20150238 (01-15-16) Concrete Report #02 - 28 Days 11
GONSTRUC 'ION TESTING LN-10RATORIES, INC. Qw
400 Valley Avenue NE, Suite 102 Puyallup,WA 98372
www.ctiwa.com Telephone (253) 383-8778
Facsimile (253) 770-8232
CONCRETE (4x8) CYLINDER
CONCRETE INSPECTION& TEST REPORT E T
UAT OF
CLIENT_ Yelm Communit Schools _ _INSPECTION_ Januai 1 S, 20I G
-PROJECT Mill Pond Elementary School Playshed BUILDING N/A�,_
TITLE PERMIT N0.
___________
__________
_ ADDRESS 10605 Mill Road SE Yelm, WA REPORT _ 02
CONTRACTOR Western Washington Construction LLC PROJECT 6027
NUMBER 1101500118
WORK CONTRACT REFERNCE 30B p,0.Nb.
ORDER NO. ORDER NO. ORDER NO. ORDER
INSPECTED Yes INSPECTED Yes
METHODOF METHODOF
PLACEMENT_ Truck Chute CONSOL7oAT.0N Mech. Vibrator
LACEM€ T _
CONCRETE Miles S&G EsnM)PLACE 1O o 16 YARD(5)
5UPPLIER yARDtS)PLACEO
LOCATION
or Four ootings, pla, he
PLACEMENT
LOCATION 2nd footing south of north side of shed.
SAMPLED 7�T
CEMENT 4.g CEMENT Vic MTRTAR N1A AGG. /JJ SLUMP 4 MJ) AIR nA N/A 0/0. ..
SACK
__ _______ _ ____
MIX DATA MIX# 1840OF
ADMIXTURE A4 Ash AMOUNT 64 Ibsl ds3 a
ADMIXTURE AMOUNT
Hot Water 100 % I TRUCK
'TEMPERATURE CONCRETE 66 l' . TEMPERATURE 3 F i NUMBER 1Y106/ WEATHER Claud
_____________ ______�_________--- p ______,_-__-_______ ________________
#SPECIMENS Jr TIME 00.50 HR TICKET 219774 DESIrX STRINTN 3000 PSI
CAST SAMPLED NUMBER REQUIRED
CYL.NO. LAS NO. DATE TESTED AGE AREA AVG.PIA. Break Type L DIMENSIONS TOTAL LOAD PSI
9A 0268 0112212016 : 7 12.56ii,2 4.00 5 4" x 8" 42935 3420
9B 0269 ; 0211212016 28 ; 12.69in2 4.01 4 65255 5140
9C 0270 0211212016 28 ; 12269in2 ; 4.01 4 67760 5340
k
9D 0279 0211212016 ; 28 ; 12.69M2 1 4.01 i 4 64710 5100
9E 0272 HOLD H i
NOTE: El PER ASTM®C-31,®C-143,N C-172,❑C-231,M C-1064,®C-39,El C-617,&®C-1231. TESTS PER AASHTo El T-22,❑T-23,
❑T-119,❑ R-60,❑T-152,❑T-231&❑T-309.
NOTE: Total hours until specimens transported to laboratory_77_,
FIELD N/A RESULT(S)STATUS W
It
TYPE I TYPE 2 TYPE 5
Well formed cone TYPE 3 'r}'PE 6—
Reason-Ably well TYPE 4 Side fractures at
on one end,vertical Cal unlnar rerticai Similar to type �0 �� �y
formed cones on Diagoua]fracture lop or bottom V\
BREAJ5 cracks running cracking through 5 but end of both ends,less than with no cracking (occurs commonly
TYPE, f"Df cracking through caps,cone both ends,no s. through end. with un-bonded cylinder.
through caps well defined cone vn farmed canes. caps) pointed.
other end.
LAB
NIA
REMARKS 1 Y 1 i _
OFFICE N/A T
REMARKS / T]
DATE Jan. 18, 2016 �,68Y Nancy ]N5PECTOR G. L+� d/x171 by�ewed D. Smith
REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL,WITHOUT THE WRITTEN APPROVAL OF THE LABORATORY. REPORT PERTAHIS ONLY TO THE MATERIAL TESTED free.IWOtl75)