Loading...
01-8290 Project Rev & CorrespondenceCity of Yelm Invoice No. CDD-02-042 Community Development Department INVOICE - - Customer Name LASCO Bathware Address 801 N.P. Road City Yelm Phone 360-458-3900 State WA ZIP 98597 Date 2/6/02 Order No. SPR-01-8290-YL Rep Lasco Loading FOB Dock Hours Description Unit Price TOTAL City of Yelm Engineer Review Fees 16 Initial Plan Review $54.00 $864.00 2 Correspondence $54.00 $108.00 3 2nd Plan Review $54.00 $162.00 1 Correspondence $54.00 $54.00 SubTotal $1,188.00 Payment Details Shipping & Handling $0.00 O Cash Taxes WA O Check O TOTAL $1,188.00 Office Use Only City of Yelm. Community Development Department P.O. Box 479 Yelm, WA 98597 (360) 458-3835 fax (360) 458-3835 THANK YOU January 8, 2002 Robert Connolly Skillings-Connolly, Inc. 5016 Lacey Boulevard SE Lacey, Washington 98503 RE: Lasco Bathware Loading Dock -Civil Review No. 2 COY Project No. SPR-01-8290-YL Dear Mr. Connolly: I have reviewed the civil engineering plans dated 11/27/01 (Date of PE stamp) and have the following questions or comments. Please review these comments and address them when you submit your mylars for approval. 1. The 8" pipe connecting the trench drain to the oil-water separator needs to be ductile iron. The cover over the pipe in the loading dock in 1.92". 2. The above referenced pipe will also need to have a sleeve in the retaining wall where it passed through the wall. 3. The elevation on the oil-water separator outflow in higher than the inflow inlet. Typically they are even or the outflow is lower. Please verify this condition. 4. Section A-A Infiltration Trench needs to have 6" of washed rock above the pipe in the trench. Please revise this detail. 5. The approval block should have Development Review Engineer instead of Director of Public Works. Typical all sheets. If there are any questions or concerns about these comments, feel free to call me at (360) 458-8438 and we can discuss them before the mylars are submitted. You need to submit 2 sets of mylars, 2 drainage reports and 1 reduced set of plans. The reduced set should be 11X17 and to scale. Also submit the AutoCAD files and the drainage report on a CD for the City's archives. After signing the mylars one set will be returned to you and your client for your use. The client pulled a clearing and grading permit on Monday January 7, 2002. This permit will only allow them to excavate for the loading dock. However they still need to submit a building package to the building department. This will include all needed information for the Building Department to issue a building permit. Respectfully City of Yelm Community Development Jim Gibson Development Review Engineer Cc: Kevin Mullen Robert Springer Cathie Carlson ~, ~. City of Yelm Community Development P.O. Box 479 Yelm, WA 98597 (360) 458-3835 (360) 458-3144 FAX Memorandum To: SPRC From: Roberta Allen, Administrative Assistant Date: 12/3/01 Re: LASCO Bathware Civil Plans Attached please find Civil Plans for the LASCO Bathware Loading Docks for your review. Please return comments by December 13, 2001. If you have any questions, please give me a call. Thanks, Roberta C:\Community DevelopmentlProject Files\SPR Site Plan Review\8290 Lasco Loading Dock\Civil Plan Dist Memo.doc 09/04/01 13:03 FAX 253 735 4201 UV-ALiB KAI Cdj001/007 G,gs~o UTILITY UAULT'M P.O. Box 588 Auburn, WA 98071-0588 253-839-3500 800-892-1538 Fax 253-735-42U] Destination: City of 'Yelm Atte~ltion: Jlm Gibson Telephone Nunnber: Fax Number: From: tai Johnson Number of Pages Including Corner Sheet: 1 Comments: Good afternoon. Enclosed are several cut sheets. `~ Oldcastte Precast inc. 09/05/01 The 577 & 48-SA are both oil water separators. The 577 is suitable for up to 900 gallons & costs about $2200. The 4$-SA is suitable for 1000-1200 Gallons but costs about 53600. The last 4 pages are of the 577 & 44$4 -(~A. The gallon capacities are th.e same as the oil water separators. {The 576 is a vault made in our Qregon pla>t~t) ~o~~" 09/04/01 13:03 FAX 253 735 4201 L1V-ALIB KAI 0 002/OOi 577,~A TOP SECTION No.577-ST 3.2n01Ds HOLE FOR OUTLET %PE CONrRgCroq TO VERIFY sIZE a ~OCarION VAULT No.577-SB .~ 7,35010s OIL RETAINING BAFFLE FLOW DIFFUSER BAFFLE -~~ W Co 3030P, GALVANIZED DIAMOND PLATE COVER MOLE FOR INLET PIPE CONTRACTOR TO VERIFY SIZE a LOCATION Td' GRITiSLUD\ RETAINER WEIR -~ UV Co 1012. C3ALVANITED DIAMOND PLATE COVER$ ~ i ~ i ~ i UTILITY ~ALTL'T CO. Copyright 1992 120 WATER DEPTH GALLONS 4.0' 800 • ITEMS SHOWN ARE SUBJECT TO CHANGE WITHOUT NOTICE. FOR DETAILS SEE REVERS[: SIDE. Issue: April. 1982 09/04/01 13:03 FAX 253 735 4201 UV-ALiB KAI ~ 003/007 . _.._.. :.. . .. , ,:. ~,~ ~' ;~ , ~ U TOP SECTION No. 48-SA-T -- s,sso ~s UV Co. 1012P. Gewamzed Diamond Plate Cover 2 Places I!i~l- I-I!I!I~:I_I ~ I~I~~~~~i~l~l~l- I- I-I-I-I-I'I-~-i. j _j_I_I...~_, ~ t y.' Oil. LM Insert +1 Each Corner, 4 Corner3 I OUTLET PIPE With SempNng lee By Otfxrrs I 12' Dia, Hok -~ I + + ' ,~/ BASE ASSEMBLY No. 48-SA-B - t 5A801bs, On Retakning Baffle -- V 12' Dla. Hole 6'-s' !" ~ `~. UTILITY VAULT COMPANY __ For details of Access covers, See COVER Section. P,O BOx 588 Phone (253) 639.3500 'ITEMS SHOWN ARE SUBJL=CT TO CHANGE WtTMOUT NOTICE. auburn. Washington 980. 1.0588 Fe: (253) 735.4201 FOR DETAI~,S SEE REVERSE SIpE. µ Copyright O 1 gg5 O Oldmerlu (1oca-t, Inc, AU R~hfe Reservod 128 Issue: January, 1996 -- .......... ~.... -..... ............, -,,,. , ,.,.... ...~,..T,.-~.,.... . _._ _....... 48-SA 0!L WATER SEPARATOR 1,000 Gallon Capacity UV Co. 3030P, Galvanized Diamond Pldle Cover 2-Ton Lift Anchor d Places !n Top I-1- t•-7u _1-I.,I_I ~I~II + + I i I _ I + f Flow D+ffuaer ~ Baftte ~ INLET IPIPE Wiih Sampling lee By Others I gt0- I I 4 r L; ~I E 09/04/01 13:04 FAX 253 735 4201 LfV-ALiB KAI x}004/007 -~,_~..1 ... . ;'~L,~n1C~,T:ruw1" T-0' OVERALL .a 6'-6' INSIDE CLEAR 1. ~'`~+ S/<'0 FERRtfLE LOOP - ,~ (a) PLACES IN i0P 1 f/<'0 ROCKET tiFT INSERT • ~ (1) EA. ;ORNER. (q) CORNERS - 2t"o CLEAR ACCESS OPENI1gOS IN BASE ' -------- ------^--~"-ate-- '. ---- •-- ~ Y T cauLK eoTH slots •-~ R K 1 1 ~ ~ :r ~ i g'o HOLE ~ I 1 I ;/ ~~ f) `" q"o PIPE •~ TYPICAL i 1'-D'f x Z'-10' x 1 1/2' ~ ~ ~ KNOCKOUT (TYPICAL} ~, ~ 8"e HOLE PRECAST BAFFLE i TYPICAL -~ 3~ TWCK ' , ____ I ___ ...._...~....,___.....--V Y~ -- I ~__~ I I SLOT BOTH SIDES 3 ~/2" x S/t' 1'-g" S'-5' 1'-li" PLAN VIEW ODTIONAL ADJUSt TO GRADE Zt'e LOCKING FRAME B COVER VENT PIPES AIR ~ CAS T~GNT lYPlCAL }/t"0 LIFT WSERI (2) EA. SLOE, (2} SLOES + ~ ~ PRECAST BAFFLE -- 3' TtiiCK~--~ .-_ I ~ ~ RECOI~NENOATION: WLE1 i INLET ~,yj_ _.~ ~, i IS P PIPE pAwEIER i 1 "F - T' HIGHER 1HAN DUTLET ~ ~ /~-_- _~ , - 1- ~ Q----~ ~` I i -~--------------~__.--_--y--~- - - 1 Y-- -~' ~ ~ , , KNOCKOUT ~ - ~ ~ 1 i TYPICAL ~ I 1 u ~ ~ I ~ t/<'o LIFT INSERT ~ (1) EA. CORNER, (i) CORNERS ~ ; ~ ~ o b t TEE a EL80w-~ _r _ i ° d+ 1 ;. I~ ~ ~ ~ io ~-~~ _ ~ ; .~ R I 1 tl 3 i , i 1 ~ 1 I ~ I i ~ 1 1 ~ io I 'rv ` t ~ ~ -J v o I r CAULK 80Th SIDES I SLOT q t/Z. 3 t/2' : 3/t" TYP 4 -B~I.~-4~ SECTION AA OlfTi.Ff 09/04/01 13:04 FAX 253 735 4201 LIV-ALIB KAI l itR. ~ BENSON ~ 042 ~ br STRUCTURAl.NOTE3 1. CONCRETE - 28 OAY COMPRESSIVE STRENGTH f't = 45D0 psi 2. REBAR - A51M A-615 GRADE 60 S. MESIi - ASTM A^185 GRADE 65 a. DESIGN - ACl-118-99 BUILDING CODE ASTM C-840 'NIN1MuM STRUCNRAL DESIGN LOADING fOR MONOLITHIC OR SECTIONAL PRECAST CONCRETE WATER AND wASTEwAtER STRUCTURES' S. LOADS - H-20 TRUCK 1'n+EEI w/30'X IMPACT PER AASHTQ GENERAL NOTES 1, OUTIEY PIPE CAN BE ADJUSTED TO INCREASE OR DECREASE GALLON CAPACITY ?. FILL w/CLEAN WATER PRIOR TO START UP Of SYSTEM 3. CONTRACTOR TO SUPPLY k INSTALL AtL PIPING ~ SAMPUNC TEEti a, GRAY wa1ER ONLY. BUCK WATER SMALL BE GARBLED BY SEPARATE SIDE SEWER 5. FOR RE9VFORCEMENT DETAIL SEE QRAYANG GK-90D 6. FOR BAFFLE DETAIL SEE ORAw1NG CH-1073, SHEET 2 DESIGN CRITERUI UNIFORM PLUMBING CODE NUMBER Of MEALS WASTE FLOW x R£TENTLON X x STORA(,'E - CAPACTY PER PEAK hOUR RATE TIME facroR - IN GauONs SiiIPPING WEIGHT INSERTS COYER ~ J.245 Ibs COVER « (A) 3/4"o FERRUIC 100P BASE SECTION - 7.595 Tbs. BAS£ SECTION = (4) i t/4~o ROCKET INSERT BAFFLC = 8B4 Tbs. TOTAL riEiGH7 = 11,724 The. 8'o MOLE TYPICAL {CONTRACTOR TO CORE DRy,I OR KNOCKOUT IN fIELD) 1'-0'0 x 2'-IO' x 1 1/2 KNOCKOUT (TYPICAL, Y ORAi i DETAE~ i 0 NOTES WEIGHT INCLUDES BAFFLC pwl OCStfn>na+ ounn s'ZE Iwf~i~ 61LL Of MATERIAL IIEIr wuTatr 577 GA -GREASE INTER~PTOR SALES jNfORMATiON 525 - 850 GALLON CAPACITY STANDARD PRODUCT NStoHCB s.~ts `-~ ! ^~c 3/4`41'-0" RPPROVCO rn o , n o . a[u, oR.wN TOu a.r. 2 i/00 ~+et ~ ~ 2 N(~CMi 11.724 Ibs ( " ~ L ~ '7 Z l.rl- i "' ~ O / J t"A ylq,sQnl i1 t`f n`01't11.'l G tnf b1~" "'"' C0""" ''"°'°"""•"' ~(T:~(IL !\IIrC1h. W:T Jp 7NI.L NJf f, ~ UTIU7YVAULT COMPANY "Al~•n .NT •.., N.uroar, t~ .~ rx.n.: De v.o. aa,I sea .~ n, wA 9ao~ °~ P^xsK I1°. e'J'A~MiQ,'etn 7n.«.I. Orlply Mp, Y~ dTlt. N ,«„y Aulu~n,17L / YWvnrPr, as / Olb•y"ly„ Cf / CM'Idr, al / t ata\, CA f~ 005/007 09/04/01 13:04 FAX 253 735 4201 LiV-AUB KAI 9'-O" OVERnLL '<~ To ~_ ~ u lV YYY--- K ~ ~ O ~ - ~ -~ z 0 ~'o PIPE ~~ :e u N 9~-4' INSIDE CLEAR 3/4'e FERRULE LOOP (4) PLACES IN TOP 7/8"e CAL V. UF11NG IRON (4) PLACES IN @A$E 24"v CLEAR ACCESS OPENINGS _ ~ ~ - ' CAULK @OTH SIDES -' i o HOLE 8 TYPICAL i i ' I ~ ~ I I ' I ! ' ~ I I - I I I ~ ~ / I ' LJ - ~ ~~ t I ~~++~. -..1w1 ~~w~r- J_1 r~ ~ I I ~ ~-' I'1 ~ i I , ~ 1 I ~ ~ I ~ RECAST BAFFLE --~ 1 8'o r+OIE ;_.~ ' J' THICK , ~:~ + I I I I . r v WY Y> stor eoTrl sIDEs J T/2' Y J/4' I'-6' 3'-0- 3'-0` T'-6' PLAN VkEW ail' OPHONAL aOJUST TO GRADE 24'e LOCKING FRAME k COVER VENT PIPES AIR dt GAS T1GMT TYPICAL 3 PLACES I I I , I ~- ~ ~1 + i INLET V ~ W N 1 iC PRECasT sAFFLe ~_ ' } J TfiIC1( I 1 3/4~e lIF'r INSERT I I , i (2) EA. SLOE. {7) SIDES ~ r _ - ~ -` I I - ~ I ! I ~~ I ~t Y/ i ~ I ~ J- ~ - _~ _ I L--~----------__ i RECOMMENDATION: INLET ~ I ' ' I > ~ IS A PIPE DIAMETER I __ I HIGHER THAN OUTLET ~ I TEE ar E~@OW ~ i - i ~ ~ ~ I j 1 1/4'0 LIFT INSERT ~ ~ I i i (I) EA, CORNER, ({) CORNERS i ~ ~ , ~ ~.. ~ o N l_1 0 ~ I ~ n /"t. CAULK BOTH SIDES -' I ~ SLOT I~ 3 I/Z' Y J/4' 6'-0- 1 3'-0' SEC~iON AA erWi. C. ~WOIw4na' ~wa"~r ~t/l'/N I I/4"o ROCKET LIFT INSERT (i) EA CORNER (4) CORNERS IN CENTER SECTION ~{'~ YwD`e Y 2'-1D~ Y ~ I/2' KNOCKQLIT (TY9ICAL) KNOCKOUT TYPICAL ~ oos/oo7 _ ~ OUTLET K K O ' N E J~ f ~ U' ~ $ .I I •; ~ ~ b 7/8'o CALV. LIFTING IRON (2) EA. ENO. (2) ENDS 09/04/01 13:05 FAX 253 ?35 420I1 UV-AC16 KAI tf~1_ NLYISIUV I UAIL I YI STRUCTURAL NOTES 1. CONCRETE - 28 OAT COMPRESSIVE STT1EnGTH f'e .4500 psl 2. REBAR - ASTM A-815 GRADE 60 3. MESH - ASTM A-t85 GRADE 65 4. OESIGIJ - Ap-318-99 BUILDWG CODE ASTM C-890 'MINIMUM SiRUCTURAI DESIGN LOADING FOR MONaITHIC oR SECnONAL PRECAST CONCRETE WA1ER ANO WASIEIYATER STRUCTURES' S. LOADS - H-20 TRUCK tNHEEt W/30X IMPACT PER AASHTO GENERAL NOTES I. OUTLET PIPE CAN BE AOJUSTfO TO INCREASE OR DECREASE GALLON CAPACITY 2. fill w/CLEAN WA'rfR PRIOR TO START UP D< SYSTE1a J. ..CONTRACTOR TO SUPPLY & INSTALL AI.L PIPING dt SAMPLING TEES 4. CRAT WATER ONLY. BLACK WATER SHALL BE CARRIED BY SEPARATE SIDE SEWER S. FDR REINFORCEMENT OETAk SEE ORANING CK-901 B. FOR BAFFLE DETAIL SEE DRANINC Ch-1074, SHEET 2 DESIGN CRITERu UNIFORM PLUMBING CODE NU>wBER OF MEALS WASTE FtOw x RETENTION x CAPACITY STORAGE PER PEAK HOUR RATE TzIaE X _ fACTat IN GALLONS SHIPPING WFJGHT INSERTS COVER = 4,933 ID:• COVER .• (4} 3/<'a FERRULE LOOP CENTER SECnON = 6,33a Ibs. CENTER SECTON = (4} 1 1/~'~ ROCKET INSERT BASE SECnON = J,456 Iba, BASE SECTION • (4) 7/8'4 GALV. LIFTWG IRON BaffLE = 969 Ibs. TOTAE WEIGHT ~ 15.691 Ibs. 4`r PIPE JOINT 8's HOLE TYPICAL r (CONTRACTOR TO CORE OR4L OR KNOCKOUT __ IN FIELD) r I'-0`e % 2'-10' r 1 t/2' r KNOCKOUT (TYPICAL} o i I ~ ~ , l-J DRAFT DETAIL 1 NOTE: WEIGHT INCtU0E5 BAFFLE P'^~ o[scNivnat aww s'z. 81LL OF MATERIAL Iru ourwnt. 44$4 GA •• CREASE INTERC~pTOR SALES INfORMATIpN 675 - 1,150 GALLON CAPACITY STANDARD PRODUCT tus,or~F s,us s,o, y scnu 3/4•c1•_0• rrvAaco owo rop N[v ~.~ >aY o~lt 1/1/DD ~~i I bT ~ ,~~~[ ,5.692 Iba CH -10 7 4 not DOtU4rn ,y n,[ nOOrN~f .11 Nt Ymo, wal ;,OoFAm. ~[ ~, >«„"~ .tn MUlMNC IM1RROStf EMI Wf. 7'A:.l M0~ 6i ° UTIUTYVAULT COMPANY ~oriso.mq P~gC11C u:oD rv Anr+a•+~.r,aio.; ;0 n,[ ~~r[a(Ct1 0[ fMD COW W!. P.0 00~ 9BE AuOurn, Wl 900~~-DSPO LMM1ipltojrHt rnlcv.w O.,,Hti nt., An nu'I~ A.waa 1"OUTiWI / 1Atenkly, ON / OMatmtnr4 C4 / CAUnu lu, A7 / ~wla'a, Cl ~joo7/o07 q Of THE ~p~~~ 4 en _ 10.5 Yelm Avenue West ,YELL P.O. Box 479 WASHINGTON Yelm, Washington 98.597 (360) 4.58-3244 SEPA N0: 8290 DETERMINATION OF NONSIGMFICANCE Proponent: LASCO Bathware Description of Proposal: Construction of a new 6-bay loading dock Location of the Proposal: 801 NP Rd., Yelm, WA 98597 Section/Tcwnship/Range: NE'/4, Section 19, Township 17N, Range 2E, W.M. Threshold Determination: The City of Yelm as lead agency for this action has determined that this proposal does not have a probable significant adverse impact on the environment. Therefore, an environmental impact statement (EIS) will not be required under RCW 43.21 C.030(2)(c). This decision was made after review of a completed environmental checklist and other information on file with the lead agency. This information is available to the public on request. Conditions/Mitigating Measures: NONE Lead agency: City of Yelm Responsible Official: Shelly Badger, City Administrator Date of Issue: August 6, 2001 Comment Deadline: 5:00 p.m., August 20, 2001 Shelly Badger, City Adminis rator J if This Determination of NonSignificance (DNS) is issued pursuant to Washington Administrative Code 197-11-340(2). Comments must be submitted to Catherine Carlson, Community Development Director, at City of Yelm, 105 Yelm Ave. W., P.O. Box 479, Yelm, WA 98597, by 5:00 p.m., August 20, 2001. You may appeal this determination to the Yelm City Council, at above address, by submitting a writter: appeal no later than 5:00 p.m., August 26, 2001. You should be prepared to make specific factual objections. Contact Cathie Carlson, Community Development Director, to learn more about the procedures for SEPA appeals. This DNS is not a permit and does not by itself constitute project approval. The applicant must comply with all applicable requirements of the City of Yelm prior to receiving construction permits which may include but are not limited to the City of Yelm Comprehensive Plan, Zoning Title (17), Critical Areas Ordinance (14.08), Storm water Drainage Design and Erosion Control Manual (DOE), Uniform Building Code, State Environmental Policy Act (SEPA) Title (14), Road Design Standards, Platting and Subdivision Title (16), and the Shoreline Master Program. DO NOT PUBLISH BELOW THIS LINE Pubiished: Nisqually Valley dews, Friday, August 10, 2001 Posted in public areas: August 6. 2001 Copies to: All agencies/citizens on SEPA mailing list and adjacent property owners, August 6, 2001 Dept. of Ecology w/checklist. August 6, 2001. MEMOflANDUM To: SPRC From: Cathie Carlson Date: July 16, 2001 Subject: SPR-01-8290-YL -Project review schedule for Lasco Loading Docks Attached is the application packet for the above referenced project. After your initial review of the information submitted, if you need additional information from the applicant, please let me know as soon as possible. The following is the tentative review schedule for the project. July 16 -Notice of Application distributed -begin 15 day comment period. Aug 1 -SPRC environmental review. Department comments/mitigation requirements for Environmental Review. Aug 6 -Environmental Determination issued by Planning Department. Begin 14 day comment period followed by 7 day appeal periord. Aug 22 and Aug 29 -SPRC project review. Department comments/conditions of approval for staff report. Aug 27 -Environmental Determination appeal time expired. Sept 5 -Letter of Approval completed.