20170203 Permit Pkg 06122017City of Yelm
Community Development Department
Building Division
Phone: (360) 458 -8407
Fax: (360) 458 -3144
Applicant:
Name: SOUNDBUILT NW LLC
Address: PO BOX 73790
PUYALLUP WA 98373
Property Information:
Site Address: 14526 98TH WAY SE
Assessor Parcel No.: 78640101300
Contractor Information:
Name: SOUNDBUILT NW LLC
Address:
PO BOX 73790
PUYALLUP WA 98373
Contractor License No.: SOUNDHL831 CL
Project Information:
Project: NEW RESIDENTIAL BUILDING
Description of Work: LOT 13, PLAN 2603A
Sq. Ft. per floor: First 1262
Second 1336
Third
Garage 414
Basement
Fees:
Item
NEW RESIDENTIAL BUILDING
MECHANICAL
PLUMBING
Subdivision:
Permit No.: 20170203
Issue Date: 6/12/2017
(Work must be completed within 180 days)
Phone: 253 - 848 -0820
Owner: SOUNDBUILT NW LLC
TAHOMA TERRA Lot: 13
Phone:
Expires: 2/13/2019
Heat Type (Electric, Gas, Other)
GAS
Contractor Fees
SOUNDBUILT NW LLC $22,975.66
SOUND HEATING & AC $ 78.25
RAINIER VIEW ROOTER $ 118.00
TOTAL FEES: $ 23,171.91
Applicant's Affidavit:
I certify that I have read and examined the information contained within the application and know the same
to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of
Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants,
easements and restrictions of record. If applying as a contractor, I further certify that I am currently
registered in the State AWashingW. — --�
Signature Date U 1,111
Firm 1 n ✓I t , �� Anll`�nGC,
OFFICIAL USE ONLY
# Sets of Prints:
Final Inspection:
Date:
By:
Cite of Yelm
(36) 458 -3244
RECD: 00271765 6/12/2017 4 -:26 PM
OPER: AS TERM: 001
REFS: 10030
PAID BY:
TRAN: 33.0000 BUILDING PERMITS
20170203 23,171.9'CR
SOUNDBUILT NW LLC
14526 98TH WAY SE
BLD -RES1 22,975.6ECR
MECH 78.Z CR
PL 118.0(CR
TRAN: 33.0000 BUILDING PERMITS
210170204 22,682.1 -CR
SOUNDBUILT NW LLC
9867 JENSEN RD SE
BLD -RES1 22,485.8ECR
MECH 78,Z CR
PL 118.0(CR
TRAN: 33.0000 BUILDING PERMIT'S
20170205 23,056.0`. CR
SOUNDBUILT NW LLC
14403 99TH AVE SE
BLD -RES1 22,846.3(CR
MECH 84.7`. CR
PL 125.0(CR
TRAN: 33.0000 BUILDING PERMIT'S
20170214 22,372.1'CR
SOUNDBUILT NW LLC
15435 92ND AVE SE
BLD -RES1 22,175.8ECR
MECH 78.2`. CR
F'L 118.0(CR
TRAN: 33.0000 BUILDING PERMIT'S
20170216 22,364.1ECR
SOUNDBUILT NW LLC
15411 92ND AVE SE
BLD -RES1 22,167.9'CR
MECH 78.2' CR
PL 118.0(CR
1E:NDERED: 113,646.34 CHECK.
APPLIED: 113,646.34 -
CHANGE : 0.00
CITY OF YELM
RESIDENTIAL BUILDING PERMIT APPLICATION FORM
Project Address: 14526 98th way SE
Subdivision: TahomaTerra
Parcel #: 78640101300
Lot #:13 Plan #:2603 -A Zoning:
0 New Construction ❑ Re -Model / Re -Roof / Addition a Home Occupation Sign
LEI Plumbing 0 Mechanical a Mobile / Manufactured Home Placement a Other
Project Description /Scope of Work: Construct new SFR using base plan 2603 -A elevation
Project Value:
Building Area (sq. ft) 1 st Floor 1262 2nd Floor 1336 3rd Floor Garage -2 car 414 3 car.
Covered Patio Covered Porch 50 Patio Deck
# Bedrooms 4 # Bathrooms 2_5 Heating GAS /OTHER r ELECTRIC (Circle One)
Are there any environmentally sensitive areas located on the parcel? No
If yes, a completed environmental checklist must accompany permit application.
BUILDING OWNER NAME: SoundbuiltHomes
ADDRESS PO Box 73790 EMAIL meganp @soundbuilthomes.com
CITY Puyallup STATE wA ZIP 98373 TELEPHONE 253 -848 -0820
ARCHITECT/ENGI NEER Landmark Design/Sega Engineers LICENSE # ENG -#26606 (Greg Thesencitz)
ADDRESS 1202 Main St #104 EMAIL kevin @landmarkdesign.com
CITY Sumner STATE wA ZIP 98390 TELEPHONE 253 - 826 -7808
GENERAL CONTRACTOR Soundbuilt Homes TELEPHONE 253 -848 -0820
ADDRESS PO Box 73790 EMAIL meganp @soundbuiRhomes.com
CITY Puyallup STATE wA ZIP 98373 FAX n/a
CONTRACTOR'S LICENSE # SOUNDHL831CL EXP DATE 2119 CITY LICENSE #
PLUMBING CONTRACTOR Rainier view Rooter LLC TELEPHONE 253-435-1996
ADDRESS PO Box 73070 —EMAIL
CITY Puyallup STATE wA ZIP 98373 FAX
CONTRACTOR'S LICENSE # PAINIVR942DF EXP DATE 3/18 CITY LICENSE #
MECHANICAL CONTRACTOR Sound Heating &AC TELEPHONE 253 - 875 -3350
ADDRESS 5526 184th St E #A —EMAIL
CITY Puyallup STATE wA ZIP 98375 FAX
CONTRACTOR'S LICENSE # SOUNDHC867DE EXP DATE 3/18 CITY LICENSE #
Copy of mitigation agreement with Yelm Community Schools, if applicable.
I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the
above described property will be in accordance with the laws, rules and regulations of the State of Washington and the
City of Yelm.
Megan Parsons
Ogtlally sign by Megan Parsons
Dale: 2017.05.1010:20:14 -0PO V
5/10/2017
Applicant's Signature Date
Owner / Contractor / Owner's Agent / Contractor's Agent (Please circle one.)
All permits are non - transferable and will expire if work authorized by such permit is not begun
within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days
105 Yelm Avenue West (360) 458 -3835
Yelm, WA 98597 (360) 458 -3144 FAX
www.ci.yelm.wa.us
ti
in
N
M
00
O
z
0
19' -112"
N01 °40'08"E 55.80' 35' -10"
\
\
\ \
TAHOMA
TERRA
5' BSBL
________________ _________________
\
2�
\
LOT -13
`�i:� SILT FENCE
Cn
N
\`\
\
\
\
APPROVED
,
J
m
\
\
By Randy at 9:37 am, Jun 06, 2017
S
X619'
/\
i. ■■ B■ B■. 9.■...■.■■■■■. ■... ■....... ■ ■ ■. ■...�• ■...9. ■.■ ■989.9.9.9 B9 B. B.
1?0�
\\
■ I
■ L9
\. A
•'
2' min. setback between sidewalks,
I
driveways, easements & STEP tanks
W /5' min. from property lines, house &
w
STEP--,,.,
TANK
porch foundations & 2' min. from utility
Q
a
n :I easements. LL /
Q
\ A
■ I \ v
Tank to be H2O traffic rated .
■ ' / 0 .
44' -6" �^ ; /�. G o / p�
■ d / ■.° a . a . v
D
CURTAIN ®l 1 l '
DRAIN WITH �1J F
��/ �'•
IPERFORATED 2603A - 2 SS C/O ; � /
■ PIPE (TYP) /
■ ■Im �
■ m
m
■ : R,
■ � ■ ! I I ��jN N
�9■ ■ 999. 99999999999999999 ■9999.9.9999999�� —� : `� •!� `//' d- n a'
t■■■■■■■■■�■■ . ..........� ANA
SIN
o
5' BSBL _
i— POWER
U) GAS v
6r 57— M
20' -1"
�'T
En ti
20'-l"
Aram[
SOUNDBUILT
HOMES, INC.
P.O. BOX 73790
PUYALLUP, WA 98373
PH: (253) 848-0820
FAX: (253) 539-0514
79.60' D
40' 19' 64"
ST C/O (TYP)
CITY OF YELM
THURSTON COUNTY
14526 98TH WAY SE,
Yelm WA 98597
PARCEL# 78640101300 - LOT 13
WG 05/16/2017
IMPERVIOUS AREA
ROOF= 1,950 S.F.
DRIVEWAY &
SIDEWALK =559 S.F.
TOTAL= 2,509 S.F.
LOT S.F. = 5,998
SCALE: 1"=10'
0 5 10 20
IN
I
" 1
JEIVSEN DR. SE
�L \
3:\
n
1. FRONT PORCH FOUNDATION AND STEP TANK
LOCATION SHALL BE STAKED OUT FOR SET BACK
INSPECTION.
CONTACT INFO
MEGAN: (253) 256 -8748
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Project Information Contact Information
2603
This project will use the requirements of the Prescriptive Path below and incorporate the
the minimum values listed. In addition, based on the size of the structure, the appropriate
number of additional credits are checked as chosen by the permit applicant.
Authorized Representative
All Climate Zones
Efficient Building Envelope 1a
R- Value a
U- Factor'
Fenestration U- Factor b
n/a
0.30
Skylight U- Factor
n/a
0.50
Glazed Fenestration SHGCb,,
n/a
n/a
Ceilingk
49'
0.026
Wood Frame Wall9,"',"
21 int
0.056
Mass Wall R- Value'
21/21h
0.056
Floor
309
0.029
Below Grade Wall""'
10/15/21 int + TB
0.042
Slab R -Value & Depth
10, 2 ft
n/a
*Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2.
Date
APPROVED by City of Yelm
John Rowland
06/05/2017 3:13:17 PM
Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to
achieve the following minimum number of credits:
1. Small Dwelling Unit: 1.5 credits
F Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of
fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but
less than 1500 square feet.
F,-]2. Medium Dwelling Unit: 3.5 credits
All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R -2 occupancies shall
require 2.5 credits.
[-]3. Large Dwelling Unit: 4.5 credits
Dwelling units exceeding 5000 square feet of conditioned floor area.
4. Additions less than 500 square feet: .5 credits
Table R406.2 Summary
Option Description
Credit(s)
1a
Efficient Building Envelope 1a
0.5
1 b
Efficient Building Envelope lb
1.0
1c
Efficient Building Envelope 1c
2.0
1d
Efficient Building Envelope 1d
0.5
2a
Air Leakage Control and Efficient Ventilation 2a
0.5
2b
Air Leakage Control and Efficient Ventilation 2b
1.0
2c
Air Leakage Control and Efficient Ventilation 2c
1.5
3a
High Efficiency HVAC 3a
1.0
3b
High Efficiency HVAC 3b
1.0
3c
High Efficiency HVAC 3c
1.5
3d
High Efficiency HVAC 3d
1.0
4
High Efficiency HVAC Distribution System
1.0
5a
Efficient Water Heating 5a
0.5
5b
Efficient Water Heating 5b
1.0
5c
Efficient Water Heating 5c
1.5
5d
Efficient Water Heating 5d
0.5
6
lRenewable Electric Energy
0.5
Total Credits
*Please refer to Table R406.2 for complete option descriptions
0
0.5
C
F
I
L_
.;
1.0
0.5
C
F--/j 1.5
n
*1200 kwh 0.0
3.50
Table R402.1.1 Footnotes
For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing.
a R- values are minimums. U- factors and SHGC are maximums. When insulation is installed in a cavity which is
less than the label or design thickness of the insulation, the compressed R -value of the insulation from
Appendix Table A101.4 shall not be less than the R -value specified in the table.
b The fenestration U- factor column excludes skylights. The SHGC column applies to all glazed fenestration.
"10/15/21. +TB" means R -10 continuous insulation on the exterior of the wall, or R -15 on the continuous
insulation on the interior of the wall, or R -21 cavity insulation plus a thermal break between the slab and the
basement wall at the interior of the basement wall. "10/15/21. +TB" shall be permitted to be met with R -13
cavity insulation on the interior of the basement wall plus R -5 continuous insulation on the interior or
exterior of the wall. "10/13" means R -10 continuous insulation on the interior or exterior of the home or R-
13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and
basement wall.
d R -10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1.
e There are no SHGC requirements in the Marine Zone.
f Reserved.
gReserved.
h Reserved.
The second R -value applies when more than half the insulation is on the interior of the mass wall.
'Reserved.
k For single rafter- or joist-vaulted ceilings, the insulation may be reduced to R -38.
Reserved.
m Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a
minimum of R -10 insulation.
Table R402.1.3 Footnote
a Nonfenestration U- factors shall be obtained from measurement, calculation or an approved source or as
specified in Section R402.1.3.
Window, Skylight and Door Schedule
Project Information
2603
Exempt Swinging Door (24 sq. ft. max.)
Exempt Glazed Fenestration (15 sq. ft. max.)
Vertical Fenestration (Windows and doors)
Component
Description
Ref. U- factor
0.20
Ref. U- factor
entry
0.28
entry
0.28
living
0.28
dining
MMEME
0.28
kitchen
0.28
nook
0.28
family
0.28
utility
0.28
bonus room
MMEME
0.28
bedroom 4
0.28
bedroom 4
0.28
bedroom 2
0.28
bedroom 3
10.28
master suite
MMEME
0.28
master suite
0.28
master bath
0.28
MMEME
house /garage
10.20
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
Contact Information
Width Height
Qt. Feet Inch Feet Inch
1 3 6 $
Width Height
Qt. Feet Inch Feet Inch
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
MMEME
Area UA
Area UA
Sum of Vertical Fenestration Area and UA
Vertical Fenestration Area Weighted U = UA /Area
Overhead Glazing (Skylights)
Component
Description Ref. U- factor
Width Height
Qt. Feet Inch Feet Inch
Sum of Overhead Glazing Area and UA
Overhead Glazing Area Weighted U = UA/Area
Total Sum of Fenestration Area and UA (for heating system sizing calculations)
341.8 94.28
0.28
Area UA
361.8 98.28
Simple Heating System Size: Washington State
This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and ACCA
Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling
loads.
Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section,
some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension
Program at (360) 956 -2042 for assistance.
Project Information Contact Information
2603
Heatinq System Type: *all Other Systems Deat Pump
To see detailed instructions for each section, place your cursor on the word 'Instructions ".
Design Temperature
Instructions Design Temperature Difference (AT)
V Lacey A AT= Indoor (70 degrees) -Outdoor Design Temp
Area of Building
17,048
Btu / Hour
Sum of UA XAT
Conditioned Floor Area
Air Leakage Heat Load
12,640
Btu/Hour
VolumeX 0.6XATX.018
Instructions Conditioned Floor Area (sq ft)
2,598
29,688
Btu / Hour
Average Ceiling Height
Conditioned Volume
32,657
Instructions Average Ceiling Height (ft)
Ducts in unconditioned space: Sum of Building Heat Loss X
8.5
22,083
Ducts in conditioned space: Sum of Building Heat Loss X 1
Glazing and Doors
U- Factor
X Area =
UA
Instructions
Building and Duct Heat Loss X 1.25 for Heat Pump
l U -0.28
J 0.280
362
101.36
Skylights
U- Factor
X Area =
UA
0.50
- --
Insulation
Attic
U- Factor
X Area =
UA
Instructions R_49
+ 0.026
1
1,336
34.74
Single Rafter or Joist Vaulted Ceilings
U- Factor
X Area
UA
Instructions
l I Select R -Value
]
i No selection
J
---
Above Grade Walls (see Figure 1)
U- Factor
X Area
UA
Instructions R -21 Intermediate
.
J 0.056
2,577
144.31
Floors
U- Factor
X Area
UA
Instructions R -38
+ 0.025
1,650
41.25
Below Grade Walls (see Figure 1)
U- Factor
X Area
UA
Instructions I Select R -value
.
No selection
Slab Below Grade (see Figure 1)
F- Factor
X Length
UA
Instructions
Select conditioning
.
No selection
---
Slab on Grade (see Figure 1)
F- Factor
X Length
UA
Instructions Select R -Value
No selection
- --
Location of Ducts
Instructions — —
Duct
Leakage Coefficient
Unconditione d S ace
1.10
Sum of UA
321.66
Figure 1.
Above Grade
53
Envelope Heat Load
17,048
Btu / Hour
Sum of UA XAT
Air Leakage Heat Load
12,640
Btu/Hour
VolumeX 0.6XATX.018
Building Design Heat Load
29,688
Btu / Hour
Air Leakage + Envelope Heat Loss
Building and Duct Heat Load
32,657
Btu / Hour
Ducts in unconditioned space: Sum of Building Heat Loss X
1.10
Ducts in conditioned space: Sum of Building Heat Loss X 1
Maximum Heat Equipment Output
45,720
Btu/Hour
Building and Duct Heat Loss X 1.40 for Forced Air Furnace
Building and Duct Heat Loss X 1.25 for Heat Pump
(07/01/13)