M-05-0641City of Yelm Community Development Department Building Division Phone: (360) 458-8407 Fax: (360)458-3144 Applicant: Name: Knight Fire Address: 9702 Lathrop Industrial Drive SW City: Olympia Property Information: Site Address: 1109 Yelm Avenue East Assessor Parcel No. 85810000100 Subdivision: Contractor Information: Name: Knight Fire Contact: Kemmer, Karen Address: 9702 Lathrop Industrial Drive SW City: Olympia Contractor License No: KNIGHFP044LK Expires: 05124107144 Project Information: Project: TCCU TI Description of Work: Sprinkler relocation for approx 340 sf. TI Phone: 786-8609 State: WA Zip 98512-9188 Lot: Phone: 786-8609 State: WA Zip: 98512-9188 Business License: 1659 Sq. Ft. per Floor: (1st) 340 (2nd) 0 (3rd) 0 Garage 0 Basement 0 Heat Type (Electric, Gas, Other): OTHER Fees: Item Item Fee Base Amt Unit Fee Unit Rate No. Units Unit Desc Building Permit-Other 74.89 0.00 0.00 0.0000 0.0000 $1,000 Building Plan Review 48.67 0.00 0.00 0.0000 0.0000 TOTAL FEES: $123.56 Applicants Affadavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applying as a contractor, I futher certify that I am currently registered in the Slate ~f Washington. ~ Signature Firm Date ,~~1~~~ Permit No: M-05-0641-YL Issue Date: 07/27/2006 (Work must be started within 180 days) Receipt No: 42880 # Sets of Pdnts: Final Ir Date: By: _ City of Yelm Community Development Department Building Division Phone: (360)458-8407 Fax: (360)458-3144 Permit Fees Schedule Permit No: M-05-0641-YL ARPlicattt Name: Knight Fire Phone: 786-8609 Address: 9702 Lathrop Industrial Drlve SW City: Olympia State: WA Zip 98512-9188 Project Information: Project: TCCU TI Description of Work: Sprinkler relocation for approx 340 sf. 71 Site Address: 1109 Yelm Avenue East Assessor Parcel No. 85810000100 Fees: Item Acct Code Item Fee Base Amt Unit Fee Unit Rate No. Units Unit Desc -- ------- ------ -------- ------ ------- Building Permit -Other ----- 032 001-322-10-00 -------- ----- 74.69 0.00 0.00 0.0000 0.0000 $1,000 Building Plan Review 100 001-345-83-00 46.67 0.00 0.00 0.0000 0.0000 TOTAL FEES: $123.56 .. - -. - -. ~_~upTHEp4/~ CITY OF YELM a Po. eox ass 4 ~~ 8 O ~ r~im_wA sees' RECEIPT No. snat 36C-a58-8403 i RECEIVED ****ONE HUNDRED TWENTY THREE DOLLARS & 56 CENTS i RECEIVED FROM DATE REG. NO. AMOl1NT REF NO KNIGHT FIRE PROTECTION INC 07/21/06 42880 123.56 CHECK 16817 9702 LATHROP INDUTRIAL DR SW ' OLYMPIA WA 98512 BUDGETARY ! M-05-0641-YL PERMIT 74.89 PLAN REVIEW 48.67 Re~~~v~d n ~i{ ~l~ r 1 `- `~ITYOFYELM JUL 7 2QQg Z u ` COMMERCIAL BUILDING PERMIT APPLICA N FORM Project Address: ~ Parcel #: Zoning; urrent Use: Proposed Use: ^ New Construction ~ Re-Model / Re-Roof /Tenant Improvement ^ Plumbing ^ Mechanical ^ Fire PrevendSuppress/Alarm ^ Other Project Project of Building Area (sq. ft) Parking Garage 1~` Building Height Floor 3`d Floor Are there any environmentally sensitive areas located on the parcel? _ completed environmental checklist must accompany permit application. If yes, a BUILDING O E NAME: / ADDRESS - E AIL CITY STATE IP TELEPHONE ARCHITECT/ENGINEER LICENSE # ADDRESS EMAIL CITY STATE ZIP TELEPHONE GENERAL CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # PLUMBING CONTRACTOR TELEPHO CITY LICENSE # EXP DA Copy of City Mitigation documentation (TFCI. I hereby certify that the above information is correct antl that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City ofAl'elm. , A pllcant's Signature Date Owner /Contractor /Owner's Agent /Contractor's Agent /Tenant (Please circle one.) All permits are non-transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days 105 Yelm Avenue West (360) 458-3835 PO Box 479 (360) 458-3144 FAX Ye[m, WA 98597 www.ci.yeim.w¢.us KNIGHT FIRE PROTECTION, INC. 9702 LATHROP INDUSTRIAL DRIVE SW OLYMPIA, WA 98512-9188 360-786-8606 FAX 360-786-8722 CONTRACTOR'S LICNNSE NO # KNIGIIFP044LK roN CUARD 24 HODRS A DAY" TO: WE ARE SENDING YOU. TRANSMITTAL DATE 10B NO A'I'IE N REFER ENI'F, THESE ARE TRANSMITTED AS MARKED BELOW For approval ^ For pour use [ I As requested REMARKS: f I For review and commcn[ COPY TO 1c1 / /S SIGNED /~ / ~)~ / l lll.....~~~ / l.( // fF E'.VCIASURES ARE NOT,4S DF,SCRIBED. P1~ASE NOTIFY OS AT ONCE. ~.`(/CQ Fire & Building Products Technical Services: Tel: (800) 381-9312 /Fax: (800) 791-5500 Series TY-FRB - 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response -standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1 /2 inch NPT) or Sryle 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the Flush pen- dent position. The adjustment prc- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING° that provides cautions with respect to handling and instal- lation ofsprinklersystemsand com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 oT 10 tained when exposed to corrosive at- mospheres. Although corrosion resis- tantcoated sprinklers have passed the standard corrosion tests of the appli- cableapproval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- siveenvironment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed inTechnical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- blestandards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance o/these de- vices. The owner is responsible /or maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. APRIL, 2006 ..; '~ a ..~, ~ . _ w t .., tl +`.. 't Model/Sprinkler Identification Numbers TY1131 - TY1231 - TY2131 - TY2231 - TY3131 - TY3231 - TY4131 - TY4231 - Upright 2.8K, 1/2"NPT Pendent 2.8K, 1/2"NPT Upright 4.2K, 7/2"NPT Pendent 4.2K, 1/2"NPT Upright 5.6K, 112"NPT Pendent 5.6K, 7/2"NPT Upright B.OK, 3/4"NPT Pendent B.OK, 314"NPT TFP771 Pag®2 of 10 TFP171 ESCUTCHEON PLATE SEATING SURFACE 2-1/4" (57,2 mm) 1 1-g/16" (39,7 mm) SSP DEFLECTOR'S 7/16" (11,1 mm) 1/2"** NOMINAL NPT MAKE-IN 2-7/S" (73,0 mm) DIA. sTrLE 10 or zo RECESSED SSU* ESCUTCHEON DEFLECTOR 6 7/16" 5 (11,1 mm) 4 NOMINAL MAKE-IN 2 2-3/16" 3 WRENCH (55,6 mm) FLATS 1 7 1/2"NPT** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 -Frame 3 -Sealing 4 -Bulb s -Deflector * Temperature rating is indicated on de68ctor Or adjacent to 2 -Button Assembly 5 -Compression 7 -Bushing orifice seal on frame. Screw **pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2-3/16' (55,6 mm) 1-1/2' (38,1 mm) 7/16" (11,1 mm) 1/2" ** NOMINAL NPT MAKE-IN WRENCH FLATS SSU* DEFLECTOR 7/16" (11,1 mm) NOMINAL MAKE-IN 2-3/16" (55,6 mm) 1l2" NPT »* 6* PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 -Frame 3 -Sealing 4 -Bulb 6 - Deflector * Temperature rating is indicated on deflector Or adjacent to 2 -Button Assembly 5 -Compression orifice seal on frame. Screw **pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/21NCH NPT snLE 10 or 20 RECESSED ESCUTCHEON SSP DEFLECTOR* I'~- 2-7/6" (73,0 mm) DIA. TKP177 Page 3 of 10 ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55,6 mm) 1 1-1/2' (38,1 mm) SSP DEFLECTOR" 7/16" (11,1 mm) 1/2" "• NOMINAL NPT MAKE-IN PENDENT STYLE 10 or 20 RECESSED ESCUTCHEON WRENCH FLATS 2-7/6" (73,0 mm) DIA. RECESSED PENDENT SSU" DEFLECTOR " 6 7/16" 5 (11,1 mm) NOMINAL 4 MAKE-IN 2-3/16' 2 (55,6 mm) 3 1 1 /2" NPT"' UPRIGHT CROSS SECTION 1 -Frame 3 -Sealing 4 -Bulb 6 -Deflector t Temperature rating is indicated on deflector or adjacent to 2 -Button Assembly 5 - Compression orifice seal on frame. Screw '* Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SER/ES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/21NCH NPT ESCUTCHEON 1/2" (12,7 mm) STYLE 30 or 40 PLATE SEATING •x NOMINAL RECESSED ~ SURFACE 3/4" MAKE-IN ESCUTCHEON SSU NPT ~ DEFLECTOR - 6e 2-5/16" i/2" 5 (12,7 mm) (58,7 mm) NOMINAL 4 MAKE-IN 1-9/16" 2-1/4" 2 (39,7 mm) WRENCH (57,2 mm) FLATS 3 1 SSP DEFLECTOR"' 2-7/6" (73,0 mm) DIA. ~ 3/4" NPT ~"` PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 -Frame 3 -Sealing 4 -Bulb 6 -Deflector 2 -Button Assembly 5 -Compression screw " Temperature rating is indicated on deflector or adjacent to orifice seat on frame. '"Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Page 4 of 10 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB NATURAL CHROME WHITE"' LIQUID BRASS PLATED POLYESTER 135°F/57°C Orange PENDENT 155°FI68°C Red (177231) 1 2 3 5 and 175°F/78°C Yellow , , , UPRIGHT fY1731 200°F/93°C Green 2 8 ) f ° ° . " F/141 C 286 Blue 1/2 NPT 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT (777231)` 175°F/79°C Yellow Figure 5 200°F/93°C Green 1, 2, 5 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red (771231)•' 775°F/79°C Yellow Figure 6 200°F/93°C Green 135°F/57°C Orange PENDENT 155°F/68°C Red (772231) and 175°F/79°C Yellow UPRIGHT 200°F/93°C Green 772131 4 2 ( ) ° ° . " 286 F/141 C Blue 1 2 1/2 NPT 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT (772237)` 175°F/79°C Yellow Figure 7 200°F/93°C Green 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red (772237)" 175°F/79°C Yellow Figure 8 200°F/93°C Green NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Ouick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-O1-E. 7. Where Polyester Coaled Sprinklers are noted to be UL and C-UL Listed, tha sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. ' Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. "Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. "` Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and 8 for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.6 GPM/psiln (40,3 LPM/bars/z) K = 4.2 GPM/psil/2 (60,5 LPM/bars/2) K = 5.6 GPM/psil/z (80,6 LPM/bar?/z~ K = 8.0 GPM/psi7/2 (115,2 LPM/bart/ ) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame . ...... . Bronze Button . . Brass/Copper Sealing Assembly . ........ . .. Beryllium .. Nickel w/Teflont Bulb ........ ...... Glass Compression Screw .. .. Bronze Deflector . .Copper/Bronze Bushing (K=2.8) .. ..... Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to Flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordancewith the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. E a a a~`~ N N C O a 0 } TFP171 Page 5 of 10 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS CHROME PLATED WHITE••• POLYESTER LEAD COATED PENDENT (TY3231) 135°F/57°C 155°F/68°C Orange Red and 175°F/79°C Yellow 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 UPRIGHT TY3131 200°F/93°C Green 5.6 1/2' ( ) 286°F/141°C Blue NPT 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red (TY3231)` 175°F/79°C Yellow 1, 2, 4, 5 N/A Figure 9 200°F/93°C Green 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red (TY3231)" 175°F/79°C Yellow 1, 2, 3, 4, 5 1, 2, 4, 5 N/A Figure 10 200°F/93°C Green 135°F/57°C Orange PENDENT (TY4231) 155°F/68°C Red and 175°F/79°C Yellow 1, 2, 3, 4, 5, 6, 7 1, 2, 5 UPRIGHT TY4131 200°F/93°C Green 6.0 3/4" ( ) 286°F/141°C Blue NP7 RECESSED PENDENT 135°F/57°C 155°F/68°C Green Orange (TV4231)• 175°F/79°C Red 1, 2, 4, 5 N/A Figure 11 200°F/93°C Yellow 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red (TY4231 )`• 775°F/79°C Yellow 1, 2, 3, 4, 5 N/A Figure 12 200°F/93°C Green NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Ouick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-426-3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094x/06) as Ouick Response Sprinklers. 8. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. ' Installed with Style 10 (1/2' NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. •' Installed with Styla 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. "' Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Nol Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page 6 of 10 TFP171 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED POLYESTER COATED PENDENT (TY3231) and 2.g UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2' RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and q 2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A 3/4' RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY323) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) 3/4" RECESSED PENDENT NPT (Ty4231) N/A NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Lisling by Underwriters Laboratodes, Inc. for use in Canada (C-UL); and ,the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) /or the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 fr.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 fr. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of f0 to 20 fr.lbs. (13,4 to 26,8 Nm). A maximum of 30 fr.lbs. (40, 7 Nm) of torque is tc be used to install sprinklers with 3/4 NPT con- necticns. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment ofthe sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP771 2-7/8"DIA. 5/611/4" (73,0 mm) 3/4"(19.1 mm) (15,938,4 mm) 2-1/4"DIA. i/4" (6,4 mm) FACE OF (57,2 mm) ~ MOUNTING SPRINKLER PLATE FITTING 1/8' (~ m) MOUNTING SURFACE CLOSURE SERIES 1-5/16' (33,3 mm) TV-FRB 13/16" (20,6 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2INCH NPT 2-7/9"DIA. 5/911/4' (73,0 mm) 3/4' (19,1 mm) (15.916,4 mm) 2-1/4' DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-1/4' 31,9 mm TV-FRB 3/4' (19,1 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2INCH NPT Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a /ire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used far hanging of any 2-7/8" DIA. (73,0 mm) 1/211/8" 1/2' 12,7 mm (12,713,2 mm) 2-1/4' DIA. 1/4' (fi,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8' (~ m) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 /NCH NPT Page 7 of 10 2-7/8" DIA. (73,0 mm) 1/211/8' 1/2" 12,7 mm) (12,713,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) ~ MOUNTING SPRINKLER pLg7E FITTING 1/9' (~ m) ~G SURFACE CLOSURE SERIES 1-1/4" 31,6 mm) TV-FRB 1' (25,4 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT W/TH TWO-PIECE 1/2INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2INCH NPT objects; otherwise, non-operation in the event ofa fire orinadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twisUslippage, or the like, must be re- placed. Also, replace any sprinkler thathasa cracked bulb orthathaslost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- spectingfrom the floor level, a random Page 8 of 10 2-7/6"DIA. 5/611/4' (73,0 mm) ~ 3/4'(19,1 mm (15,936,4 mm) 2-1/4'DIA. 1/4' (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/6' (3,21mm) J_ MOUNTING SURFACE CLOSURE SERIES 1-1/4' 31,6 mm TKFRB 3/4' (19,1 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/41NCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/21NCH NPT 2-7/6"DIA. 5/611/4" (73,0 mm) 3/4' 19,1 mm (15,966,4 mm) 2-1/4"DIA. 1/4' (6,4 mm) (57,2 mm) ~ MOUNTING FACE OF SPRINKLER PLATE FITTING 1/6' (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5116" 33,3 mm TY-FRB 13/16" (20,6 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, 2-7/6" DIA. 11211/6' (73,0 mm) ~ 1YY (12,7 mm (12,713,2 mm) 2-1/4' DIA. 1/4' (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/6' (~ m) ~G SURFACE CLOSURE SERIES 1-1/4' 31,8 mm TY-FRB 1" (25,4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/21NCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/21NCH NPT TFP171 2-7/6" DIA. 1/211/6" (73,0 mm) ~ 1/2" 12,7 mm) (12,713,2 mm) 2-1/4" DIA. 1/4' (6,4 mm) (57,2 mm) ~ MOUNTING FACE OF SPRINKLER PLATE FITTING 1/6' (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TKFRB 1-1/16"(27,0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/21NCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END'S' USED FOR 3/4" NPT MODELS) FIGURE 13 W-TYPE 6 SPRINKLER WRENCH tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. WRENCH RECESS 4 PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE 7 RECESSED SPRINKLER WRENCH -TFP171 P/N 57 -XXX - X -XXX L MODEUSIN 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2'NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 S.6K PENDENT (1/2"NPT) TY3231 390 B.OK UPRIGHT (3/4"NPT) TY4131 391 B.OK PENDENT (3/4"NPT) TY4231 ' Eastern Hemisphere sales only TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subjecttomisuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied orrepaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sale option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts.TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contrail, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in Contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tentpermitted bylaw. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Page 8 of 10 SPRINKLER RATING 135 135°F/57°C 1 NATURAL BRASS 155 155°F/68°C 4 WHITE POLYESTER 175 175°F/79°C 3 WHITE (RAL9010)" 200 200°F193°C 9 CHROME PLATED 2e6 266°F/141°C 7 I LEAD COATED Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (speciry temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (speciry') fin- ish, P/N (specify°). ' Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001.