Loading...
M-05-0639City of Yelm Community Development Department Building Division Phone: (360)458-8407 Fax: (360)458-3144 Applicant: Name: Viacom Address: 70 Banks Road I P.O. Box 2818 City: Stockbridge PropeRy Information: Site Address: 7109 Yelm Avenue East Assessor Parcel No. 85810000100 Subdivision: Contractor Information: Name: Viacom Contact: Address: City: Contractor License No: Expires: Project Information: Project: TCCU TI Description of Work: Approx 340 sf. TI Permit No: BLD-05-0639-YL Issue Date: 07/14/2006 (Work must be started within 180 days) Receipt No: 42760 Phone: 770-507-9973 x439 State: GA Zip 30287 Lot: Phone: State: Zip: Business License: Sq. Ft. per floor: (1st) 340 (2nd) 0 (3rd) 0 Garage 0 Basement 0 Heat Type (Electric, Gas, Other): OTHER Fees: Item Item Fee Base Amt Unit Fee Unit Rate No. Units Unit Oesc Building Permit-Other 293.25 0.00 0.00 0.0000 0.0000 $1,000 Building Plan Review 190.61 0.00 0.00 0.0000 0.0000 TOTAL FEES: $483.86 Applicant's Affadavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable Ciry of Yelm regulations incl ding those governing zoning and land subdivision, and in atltlition, all covenants, easements and re ions of record. t applying as a contractor, I futher certify that I am curr ntly registered in the Of~ashi Signature J'V~ ~- Date Firm # Sets of Prints: final Inspection: Dat~%~~~ By: L City of Yelm Community Development Department Building Division Phone: (360)458-8407 Fax: (380)458-3144 Applicant: Name: Viacom Address: 70 Banks Road I P.O. Box 2818 Project Information: Project: TCCU TI Description of Work: Approx 340 sf. TI Site Address: 1109 Yelm Avenue East Fees: Item Acct Code Building Permit-Other 032001-322-10-00 Building Plan Review 100 001-345-83-00 TOTAL FEES: City: Stockbridge Permit Fees Schedule Permit No: BLD-05-0639-YL Phone: 770-507.9973 x439 State: GA Zip 30281 Assessor Parcel No. 85810000100 Item Fee Base Amt Unit Fee Unit Rate No. Units Unit Desc -------- 293.25 ------- 0.00 --------- 0.00 -------- 0.0000 --------- --------- 0.0000 $1,000 190.61 0.00 0.00 0.0000 0.0000 $483.86 2 w r r- n~ ~ 6 z " w U Q tl! ~o U ro lL TT„ O A tr ~~ ~~ %~.~ Qm ~+.i z ~ T ~., ~ T U ~_ I ~ ~P ~e _I W ~i. W 's.%,ya 5~ U ~ z M E v a' W ~ U b ~b Vj 2 ^ ~ ~ N a = ~' a o ~ o ~ W ~ a ~ c ~ E ~ W m .?i E C7 H W O w a 0 z O x ~ N j lD O ~- rY1 W ,-~,' t W O ^ .y : c Dapw x > Q',N C7 ybCN ` ~ ~ W ~ M ~ O O ~^ar~ i ~. a F W O j m a G~i H -a i ~ ~ m m i ti i > w cK a a N M m N H ~ M W a Plan Review for Twin County Credit Union Safeway # 1619 Yelm, Washington June 12, 2006 1) Applicable Codes will be: a. 2003 Addition of International Building Code w/ Washington State Amendments b. 2003 NEC c. 2003 IFC d. 2003 IMC e. Washington State Energy Code f. ADA Chapter 11 of the IBC and ANSI 117.1 2003 ,,?~' Threshold to meet ADA requirements of/<" vertical or 'h" beveled change of level maximum. 3) The sales desk will have to be designed to accommodate the banking customers with needs. Design knee and toe clearance into the sales desk. ADA sign not required but would be nice on the area designated as accessible. Verify that the header for the security grill is adequate to carry the load. ,8J' Suspended Acoustic Ceiling to meet seismic requirements of Chapter 8 of the IBC 6) Show anchoring and lateral bracing of Composite Wall Panels a. Note Electrical Review and Inspection by the State of Washington. Electrical Inspection by Phil Ledford at 360-90 7) Sprinkler head locations subject to review. CITY OF YELM COMMERCIAL BUILDING PERMIT APPLICATION FORM ~ 9BS47 ~ ~ U Project Address: /~~i//Yj~dG. ~ ~Pa/jJ Parcel #: ~j ~`~/ (~> DDG ~ v Zoning; Current Use: Proposed Use: i ~ New Construction ~e-Model / Re-Roof /Tenant Improvement u Plumbing ~ Mechanical Fire PrevenUSuppress/Alarm -Other Project Description/Sdcope of 1 Project Value: ~J~ a~- Building Area (sq. ft) Parking Garage 1s` Flools~"„~Joor 3`° Floor Building Height (/~-~`- Are there any environmentally sensitive areas located on the parcel? _ completed environmental checklist must accompany permit application. AD Copy of Chy Mitigation tlocumentation (TFC). If yes, a I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the attyve tlescribetl property will be in ~tcordance with the laws, rules and regulations of the State of Washington and the Ci of Yelm. ~' ~ ~ ~yi.~ ~S re Date / Owner's Agent I Contractor's Agent /Tenant (Please circle one.) All permits are non-transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days 105 Yelm Auenue West (360) 458-3835 PO Box -179 (360) 458-3144 FAX Yelm, WA 98597 www.ci.yelm.m¢.¢a PLUMBING CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE CITY LICENSE # !~ VIACON, INC. 70 BANKS ROAD • STOCKBRIDGE, GA 30281 (770) 507-9913 • FAX (770) 507-9536 (Mailing Address: P.O. Box 2818 • Stockbridge, GA 30281-8930) The Pre- Fabricated plywood wall panels to be used in the following Yelm, Washington- Twin County Credit Union Branch in Safeway are installed as follows: Wall panels are attached to each other by screwing the left vertical end rib of one panel to the right vertical end rib of the next panel using 2" #8 drywall screws at approximately 16" O.C. a. Wall panel Type 1- "One sided panels"- Wall panels that go against existing walls have no skin on the side facing the existing wall, so the vertical interior ribs are accessed from the open side. The panels are connected together before the wall is put into place. b. Wall panel Type 2- "two sided panels"- Wall panels with two exposed sides (two skins) are connected together after the wall is put in place. The skin on one side of every other panel is left off until the connecting screws are in place. Those skins are installed after the panel- to- panel connections are made. 2. Wall panels are attached to the existing floor via'/<"x2-3/4" tap-on cons through the base plate of the panel at approx. 4'-0" O.C. and on each side of every doorjamb. Openings in the wall skins for installation of tap- cons are concealed by base molding. ~`~'~ <7F YELM ~o,c,r, +~LER~{ - ~'RE~SUR~R'S O~FlCE. N~ 5i ,,'~,un i_;P1T11 F FC I:i °~ID VTACON; TNC PO Bi~i 2Fj_F ST(~CKRRTT~It;R GA 9~JR1 AT 7. t~iiT ~iF TiiWiQ ~ ~~ < ~ ~-..ce r ~~si b~: ~ t _ _ ,. „_ , ._t tl ~. ~~~..~ ~s Icccrtio^ - • • -'' _ - -L11F _LP ~ 3u~~_-. _._ L,;r~~ ~5-f~Cn3G~ i 3. ~ LICENSc IVUh4B67 Ol5-v~m3ml3. ~ PAID G~O~"~0~1"~.@jG~S/19/~6I,CONTRACTOR; 01.1T OF TOWN ~ 35.r~m 1iTyi OTQ; TNC: C/O \tTA; Ri_1SSFTT, N an ac-,x 2~~ n STOCKR_RTD~E r;A CITV ORDINANCE X342 STATES LICENSES MUST BE RENEWED BV THE 1ST OF FEERUARV EACH YEAR. ~~~e~ iO INSURE PROPER RENEWAL OF YOUR LICENSE RETURN THIS PORTION C/0 C T CORPORATION SYSTEM 520 PIKE ST SEATTLE WA 98101 000358 oErncii aEFOaE Posru,-.-; a s uyH nY~£ .~,~ STATE OF WASHINGTON MASTER LICENSE SERVICE PO Box 9034.Olympia, WA 98507-9034 • (360) 664-1400 REGISTRATIONS AND LICENSES Unified Business ID #: 602 121 752 Business ID #: 1 VIACON, INC. 520 PIKE ST SEATTLE WA 98101 Foreign Profit Corporation Renewed by Authority of Secretary of State The licensee nemetl above has been Issued the business registrations or licenses listetl.6y accepting this document the licensee certifies the information provided on the application for these licenses was complete, true, and accurate to the best of his or her knowledge, and that business will be conducted Ih compliance with all applicable Washington state, county, and city regulations. a Expires: 05-31-2007 Director, Department of Licensing Look Up a Contractor, Electrician or Plumber License Detail Page I of 3 I'll Topic Index ~ Contact Info Search. Home Safety Claims 8: Insurance Workplace Rights Trades & Licensing Find a Law or Rule Get a Form or Publication Look Up a Contractor, Electrician or Plumber Printer Friendly Version General/Specialty Contractor A business registered as a construction contractor with Llil to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License VIACOI'990LK Licensee Name VIACON INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602121752 Verify Workers Com~remium Statics Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 2818 70 BANKS RD Address 2 City STOCKBRIDGE County OUT OF STATE State GA Zip 30281 Phone 7705079913 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 6/21/2001 Expiration Date 4/27/2007 Suspend Date Separation Date Parent Company Previous License Next License Associated License https://fomess.wa.>;ov/lni/bbip/Detail.asnx?License=VIACOI*990LK 7/13/2006 Look Up a Contractor, Electrician or Plumber License Detail Business Owner Information Name Role Effective Date Expiration Date CLEMENS, PATRICIA A PRESIDENT 06/12/2001 VIA, RUSSELL N SECRETARY 06/12/2001 VIA, RUSSELL N TREASURER 06/12/2001 VIA, RUSSELL N VICE PRESIDENT 06/12/2001 Bond Information Page 2 of 3 Bond Bond Company Account Effective Expiration Cancel Impaired Bond Received Bond Name Number Date Date Date Date Amount Date PLATTE RIVER Until #3 INS CO 41063532 04!0412006 Cancelled $12,000.00 03/23/2006 HARTFORD Until #2 FIRE INS CO 20BSBAN1492 04/04/2003 Cancelled 04/04/2006 $12,000.00 04/04/2003 WESTCHESTER Until #1 FIRE INS CO K06464142 05/01/2001 Cancelled 05/10/2003 $6,000.00 06/25/2001. Savings Information No Matching Information Insurance Information Effective Expiration Cancel Impaired Recei Insurance Company Name Policy Number Date Date Date Date Amount Dat HARTFORD CAS INS #7 CO 2000QTW8723 04/15!2006 04/15!2007 $1,000,000.00 04/141 HARTFORD CAS INS #b CO 2000QTW8723 04/15/2005 04/15/2006 $1,000,000.00 07/18/ VALLEY FORGE INS #5 CO TCP2058147613 08/02/2004 08/02/2005 $1,000,000.00 08/09/ #4 VALLEY FORGE TCP2058147613 08/02/2003 08/02/2004 $1,000,000.00 08/04/ #3 CNAINS CO TCP2058147b13 08/02/2002 08/02/2003 $1,000,000.00 04/08/ TRANSCONTINENTAL #2 INS CO TCP2057047285 05/08/2002 05/08/2003 05/30/ NW NATIONAL #1 CASUALTY ECA9031517 06/01/2001 06/01/2002 06!12/ Summons 1 Complaints Information No Matching Information Start a New Search. Printer Friendly Version About LQI ~ Find a job at L&i ~ Information en espanol ~ Site Feedback ~ 1-800-547-8367 https://fortress.wa.gov/lni/bbip/Detail.aspx?License=VIACOI*990LK 7/13/2006 Look Up a Contractor, Electrician or Plumber License Detail Page 3 of 3 ~~) Washington Stale Dept. of Labor and Industries. Use of this site is subject to the laws of the state of Washington. ~ Access Agreement ~ Privacy and security statement ~ Intended use/external content policy ~ Staff only link V75iC ACCESS. W a, gOV https://fortress.wa.gov/lni/bbip/DetaiLaspx?License=VIACOI*990LK 7/13/2006 07!18/2006 17:29 13608679318 5~/~1RCENT 320 Ronlee Lane NW oympia, wssnhgron sesoz•sza~ Tel 360 667-9264 Fex 360 667-9316 www.sargenlengineers.can Received JUL 1 9 2006 July 18, 2006 Mr. Bill Schmidtke Capital Sheet Metal 1218 Carpenter Road SE P. O. Box 3387 Lacey, WA 98503 RE: Yelm Safeway Heat Pump Project No.: A06177.00 Dear Mr. Schrnidtke: You aze installing a new heat pump on the roof of the Safeway located in Yelm. The heat pump will weigh 357 pounds and will be mounted on top of a glued laminated beam that is at the front of the store. It will be installed in the first cleaz bay between the joists which is approximately eight feet from the end of the beam. The supply and return for the heat pump will be brought through the roof on one side of the glued laminated beam. Our scope of work includes: Check the glued laminated beam to see if it is able to support the additional weight from the heat pump. Make recommendation for the installation of the unit. The joists and other roof framing are not being checked since the cen[er of gravity of the heat pump will be located over the glued laminated beam. The addition of the heat pump will only increase the stresses in the glued laminated beam by at most two percent. The total stresses aze well below the allowable for the beam. The calculations for the check of the beam are attached. The heat pump should have a curb installed below the heat pump. The curb should be able to distribute the weight of the heat pump to the glued laminated beam and span between the joists. At the edge of the opening for the supply and return, I recommend that you install at 2x4 between the wood joists and attach the 2x4 with a Simpson LUS24. The web of the joist will have to be installed with a web stiffener (material matching the web of the joist to build out the thickness to the full width of the beam). This will have to be glued to the joist. SARGENT ENGINEERS PAGE 01 07/18/2006 17:29 13608679318 SARGENT ENGINEERS PAGE 02 r~Ill~r \V~~ Mr. Bill Schmidtke Page 2 July 18, 2006 If you have any other questions regarding this installation, please call. Sincerely, Sargent Engineers, Inc. ~j~ Monte Smith Principal MJS \\Serverl\F§Ics\06FileaW06177.00 SakwayHVACUnit\Itccommend.doc 07/18/2006 17:29 13606679318 SARGENT ENGINEERS ~~~~~ Project: Safeway HVAC Design by: MJS Check by: Subject: Loads Date: 7/18/2006 Page: 1 Loads applied to the beam. Place the unit on the glued laminated beam. Approximately 8 feet from the end. PAGE 03 Contributory span length of the roof is 40 feet on one side of beam and 12 feet on the other side of the b Beam size is 5 1/8 x 32 Joists aze spaced at four feet on center. Roofing is single ply roofmg with insulation under the roofing. Current code is 2003 IBC. Dead load lb 5•- wd1:=0.7.12+2.12+3.212+ 4-~ +1.12 ft ft ft ft µ'dl = 8.15 12 ft Live Load K'll ._ 25 lb ftz Uniform loads on beam 40•ft+12ft Wd] ~= 2 'µ'dl ~'d1=211.9E 40•ft+ 12•ft Wll ~ 2 'e'll Roofing + insulation + plywood + joists + ceiling load Snow load I'll = 650 ft 07/18/2006 17:29 13606679318 ~~ [ ~-~7 SARGENT ENGINEERS Project: Safeway HVAC Design by: MJS Check by: Subject: Loads Date: 7/18/2006 Page: 2 The load for the new mechanical equipment is 357 pounds. PAGE 04 Based on the following Enercalc output, the beam will be just fine. The bending stress only increases b' percent and the sheaz stress increases by 2 percent. Well within the stress limits of the beam. 07/18/2006 17:29 13606679318 5~1RGE11rT SARGENT ENGINEERS Title: Seleway HVAC Additlon Dagnr: MJS Deserlption Scope: PAGE 05 Job # A06177.00 Date: 4:33PM, 18 JUL O6 nee: seoooa use~.xwcminav, ve~s.e.o. i-~=~zcos _ General Timber Beam ., Page 1 Description Main GluLam General Information Cade Ret: 1997/2001 NDS, 2000/20031BC, 2003 NFPA 5000. Base allowables are user donned Section Name 5.125x31.5 Center Span 34.00 ft .....Lu 4.D0 h Beam Width 5.125 in Len Cantilever tt .....Lu 0.00 n Beam Depth 31.500 In Right Cantilever n .....Lu O.DO n Member Type OluLam Douglas Fir, 24F - V4 Fb Bose Allow 2,400.0 psf Load Dur. Factor 1.150 Fv Allow 240.0 psI Beam End Flxity Pin-Pin Fc Allow 650.0 psi E 1,800.0 ksi Full Len th UnHorm Loads Center OL 212.00 #/n LL 650.00 #/n Left Cantllever DL #/n LL #/n Right Cantilever DL #/n LL #/n Beam Dealgn OK Span= 34.OOn, Beam Width = 5.1251n x Depth = 31.SIn, Ends are Pin-Pin Max Stress Ratio 0.751 ; t Maximum Moment 124.6 k-ft Maximum Shear' 1.5 t6.s k Allowable 1es.s k-n Allowable aa.s k Mex. Positive Moment 124.58 k-ft at 17.000 ft Shear. ®Len 14.65 k Mex. NegaWe Moment 0.00 k-n at 34.000 n ®Right 14.65 k Mex ®Lett Support 0.00 k-tt Comber: ®Len O.000In Max 61 Right Support 0.00 k-n ® Center 0.3961n ®Right O.000In Mex. M albw 165.85 Reactions... fb 1,763.57 psi 1v 115.48 psi Len DL 3.60 k Max 14.BSk Fb 2,348.22 psi Fv 276.00 psi R{ght DL 3.60 k Max 14.65 k Deflections Deflectlon •0.2851n -1.079 In Deflection 0.000 In 0.000 In ,,.Location 17.000 ft 17.000 n ...Length/Defl 0.0 0.0 ...Length/Defl 1,538.0 378.25 Right Cannlever... Camber (using 1.5' D.L De11) ... Deflectlon 0.000 In 0.000 in ® Center 0.3981n ...Length/Defl 0.0 0.0 ® Len D.000 In Right 0.000 In Stress Calcs Bending Analysis Ck 20.711 Le 8.237 n Sxx 647.547 in3 Area 161.436 in2 Cv 0.665 Rb 10.690 G 0.963 Max Moment x Re 'd Allowable fb ®Center 124.56 k-n 636.53 in3 2,348.22 psi t$ Lek Suppon 0.00 k-tt 0.00 in3 2,368.20 psi ® Right Suppon 0.00 k-n 0.00 in3 2,388.20 psi Sheer Analysts ~ Len Support ®Rlgh[ Support Design Shear 18.64 k 18.64 k Area Required 67.536 in2 67.536 in2 Fv: Allowable 276.00 psi 276.00 psi Bearing ®Supports Max. Lan Reaction 14.65 k Bearing Length Req'd 4.399 in Max. Right Reaction 14.65 k Beadng Length Req'd 4.399 in 07/18/2006 17:29 13608679318 5,1o11'tGEIVT SARGENT ENGINEERS TRIe : Safeway HVAC Addition Dsgnr: MJS Descrlptlon Scope: PAGE 05 Job 8 A06177.00 Date: 4:33PM, 16 JUL O6 I/ser. KW-060146V. ver 5.8.0. I-0ec 2009 g 1iBV General Timber Beam Pa e 2 r Description M, V, 8 D ®Specltled Locatkms Moment Shear Deflection ® Center Spen location = 0.00 tt 0.00 k-tt 14.65 k 0.0000 in ®Right Cent. Locatlon = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in ~ Left Cent. Location= 0.00 k 0.00 k-k 0.00 k 0.0000 in Sketch & Diagram tt4.be _. - - na n ~,-~fl rI 1 TTT7TT71 f~-rrr~ T7 ~7~1 ~ Tl ~ ~ ~~ r ^n~m a w 7VyVlflll 111 fIf Iff1 11 rf/1f r /i)i1x1~1 I/ ) -,)a]o bz2e -- s1 ez 6).n ~ ~ 31A1 1].46 idb~° I~'~'~ uo Bondi y MO B ~IttB .~ 1 .10 .62 .B3 .36 2 .)e ] .Tr .m 31.1 Onax..1,0)9h Locatbn ffl1 Rmax•14Jx Vm¢, O IM.11.)k awk • 14.E vmm a rl • 14.)k "L' +~ c x Beam hear n21 _ O A - _ . ).]0 4.88 2A1 0.0 a.bz .._ _. -- t.r ib.eb 4 61 . 26 .~ .D 1 .62 m 2 .36 .la 2 .A 3 .SG 31! Uetlec ion Locbtlan fnl Lxellon fal b.n -- - r.za ox o.ee -- o.eo - - _-- o.n ~.B/ o.Aa --- _. _ ___.__ - __ 28 .tN 1 .b .62 1 .G3 .33 .70 2 .1l .30 1 07/18/2006 17:29 13608679318 - ~/~1RRGENT SARGENT ENGINEERS Tkle :Safeway HVAC Addition Dsgnr: MJS DesoripNOn Scope: PAGE 07 Job M A06177.00 Date: 4:32PM, 18 JUL 06 ...... ,M,w. User KW-OSDIE69. Ver S.e 0. 1-Dec-2IX73 General Timber Beam age Description Main GluLam General Information ~ Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. 8ese allowables are user defined r_ or rrr-~ Section Name 5.125x31.5 Center Span 34.00 k ... .Lu 4.00 ft Beam Width 5.125 in Left Cantllever tt .....LU 0.00 tt Beam Depth 31.5001n Rlghl Cantllever tt .....Lu 0.00 k Member Type CIIuLem Douglas Flr, 24F - V4 Fb Base Allow 2,400.0 psi Load Dur. Factor 1.15D Fv Allow 240.0 psi Beam End Fixity Pin-Pin Fc Allow 650.0 psi E 1,800.0 ksi ~ Full Length Uniform Loads _ J Center DL 212.00 #/k LL 650.0 #/k Left Cantlever DL #/fl LL #/k Right Cantllever DL #/k LL #/k Point Loads Live Load Ibs ...distance 8.000 k Ibs Ibs Ibs 0.000 ft 0.000 tt 0.000 tt Ibs Ibs Ibs 0.000 k 0.000 ft 0.000 ft Beam Design OK Span= 34.OOk, Beam Width = 5.1251n x Depth = 31.Sin, Ends are PIn-Pin Max Stress Ratio D.7so : 1 Maximum Moment 12s.o k-n Maximum Shear ` 1.5 1s.o k Allowable 165.9 k-tt Allowable ~.6 k Max. Posltlve Moment 125.99 k-ft et 16.864 k Shear: ®Lett 14.93 k Max. Negative Moment 0.00 k-k at 34.000 k ®Right 14.74 k Max fd Lek Support 0.00 k-tt Camber. ®Lek 0.000In Max ®Right Support 0.00 k-ft ®Center 0.419 in Max. M allow 165.&5 Reactions... ®Right O.000In fb 1,783.84 psi fv 118.00 psi Lett DL 3.66 k Max 14.93 k Fb 2,348.22 psi Fv 276.00 psi Rlghl DL 3.69 k Max 14.74 k Deflections ...Location 16.854 tt ... LengtWDef I 1,462.2 Camber (using 1.5 • D.L. De11) ... ~ Center 0.419In ® Left 0.000 in ®Right 0.000In -1.0921n Deilectlon 17.000 tt ...Length/Defl 373.49 Right Cantllever... Dekectlon ...Length/Defl 0,000 In 0.000 in 0.0 0.0 0.000 in 0.000 In 0.0 0.0 07/18/2006 17:29 13608679318 SARGENT ENGINEERS PAGE 08 SRIRGENT Title : Safeway HVAC Addition Dagnr: MJS Daecrlptlon $COpe: Job p A06177.00 Date: 4:32PM, 16 JUL 06 u~°"`"-°°°'°°9. va, s.e.o. f-o~-zoos General Timber Beam _,_. _ . Page., 2 (c)19I132(xIJ EE&RCAtC Endnawnm s„xw,.o Description Main Glu Stress Calcs Bending Analysts Ck 20.711 Le 8.237 tt Sxx 847.547 in3 Area 161.438 In2 Cv 0.665 Rb 10.890 CI 0.983 Max Moment $xx Re0'd Allowable fb ® Center 125.99 k-tt 643.&1 in3 2,346.22 psi ® Lek Support 0.00 k-ft 0.00 in3 2,388.20 psi ® RlghtSupport 0.00 k-h 0.00 Ina 2,388.20 psi Shear Anarysls ®Lefl Support ®Right Suppon Design Shear 19.05 k 18.77 k Area Required 69.019 in2 67.992 in2 Fv: Allowable 276.00 psi 276.00 psi Bearing Q Supports Mex. Lett Reaction 14.93 k Beadng Length Req'd 4.481 in Mex. Right Reacllon 14.74 k Beadng Length Req'd 4.424 in Query Values M, V,& D ~ SpaeMled Loeetbna Moment Shear De}kiedon ® Center Span Location = 0.00 tt 0.00 k-N 14.93 k 0.0000 (n ®RigM Cant. Location = 0.00 tt 0.00 k-ft 0.00 k 0.0000 In ®Lefl Cant. LocaBOn = 0.00 ft 0.00 k•ft 0.00 k 0.0000 In Sketch & Diagram ~ r 11 1 i t ~ 1 eea4m 9YIf~-IM.Ok~n o~„m..l.onr, RT.o~•14.9Y vmmekrt. i4.w Frt~w • luk vmaxon-14.n Locann rnl t~ Beam hear LRCatbn (at i3.N R.or r.ne <.ar ~s9 90 a.ee ~r.al nar 4.ea .R .fm Id s2 _ .R3 3! 2 .m z ..n m ~, Lxatbn fn)