402 West Rd (3)
City of Yelm
Site Plan Review Committee
105 Yelm Avenue West
Yelm, WA 98597
Pre-Application Meeting
These comments are preliminary in nature and are not intended to represent final comments and or
requirements for the City of Yelm. Until a complete application is made, the Community Development
Department can only attempt to inform the applicant of general requirements as they appear in the
form presented by the applicant at the time of pre-submission.
Proponent:
Project Proposal: Convert building to commercial lease space and or restaurant
Project Location: 402 West Road NE
Parcel Number: 64303601500
Property Background and Characteristics
The property is located on the NE side of West Road, directly across from 4th Street. The
property is approximately .5 acres, with an existing building commonly known as Tom, Dick &
Harry’s Meat Market. The building has been vacant for several years.
Proposal
The proposal is to remodel the building into commercial lease space/restaurant.
Critical Areas
The City critical area maps indicate that the property is located outside of wetlands, flood
zones, and high ground water areas.
All of Yelm is considered a critical aquifer recharge area. Protection measures for development
within a critical aquifer recharge area are met through treating and disposing of stormwater
through an approved stormwater system.
Fish and Wildlife Habitat Conservation Areas
The Critical Areas Code maps indicate the property contains soils moderately suitable as habitat
for the Mazama Pocket Gopher, a protected species listed on the Washington Priority Species
and Habitat List as well as the Federal Threatened Species List. If members of the species are
found on the property, a critical areas report is required.
Pre-Application Meeting
Page 2 of 8
Compliance with Yelm’s requirements under the Critical Areas Code does not ensure
compliance with the provisions of the Endangered Species Act. The applicant should contact
Tim Romanski of the US Fish and Wildlife Service at 360.753.5823 or tim.romanski@fws.gov
with any questions about compliance with Federal standards for threatened species.
Development Standards
Zoning
The property is zoned Commercial (C-1) which is codified at Chapter 18.36 YMC. The purpose
of the C-1 zone is to provide for the location of business centers to serve the needs of the
community for goods and services.
The C-1 zone allows service oriented businesses as a permitted use as part of the site plan
review process. The minimum size of any parcel to be developed in the C-1 district is 5,000
square feet. Setbacks are 10 feet from side property lines, 20 feet from the rear property line,
and 15 feet from the front property line.
The maximum height of buildings is 40 feet.
Water
The proposed project is located in the City of Yelm’s water service area and is currently
connected to the City of Yelm’s water system. Water connections are based on the use of 875
cubic feet of water usage per month. An engineer’s calculation of proposed water usage or
proof of water usage by similar business will be required. It is anticipated that a restaurant will
require additional water connections.
All commercial buildings and irrigation systems are required to provide for cross-connection
control through the provisions of a back flow prevention device (reduced pressure backflow
assembly) installed on the water services. A list of approved devices can be found at Chapter
246-290-490 WAC. The backflow device is required to be installed after the meter and tested
by a certified backflow tester. If a separate irrigation meter is installed, an approved backflow
prevention device shall be provided. There is an existing RPBA onsite; however the location
appears to be in conflicted with needed parking and access. It is anticipated that the RPBA will
need to be relocated.
The Unified Development Code, Title 18 YMC, requires the Community Development
Department to make a written finding of concurrency for any approval for a land division or site
plan (including any development activity). For water, the finding must include the fact that
“improvements necessary to provide city standard facilities and services are present or are in
Pre-Application Meeting
Page 3 of 8
an approved and funding plan to assure availability in a time to meet the needs of the proposed
development.”
The State Subdivision Act, Chapter 58.17 RCW, requires that the City of Yelm make a written
determination that appropriate provisions are made for potable water supplies as part of the
preliminary land division process.
The State Building Code at Section 19.27.097 RCW requires evidence of water availability and
the issuance of a building permit by the City of Yelm is the City’s commitment to serve a
proposal with potable water. If the City does not have sufficient approved water connections
at the time a building permit for the proposed development is ready to issue, the permit will be
denied until additional water resources are available.
The City currently has sufficient water connections to serve some anticipated growth.
Sewer
The site is within the City of Yelm sewer service area, however is not connected to City sewer.
There is a 3 inch sewer main located in Stevens Street. Connection to City sewer service is
required. Sewer connections are based on 875 cubic feet of water usage per month. There is a
service stub located near the property. The exact location will need to be located. It is
anticipated that connection can be made at the service stub and extended to the site.
S.T.E.P. tank sizing is governed by the Criteria for Sewage Works Design (Orange Book)
published by the Washington State Department of Ecology. The tank needs to be located in the
front of the building. Traffic bearing tanks are an option.
A properly sized oil/water separator is required if there is any potential for oil to enter the
sanitary sewer system. A properly sized grease interceptor will be required if there is any
potential for the introduction of fats, oils, or greases to enter the sanitary sewer system. This is
required for a restaurant
Stormwater
The City of Yelm has adopted the 2012 Stormwater Management Manual for Western
Washington published by the Washington Department of Ecology. Stormwater from new
impervious surfaces is required to be treated and released. Roof runoff shall be distributed to
individual dry wells. (this includes parking, drive aisles and frontage improvements.
Pre-Application Meeting
Page 4 of 8
Transportation
The City of Yelm Development Guidelines and the concurrency requirements of Chapter 18.16
YMC require all new developments to improve street frontages to current City standards. The
proposed development will trigger additional frontage improvements on West Road. West
Road is considered a Commercial Collector with an 11 foot drive lane, a 5 foot shoulder, 7 foot
planter strip and 5 foot sidewalk. It is anticipated that the shoulder, planter strip and sidewalk
will be required. Right of way dedication will be determined as part of frontage improvements.
Yelm Development Guidelines allow two commercial driveways. The location of the current
driveways is adequate.
Parking
The Unified Development Code at Chapter 18.54 YMC provides minimum parking requirements.
Restaurants require one stall for each 200 square feet of floor space, retail requires one stall for
every 250 square feet, and office requires one stall for every 300 square feet. It is the owner’s
responsibility to provide adequate amounts and arrangement of space.
Parking spaces in banks of 90 degrees are 9 feet in width by 20 feet in length and require a 23
foot drive aisle. In parking facilities containing 25 or more parking spaces, a maximum of 25
percent may be compact stalls. All parking is required to surfaced with asphalt or cement.
Parking areas are required to be landscaped to provide visual relief and shade. At least 24
square feet of landscaping is required for each parking stall proposed. Each area of landscaping
must contain at least 100 square feet of area and must be at least six feet in any direction. Each
planting area must contain at least one tree, and no parking stall shall be located more than 50
feet from a tree. Live groundcover shall be provided throughout each landscaping area.
Building and Design Guidelines
Design Standards
Service areas, outdoor storage areas and other intrusive site features must be located at the
rear of the lot to reduce conflicts with adjacent uses. All trash enclosures must incorporate the
architectural features of the primary structures and landscaping to minimize visual impacts of
the Enclosure. Trash enclosures will be reviewed by Pacific Disposal to ensure adequate service
can be provided.
Perimeter landscaping is required and is characterized by an 8 foot landscape strip along
property lines of any combination of evergreen and deciduous trees (with no more than 50
Pre-Application Meeting
Page 5 of 8
percent being deciduous), and shrubs. The intent is to provide partial screening and buffering
between uses and of softening the appearance of streets, parking and structures.
A dense sight barrier landscaping is required between the site and the residential uses to the
east and west. A dense sight barrier is required to be 15 feet wide and include a combination
of trees, shrubs, walls, earthen berms and related plant materials so that the resultant effect is
sight-obscuring.
Parking lots must be lit to the standards of the design guidelines and include non glare, shielded
fixtures no higher than 30 feet above grade. A lighting plan is required as part of civil
construction plan review.
Pedestrian circulation paths within the property require paved walkways from sidewalks to the
building, should tie into neighboring properties when feasible, and provide pathways through
parking lots. Within parking lots, the path material must be different than asphalt.
Permit Process
State Environmental Policy Act
The project is exempt from environmental review pursuant to Section 197-11-800(3).
Critical Areas Report
If a critical areas report is required, it must be prepared by a qualified professional using
scientifically valid method and studies in the analysis of critical area data and field
reconnaissance, and reference the source of science used. The report must evaluate the
proposal and all probable impacts to critical areas in accordance with Chapter 18.21 YMC.
Minimum report requirements may be found in Chapter 18.11 YMC.
Compliance with Yelm’s requirements under the Critical Areas Code does not ensure
compliance with the provisions of the Endangered Species Act. The applicant should contact
Tim Romanski of the US Fish and Wildlife Service at 360.753.5823 or tim.romanski@fws.gov
with any questions about compliance with Federal standards for threatened species
Land Use Review Process
The Ministerial Site Plan Review process is an administrative approval designed to ensure
compliance with development regulations. The process is codified at Chapter 18.10 YMC.
A site plan review approval typically contains conditions of approval that the applicant must
complete prior to receiving a building permit. A site plan review approval is good for 18
Pre-Application Meeting
Page 6 of 8
months. Upon satisfactory completion of all conditions of land use approval, the applicant can
submit building plans for approval.
Civil Plan Review
Civil Plan review generally takes place after a land use approval. The Yelm Development
Guidelines contain standard details for all infrastructure requirements, including parking lot
layout, sewer and water lines, S.T.E.P. tank design, and stormwater control.
The City uses a third party engineer for peer review of civil plans. Depending on the number of
revisions, the process can take 2 to 4 weeks for each revision.
Building Permit Process
The City of Yelm has adopted the International Codes as amended by the State Building Code
Council for Building, Fire, Mechanical, Fuel Gas, Existing Building and the Uniform Plumbing
Code and the Washington State Energy Code.
The proposal is to alter an existing meat market into a commercial leasing space with emphasis
on businesses in the restaurant/entertainment services. According the Thurston County
Assessor’s Office the building was constructed in 1970 and is a single story 2520 square foot
building. The Change of Occupancy will be from an M Occupancy (retail) to an A-2 Occupancy
(restaurant). The occupancy number will be determined at plan submittal. For the purposes of
today’s notes the occupancy number will be assumed to be 168. The Change of Occupancy
shall comply with all of the applicable provisions of the IBC, Section 1002 2015 IEBC. Some but
not all of the requirements shall be:
• Two accessible building entrances shall be required. One accessible parking stall is
required for every 25 stalls. One van accessible stall is required for each six accessible
stalls, provided at least one van accessible stall is provided.
• An accessible path shall connect building entrances to public ways and accessible
parking stalls.
• An accessible route from the entrance to all primary functions within the building is
required.
• Accessible toilet rooms and fixtures shall be required for each sex. For an
entertainment services 3 water closets and 2 lavatories shall be required. For a
restaurant 2 water closets and one lavatory shall be required. Urinals may be
substituted for one of the water closets in the men’s toilet rooms.
• Fire alarm and fire sprinkler coverage is required in all entertainment service businesses
and restaurants with an occupancy exceeding 100. Fire hydrants and FDC may be
located between 25 and 150 feet from each other. West Road is a commercial collector,
Pre-Application Meeting
Page 7 of 8
fire hydrants and FDCs shall be located on a fire lane on the property. Fire lanes shall
be posted no parking and provide for fire truck turnaround.
• Mechanical Ventilation and exhaust shall meet the IMC Table 403.3 for fresh air and
exhaust.
• HVAC, Plumbing and building alterations shall comply with their respective code. A
grease trap or grease interceptor shall be required.
• Exposed wall and ceiling space shall be brought into compliance with the 2015 WEC.
• Kitchen exhaust hoods and cooking equipment shall meet code and manufacturers
requirements for clearances from combustible construction.
• Restaurants and entertainment services are subject to review by the Thurston County
Health Department. Approval from them shall be obtained prior to City of Yelm Building
Permit issuance.
•
Building elevations, site utility screening and refuse enclosure shall meet the design standards
in the Unified Development Code, and shall be submitted with the site plan review application.
A complete application includes the building permit application cover sheet along with:
• Five sets of plans, one of which may be half scale
• Two sets of engineering calculations, energy calculations, and specifications
• A photometric site lighting plan will be required as part of the civil plan submission.
OR a complete set of all plans in Adobe Acrobat portable document format may be submitted
via disk or thumb drive.
Prior to permit issuance two complete revised plan sets will be required for approval.
Integrated sprinkler and fire alarm system permits may be deferred.
Building permit review typically takes 8 to 12 weeks.
Fees & Charges
Site Plan Review $250.00
Civil Plan Review Billed on a cost recovery basis
Building Plan Review Based on 1997 UBC fee Schedule
Building Permit Based on 1997 UBC fee Schedule
Sewer Connection Fee $6,394.00 per ERU
Sewer Inspection Fee $145.00 per ERU
Water Connection Fee $6,159.99 per ERU
Water Meter Fee Based on meter size
Pre-Application Meeting
Page 8 of 8
Transportation Facilities Charge $1,497.00 per peak PM trip
The Transportation Facility Charge (TFC) is per new PM peak trip generated by the
development. Credit is given for the previous use.
Without a site plan and square footage I cannot give you a good estimate of TFC. If the entire
building was a sit down restaurant (not drive through), it would create approximately 12.5 new
pm peak hour trips. The TFC would be $18,862.20 Credit for previous retail $5,092.79 for a
total of $13, 769.41. Most retail or office uses create less trips than a restaurant, so the total
TFC would be less.