X SHGC target areas in shaded boxes are applied to target areas on ENV - SHGC 'kvliaht Taraet Area Adiustment Calculations If skylight area exceeds maximum allowed per Section C402.3.1, then Target Area Adjustment of all applicable envelope elements is required. This worksheet automatically calculates these adjustments and updates target areas in the ENV -UA and ENV -SHGC worksheets. Information shown in this [SKY= Ckvliaht I NR - Net roof (excludes skylight) I Gross Exterior Roof Area = SKY + NR Proposed Areas Skylight (Horizontal Fenestration) -I SKY= Opaque Roof -> NR= 8283. 0 Gross Exterior Max Skylight % Maximum Skylight Roof Area (0402.3. 1) Fenestration Area 8283.0 X 5.0% — 100 = 414.2 Total Skylight Area Maximum Target Delta Skylight Area 0 Excess Skylight -414.2 :j greater = -414.2 Total Skylight E Skylight Target Skylight A Total Skylight Area Target SL Multiplier Multiplier applied to all )I9 ht Area Excess Area Proposed Skylight Areas to calculate Target SkylightArea Net Roof Area Excess Skylight Target Net Roof Area Net Roof Target Net Roof Mult. 8283.0 = 8283.0 — 8283.0 = 1.00 Multiplier applied to all Proposed Opaque Roof Areas to calculate Target UA and SHGC x A Adjustments Skylight All Roof Insulation Above Deck Metal Building Attic/ All Others Proposed Area Target SL Mult. Target Area X Proposed Area Target Net Wall Mult. Target Area 8283.0 X 1.00 = 8283.0 X X Sum of target roof and skylightareas are 8283.0 calculated to equal the sum of proposed Sum of Proposed 8283 . 0 Sum of Target on10 W—hi., tr,n Fnornv f'nric C m—li —ro Fnrmc fnr r:nmmarrial Ri ilriinns inchiriinn Ri & R3 over 3 stories and all R1 Revised Oct 2013 Project Address 2016 -09 Yelm High III Date 04/18/2016 0 5. 3 % Max. Target: 30% Fenestration Area as /o gross above -grade wall area 9 For Building Department Use Skylight Area as % gross roof area Max. Target: 5% Vertical Fenestration Alternates: None Selected on ENV -SUM Notes: 1 - Proposed vertical fenestration and skylight areas entered in ENV -SHGC must match proposed fenestration areas in ENV -UA. 192 76.8 2 - If Target Area Adjustment is required per ENV -UA, then target areas will be automatically 0 adjusted in ENV -SHGC. Refer to Target Area Adjustments worksheet for this calculation. 0.2 :5PF <0.5 0.48 3 - Provide NFRC rated SHGC or default from Table C303.1.3(3) for fenestration assembly SHGC. PF ? 0.5 0.64 4 - Fenestration that separates conditioned space from a non - conditioned or semi - conditioned ID: space shall be included in this worksheet. Skylights Proposed SHGC Target SHGC Provide source of SHGC, page /plan # of assembly detail & ID SHGC x Area (A) = SHGC x I SHGC x Area (A) = SHGC x A ID: 0.35 SHGC 0.35 ID: ID: 0 ID: SHGC will sum fenestration area by PF category. ID: 0 i Totals ID: Totals All Non -North Vertical Fenestration+ Proposed SHGC Target SHGC ++ Provide source of SHGC, page /plan # of assembly PF SHGC* x Area (A) = SHGC x A detail & ID PF SHGC x Area (A) = SHGC x A Category ID: Window A, Sht. A3.0, NFRC Certified 0 0.30 192 58 PF < 0.2 0.40 192 76.8 ID: 0 0.2 :5PF <0.5 0.48 PF ? 0.5 0.64 ID: 0 ++ If projection factor (PF) credits are ID: 0 ID: 0 applied to the proposed design, Target ID: 0 SHGC will sum fenestration area by PF category. ID: 0 i ID: 0 ID: 0 ID: 0 + If projection factor credit is applied, then vertical Totals 192.0 57.6 Totals 192.0 76.8 fenestration must be entered in the correct table according to orientation. It credit is not applied Men all vertical fenestration can be entered in either table. * Note: Fenestration that separates conditioned space from a non - conditioned or semi - conditioned space shall be listed here with a proposed SHGC equal to the target value. North Vertical Fenestration+ Proposed SHGC Target SHGC ++ Provide source of SHGC, page /plan # of assembly PF SHGC* x Area (A) = SHGC x A PF SHGC x Area (A) = SHGC x A detail & ID Category ID: 0 PF <0.2 0.40 ID: 0 0.2 <_PF <0.5 0.44 ID: 0 PF ? 0.5 0.48 ID: 0 ++ If projection factor (PF) credits are applied ID: 0 1 to the proposed design, Target SHGC will ID: 0 sum fenestration area by PF category. ID: 0 North Total Area I SHGC x Al Area I SHGC x A To comply, the Proposed total SHGC x A for all fenestration (vertical Grand I Grand & skylights) shall not exceed the Target total SHGC x A. Total 192.0 57 .6 Total 192.0 76.8 Component Performance Compliance (SHGC) SHGC COMPLIES Y ,$uilding Permit Plans Checklist, •• 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Address 2016 -0e Yelm High iii Date 4/18/2016 The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy Code, Commercial Provisions. Applicability Code Location in Building (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes SCOPE na C101.5.2 Low energy spaces Low energy spaces identified on plans na C101.5.2.1 Semi - heated spaces Semi - heated spaces identified on plans C402.1.4 C402.5 Cooler and freezer Walk -in and refrigerated warehouse cooler and freezer spaces identified on na C402.6 spaces plans na C101.4.6 Mixed occupancy Spaces with different occupancy requirements identified on plans Change of Existing F, S and U- occupancy building spaces undergoing a change of na C101.4.4 occupancy /space occupancy or space conditioning that require compliance are identified on C101.4.5 conditioning plans ENVELOPE PROVISIONS yes C303.1 Insulation Indicate identification mark shall be applied to all insulation materials Ao o identification . C303.1.3 Fenestration product Fenestration products shall be labeled with rated U- factor, SHGC, VT, and yes C402.4.3 rating leakage rating A0.0 Indicate installation methods, thicknesses, densities and clearances to achieve C303.1.1 General insulation the intended R -value of all insulation materials; yes C402.2 installation Where two or more layers of rigid insulation will be used, indicate that edge joints between layers are staggered A3.0 S3.0 Indicate R- value(s) of cavity /continuous insulation on roof sections, Indicate framing materials on roof sections; Indicate method of framing for ceilings below vented attics and vaulted ceilings yes C402.2.1 Roof assembly per At 02.2 (std, adv); insulation Provide area - weighted calculations for sloped insulation installed entirely above deck; Indicate R- values for thermal spacers and each insulation layer, and liner system (LS) method for metal building roofs A3.0 a S3.0 Skylight curb Indicate curb insulation R -value on roof section if not included in skylight NFRC na C402.2.1 insulation rating Indicate R- value(s) of cavity /continuous insulation on wall sections, Indicate framing materials on wall sections; Indicate method of framing for wood const per At 03.2 (std, int, adv); C402.2.3 Above /below grade yes C402.2.4 Indicate mass of masonry walls; C303.2.1 wall insulation Indicate loose -fill core insulation material, percentage of cores filled, and frequency of grouted cores and bond beams for masonry walls; Indicate method of protection of exposed exterior basement/crawlspace wall insulation Indicate insulation R- values of ceilings, walls, doors, floors on sections; Walk -in /refrigerated na C402.5 warehouse cooler Indicate method of minimizing door infiltration; C402.6 and freezer insulation Indicate type(s) of transparent doors and windows - Indicate rated U- factor (swinging) or R -value (roll -up /sliding) on wall sections - yes C402.2.7 Opaque doors applies to doors with less than 50% glazed area A3.0 Indicate R- value(s) of cavity /continuous insulation on floor sections; Floor over outdoor or yes C402.2.5 unconditioned space Indicate framing material on floor sections, insulation Indicate mass of masonry floors A3.0 a S3.0 Indicate R -value of continuous insulation on wall section or foundation detail; C402.2.6 Slab -on -grade floor Indicate insulation extends down vertically and /or horizontally the required na C303.2.1 insulation distance from top of slab; Indicate method of protection of exposed exterior slab edge insulation Indicate R -value of continuous insulation on wall section or foundation detail; C402.2.6 Radiantly heated slab Indicate insulation extends down vertically from top of slab and then horizontally na on -grade floor C303.2.1 insulation under the entire slab, Indicate method of protection of exposed exterior slab edge insulation Radiant heating Indicate insulation R -value behind radiant panels, U- bend /headers and bottom na C402.2.8 system insulation surface of radiantly heated floors (other than radiantly heated slab -on- grade) RZOlding Permit Plans Checklist, •• 2 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 F201 ject Address 2016 -09 Yelm High ul Date 4/18/2016 licability Code Location in Building s,no,na) Section Component Compliance information required in permit documents Documents Department Notes Vertical fenestration Provide calculation for total vertical fenestration area as percentage of gross yes C402.3.1 maximum area above grade wall area ENV SUM na C402.3.1.2 Skylight maximum Provide calculation for total skylight area as percentage of gross roof area area Indicate U- factors, SHGC and VT values in fenestration schedules; C402.3.3 U- factors, SHGC and An area - weighted U -value may be used for all fenestration elements that qualify yes C402.3.1.3 VT for all fenestration within the same fenestration category per Table C402.3; C303.1.3 assemblies Indicate if values are NFRC or default. If default then specify frame type, glazing layers, gap width, low-e coatings, gas -fill. A3.0 Provide calculations showing that percentage of overall conditioned floor area C402.3.1.1 Increased max. in the daylight zone is equal to or greater than 50 %; na Chap.2 vertical fenestration area with daylighting Indicate method of daylighting control in lighting equipment schedules; Definition controls Indicate VT of vertical fenestration is at least 1.1 times the rated SHGC Increased max. Indicate high performance U- factors and SHGC values in fenestration vertical fenestration schedules; na C402.3.1.2 area with high- An area - weighted U -value may be used for all fenestration elements that qualify performance glazing within the same fenestration category per this section - C402.3.3 Permanent shading Provide projection factor calculations (Equation C4 -2) and associated SHGC na C402.3.3.1 devices multipliers for north and non -north orientations _ Provide calculations for percentage of conditioned floor area located within a skylight daylight zone, Provide calculations for percentage of skylight area to daylight zone under na C402.3.2 Single story spaces skylights, hts, OR; Yl 9 requiring skylights Provide calculations for percentage of overall skylight effective aperture (Equation C4 -1); Indicate haze factor of skylight glazing material or diffuser _ AIR LEAKAGE Indicate location of continuous air barrier on plans and sections; C402.4.2 Air barrier yes construction and Provide details for all joints, transitions in materials, penetrations in air barrier C402.4.2 sealing and note method of sealing (caulked, gasketed, or other approved method) A3.0 Indicate locations of all stairway and shaft vents; Provide leakage rating of motorized dampers in mechanical equipment na C402.4.5.1 Stairway and shaft schedules; vents Indicate method of emergency operation - activation of fire alarm or interruption of power Indicate locations of all outside air intakes, exhausts and relief outlets, includina Outdoor air intakes, those integral to mechanical equipment; yes C402.4.5.2 exhausts and relief Provide in mechanical equipment schedules leakage rating of dampers, identify openings whether motorized or gravity, and note any exceptions taken M1.0 Recessed lighting in Indicate IC rating of fixtures in lighting equipment schedules; na C402.4.8 building envelope Indicate method of sealing between light fixture housing and wall or ceiling na C402.4.6 Loading dock seals Indicate weather seal at cargo and loading dock doors - Indicate locations and dimensions of vestibules; na C402.4.7 Vestibules For unconditioned vestibules, indicate which envelope assembly (interior or exterior) complies with the requirements for a conditioned space Indicate air barrier test method in accordance with ASTM E779 or approved equivalent; C402.4 - Air barrier building include the following requirements in project documents: (1) air barrier test yes report shall be submitted to jurisdiction once test is completed; (2) if test results 1.2.3 test exceed 0.4 cfm /ft2 at 0.3 in. wg then visually inspect air barrier and seal noted sources of leakage; (3) submit a follow -up report to jurisdiction noting corrective measures taken 1A0.0 If "no" is selected for any question, provide explanation: End of Building Permit Plans Checklist Roof U -Value At Fra ing Members with Insulation Below(7.5 %) Layers A B C D E F `o `o Zb w c Layer Description Detail R -Value Exterior Surface Moving Air 15 MPH = 0.023 0.170 A Roofing Fiberglass Comp. Shingles 0.440 B Felt (2) Layers 15# Felt 0.060 C Sheathing 7/16" O.S.B. 1.155 D Rafters /Blocks 2x10 DF at 24" O.C. 9.805 E Insul. Below Framing R9 Cellulose (2.5 ") 9.000 F Interior Surface Still Air 0.610 Total R- Values 21.240 [-U-Value (1 /R- Value) 0.047 At Framing Members with Insulation Blocks Below (2.5 %) Layers A B C I D I E F `o_ `o_ w E Layer Description Detail R -Value Exterior Surface Moving Air 15 MPH 0.170 A Roofing Fiberglass Comp. Shingles 0.440 B Felt (2) Layers 15# Felt 0.060 C Sheathing 7/16" O.S.B. 1.155 D Rafters /Blocks 2x10 DF at 24" O.C. 9.805 E Insul. Blocks (5) at 2 x4 x 9" Long 3.710 F Interior Surface Still Air 0.610 Total R- Values 15.950 U -Value (1 /R- Value) 0.063 At Insulation (90 %) Layers A B C D E F o `o X c Layer Description Detail R -Value Exterior Surface Moving Air 15 MPH 0.170 A Roofing Fiberglass Comp. Shingles 0.440 B Felt (2) Layers 15# Felt 0.060 C Sheathing 7/16" O.S.B. 1.155 D Insulation R -38 Cellulose (10.6 ") 38.000 E F Interior Surface Still Air 0.610 Total R- Values 40.435 U -Value (1 /R- Value) 0.025 U -Value at Framing /Insul U -Value at Framing with Blk U -Value at Insulation 0.047 x 0.075 = 0.004 0.063 x 0.025 = 0.002 0.025 x 0.900 = 0.023 Total Roof U -Value 0.029 2012 Washinaton State Enerqv Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Info Project Address 2016 -09 KCDA Yelm High III Date 4/14/2016 Compliance 1315 Yelm Ave. West For Building Department Use forms do not require a Yelm, WA 98597 Applicant Name: Modern Building Systems, Inc. password to use. Applicant Address: 9493 Porter Rd, Aumsville, OR 97325 Instructional and calculating cells Applicant Phone: 503 - 749 -4949 are write- Project Description 0 New Building ❑ Addition ❑ Alteration ❑ Plans Included Lighting Compliance Path Lighting Power Density Calculations ❑ Total Building Performance is (If Total Building Performance then only LGT -CHK required.) Lighting Power Allowance 0 Building Area Method O Space -By -Space Method Method Selection required to enable LPs, forms Interior Lighting System Lay -in and surface mount ceiling fluorescent fixtures with electronic ballasts controlled by Description occupancy sensors, daylight sensors and /or wall switches. Briefly describe lighting system type and features. Additions and Change of Space Use (C101.4.3 & C101.4.4) ❑ Addition area or Change of Space Use area complies with all applicable provisions as stand alone project ❑ Addition area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions per C101.4.3 Provide Building Area Method (LTG - INT -BLD) or Space -By -Space Method (LTG -INT- SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) ❑ 60% or more of luminaires in space replaced Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT- SPACE) Compliance Form. Document maximum allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Retrofit and non - retrofit spaces shall be documented separately using multiple forms. ❑ Less than 60% of luminaires in space replaced Provide a separate Space -By -Space Method (L TG-INT-SPA CE) Compliance Form for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage table. ❑ Lamp and /or ballast replacement within existing luminaires only — existing total interior building wattage not increased ❑ New wiring installed to serve added fixtures and /or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 ❑ New or moved lighting panel Provide all applicable lighting controls as noted for New Wring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. ❑ Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wring and commissioning of lighting controls per C405.13. ❑ No changes are being made to the interior lighting and space use not changed. 2012 Washington State Enerov Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address 2016 -09 KCDAYelm High III Date 4/14/2016 Lighting Alterations, Renovations & Building Additions For Building Department Use O Less than 60% O 60% or more O Stand alone O Addition Watts Proposed Notes: Page E2.0 a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be 79 combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. 6952 b. For retrofits and building additions, provide Building Area types and gross interior areas in the Page E2.0 Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall 3 existing builidng, include all applicable existing Building Area types and gross interior areas. 174 c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 60% of existing fixtures will be replaced, use LTG -INT -SPACE form. Maximum Allowed Lighting Wattage Building Area* Location (plan #, room #, or ALL) Area Description Allowed Watts per ft2 Gross Interior Area in ft2 Wafts Allowed (watts /ft2 x area) School /university Page E2.0 Classrooms, Restroom, Mech, 0.99 8283 8200 * Select Table C405.5.2(1) Building Area from drop down menu. Totall 8283 Proposed Lighting Wattage Building Area* Location (plan #, room #) Fixture Description ** Number of Fixtures Watts/ Fixture Watts Proposed School /university Page E2.0 3 -Tube T8 32W Flouresent Lay -in with Elect. Ballast 79 88 6952 School /university Page E2.0 2 -Tube T8 32W Flouresent Lay -in with Elect. Ballast 3 58 174 Select Table C405.5.2(1) Building Area from drop down menu. ** Include existing to remain lighting and exempt lighting equipment per notes below. Compliance by Building Area Building Area Warnings Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance School /university 8200 7126 COMPLIES Total 8200 7126 Notes: 1. Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between Building Area types is not allowed under the Building Area Method compliance path. 2. Proposed fixtures must be listed in the building area in which they occur. Include ALL proposed lighting fixtures. 3. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 4. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 5. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 6. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description. • • • Summary 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Info Project Address: 2016 -09 KCDA Yelm High III Date 4/14/2016 1315 Yelm Ave. West For Building Department Use Yelm, WA 98597 Applicant Name: Modern Building Systems, Inc. Applicant Addr: 9493 Porter Rd, Aumsville, OR 97325 Applicant Phone: 503- 749 -4949 Project Description ❑ New Building ❑ Addition ❑ Alteration ❑ Plans Included Lighting Zone As specified by jurisdiction. Zone selection ❑ Zone 1 0 Zone 2 Zone 3 0 Zone 4 required to enable LTG -EXT form Compliance Option * Lighting Power Density Calculations 0 Total Building Performance Building Grounds Applies to luminaires > 100 Watts ❑ Efficacy> 60 Iumens/W ❑ Controlled by motion sensor ❑ Exemption (list) Exterior Lighting Alterations No changes are being made to the existing exterior lighting ❑ New wiring installed to serve added fixtures and /or fixtures relocated to new circuit Provide applicable exterior lighting controls per C405.2.4 and commissioning per Tradable Maximum Allowed Lighting Wattage Base Site Allowance: 750 Allowed a s Area (ft), perimeter Allowed Watts Tradable Surfaces Surface Description per fe or per If (If) or # of items x ff (or x If) Main Entry Door Door #1 30W /LF door 6 180 width Other Entry Door Door #2 20W /LF door 6 120 width Total Allowed Tradable Watts: 300 Tradable Proposed Lighting Wattage (Use mfgr listed maximum input wattage for luminaire.) Tradable Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Main Entry Door 42W Compact Fluorescent Wall Pack 1 42 42 Other Entry Door 42W Compact Fluorescent Wall Pack 1 42 42 Total proposed tradable watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts: . — -11 sti_ ti--- -;r - -, u,...,.,..,.,, A., , I. - ;fo nnf no Hl q fn mn4a 84 tradable watts comply can be applied to individual non- tradable categories. Non - Tradable Maximum Allowed Lighting Wattage Base Site Allowance Remaining: 750 Non - Tradable Surfaces Surface Description Allowed Watts per ftz or per If Area (ft), perimeter (If) or # of items Allowed Watts x fe (or x If) Non - Tradable Proposed Lighting Wattage Non - Tradable Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Non - tradable proposed watts may not exceed allowed watts for any individual Total excess Non - Tradable watts: 0 surface unless the total excess watts for all non - tradable surfaces are less than the Site Allowance Balance: 750 remaining site allowance. Exterior Lighting COMPLIES WITH SITE ALLOWANC MIA 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address 2016 -09 KCDA Yelm High III Date 4/14/2016 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Applicability Location in Building Department (yes, no,na) Code Section Component Compliance information required in permit documents Documents Notes LIGHTING CONTROLS (Section C405.2) Indicate on plans the manual control type & locations served; E0.1, & E2.0 Yes C405.2.1.1 Manual interior Indicate of plans the 50% lighting load reduction method Exception 2 C405.2.1.2 lighting controls provided or identify exception taken Indicate lighting system automatic shut -off capability - identify E2.0 lighting zone areas served on plans; Automatic time -- Indicate locations of override switches on plans and the areas NIA Yes C405.2.2.1 switch controls and served, include area sq. ft.; override switching Indicate locations where automatic shutoff is provided by other methods (occupancy sensor, daylight controls, etc) E2.0 Yes C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors E2.0 Daylight zones - Indicate vertical fenestration primary and secondary daylight E2.0 Yes C405.2.2.3 Vertical fenestration zone areas on plans, include sq. ft.; Indicate skylight daylight zone areas on plans, include sq. ft. and skylights N/A Indicate on plans the locations served by daylight zone controls; E0.1 & E2.0 Yes C405.2.2.3.2 Daylight zone controls Indicate in plans the lighting load reduction (dimming) method - stepped or continuous dimming E0.1 Specific application Indicate on plans the locations served by specific application NA C405.2.3 lighting controls - lighting controls General Indicate lighting control method for display and accent lighting, and display case lighting; NA C405.2.3 - Display and accent - - Indicate these fixtures are controlled independently from both — Items 1 &2 lighting general area lighting and other lighting applications within the same space Provide a lighting control device at each guest room entry for all NA C405.2.3 - Hotel /motel guest permanently installed fixtures in guest room; — - Item 3 rooms -- - -- - Indicated whether lighting control is manual or automatic C405.2.3 - Supplemental task Provide automatic shut -off vacancy controls for supplemental NA Item 4 lighting task lighting, including under -shelf or under - cabinet lighting Identify eligible non - visual applications and method of lighting control; NA C4052.3 - Lighting for non - Indicate these fixtures are controlled independentl y from both Item 5 visual applications general area lighting and other lighting applications within the same space Indicate lighting control method for lighting equipment for sale Lighting equipment or demonstration; NA C405.2.3 - for sale or Indicate these fixtures are controlled independently from both Item 6 demonstration general area lighting and other lighting applications within the - same space If egress lighting power density is greater than 0.05W /ftz, indicate method of automatic shut -off during unoccupied NA C405.2.3 - Means of egress periods; Item 7 lighting -- Identify on plans the egress fixtures that function as both normal and emergency means of egress illumination Provide vacancy device or timer to turn off fixtures within 15 NA C405.10 Cooler and freezer minutes of unoccupancy for cooler and freezer lighting fixtures C405.11 lighting with lamp efficacy less than 40 1 umens per watt Exterior lighting Indicate on exterior lighting plans the automatic lighting control E2.0 Yes C405.2.4 controls method and locations served Exterior building Provide motion sensor controls for building grounds fixtures NA C405.6.1 grounds lighting rated at greater than 100 watts with lamp efficacy less than 60 controls lumens, or identify exception taken Identify applicable commissioning documentation requirements A0.0 per Section C408 or el igibility for exception; Provide written procedures for functional testing of all automatic Lighting system A0.0 Yes C408.3 functional testing controls and describe the expected system response, Identify in construction documents the party responsible for AO .0 functional testing of automatic lighting controls INTERIOR LIGHTING POWER & EFFICACY Sections C405.5, C405.10, C405.11 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address 2016 -09 KCDA Yelm High III Date 4/14/2016 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Applicability Location in Building Department (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes Provide fixture schedule with fixture types, lamps, ballasts, and LTG -INT -SPACE rated watts per fixture; Identify spaces eligible for lighting power exemption on plans C405.5.1 C405.5.1.1 Total connected and in compliance forms; P N/A - _- Yes C405.5.1.2 interior lighting power Identify lighting equipment eligible for exemption in fixture NIA C405.5.1.3 schedule and in compliance forms; C405.5.1.4 N/A Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently Provide exit sign types and rated watts per fixture in fixture N/A NA C405.4 Exit signs schedule (maximum 5 watts per fixture) For lighting in walk -in coolers and freezers, and refrigerated NA C405.10 Cooler and freezer warehouse coolers and freezers, provide rated lamp efficacy (in - C405.11 lighting lumens per watt) in fixture schedule Lighting Power Calculation - Indicate compliance path taken Complete required compliance forms - proposed wattage per NA C405.5.2 Building Area Method building area does not exceed maximum allowed wattage per Attached building area. Identify locations of building areas on plans Complete required compliance forms - total proposed wattage Space -By -Space does not exceed maximum allowed wattage. Identify locations Yes C405.5.2 Method of space types on plans, including retail display areas as applicable EXTERIOR LIGHTING POWER & EFFICACY Section C405.6 Provide fixture schedule with fixture types, lamps, ballasts, and LTG -EXT rated watts per fixture; _. Total connected Identify exterior applications eligible for lighting power NIA Yes C405.6.2 exterior lighting exemption on plans and in compliance forms; power - Indicate that exempt exterior lighting is controlled independently N/A from non -exem pt exterior lighting Yes Table Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ LTG -EXT C405.6.2(1) For building grounds fixtures rated at greater than 100 w atts, NA C405.6.1 Exterior building provide rated lamp efficacy (in lumens per watt) in fixture grounds lighting schedule Complete required compliance form - proposed wattage for Yes C405.6.2 Exterior lighting exterior lighting plus base site allowed does not exceed Attached power calculations maximum allowed MOTORS & TRANSFORMERS (Sections C405.8, C405.9) For motors not part of an HVAC system, provide electric motor NA C405.8 Electric Motors schedule on electrical plans with hp, rpm, and rated efficiency Provide distribution transformer schedule on electrical plans NA C405.9 Transformers with transformer size and efficiency 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 2012 Washin ton State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address 2016 -09 RCDA Yelm High III Date 4/19/2016 1315 Yelm Ave_ West, For Building Dept. Use Yelm, WA 98597 Applicant Name: Modern Building Systems, Inc. Applicant Address: 9493 Porter Road, Aumsville, OR 97325 Applicant Phone: 503- 749 -4949 Project Description Briefly describe mechanical system type and features. D Includes Plans (9) 3.5 Ton Wall -hung (GAS) Heat Pumps and economizers. Drawings must contain notes requiring compliance with commissioning provisions per Section C408 Compliance Option Simple System O Complex System O Systems Analysis Equipment Schedules Ftheplans. llowing information is required to be incorporated with the mechanical equipment schedules on For projects without plans, fill in the required information below. Coolin g Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu /h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N A SPVHP Bard W42G3 -B 42000 Yes 10.0 EER - Econo N B SPVHP Bard W42G3 -B 42000 Yes 10.0 EER - Econo N c SPVHP Bard W42G3 -B 42000 Yes 10.0 EER - Econo N D SPVHP Bard W42G3 -B 42000 Yes 10.0 EER - Econo N E SPVHP Bard W42G3 -B 42000 Yes 10.0 EER - Econo N F SPVHP Bard W42G3 -B 42000 Yes 10.0 EER - Econo N G SPVHP Bard W42G3 -B 42000 Yes 10.0 EER - Econo N H SPVHP Bard W42G3 -B 42000 Yes 10.0 EER - Econo N J SPVHP Bard W42G3 -B 42000 Yes 10.0 EER - Econo N Heatin g E ui ment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu /h OSA cfm or Econo? Input Btuh Output Btuh Efficiency Heat Recovery Y/N A SPVHP Bard -Gas W42G3 -B 50000 Yes 61000 50000 82% EFF N B SPVHP Bard -Gas W42G3 -B 50000 Yes 61000 50000 82% EFF N C SPVHP Bard -Gas W42G3 -B 50000 Yes 61000 50000 82% EFF N D SPVHP Bard -Gas W42G3 -B 50000 Yes 61000 50000 82% EFF N E SPVHP Bard -Gas W42G3 -B 50000 Yes 61000 50000 82% EFF N F SPVHP Bard -Gas W42G3 -B 50000 Yes 61000 50000 82% EFF N G SPVHP Bard -Gas W42G3 -B 50000 Yes 61000 50000 82% EFF N H SPVHP Bard -Gas W42G3 -B 50000 Yes 61000 50000 82% EFF N J SPVHP Bard -Gas W42G3 -B 50000 Yes 61000 50000 82% EFF N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM SID HP /BHP Flow Controls Location of Service EF -1 Exh. Fan Panasonic FV -11VQ5 110 0.04 CV Restrooms EF -2 Exh. Fan Panasonic FV- 40NLFI 440 0.17 CV Restrooms ?n12 Washington State Enerav Code ComDliance Forms for Commercial, Group R1, and > 3 story R2 and R3 1 If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Economizer exception number per Service Water Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Input Capacity Sub - Category EF' Location of Service WH -50 WH Elect. AO -Smith ECT -52 <12kW Resist. 0.91 Restrooms 1 If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Economizer exception number per 2012'Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised .rune 2013 Project Address 2016 -09 KCDA Yelm High I I I Date 4/19/2016 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel orior to cirinting MECH -CHK pages. Applicability Code Section Code Provision Information Required Location Building Department (yes,no,na) on Plans Notes GENERAL PROVISIONS Equipment Sizing & Performance Yes C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Attached Chapter 3 Equipment and system Output capacity of heating and cooling equipment and systems do not Yes C403.2.2 sizing exceed calculated loads note exceptions taken Ventilation (natural or mechanical) provided per IMC; indicate mechanical Yes C403.2.5 Minimum ventilation ventilation is capable of being reduced to minimum requirement per IMC A0.0 & M 1.0 C403.2.3 & Provide equipment schedules or complete MECH -SUM tables with type, C403.2.3.2 & Equipment minimum capacity, efficiency, test standard (or other efficiency source) for all Yes C403.2.12.1 efficiency mechanical equipment MECH -SUM N/A C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note - except. Fan system motor hp or bhp does not exceed limits per Table N/A C403.2.10 Fan power limitation C403.2.10.1 1 - C403.2.10.3 hp fan Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency N/A & C403.2.13 Fractional motors re q. N/A C403.2.3 Maximum air cooled chiller Indicate air - cooled chiller capacity does not exceed air - cooled chiller limit - ca capacity Non - standard water - cooled Full -load and NPLV values forwater - cooled centrifugal chiller adjusted for N/A C403.2.1 chillers non- standard operational conditions - Centrifugal fan cooling Large capacity cooling towers with centrifugal fan(s) meet efficiency N/A C403.2.12.1. towers requirements for axial fan open circuit cooling towers - C403.2.3 Forced air fumace and unit Indicate intermittent ignition or IID, flue /draft damper &jacket loss - N/A heaters Yes C403.2.3.3 Packaged electric List equipment required to be heat pumps on schedule M1.0 heating/cooling equipment Indicate method of humidification (note requirements for systems with N/A C403.2.3.4 Humidification economizer)- HVAC System Controls & Criteria Yes C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including M1 enmeter systems .0 Yes C403.2.4.1.1 Heat pump supplementary Indicate staged heating (compression /supplemental) & outdoor lock -out T -stat Specs heat tern Yes C403.2.4.2 Setpoint overlap Indicate 5 °F deadband minimum for systems controlling both heating & T -stat Specs deadband cooling Automatic setback and Indicate zone t -stat controls with required automatic setback & manual Yes C403.2A.3 shutdown override T -stat Specs Yes C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load T -stat S eCS conditions p C402.4.5.2 & Dampers Indicate location of OSA, exhaust, relief and return air dampers; include A0.0 & M1.0 Yes C403.2.4.4 AMCA rated leakage and control type motorized or ravit note N/A C403.2A 1 Heating outside a building Indicate radiant heat system and occupancy controls - N/A C403.2A.5 Snow melt systems Indicate shut -off controls based on outdoor conditions - N/A C403.2A.6 Combustion heating Indicate modulating or staged control - equipment N/A C403.2.4.7 Group R1 hotel /motel Indicate method for guest room automatic setback & set -up of 5 °F systems minimum N/A C403.2.4.8 / S Group R2 /R3 dwelling unit Indicate 5 -2 programmable thermostats in primary spaces with minimum of - systems two setback eriods note exceptions taken N/A C403.2.5.1 Demand controlled Indicate high- occupancy spaces and systems requiring DCV - ventilation Yes C403.2.5.2 Occupancy sensors p y Indicate spaces requiring occupancy -based system control and method; or T -stat Specs alternate means provided to automatically reduce OSA when artiall Enclosed loading Indicate enclosed loading dock and enclosed parking garage ventilation N/A C403.2.5.3 dock/parking garage system activation and control method - ventilation N/A C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requir ng make -up air; indicate make -up air source - and conditionin method Indicate lab exhaust systems requiring heat recovery, method & efficiency; C403.2.5.4.2 Laboratory exhaust systems or altemative method taken (VAV, semi-conditioned makeup, or CERM N/A calculation)- Energy recovery - Indicate ventilation systems requiring ER, method & efficiency; note N/A C403.2.6A ventilation systems exceptions _ N/A C403.2.6.2 Energy recovery - Indicate on -site steam heating systems requiring energy recovery - condensate s stems N/A C403.2.6.3 Energy recovery - Indicate remote refrig. condensers requiring ER and use of captured - condensers stems ener Mechanical P- rmit Plans Checklist - Page 2 of 2012'Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address 2016 -09 KCDAYelm High III Date 4/19/2016 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH -CHK pages. Applicabildy Code Section Code Provision Information Required Location on Plans Building Department Notes (yes,no,na) GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued Variable flow control - Indicate fan & pump motors requiring VF control & method (VSD or equiv N/A C403.2.12 fans/pumps controls C403.2.12.1 Variable flow control - Indicate cooling tower fans requiring variable flow control and method _ N/A cooling towers Indicate fan systems requiring airflow reduction based on heating and N/A C403.2.12.2 Large volume fan systems cooling demand; or exception taken - Indicate method of cooling demand -based fan control for sys. > 110,000 C403.2.12.2 Single zone AC systems btuh N/A _ Identify all DDC system input/output control points and indicate capability N/A C403.2.4.10 DDC system capabilities Ducting Systems C403.2.7.1 & Indicate all ductwork constructed and sealed per IMC, C402 leakage N/A C403.2.7.3 Dud construction requirements and IBC vapor retarder requirements 403.2.7.3.1- Dud pressure Identify location of low, medium and high pressure ductwork on plans M1.0 Yes classifications High pressure duct leakage Indicate high pressure dud leakage testing requirements on plans, provide N/A C403.2.7.3.3 test test results to jurisdiction when completed - Yes C403.2.7.1 ! Dud insulation Indicate R -value of insulation on ductwork M1.0 Piping Systems N/A C403.2.8 Piping insulation Indicate R -value of insulation on piping _ N/A C403.2.8.1 Piping insulation exposed to Indicate method of protection from damage /degredation _ weather SIMPLE SYSTEMS Qualifying Systems C403.3 Qualifying single zone Verify unitary or packaged equipment does not exceed capacity limits, does Mech Unit Specs Yes systems not have active humidification or simultaneous heating/cooling C403.3 Qualifying 2 -pipe heating Verify 2 -pipe heating -only system does not exceed capacity limits _ N/A systems N/A C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 _ Simple System Economizers C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip M1.0 Yes shed. Yes C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception A0.0 C403.3.1.1.3 Air economizer high limit Indicate high limit shut -off control method per Table C403.3.1.1.3(2) A0.0 Yes controls Integrated air economizer Indicate capability for partial air economizer operation for systems with N/A C403.1.1.2 o eration ca acit > 65,000 btuh - Indicate eligible exception(s) taken and provisions to comply with N/A C403.3.1 Air economizer exceptions - COMPLEX SYSTEMS Complex System Economizers Indicate cooling systems requiring economizer controls, note in equip N!A C403.4.1 Air economizer required sched. - Economizer heating system Verify control method of HVAC systems with economizers does not N/A C403.4.1.4 impact increase building heating energy usage during normal operation _ Integrated economizer Indicate capability for partial economizer operation for air or water econo N/A C403.4.1.3 o eration systems - Indicate water econo capable of 100% cooling capacity at 50 °F db /45 °F wb N/A Moved Water economizer capacity OSA - Water economizer Indicate precooling coils and heat exchangers do not exceed pressure drop N/A C403.4.1.2 maximum pressure drop limit - Indicate eligible exception(s) taken and provisions to comply with N/A C403.3.1 Air economizer exceptions Mechanical Permit Plans Checklist - Page 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 201 Project Address 2016 -09 KCDAYelm High III Date 4/19/2016 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH -CHK pages. Al plicabilty Code Section Code Provision Information Required Location on Plans Building Department Notes (yes,no,na) COMPLEX SYSTEMS, CONTINUED Specific System Requirements N/A C403.4.2 & Variable flow control - fans Indicate fans requiring variable flow control and method C403.2.12 VAV fan static pressure Indicate sensor locations on plans, include at least one sensor per major N/A C403.4.21 sensors dud branch - VAV fan static pressure Indicate fan system static pressure setpoint based on zone requiring most N/A C403.4.2.2 setpoint pressure Indicate supply air systems serving multiple zones that are required to be C403.4.5 VAV systems serving multi- VAV, method of primary air control, and zones served, note exceptions N/A zones taken - to controls that automatically reset supply air temp in response to N/A C403.4.5.4 VAV system supply air reset loads - Large capacity cooling Indicate method of multi -stage or variable control for building cooling N/A C403.4 systems system capaoity capacity > 300 tons - N/A C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method _ N/A C403.4.3 Large capacity boiler s stems Indicate multi -stage or modulating burner for single boilers > 500,000 btuh _ N/A C4014.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers _ Chiller / boiler plant pump Indicate capability to automatically reduce overall plant flow and shutoff N/A C403.4.3.5 isolation flow through chillers & boilers when not in use - N/A C403.4.2 & C403.4.3.6 Variable flow control - pumps Indicate pumps requiring variable flow control & method - C403.2.12.1 Variable flow control - Indicate cooling tower fans requiring variable flow control and method N/A & C403.4.4 cooling towers Hydronic system part load Indicate heating & chilled water systems have the capability to automatically N/A C403.4.3.4 controls reset supply water temp AND reduce flow by ? 50% fors stems > 300,000 - Two -pipe changeover Indicate deadband, heating /cooling mode scheduling and changeover N/A C403.4.3.2 systems temperature range Water loop heat pump - Indicate capability of central equipment to provide min. 20 °F water supply N/A C403.4.3.3.1 deadband temp deadband between heat rejection and heat addition modes - Water loop heat pump - Provide heat exchanger that separates cooling tower and heat pump loop N/A C403.4.3.3 heat re edion in Climate Zone 5 Water loop heat pump - Indicate 2 -way isolation valve on each heat pump and variable flow control N/A C403.4.3.3.3 isolation fors stems with total pump power > 10 hp - I N/A C403.4.6 Condenser water heat Indicate system provided to pre -heat service water and efficiency _ recovery Cooler / freezer - anti -sweat Indicate w /sf & control method for walk -in cooler /freezer door anti -sweat N/A C403.5 heaters heaters N/A C403.5 / 6 Cooler / freezer - evaporator Indicate motor type for evaporator and condenser fans < 1 hp - SERVICE WATER HEATING Service Water Systems C404.2 Water- heating equip min. Provide equipment schedule or complete MECH -SUM table with type, MECH -SUM Yes efficient ca a ity, efficiency, test standard or other efficient source Yes C404.3 Temperature controls Indicate temperature controls have required setpoint capability P1.0 Indicate piping connected to equipment have heat traps on supply & P1.0 Yes C404.4 Heat traps discharge C404.5 Insulation underwater Indicate R -10 insulation under tank _ N/A heater C404.6 Service water piping Indicate R -value of insulation on piping, note exceptions taken P1.0 Yes insulation Circulation systems and Indicate shutoff capability based on occupancy and periods of limited N/A C404.7 / g heat trace shut -off demand - Group R -2 service hot water Indicate method of usage metering for dwell. units served by central HW N/A C404.9 Imeters - Pools & In- Ground Permanently Installed Spas Provide equipment schedule or complete MECH -SUM table with type, C404.10.1 Pool heating equip min. capacity, efficiency, test standard (or other eff. source), heat pump heaters N/A efficiency > 4 COP Indicate automatic on /off control based on scheduling & accessible on /off N/A C404.10.1 / 2 Pool heater on / off controls switch on heater that operates independent of thermostat setting; or - N/A C40410.3 Pool covers Indicate vapor retardant cover and insulation rating as required _ N/A C40410.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90 °F _ Indicate method, exhaust air temperature reduction and recovered energy N/A C404.10.4 Heat recovery ]use - I Air Handler #1- Two Lennox 5 Ton Split Sytem Heat Pumps Total Load Summary Air Handler Description: Two Lennox 5 Ton Split Sytem Heat Pumps Constant Volume - Proportion Supply Air Fan: Blow -Thru with program estimated horsepower of 1.1 u hr Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.78 -- This system occurs 1 time(s) in the building. — Air System Peak Time: 4pm in July. Outdoor Conditions: Clg: 88° DB, 67° WB, 66.47 grains, Htg: 21° DB Indoor Conditions: Clg: 75° DB, 50% RH, Htg: 72° DB Summer: Ventilation controls outside air, - - -- Winter: Exhaust controls outside air. Zone Space sensible loss: 107,061 Btuh Infiltration sensible loss: 0 Btuh Outside Air sensible loss: 334,418 Btuh Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: Total Heating Required With Outside Air: 441 479 Heating Supply Air: 107,061 / (.986 X 1.08 X 16) _ Winter Vent Outside Air (100.0% of supply) _ Zone space sensible gain: 271,577 Btuh Infiltration sensible gain: 0 Btuh Draw -thru fan sensible gain: 0 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: Cooling Supply Air: 271,577 / (.986 X 1.1 X 20) _ Summer Vent Outside Air (22.2% of supply) _ Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 39,239 Btuh Blow -thru fan sensible gain: 2,957 Btuh Total sensible gain on return side of coil: Total sensible gain on air handling system: 0 CFM 6,160 CFM 6,160 CFM 6,160 CFM 12,524 CFM 2,784 CFM 2,784 CFM 441,479 Btuh 271,577 Btuh 42,197 Btuh 313,774 Btuh Zone space latent gain: 76,204 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 2,284 Btuh Total latent gain on air handling system: 78 487 Total system sensible and latent gain: 92,261 Btu Total Air Handler Supply Air (based on a 20° TD): 12,524 CFM Total Air Handler Vent. Air (22.23% of Supply): 2,784 CFM Total Conditioned Air Space: 8,283 Sq.ft Supply Air Per Unit Area: 1.5121 CFM / Sq.ft Area Per Cooling Capacity: 253.4 Sq.ft/Ton Cooling Capacity Per Area: 0.0039 Tons /Sq.ft � Heating Capacity Per Area: 53.30 Bt h /Sq.ft O OR Total Heating Required With Outside Air: 441 479 Btu usF'C9� 3 S -M Total Cooling Required With Outside Air: 32.69 ons . 14 (/& : 3 I. r Twlr s \\ DISKSTATION \Desgin\Don\CHVAC_Area- 1\2016 -09 Yelm High School.CHV Tuesday, April 19, 2016, 10:09 AM THE WALL- MOUNTTm GAS /ELECTRIC Climate Control Solutions Models: W24G3 to W60G3 Up to 10.5 EER GREENREFRIGEF 26,000 to 57,500 BTUH Cooling Capacity 34,000 to 102,500 BTUH Heating Capacity 1 The Bard Wall -Mount Electric Air Conditioner with gas fired heating is a self- contained energy efficient system which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, portable structures, correctional facilities, retail stores or other commercial applications. Factory or field installed accessories are available to meet specific job requirements. Features Eno*" Air Conditioner Compressor: Pre - Painted 20 Gauge Zinc Coated Scroll compressors are used on all models Steel Cabinet: and no crankcase heaters are required. Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The R-410A Refrigerant: cabinet is handsomely finished with a Designed with R-410A (HFC) non -ozone baked on textured enamel, which allows depleting refrigerant in compliance with it to withstand 1000 hours of salt spray the Montreal protocol and 2010 EPA tests per ASTM B117 -03. requirements. Liquid Line Filter Drier: Protects system against moisture. Aluminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. High & Low Pressure Switches are Auto- Reset: Built -in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Compressor Control Module: Standard on all units. Built -in off -delay timer adjustable from 30 seconds to 5 minutes. 2- minute on -delay if power interrupt. 120 - second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. Phase Rotation Monitor: Standard on all 3 phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Twin Blowers: Move air quietly. All models feature multispeed blower motors providing airflow adjustment for high and low static operation. Electrical Components: Are easily accessible for routine inspection and maintenance through a right side service panel opening. Features a lockable, hinged access cover to the circuit breaker. 16 Gauge Zinc Coated Unit Base. Heat Exchanger. Heavy duty 18 -gauge stainless steel tubular heat exchanger. Mechanically joined construction. Ten -year warranty. In -Shot Burners: Advanced burner design, quiet operation. Built -in Circuit Breakers: Standard on all single (230/208 volt) and three phase (230/208 volt) equipment. Toggle disconnects are standard on all three phase (460 volt) equipment. Integrated DSI Control: Direct spark ignition control and remote sensor delivers smooth, proven ignition sequence. Timed blower control and diagnostics are also features of integrated control. Gas Controls: Honeywell gas valve and burner orifices are factory standard for natural gas. High altitude kits available. Field convertible to LP gas with certified conversion kit. Filter Service Door: Separate service door provides easy access for filter change. Condenser Fan and Motor Shroud Assembly: Slides out for easy access. Air Filters: Two-inch pleated air filters are standard equipment. Optional 1 -inch washable filter available. Factory or field installed. Barometric Fresh Air Damper: Standard on all units. Allows up to 25% outside fresh air. Ventilation Options: Several ventilation options are available and can be factory or field installed. Slope Top: Standard feature for water run -off. Top Rain Flashing: Standard feature on all models. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Evaporator Freezestat: Standard on dehumidification models. • Complies with efficiency requirements of ANSI /ASHRAE/IESNA 90.1 -2010. a Certified to ANSI /ARI Standard 390 -2003 for SPVU (Single Package Vertical Units). Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI /UL 1995 /CSA 22.2 No. 236 -05, Fourth Edition. • Intertek ETL Listed to Standard for Gas -Fired Central Furnaces ANSI Z21.47 -2006, CSA 2.3 -2006 Fifth Edition, Addenda A dated 10 -01 -2007, Addenda B dated 06 -01 -2008. Commercial Product - Not intended for Residential application. t�tl[RY,px. C us Intertek Form No. 53500 -615 Supersedes NEW Page 1 of 16 _r Operating Voltage Range 197 -253 187 -253 414 -506 197 -253 187 -253 414 -506 197 -253 187 -253 414 -506 Minimum Circuit Ampacity 21 16 10 23 17 11 27 20 11 *Field Wire Size 10 12 14 10 12 14 8 14 Ground Wire Size 10 12 14 10 12 14 10 10 14 ** Delay Fuse - Max. 30 25 15 35 25 15 40 25 15 ornpressor Voltage 230/208 230/208 460 230/208 2301208 460 230/208 230/208 460 Rated Load Amps 9.9/10.9 6.4/7.1 3.9 11.8/12.9 7.5/8.2 4.7 12.4/14.0 7.8/8.8 4.9 Branch Circuit 12.8 8.3 5.1 141 9 5.6 16.7 10.5 5.8 Selection Current Lock Rotor Amps 64/64 58/58 28 77!77 71171 38 79/79, 73/73 38 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll an Mofpr & Corxinnser ti, _ a >:;. Fan Motor -HP- RPM -SPD 1/5- 1050 -1 � 1/5- 1050 -1 1/5 -105 0 1 1/5 1050 -1 1/5 1050 1 1/5-1050-1 1/5 -1050 1 1/5-1050-1 1/5-1050-1 Fan Motor -Amps 1.5 120' 1.5 8 1.5 120 1 1.5 8 120 1.5 1.5 .8 Fan D1A/CFM 20 2400 - 2400 20 2400 2400 20 2400 20 - 2400 2400 20 - 2400 201-2400 Blower Motor HP -RPM -SPD 1/4 -950 -3 1/4 -950 -3 1/4 -950 -3 1/3- 1075 -3 1/3-'1'075-3 1/3- 1075 3 1/3- 1075 -3 1/3- 1075 -3 1/3- 1075 -3 Blower Motor -Amps 1.8 1.8 .8 2.2 2.2 1.1 2.2 2.2 1.1 CFM Cooling & E.S.P. 800-15 .15 800 - .15 800-15 .15 1000 - .35 1000 - .35 1000 1000-35 1100-25 .25 1100 - .25 1100-25 Filter Size 20x25x2 20x25x2 20x25 x2 20x25x2 20x25x2 20x25x2 20x25x2 20x25x2 20x25x2 30k 3 PE�c J *Based on 75'C copper wire. All wiring must conform to the National Electrical Code and all local codes. 35A t p C -L& * *Maximum time delay fuse or HACR type circuit breaker. Form No. S35OG -615 Supersedes NEW Page 2 of 16 Input 90,000 81,000 68,000 61,000 45,000 41,000 Output 74,000 66,500 55,500 50,000 37,000 34,000 Thermal Efficiency (T.E.) 82.0 82.0 82.0 82.0 82.0 82.0 Temp. Rise Range 50-80 W24G3; W30G3 W35G3` -' W42G3 W48G3' ) W60G3` s Capacity BTUH ® 26,000 32,000 940 35,000 42,000 48,000 57,500 COW 10.0 10.0 730-1275 10.2 10.0 10.5 10.1 EER m 800 1000 Mid -Rise Range Airflow 1100 1300 1550 1650 Rated CFM Airflow Range 680-920 850-1150 935-1265 1030 - 1500 1280 - 1750 1340-1910 Acceptable 90,000 90,000 1120 90,000 125,000 125,000 125,000 68,000 68,000 1290 68,000 100,000 100;000 100,000 Available Heating Inputs ® 45,000 45,000 790 45,000 75,000 75,000 75,000 1030 D Capacity is cert'rfied in accordance with ANSI/P RI Standard 390 -2003. .40 1150 990 ® EER = Energy Efficiency Ratio and is certified in accordance with ARI Standard 390 -2003. 1190 1030 1190 All ratings based on fresh air intake being 100% closed (no outside air introduction). 860 .50 910 710 0 Any one of the heating inputs shown is available for each basic cooling model as indicated. Each input can be field derated 10% from factory standard and main burner orifices are included with each unit to accomplish this. See table below for additional information. .50 Input 90,000 81,000 68,000 61,000 45,000 41,000 Output 74,000 66,500 55,500 50,000 37,000 34,000 Thermal Efficiency (T.E.) 82.0 82.0 82.0 82.0 82.0 82.0 Temp. Rise Range 50-80 50-80 40-70 40-70 25-55 25-55 Mid -Rise Range Airflow 1040 940 925 825 830 740 Acceptable Airflow Range 845-1350 765-1220 730-1275 650 - 1135 610-1330 540-1185 Heating ratings certified in accordance with ANSI 221.47 -2006_ 40-70 30-60 30-60 Mid -Rise Range Airflow 1410 Heating ratings certified in accordance with ANSI 221.47 -2006. t t t 1 t t! t E ! ! 4.1 ` W24G cooling airflow is rated 800 CFM 0 .15 ESP, and wet coil range is 700 - 910 CFM. W30G cooling airflow is rated 1000 CFM 0 .35 ESP, and wet coil range is 880 - 1150 CFM. See Heating Airflow Ratings Chart for heating details. See Heating Airflow Ratings Chart for heating details. .10 gar stoma ale Fmys`tanaa<ae1a tlerate fir saa ate Input 125,000 113,000 100,000 90,000 75,000 68,000 Output 102,500 93,000 82,000 74,000 61,500 56,000 Thermal Efficiency (T.E.) 82.0 82.0 82.0 82.0 82.0 82.0 Temp. Rise Range 50-80 50-80 40-70 40-70 30-60 30-60 Mid -Rise Range Airflow 1410 1270 1365 1230 1250 1135 Acceptable Airflow Range 1145-1830 1 1030 - 1650 1075 - 1875 965-1700 940-1875 850-1700 Heating ratings certified in accordance with ANSI 221.47 -2006. t t t 1 t t! t E ! ! 4.1 ` W24G cooling airflow is rated 800 CFM 0 .15 ESP, and wet coil range is 700 - 910 CFM. W30G cooling airflow is rated 1000 CFM 0 .35 ESP, and wet coil range is 880 - 1150 CFM. See Heating Airflow Ratings Chart for heating details. See Heating Airflow Ratings Chart for heating details. .10 820 1260 1060 1060 870 .10 10001 1260 1 10601 1260 1 1060 .20 950 770 1200 1010 1200 1010 .20 1160 950 1370 1200 1 1010 1200 1010 .30 880 700 1120 1120 940 .30 1080 880 1290 1120 940 1120 940 .40 790 1030 1030 860 .40 1150 990 1190 1030 1190 1030 860 .50 910 710 950 .50 1050 910 1090 950 1090 950 .60 800 840 .60 940 980 980 840 ESF 00 mg Mode Iv1Aif{1ALFANand HEATING MODE ESP Cooling "Mode 11 MANUAi FAN and 'HEATI+jG MODE: inches Wet Oo[I 6$,000 BTU input', 61;000 BTU Input Inches Wet Cdjl 68,000 BTU Input::. 61,000 BTU, ]nput , HzQ Higti, Med Med Ldw high`' Med ` Low Hz0 High : Low High ; law; tilgh `Me`d . ;Low .10 820 1260 1060 870 1060 870 .10 1000 1260 1060 1060 .20 950 770 1200 1010 1010 810 .20 1160 950 1200 1010 1010 .30 880 700 1120 910 1120 940 .30 1080 880 1120 940 1120 940 .40 790 1030 1030 860 .40 1150 990 1190 1030 860 1030 860 .50 910 710 950 950 780 .50 1050 910 1090 950 780 1090 950 780 .60 800 840 .60 940 980 840 980 840 660 ESP MANUALfANand HEATING MODE ESp Oooling Mode MANIJAt FAN and hEATI.tJ6 Mi3OE " inches 45O(i0 BTUtnp .. 41, OD BTII input ncs Wetol , p. ;BTU InputHZO Med idw High = Med :: low HzO: High .10 it 1260 1060 870 1660 870 .10 1000 1260 1060 1060 .20 1200 1010 810 1200 1010 810 .20 1160 950 1200 1010 1200 1010 .30 1120 910 1120 940 750 .30 1080 880 1290 1120 940 1120 940 .40 1030 860 1030 860 680 .40 1150 990 1190 1030 860 1030 860 .50 910 710 950 780 950 780 .50 1050 910 1090 950 780 1090 950 780 .60 800 1 840 840 .60 940 980 840 1 660 1 980 840 1 660 Voltage adjustment - Reduce airflow by 100 CFM for 208 Volt Voltage adjustment - Reduce airflow by 100 CFM for 208 Volt Dehumidification coil adjustment - Reduce airflow by 35 CFM for dehumidification coil installed Dehumidification coil adjustment - Reduce airflow by 35 CFM for dehumidification coil installed Top outlet adjustment - Increase airflow by 50 CFM for top outlet models Top outlet adjustment - Increase airflow by 50 CFM for top outlet models SG -3, RG -3, non - ducted application adjustment - Reduce airflow by 100 CFM for SG -3 SG -3, RG -3, non -ducted application adjustment - Reduce airflow by 100 CFM for SG -3 and RG -3 installations and RG -3 installations Form No. S3500-615 - Supersedes NEW Page 3 of 16 4 25 4. 'P f-- C-1 L Cif w CM rC 04 z ir., L a� 1.4 ti M z tta > ix 0 L C) ED, 4:71 > U5 0 ;r- tv i 1,4 '3 CA !Te-9 11-1 rn Va > ilz G! > iw#O Ge 04 z ir., L a� 1.4 ti O J LOY z 0.0 TZ LA Yt CO m M X. M. m W M z tta ix 0 L C) ED, 4:71 CO '3 Va ilz G! O J LOY z 0.0 TZ LA Yt CO m M X. M. m W ztt�io�s A Item 1 Of 4 1 Next Product Into Literature VisionPRO® 8000 with Red LINKTM technology for residential or commercial use PmtPace 1 1 SHARE 3 a• TH8321R1001JU VisionpRM 8000 with Red LI 1K"-' technology for residential or commercial use. Stages up to Up to 3 beat 12 Cool. Accessories & Replacement Parts Overview VisionP 09.8000 with RedLINKT"' is a 7 dayprogramnmable touenscreen thermostat that is selectable for residential or dgttt c om nerciat use. The thermostat can be wired directly to the equipment, used with the THM5421 R 1021 Equipment Interlace Module or used with the THM4000R1000 TrueZONE Wreless Adapter, Works with the RedLINKT° accessories including the RedLINKTf1 Internet Gateway, Portable Comfort Control, Wreless Outdoor Sensor. Wireless indoor Sensor, Wreless Enhy/ExitRemote and Wreless Vent and Filter Boost Remote. Features • Thermostat works standalone or Wth the THM5421R1021 Equipment Interface Module or with the TrueZONE Wreless Adapter, • Smart Schedule - programs in seconds for any lifestyle. • Patented interview based programming and installer setup. • RedLINK"-1 wireless communication. • Increase profit per job by including RedLINKT}" accessories that provide comfort and convenience. RedLINKT' accessories include the RedLINKT"' Internet Gateway, Portable Comfort Control (PCC), Wireless Outdoor Sensor, Wireless IndoorSensw, Wireless Entry/Exit Remote, Wireless Vent and Filter Boost Remote, TrueSTEAM 110 humidifier with Wireless Adapter and TrueZONE@ zoning panel with Wireless Adapter. • Selectable for residential and light commercial applications. Meets commercial code and is title 24 compliant. • Light commercial - commercial language (occupied and unoccupied), schedule holidays and custom events, remote setback, economizer and time of day. Remote Setback requires the THM5421RIO21 Equipment Interface Module. • Plain language setup, no manual needed. • Alerts and User Interactions Log - Keeps a searchable history of alerts and setting changes to the thermostat to determine if there is a system malfunction or if the issue was caused by a user error. Saves time in troubleshooting and points the technician in the right direction. The Alert and User Interaction Logs are viewable on a computer after you download them from the thermostat to a microSD card. • Customizable Service Reminders allow dealers to remind their customers when its time to call for service, when their warranty is expiring and to provide customized alerts. • MicroSD port for copying the Installer Setup, Customizable Reminders, Custom Events and Holidays to multiple thermostats. • MicroSD port for adding the dealer's contact information on the screen. • 1 assignable output on the TH8321 model to control humidification, dehumidification, ventilation or a stage of heating /cooling. • 3 assignable outputs on the Equipment interface Module to control humidification, dehumidification, ventilation or a stage of heating /cooling. The TH8110 and TH8320 models require the use of a Wireless Indoor Sensor to control humidification and dehumidification. • 1 assignable input can be used with a wired outdoor; indoor or discharge sensor. • 4 assignable inputs on the. Equipment Interface Module can be used with 1.Vred outdoor, indoor or discharge sensors, occupancy sensor for resole setback and dry contact devices to trip pre- packaged or custom alerts such as a full drain pan or water leak. • Extend wireless range of the Equipment Intetace Module by connecting a THM4000R1000 Wireless Adapter to the ADCD tenninals: • Dual powered battery or hardwired (C Wre). • Precise temperature control ( +l- 1` F) for reliable and consistent temperature. • Multiple staging options to provide comfort or energy savings. Product Specifications Hazmat lnformafton UN 3091 Lithium metal batteries packed iniwith equipment Application Up to 31-112C heat pump or up to 2Iir2C conventional Dimensions (in.) 4 518 in. High; 4 15,116 in. Wde,1 118 in. Deep Dimensions (min) 118 mm. High, 126 mm. Wde, 29 rnm. Deep Includes VisionPRO@ 8000 thermostat Used With Works standalone orwith optional TI IM5421 R1021 Equipment Interface Module and RedLINKT' accessories. Item Type Product tlttps :llcustorner.honeywell.com /en -US /pages /Pi-oduct.aspx? cat= HonECC %2OCatalog &pid= TH8321R 1001 /U W Y 1 a-,* 7102015- Electrical Relinas Frequency Stages Electrical Connections Operating Humidity Range ( RH) Supply Voltage Switch Positions (Systern) Switch Positions (Fan) Operating Temperature Range (F) Operating Temperature Range (C) Color Programmability Power Method Terminal Designations Display Size Chenueover Setting Temperature Range (F) Setting Temperature Range (C) Humidification Setting Range Dehumidification Setting Range terms & conditions I privacy statement I site map VSIonPROO 8000 with Redl-INKTI' technology for residential or commercial use 18 to 30 Vac or 750 mV 50 Hz, 60 Hz Up to 3 Flea! 12 Cool Heat Pump or Up to 2 Heat 12 Cool Conventional when used standalone; Up to 4 Heat / 2 Cool Heat Pump of Up to 3 Heat /2 Cool Conventional when used with the Equipment Interface Module. Screw- terminals 5 to 90% RH, non - condensing 18 to 30 Vac or 750 rr:V HEAT- OFF - COOL- AUl'O -E:M.H EA T AUTO- ON- CIRC,FOLLOW SCHEDULE 32 F to 120 F 0C to48.9C Arctic tNhite 7 -Day Multiple Day Programming or Non - Programmable Battery or Hardwired R, RC, C: W-O /B. V,12- AUX/E, Y, Y2, G, A -LA, K, U 1 U1, S1 S1 10 sq in. Auto or tvlanual Heal: 40 F to 90 F Cool 50 F to 99F Heat: 4.5 C to 32L C. Cool: 10 C to 37.0 C Cooling: 40 to 30% Rf L Heating: 10 to 60:i. PH, 40 to 80% RH. tits"! r lkwatn choose region & language honeywell international inc. 2015 https:Jtcustomer.ttoneywell .coin/en- USlpages/Product.aspx? cat= HonECC %20Catalog&pid= TH8321R10011U 212